1 OPTICAL QUALITY OF DUAL- OPTIC ACCOMMODATING INTRAOCULAR LENS Andrea Galvis, MD 1,3 a Ivan Ossma, MD MPH MSc 1,2, a Sanjeev Kasthurirangan, PhD 4, b.

Slides:



Advertisements
Similar presentations
1 Comparison of Distance Image Quality with Accommodating and Multifocal Aspheric Presbyopia-Correcting IOLs John F. Doane, M.D., F.A.C.S. Discover Vision.
Advertisements

VisTor The new Toric IOL by Hanita Lenses
Theoretical Optical Performance of an Equal Conic Intraocular Lens and Comparison to Spherical and Aspheric IOLs Edwin J. Sarver, PhD.
Dr H. Razmjoo Isfahan University of Medical Sciences Multifocal IOLs
Diffractive Multifocal IOL Prof. Dr. Daniel H. Scorsetti
Eye- Structure and Refraction
V. S. Liarakos, K. van Dijk, L. Ham, L. Baydoun and G.R.J. Melles Anterior Chamber vs Posterior Chamber IOL in DMEK for Pseudophakic Bullous Keratopathy.
Visual outcome & subjective visual symptoms of the Tecnis ZM900 multifocal intraocular lens in Asian eyes Dr Colin S.H. Tan MBBS, MMed (Ophth), FRCSEd.
Multifocal Intraocular Lenses & Contrast Sensitivity
Aspheric IOL’s: clinical benefits and customizing cataract surgery Bojan Pajic, MD, PhD, FEBO Swiss Eye Research Foundation, ORASIS, Reinach, Switzerland.
Ocular Aberrations and Quality of Vision with Aspheric Single-Piece and Spherical Multi- Piece IOL: Contra lateral Comparative Study Ahmed Assaf MD, FRCSEd.
Myoung Joon Kim, MD Len Zheleznyak, MS2
CLINICAL OUTCOMES WITH A NEW DIFFRACTIVE MULTIFOCAL INTRAOCULAR LENS (IOL) Pilar Casas de Llera Ana Belen Plaza Alfredo Vega-Estrada Jorge L Alio Vissum.
Cataract Surgery Using Biaspheric IOLs in Patients With Corneal Irregularities James P. Gills, MD St. Luke’s Cataract & Laser Institute Tarpon Springs.
Ruth Lapid-Gortzak MD PhD 1,2, Jan Willem van der Linden BOpt 2, and Ivanka J. van der Meulen MD 1,2 1 Department of Ophthalmology, Academic Medical Center,
Progressive Multifocal Intraocular Lens G. Rubiolini M.D. Italy Disclosure of finanacial interest Author's research is partially funded.
Mayank A. Nanavaty, DO, MRCOphth, MRCS(Ed) David J. Spalton, FRCP, FRCS, FRCOphth James F. Boyce, PhD Thomas J. T. P. Van den berg, PhD St. Thomas’ Hospital,
BLOC 5: MULTIFOCAL LENSES Subject 16.- Multifocal lenses. Classification. Subject 17.- Bifocal lenses. Subject 18.- Progressive addition lenses.
Repeatability of Anterior and Posterior Corneal Higher- Order Aberrations in 4 mm, 6 mm and 8 mm diameters measured by Pentacam System Jadwiga Wojtowicz.
W. A. Maxwell, MD, PhD ASCRS 2008 Comparison of the Optical Image Quality for Presbyopia Correcting IOLs using Modulation Transfer Function Testing W.
Wavefront by Method of Ray Tracing: Because the Eye is Not a Telescope
Recent Advances in Intraocular Lenses Jim Schwiegerling, PhD Ophthalmology & Vision Sciences Optical Sciences.
Evaluation of Corneal Parameters and Spherical Aberration After DSAEK Measured with Pentacam System Orkun Muftuoglu, Pawan Prasher, R. Wayne Bowman, Steven.
W. Maxwell, MD, PhD California Eye Institute Fresno, California
For Accommodative Lenses Deepak Chitkara, M.B., ChB. D.O.
Unilateral multifocal lens implantation in patients with a contralateral monofocal or phakic eye is a viable presbyopic correction option Robert J. Cionni,
A Fellow Eye Comparison of Aberrations, Modulation Transfer Function and Contrast Sensitivity After AcrySof IQ and AcrySof Natural IOL Implantation. Mayank.
A New Definition of Refraction: Basics and Beyond Austin Roorda, Ph.D. Unversity of Houston College of Optometry.
Clinical and simulation outcomes of a multifocal intraocular lens with rotational asymmetry and two different levels of near addition Jorge Alió, MD,PhD.
P91: Clinical Performance of Phakic Angle-Supported Investigational IOL in Prospective Global Trials, ASCRS 2010, Boston P91: Clinical performance of phakic.
Predicting visual performance from wavefront quality metrics in cataract Konrad Pesudovs Katja Ullrich NH&MRC Centre for Clinical Eye Research, Flinders.
Reproducibility of Optical Measurements in Pseudophakic eyes Using Double-Pass Measurement System St Thomas Hospital, London Anish Dhital, David Spalton,
OHM Effect of low-to-moderate degrees of refractive astigmatism on Contrast sensitivity and Reading speed in pseudophakic eyes Shetal M. Raj, DO, MS, Abhay.
Adriana S. Forseto1, MD Walton Nosé1,2, MD
AcrySof ® ReSTOR ® Aspheric IOL. Aspheric IOL AcrySof ® ReSTOR ® 2 AcrySof ® ReSTOR ® Aspheric IOL SN6AD3 Add Power: +4 D Spectacle Plane: 3.2 D Range:
Ophthalmology & Vision Sciences
Influence of IOL optic material on posterior capsule opacification and visual function Ken Hayashi, MD Hideyuki Hayashi, MD Hayashi Eye Hospital, Fukuoka,
Sherman W. Reeves, MD, MPH 1,3,4 ; Jacob A. Kozisek, OD 1,2 ; Noumia Cloutier-Gill, OD 1,2 ; David R. Hardten, MD 1,2,3,4 Accuracy of Scheimpflug Imaging.
Ocular functional optical zone following hyperopic LASIK/PRK: Analysis based on polychromatic retinal image quality Mitchell P. Weikert, MD Li Wang, MD,
S. Lee/M.Kim 2010 M. Kim 1, H. Lee 1, S. Lee 1,, S.D. Lee 1 1 ASA-Vision Clinics Seoul Comparative Analysis Preliminary Results of.
LogMAR-Analysis of multifocal intraocular lenses: Clinical performance A. Mannsfeld, I.-J. Limberger, A. Ehmer, M.P. Holzer, G. U.Auffarth International.
Financial Disclosure: Medical Director–Galilei R&D Consultant, Ziemer Group AG, Port, Switzerland Consultant & Territory Manager for.
Variations in refractive analysis with different diffractive multifocal intraocular lenses using different wavefront analyzers Mami Yoshino, Hiroko Bissen-Miyajima,
iTrace Dynamic Laser Refraction: Clinical Application
Jay Fiore MD, Eric Donnenfeld MD, Hank Perry MD, Dana Morschauser OD
Comparison of visual function following piggyback implantation of Acrysof ReSTOR intraocular lenses with Tecnis multifocal ZM900 intraocular lenses. Rodrigo.
Investigation of Multifocal Toric IOLs to Compensate for Corneal Astigmatism and to Provide Near, Intermediate, and Distance Vision José L. Rincón, MD.
Preliminary Results after Cataract Surgery with the Aspheric Acrysof ReSTOR IOL to Correct Presbyopia Meeting of the ASCRS Chicago 8-10 February 2007 R.M.M.A.
Warren Hill, MD, FACS East Valley Ophthalmology 5620 E. Broadway Road
Inadvertent Insertion of an Opposite- Side Tecnis ZM900 Multifocal IOL Wilson Takashi Hida, M.D. Celso Takashi Nakano; Jonathan Lake;
9-Month Results after Implantation of a new accommodative IOL that works with one focus Mark Tomalla M.D.* Clinic for Refractive and Ophthalmic Surgery,
Global Meta-Analysis on Visual and Optical Quality Comparison for Aspheric vs Spherical IOL Technology James P. McCulley, MD Department of Ophthalmology.
Pearls for Success with the Synchrony Dual-Optic Accommodating IOL Preloaded Injector Víctor M. Bohórquez, MD Ricardo Alarcón, MD ServiOftalmos Bogotá,
Date of download: 5/30/2016 Copyright © 2016 American Medical Association. All rights reserved. From: Quantitative Performance of Bifocal and Multifocal.
Multifocal lenses analysis with OQAS system Dr Alfredo Castillo Hospital Quirón Madrid ASCRS Chicago.
CATz for Highly Irregular Corneas after Keratorefractive Surgery Hamed M. Anwar, MD, FRCS Alaa El-Danasoury, MD, FRCS 1 Institutional affiliation: Magrabi.
Outcomes Update for an Aspheric Accommodating IOL John A. Hovanesian, M.D. Clinical Instructor, UCLA Jules Stein Eye Institute Harvard Eye Associates,
Vinohrady Teaching Hospital, Prague, Czech Republic Vinohrady Teaching Hospital, Prague, Czech Republic M. Vokrojova MD, M. Vokrojova MD, D. Sivekova MD,
Kavita Gala David Spalton Mayank Nanavaty St Thomas’ Hospital , London
Postoperative Refraction and Patient Satisfaction after Bilateral Implantation of Presbyopia-Correcting Intraocular Lenses Robert Cionni, MD Financial.
Hayashi Eye Hospital, Fukuoka, Japan
Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation Zina Zhang MD1, Logan.
Thomas Kohnen, MD Department of Ophthalmology
Mohamed A Guenena, MD Helga P Sandoval, MD, MSCR Kerry D Solomon, MD
Comparison of vision with an accommodating IOL versus a multifocal IOL
Pharmacological Correction of Presbyopia: A preliminary Study
Preoperative Distribution of Higher Order Aberrations in Patients Undergoing LASIK Perry S. Binder, MS MD.
*Center for Excellence in Eyecare
Visual Outcomes and Satisfaction with Toric IOL Versus Monofocal IOL
Long-Term Quantitative Analysis of Posterior Capsule Opacification After Implantation of Dual-Optic Accommodating IOLs Andrea Galvis, MD 1 , 3 Ivan.
Presentation transcript:

1 OPTICAL QUALITY OF DUAL- OPTIC ACCOMMODATING INTRAOCULAR LENS Andrea Galvis, MD 1,3 a Ivan Ossma, MD MPH MSc 1,2, a Sanjeev Kasthurirangan, PhD 4, b 1 Fundacion Valle del Lili, Cali-Colombia 2 Universidad Industrial de Santander, Bucaramanga-Colombia 3 Universidad Autonoma de Bucaramanga, Bucaramanga- Colombia 4 Abbott Medical Optics Inc, Irvine, USA Financial Disclosure a Consultant Abbott Medical Optics b Scientist at Abbott Medical Optics Inc. The Synchrony IOL is not currently FDA-approved

2 Synchrony Design  Anterior Optic 32 Diopters  Posterior Optic Divergent (negative) 2

3  Compare Optical Quality Pseudophakic Eyes  Monofocal IOL  Synchrony Dual Optic Accommodating IOL  Parameters  Objective iTrace aberrometry  Custom Matlab Software to calculate MTF  Subjective Contrast Sensitivity Testing  Optec 6500 Study Purpose

4 Study Population iTrace aberrometry Cycloplegia 3 mm zone Matlab Software to calculate MTF Monofocal IOL : 15 subjects (30 eyes) Synchrony IOL : 16 subjects (32 eyes)

5 iTrace - Matlab conversion

6 Results

7 Objective Measurements 3 mm pupil Difference 0.01 um

8 Best-focus MTF 3 mm pupil Differences are less than 10%

9 Mesopic Contrast Sensitivity p=0.61 Wilcoxon Rank Sum Test 9

10 Dual Optic Design DOES NOT affect optical or retinal image quality of the eye Objective evidence (iTrace, MTF) Subjective evidence (CSF) Contrast sensitivity of Synchrony is equivalent to that of monofocal IOLs Discussion

11 Discussion Effect of the slight spherical aberration on Synchrony would only yield 0.42 D of increased depth of focus Calculations based on Rocha’s work * The improved near vision of Synchrony patients MOST LIKELY due to true accommodation * Rocha KM. Using Adaptive Optics Simultion to Explore the Effect of Higher Order Aberrations on Depth of Focus for the Correction of Presbyopia. Wavefront Congress 2008

12 Conclusion Quality of Vision of Synchrony IOL similar to standard monofocal IOLs Measured Subjectively Measured Objectively Improved Near Vision with Synchrony Not related to increased depth of focus