Presentation is loading. Please wait.

Presentation is loading. Please wait.

Myoung Joon Kim, MD Len Zheleznyak, MS2

Similar presentations


Presentation on theme: "Myoung Joon Kim, MD Len Zheleznyak, MS2"— Presentation transcript:

1 Optical Evaluation of Premium Intraocular Lenses Using Optical Bench Testing System
Myoung Joon Kim, MD Len Zheleznyak, MS2 Scott M. MacRae, MD2 Geunyoung Yoon, PhD2 University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea Flaum Eye Institute, University of Rochester, Rochester, NY, USA M. J. K. and L. Z. have no financial or proprietary interest in any material or method mentioned. S. M. M. and G. Y. are consultants of Bausch and Lomb. S. M. M. is a consultant of Acufocus and Technolas.

2 optical quality and through focus performance
Premium Intraocular Lenses expanded range of vision spectacle freedom for What about optical quality and through focus performance? This study was performed to evaluate optical quality and through focus performance of premium intraocular lenses.

3 Optical Bench Testing of IOLs in Wet Cell IOL Mount
Direct Retinal Image Quality Measurement Cropped for Analysis  ~20/40 ~20/20  1951 US Air Force Resolution Target L1 AP L2 L3 TL L5 AFRT IS WC & IOL AT PC AFRT; Air Force resolution target, L1; Lens 1, L2; Lens 2, L#; Lens #, AP; artificial pupil, PC; pupil camera, AT; alignment target, TL; trial lens, WC; wet cell, IOL; intraocular lens, IS; image sensor

4 Optical Bench Testing of Intraocular Lenses USAF Target Imaging Camera
Pupil Camera White Light Source Illumination USAF Target Imaging Camera IOL Mount (Wet Cell) 4

5 Premium IOLs Tecnis AcrySof ReSTOR Crystalens ReZoom Abbott Alcon
SN6AD3 (+4.0 add) SN6AD1 (+3.0 add) ZM900 apodized diffractive aspheric multifocal IOL diffractive aspheric multifocal IOL Crystalens Bausch & Lomb ReZoom Abbott NXG1 HD500 accommodative multifocal IOL refractive multifocal IOL

6 Controls 20D IOLs AcrySof Natural SofPort AO B&L Alcon LI60AOV SN60AT
aberration-free monofocal IOL (reference lens) SN60AT spherical monofocal IOL 20D IOLs

7 LI60AOV = SofPort AO, SN60AT = AcrySof spherical, SN6AD3 = ReSTOR +4D,
Defocus LI60AOV = SofPort AO, SN60AT = AcrySof spherical, SN6AD3 = ReSTOR +4D, SN6AD1 = ReSTOR +3D, NXG1 = ReZoom, ZM900 = Tecnis multifocal, HD500 = Crystalens HD

8 LI60AOV = SofPort AO, SN60AT = AcrySof spherical, SN6AD3 = ReSTOR +4D,
Defocus LI60AOV = SofPort AO, SN60AT = AcrySof spherical, SN6AD3 = ReSTOR +4D, SN6AD1 = ReSTOR +3D, NXG1 = ReZoom, ZM900 = Tecnis multifocal, HD500 = Crystalens HD

9 LI60AOV = SofPort AO, SN60AT = AcrySof spherical, SN6AD3 = ReSTOR +4D,
Defocus LI60AOV = SofPort AO, SN60AT = AcrySof spherical, SN6AD3 = ReSTOR +4D, SN6AD1 = ReSTOR +3D, NXG1 = ReZoom, ZM900 = Tecnis multifocal, HD500 = Crystalens HD

10 REZ = ReZoom, TEC = Tecnis multifocal, CLH = Crystalens HD
Cross-correlation coefficients (CCC) between the perfect and actual images were computed as an image quality metric to quantify image quality and are ranged from 0 (worst) to 1 (best). SAO = SofPort AO, ASS = AcrySof spherical, RS4 = ReSTOR +4D, RS3 = ReSTOR +3D, REZ = ReZoom, TEC = Tecnis multifocal, CLH = Crystalens HD

11 Summary Image Quality for Distant Objects
4 mm Pupil SAO > ASS ≈ CLH > RS4 ≈ RS3 > TEC > REZ Image Quality for Intermediate Objects 4 mm Pupil, ~ 1 D CLH > TEC ≈ ASS > SAO ≈ REZ > RS4 ≈ RS3 Image Quality for Near Objects of Multifocal IOLs 3 mm Pupil RS3 > TEC ≈ REZ > RS4 Working Distance for Near Objects of Multifocal IOLs RS4 ≈ TEC < REZ < RS3 SAO = SofPort AO, ASS = AcrySof spherical, RS4 = ReSTOR +4D, RS3 = ReSTOR +3D, REZ = ReZoom, TEC = Tecnis multifocal, CLH = Crystalens HD

12 Conclusion Different premium IOLs have their own optical characteristics. Therefore, selection of premium IOLs should be based on the understanding of optical properties. Thank you!


Download ppt "Myoung Joon Kim, MD Len Zheleznyak, MS2"

Similar presentations


Ads by Google