CONTENT S ⅠⅠ Characteristics of CANDU Reactor & Tritium ⅡⅡ Tritium Measurements ⅢⅢ Needs of the equipment development ⅣⅣ Automatic Multiple Tritium Sampler(AMTS)

Slides:



Advertisements
Similar presentations
An innovative tool for the review of health and safety work practices and the implementation of effective controls of particulate exposures.
Advertisements

IGCSE ICT Control Systems.
Corrosion Products Sampler (CPS)
TG-EL-D5 Preferred Instruments Multi-Tank Gauge D5 Overview.
3.7.4 Student Book © 2004 Propane Education & Research CouncilPage Identifying Testing Procedures for Anhydrous Ammonia (NH3) Contamination Because.
Special Applications Timed shut-off function Intelsteer Power Saver.
4 key operations UP/ DOWN 、 Esc and Enter Only 3 keys are needed for the rator to adjust all the parameters Simple Esc key Chips Programmable Intelsteer.
Issues Associated with the Development of Severe Accident Management Guidelines for CANDU Reactors Keith Dinnie Director, Risk Management Nuclear Safety.
ENGINE ROOM LOG.  During the watch a log is kept of the various parameters of the main and auxiliary equipment. This may be a manual operation provided.
Hydraulics.
MODULE “PROJECT MANAGEMENT AND CONTROL” EMERGENCY PLANNING SAFE DECOMMISSIONING OF NUCLEAR POWER PLANTS Project BG/04/B/F/PP , Programme “Leonardo.
Gauges and well logging
COMPUCCINO Kalani Rathnabharathi Vithya Shanmugam Robert Armstrong Aaron Kulp.
Dental X-ray Film Processing
Des Murphy Kovara Energy Consultants Establish a Measuring and Monitoring System Energy MAP Step 18 K O V A R A Energy Consultants.
Lesson 5 What devices do we use to measure radon?.
What is the It is the Next Generation, Calibration Station for the GasBadge ® Plus Personal Monitor
Lease Automatic Custody Transfer
Computer Process Control Application. Computer process control In computer process control, a digital computer is used to direct the operations of a manufacturing.
PUMP TESTING BY KAUSTUBH V GITAPATHI DIRECTOR VI AUTOMATION (P) LTD, PUNE.
Heart Rate What Does the Pumping Mean?. State Science Content Standard Students will recognize and provide examples that human beings, like other organisms.
ERT 312 SAFETY & LOSS PREVENTION IN BIOPROCESS HAZARDS IDENTIFICATION Prepared by: Miss Hairul Nazirah Abdul Halim.
Tritium Release Reduction based on Release Trend Analysis JASON SHIN Korea Hydro & Nuclear Power co.
Chemical Dispersion Experiments in DAPPLE Centre for Atmospheric Science School of Chemistry University of Bristol Bristol BS8 1TS.
Wolsong NPP II KHNP JASON SHIN Korea Hydro & Nuclear Power co.
NetVuze Precision Network Meter standalone, easy to use, networked with data logging.
Heliocentris Commercial Confidential 1 Integration of Industrial Fuel Cells in Technical Applications Using the NEXA ® Training System Dr. Claus Fischer.
Topic 5 – Sensors and Monitoring Systems 1)TechMed scenario covers Sensors and their uses in hospitals In the scenario: “A patient-monitoring system is.
Nuclear Energy. The Fuel: Uranium Present nuclear power plants consume U- 235 as fuel Uranium has 92 protons Two isotopes are important. U-235 has an.
Operating and maintenance of generator. Operating Generator If it is manually operated generator, whenever power goes off, before starting the generator,
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
900-LC P. van Poppel – Field Support Specialist October 2009.
1 HBD Update Setback via Gas Accident T.K. Hemmick for the HBD Crew.
WELCOME TO SEMINAR ON SCADA WELCOME TO SEMINAR ON SCADA Presented by: ANIL KUMAR RAUT Adm No:33IE/2k.
,Yalta,17-th Symposium of AER1 IMPACT OF CHANGED FUEL PERFORMANCES ON SAFETY BARRIER EFFECTIVENESS AT NORMAL OPERATION OF NPP WITH VVER A.V.
MODULE “PROJECT MANAGEMENT AND CONTROL” SAFETY ASSESSMENT DURING DECOMMISSIONING SAFE DECOMMISSIONING OF NUCLEAR POWER PLANTS Project BG/04/B/F/PP ,
Training Course SuperCool 1000 Level 1 Course #P0131.
Fukushima Daiichi Nuclear Plant Event Summary and FPL/DAEC Actions.
Active gas system status. S.Konovalov, K.Zhukov. Active gas system operation. S.Konovalov "Active gas system..."TRT Overview  Good design.
Timer Timer is a device, which counts the input at regular interval (δT) using clock pulses at its input. The counts increment on each pulse and store.
Human Powered Modular System Purpose: Create a device capable of providing basic needs to people in developing nations at a relatively low cost Focus:
Chapter 2 Basic Principle of PLC PLC Configuration &Function   Basic Configuration  CPU  Memory  Programming Interface  Communication.
Section 1Nuclear Changes Section 1: What is Radioactivity?
Building a CANDU reactor
March 11, 2011 to Present. Presentation Overview Reactor Design and FeaturesChronology of EventsCurrent Status of Each ReactorRecovery Actions Kashiwazaki-Kariwa.
Logic Analyzer ECE-4220 Real-Time Embedded Systems Final Project Dallas Fletchall.
By, Kaya Zepeda, Joselyne Soto, Greg Maginn, Sebastian Hickey, and Chase Lewis.
What tests are necessary to make sure your kegs are being cleaned, sanitized and filled correctly By Andrew J. Brewer
Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Converting ASME Tanks in Ammonia Service to Propane.
Service Section Technical Training December 2005.
EMBEDDED SYSTEM & ROBOTICS. Introduction to robotics Robots are machines capable of carrying out a complex series of actions automatically. Robotics is.
Organization and Implementation of a National Regulatory Program for the Control of Radiation Sources Technical Services.
بسم الله الرحمن الرحيم MEMORY AND I/O.
Time Management.  Time management is concerned with OS facilities and services which measure real time.  These services include:  Keeping track of.
ERT 312 SAFETY & LOSS PREVENTION IN BIOPROCESS HAZARDS IDENTIFICATION
 Heat travels from hot to cold  The bigger the temperature difference the faster the rate of transfer.
F-900 PORTABLE ETHYLENE ANALYZER INSTRUMENT TRAINING
Camera Basics. Film (Analog) Cameras Digital Cameras Types of Cameras.
PRESENTATION CSE 341 MICROPROCESSOR Presented By Nabid Kaisar
30GHz system improvements Jan Kovermann RF meeting
Irrigation System Controllers.  A controller is an integral part of an irrigation system.  It is an essential tool to apply water in the necessary quantity.
2.1 & 2.2: Rainfall Detection and Alarm System
Chernobyl disaster The worst manmade disaster in human history
Hemodialysis Lecture 3.
UNIT – Microcontroller.
Catalina Chitu, Vasile Simionov, “CNE-PROD Cernavoda” NPP, Romania
How SCADA Systems Work?.
Nuclear Chemistry Physical Science.
Group 1 Best Group.
Presentation transcript:

CONTENT S ⅠⅠ Characteristics of CANDU Reactor & Tritium ⅡⅡ Tritium Measurements ⅢⅢ Needs of the equipment development ⅣⅣ Automatic Multiple Tritium Sampler(AMTS) ⅤⅤ Conclusions & Expectations ⅥⅥ Future Plans

Characteristics of CANDU Reactor and Tritium Ⅰ ▣ Natural Uranium Fuel contains 0.7% of U-235 ▣ Use of the Heavy water (D 2 O) as Coolant and Moderator ▣ The interactions of neutrons with Heavy water → Tritium Occurrence ▣ CANDU Reactor in Korea → Wolsong Plant 1 & 2 Characteristics of CANDU Reactor

▣ Hydrogen with 2 neutrons exists gas or vapor status. ▣ Pure Beta-emitting radionuclide, Half-Life : 12.3 years. ▣ Maximum Energy : 18.6keV, Average Energy : 5.6keV ▣ Internal exposure is the more harmful to the body via inhalation or wounds. Characteristics of Tritium Characteristics of CANDU Reactor and Tritium Ⅰ

▣ Use of the Fixed Tritium Air Monitors (FTAM) Methods of Tritium Measurement Tritium Measurements Ⅱ

▣ Use of the Portable Tritium Meter Methods of Tritium Measurement Tritium Measurements Ⅱ

▣ Use of the Liquid Scintillation Counter Methods of Tritium Measurement Tritium Measurements Ⅱ

▣ Use of the Fixed Tritium Air Monitors (FTAM) Methods of Tritium Measurement Tritium Measurements Ⅱ

▣ Use of the Portable Tritium Meter Methods of Tritium Measurement Tritium Measurements Ⅱ

▣ Use of the Liquid Scintillation Counter Methods of Tritium Measurement Tritium Measurements Ⅱ

Methods of Tritium Measurement ▣ Use of the Liquid Scintillation Counter Tritium Measurements Ⅱ

▣ Observations of radiation for several areas in Radiation zone with the routine [*1) tritium sampling and analysis [*1) 3 shift operators on duty [*2) TRF(Tritium Removal Facility) Status of Tritium measurements Tritium Measurements Ⅱ

▣ At the abnormal situation(Tritium concentration rising), add the sampling points around the suspicious leakage area. ▣ At the leakage situation of Tritium, add the additional sampling and measurements of Tritium concentration. ▣ One sample with a Bubbler. Status of Tritium measurements Tritium Measurements Ⅱ

EquipmentEquipment MethodsMethods OperatorOperator Needs of the equipment development Ⅲ

MethodsMethods ▣ Bubbler can sample only one point with a bubbler. ▶ Sampling of multiple points need with a bubbler. ▶ During sampling at the same point, it needs a equipment that able to automatic sample with the setting time. ▣ During the abnormal situation, Operator increase to sample because of the sampling interval time is shorter. Needs of the equipment development Ⅲ

▣ Busy Outage and equipment contamination can cause a lack of equipment. ▶ Equipment needs multiple sampler line and requires a self-cleaning function. ▶ Need the sampling time storage function. ▣ Equipment itself does not record the sampling time. EquipmentEquipment Needs of the equipment development Ⅲ

EquipmentEquipment ▣ The unexpected setting change of flow meter(LPM) can cause the sampling volume change. ▶ Need the automatic correction features in accordance with the change of flow rate(LPM). ▶ Need Sampling reservation function. ▣ No Sampling reservation function. Needs of the equipment development Ⅲ

Main controller Sample selector BubblerBubbler Prototype of the Sampler Automatic Multiple Tritium Sampler(AMTS) Ⅳ

Configuration of the Sampler Automatic Multiple Tritium Sampler(AMTS) Ⅳ Solenoid valve Operation Display LED Control signals Clean air Bubbler Sample selector Main controller Purge out

Sample point 4 Sample point 3 Sample point 2 Sample point 1 Solenoid valve Operation Display LED Control signals Work flow of the Sampler Automatic Multiple Tritium Sampler(AMTS) Ⅳ Purge out Clean air Sample selector Bubbler Main controller

8 Bit Microprocessor with Watchdog Timer 32 kbyte EEPROM, 8 kbyte SRAM 12 Bit A/D 4 Channel, 12 Bit D/A 2 Channel 8 key Input (cursor movement, decrease, return, action) 240 x 64 Pixel Graphic LCD with LED Back Light Real Time Clock Chip (Back Up Battery life 10 years) 10 Port Samples Selector Control (Power transistor driven by the relay) Bubbler Control of Photo Coupler (work orders, stop orders, work situation ) Main Controller Specifications Automatic Multiple Tritium Sampler(AMTS) Ⅳ

4 Input Port + 1 Clean Air Port, 4 Out Port + 1 Purge Air Port Path selection by solenoid valves (DC + 24V powered) Power transistors, driven by a relay (10 Port) Sampling Air Selector Photo Coupler automatically controlled by the Bubbler Subject made by the purge, stabilization, bubbling, automatically perform a clean operation 10 Liter Air Sampling (3 Liter Per Minute Sampling Speed)BubblerBubbler Specifications Automatic Multiple Tritium Sampler(AMTS) Ⅳ

AMTS Test 1 – Continuous Measurements ▣ The time required for 4 points sampling with one Bubbler (Sampling time = 10minutes / sampling x 4sampling = 40minutes) ◈ The necessary time applied with AMTS (Sampling time = 6minutes / sampling x 4sampling = 24minutes) ▶ 16 minutes shorter Application Tests at Local Point Automatic Multiple Tritium Sampler(AMTS) Ⅳ

AMTS Test 1 – Continuous Measurements ▣ The time required for 4 points sampling with two Bubbler (Sampling time = 10minutes / 2bubbler x 4sampling = 20minutes) ◈ The necessary time applied with AMTS (Sampling time = 6minutes / 1bubbler x 4sampling = 24minutes) ▶ Two bubbler effects Application Tests at Local Point Automatic Multiple Tritium Sampler(AMTS) Ⅳ

AMTS Test 2 – Time settings ▣ To reduce Sampling Error – Sampling time (Time on/off by operator – human error) ◈ AMTS sampling program - Sampling start at scheduled time ( 30 minutes, 1 hour …) → Automatically purge and self-cleaning ▶ Realization and reliability of unmanned automated collection Application Tests at Local Point Automatic Multiple Tritium Sampler(AMTS) Ⅳ

Save the Sampling time With the developed equipment, it shows two equipment effects with one bubbler. With the developed equipment, it shows two equipment effects with one bubbler. Standardization Of Sampling Procedures Standardization Anyone who has a certain time can sample in the same way. Anyone who has a certain time can sample in the same way. Unmanned automation After the initial setup, all sampling can obtain automatically without people. Also, operators can do any other tasks and services. After the initial setup, all sampling can obtain automatically without people. Also, operators can do any other tasks and services. Unmannedautomation Save the Samplingtime Automatic Multiple Tritium Sampler(AMTS) Ⅳ Standardization Of Sampling Procedures Procedures

When tritium sampling at the several area in Radiation Control zone, it expects the shorter time to sample with the AMTS. it expects the shorter time to sample with the AMTS. More then 2 sampling positions can concentrate a sampling position. The more effects the tritium concentration surveillance. The more effects the tritium concentration surveillance. With the reservation function of AMTS, it is possible to sample and to purge periodically according to the setting time and the setting procedure. Conclusions & Expectations Ⅴ

When heavy water leakage breaks out, it can sample on the various areas within the shorter time, takes any actions quickly for emergency situation. After the outage, it is possible to observe quickly around the suspected heavy water leak area during the reactor start operation. After the outage of Wolsong Unit #1, it is possible to observe quickly around the suspected heavy water leak point. Conclusions & Expectations Ⅴ

AMTS has a sampling pump, sampling can not be done more than 2 points simultaneously. Consists of the three separated elements, it is difficult to carry on and movement. At the abnormal loss of power, it can be lost all of sampling data. ImprovementsImprovements Future Plans Ⅵ

Simultaneous function Improve the equipment to sample more than 2 points at the same time. Portable function Improve the equipment All- in-one and portable. Future Plans Ⅵ

TAM function Apply TAM function to portable tritium measurement. ⇒ Unmanned automatic tritium measurement. Storage function Improve the program to store the sampling status automatically. Future Plans Ⅵ