Boston University Radiofrequency Safety Training For Charles River Campus and Medical Center Campus Revision 7.0 Office of Medical Physics and Radiation.

Slides:



Advertisements
Similar presentations
AND OTHER ACCESS RESTRICTIONS
Advertisements

CONFIDENTIAL R.S.I. CORPORATION University Based Safety Training Personal Monitors.
CONFIDENTIAL R.S.I. CORPORATION HEALTH EFFECTS RSICORP.COM.
“THE RF SAFETY PROGRAM and TRAINING REQUIREMENTS”
CONFIDENTIAL R.S.I. CORPORATION RF Controlled Exposure Hazards Only Competent People can work in RF C ontrolled Areas.
CHPPM-EUROPE RADIATION PROTECTION DIVISION
RF Safety Program - Guidelines for Compliance - Understanding
September 6, 2014IEEE NJ Coast1 Environmental effects of Wireless radiation K.Raghunandan Construction Administrator (Wireless) Communication Engineering.
Laser Awareness (Non-User). 2 What is a laser? Laser is an acronym for Light Amplification by Stimulated Emission of Radiation.
Boston University Radiofrequency Safety Training For Charles River Campus and Medical Center Campus Revision 4.0 Office of Medical Physics and Radiation.
OSHA Requirements for Tower Construction Related to RF Radiation
Suggested Update to RF Standards Related to Wireless Communications Bob Curtis April 10, 2001.
RF Safety By Bob Buus, W2OD. Certification 6) Amateur Applicant/Licensee certifies that they have READ and WILL COMPLY WITH Section 97.13(c) of the Commission’s.
Occupational Health Introduction to Industrial Hygiene © 2011 Sensible Safety Source LLC.
RF and Microwave Safety A Self-Paced Safety Class Presented By Environmental Health and Safety Cornell University EH&S Rev 1 12/2010.
Introduction to RF and Microwave Systems
PERMIT REQUIRED CONFINED SPACES PERMIT REQUIRED CONFINED SPACES.
ENTRANT, ATTENDANT & QUALIFIED PERSON TRAINING. COURSE OVERVIEW Introduction and Purpose Defining a Confined Space Locations and Types of Confined Spaces.
Chapter 8 Electrical and RF Safety Basic Safety Have a master on/off switch for your station. Don’t work on “live” equipment. Check with a meter first.
Radiation Occupational exposures and protection A. H. Mehrparvar, MD Occupational Medicine department Yazd University of Medical Sciences.
Update of RF Radiation Protection Standards
Cellular Phone Towers Moh. M. Abu Safya School of medicine An-najah N University 23 th.Mar.2011 Supervisor: Dr.samar musmar 1.
GSC: Standardization Advancing Global Communications Resolution GSC-10/05: (GRSC) Facilitating Liaison in Relation to Measurement Methodologies for Assessing.
OSHA REGULATION FOR RF RADIATION EXPOSURE Bob Curtis US OSHA Directorate of Technical Support.
Benzene Training on the hazards of benzene in the workplace Developed by the Division of Occupational Safety & Health (DOSH) for employee training May,
STFC SHE Group Corporate Services This code should be read by: All STFC staff, tenants who are responsible for equipment or facilities generating strong.
Radio Frequency Safety. Purpose Provide: Basic Technical Understanding Overview of FCC Regulations and Compliance Issues Hazard Recognition Skills Awareness.
Chapter 10 – Electrical, Antenna Structure and RF Safety Practices
RADHAZ Material Outline Introduction and Background Standards and Applications Prediction of Electromagnetic Fields Measurement of Electromagnetic Fields.
DTR/H&D Joint Venture1 Radio Frequency Exposure and Compliance Issues for a Shortwave May 2008 Matthew W. Folkert, MSEEE Stephen S. Lockwood, P.E. dTR/H&D.
8/27/2015 Your Wireless Phone Safety Strategy Presented by:
Exposure to risks arising from electromagnetic fields Chris Marshman York EMC Services Ltd University of York.
CONFIDENTIAL R.S.I. CORPORATION From: RSI Rooftop Tape.
RF Safety at Wireless Sites
ANALYTICAL X-RAY SAFETY User Training Centre for Environmental Health, Safety and Security Management.
1 Integrating ANSI-Compliant RF Signs into Corporate RF Safety Programs David Maxson NAB 2004.
1 INTERNATIONAL TELECOMMUNICATION UNION Telecommunications Development Bureau (BDT) REGIONAL OFFICE FOR AFRICA EMF ENVIRONMENTAL CHARACTERIZATION OVERVIEW.
Technician License Course Chapter 9 Lesson Module 21 Radio Frequency Exposure.
Introduction to Radio Frequency Radiation Robert Curtis, USDOL/OSHA Directorate of Science, Technology and Medicine March 2003.
Radioactive Materials Awareness Radiation Safety Training.
TELECOMMUNICATIONS Dr. Hugh Blanton ENTC 4307/ENTC 5307.
Radiation Safety Plan Recommended by OSHA Elements of Plan  Site Specific Issues  Personnel Training  Safety Procedures  Definition of Controlled and.
Chapter 11 Safety Gordon, AH6DA. Safety Three Hazardous materials: – PCBs (polychlorinated biphenyls) insulating oil used in electronic gear. (Transformers,
Laser and Radiation Access for Facilities Division Workers.
EMF Directive 2013/35/EU Introduction All employers have a duty to assess risks arising from work undertaken and to put in place.
Cellular Phones by Juhan Rebane Topics  What is a cellular phone ?  How it works ?  What do it consists of ?  Student´s consumption.  What.
Fall Protection Training. - Falls remain the number one cause of fatalities in the construction industry. FALL PROTECTION FACT!!!
Accelerator Safety Workshop SLAC John Blaikie Health Physics Program Manager – SC Office of Science, U.S. Department of Energy Access Control and.
 A medium that provides a means for transferring energy from one place to another  It is not expensive or difficult to control the risk of an electrical.
The Plain Facts About Electric System Radio Signals An Advanced Mesh Network SmartMeter™ electric meters include two low power radio frequency (RF) transmitters.
Electrical and RF Safety. Electrical Safety Generators Generators convert mechanical energy to electrical energy. They actually consist of two devices:
RF Exposure and Limits A Basic Overview. Background Recent developments in the electronics industry have led to the widespread use of radio frequency.
M O N T E N E G R O Negotiating Team for the Accession of Montenegro to the European Union Working Group for Chapter 28 – Consumer and Health Protection.
Work Place Committees and Health and Safety Representatives Training Module 5 – INPECTIONS, WORK PLACE HAZARDS, TASK HAZARD ANALYSIS.
Radio Frequency (RF) Safety When Working Near Cellular Antennas
Microwave Antennas and Propagation.
Boston University Radiofrequency Safety Training
NIR Safety Awareness Module 3: NIR Standards. NIR Safety Awareness Module 3: NIR Standards.
Cell Phone Tower Proposal: Comparison – for discussion
Senior Program Director
Lecture 4 January 25, 2017 Two Reference Formats.
GSM Base Station Antennas
This code should be read by:
Lecture 3 Assignment 1. In addition to reading through Chapter 1 , read one paper on the exposures that you get from a low frequency source and write.
WELCOME.
What type of radiation are VHF and UHF radio signals?
NATE Tower Site Hazard Recognition Guide
Phenotyping Facility X-ray Awareness Training
RADHAZ Joint Spectrum Center E3 & Spectrum Engineering Division, OS35
Presentation transcript:

Boston University Radiofrequency Safety Training For Charles River Campus and Medical Center Campus Revision 7.0 Office of Medical Physics and Radiation Safety

Why is training Needed? To inform and train workers to recognize potential areas of RF exposure BU RF Training Program Work site safety mindset: Workers should be familiar with RF safety if exposures due to RF are possible. Revision 7.0 Office of Medical Physics and Radiation Safety

Revision 7.0 Office of Medical Physics and Radiation Safety Radiofrequency (RF) Radiation Radiofrequency (RF) Radiation” refers to the electromagnetic fields with frequencies between 300 kHz and 300 GHz, often extending the lower-frequency boundary of RF radiation to 10kHz, or even to 3 kHz in order to include emission from commonly used devices. RF radiation is produced by devices such as radio and TV transmitters, Pager Antennas, induction heaters, and dielectric heaters (also known as RF sealers).

Revision 7.0 Office of Medical Physics and Radiation Safety SourceFrequency (MHz)Potential for Over-exposure? Video Display Terminal (VDT) No Dielectric Heater (typically 27.12) Yes Communications Transmitters: AM Radio Yes Communications Transmitters: FM Radio Yes Communications Transmitters: VHF TV 54-72, 76-88, Yes Communications Transmitters: UHF Radio Yes Communications Transmitters: Dish Antenna ,000Yes CB Radio 27.12Yes Cordless Telephone No Cellular Telephone824 – 850, 900, 1800, and 1900No Traffic Radar10,500 and 24,000No Microwave Oven915 and 2,450No* *Federal legislation requires that microwave ovens be constructed to meet stringent microwave leakage limits and to have safety interlocks. When these interlocks are defeated, for example, during repair work, there is a risk of overexposure to microwave radiation. Common Sources of RF radiation

RF Standards U.S. IEEE/ANSI C RF/MW Exposure limits C Signage and S&H programs C95.3 – Measurement FCC OET Bulletin 65 Massachusetts 105 CMR 122 NONIONIZING RADIATION LIMITS FOR: THE GENERAL PUBLIC FROM NON-OCCUPATIONAL EXPOSURE TO ELECTROMAGNETIC FIELDS, EMPLOYEES FROM OCCUPATIONAL EXPOSURE TO ELECTROMAGNETIC FIELDS, AND EXPOSURE FROM MICROWAVE OVENS Revision 7.0 Office of Medical Physics and Radiation Safety

RF Exposure Standards are Typically Based on 6 min. TWA  Excursions allowed if 6 min time weighted average (TWA) is within limits for occupationally exposed workers (RF workers)  If a worker enters an WARNING area that was surveyed to have greater than 100% of occupational exposure for a 6 minute period, the worker would need to reduce the amount of time spent in the area so that the exposure when taken over the average of 6 minutes is LESS than 100%  Enters zone for 6 minutes -average exposure 100% for that 6 minute period  Leaves zone for 6 minutes -average exposure close to 0% for that 6 minute period  Repeat till work is done – average exposure over 6 minute TWA is approximately 50% exposure, well under the 100% limit for workers.  Up to 30 min intervals used for public exposure standards  Same method as shown below applies for members of the general public in CAUTION areas, but over longer time period and at lower exposure rates Revision 7.0 Office of Medical Physics and Radiation Safety

RF Exposure Exposure to radio frequency (RF) fields results in the absorption of energy in the body The mechanism of this energy transfer is the body acting as an antenna for an RF source (i.e. RF source can be a tower, antenna, guide wire) Revision 7.0 Office of Medical Physics and Radiation Safety

RF effects on the human body If the induced currents are large enough, tissue temperature rises – Tissue Heating Extremely critical in body parts that have limited cooling such as the eyes and testes NO known lasting/long term effects over many scientific studies. At a certain rate of energy absorption biological effects also occur that can result in dizziness and confusion In the case of surface contact a shock hazard is also present In areas of high RF fields, RF energy can interfere with the programming of medical devices such as Cardiac Pacemakers or Cochlear Implants. Revision 7.0 Office of Medical Physics and Radiation Safety

FCC RF Exposure Regulations Environments A controlled environment is one in which the people who are being exposed are aware of the exposure and can take steps to minimize that exposure. An uncontrolled environment is one in which the people being exposed are not normally aware of the exposure. The uncontrolled environment limits are more stringent than the controlled environment limits. Revision 7.0 Office of Medical Physics and Radiation Safety

FCC RF Exposure Regulations Maximum Permissible Exposure (MPE) Regulations are designed to control exposure to RF fields, not the strength of RF fields MPE limits are most commonly specified in: Power density (mWatt/cm 2 ) Revision 7.0 Office of Medical Physics and Radiation Safety

MPE Power Density Limits Occupational/ Controlled General Public/ Uncontrolled.3 to 33 to 3030 to to to HFVHFUHF Revision 7.0 Office of Medical Physics and Radiation Safety

Revision 7.0 Office of Medical Physics and Radiation Safety RF Exposure Limits to Maximum Permissible Exposure (MPE) Occupational WorkerGeneral Public Frequency RangePower Density (mW/cm 2 ) 10 kHz - 3 MHz MHz - 30 MHz900/f 2 180/f 2 30 MHz MHz MHz MHzf/300f/ MHz GHz51

Revision 7.0 Office of Medical Physics and Radiation Safety BU RF Safety Categories based on RF exposure conditions RF Safety Category Exposure Condition Occupational Action Level Public Action Level Control Actions required 1 Operational characteristics of source(s) would not cause the action level to be exceeded. Below 2%Below 10% None, unless changes in equipment since last survey alter category. 2 Operations characteristics of source(s) could cause the action level to be exceeded but would not cause the exposure limit to be exceeded in accessible areas. 2%10% RF Notice Signage posted. 3 Potential to exceed the exposure limit in accessible areas, if mitigating controls are not applied. 20%100% RF Caution and Pacemaker Danger Signage posted, and control to access area is restricted. 4 Exposure will exceed exposure limit in accessible areas. 100%500% RF Warning and Pacemaker Danger Signage posted, Nardalert XT required, and control to access area is restricted.

Revision 7.0 Office of Medical Physics and Radiation Safety Graphical Representation of RF Safety categories

RF Notice Sign(s) Area where public exposure limit MAY be exceeded. RF Category 2 Controlled Environment Excludes the general public. Access should be restricted to general public for standard roof safety issues (locked door, padlocked hatch, etc.) but is not required General Public and Employees should limit time spent in this area. Perimeter of FCC Uncontrolled Limits Revision 7.0 Office of Medical Physics and Radiation Safety

Response to RF Notice Sign(s) What do you do when you see a NOTICE sign? Should not alter your work or job in any way No one is excluded from this area, although it is recommended that both the general public and employees limit their time in this area. Revision 7.0 Office of Medical Physics and Radiation Safety

RF Notice Sign Locations Office of Medical Physics and Radiation Safety Revision 7.0 Picture (right): Antenna on upper penthouse of L Building (72 E. Concord) – exceeds public exposure limits. Rooftop door marked with Notice Sign 72 E. Concord L building 33 Harry Agganis Way Student Village Beacon St. Danielsen Hall 44 Cummington St. Engineering research Building 700 Commonwealth Ave. Warren Tower A 881 Commonwealth Ave. Registrar

RF Caution Sign(s) Area where employee may be exposed, but exposure limit MAY not be exceeded RF Category 3 Controlled Environment –Restricted to the General Public, NOT Occupational workers, provided they have training Awareness Training is Required to access this area Contact Radiation Protection or EHS prior to entering area Perimeter of Controlled Limits indicating need for protective measures (e.g., time averaging) Revision 7.0 Office of Medical Physics and Radiation Safety

RF Caution Sign(s) Revision 7.0 Office of Medical Physics and Radiation Safety What do you do when you see a CAUTION sign? Should not alter your work or job in any way Look for antennas. If you do observe someone who you believe should not be on the roof (general public, lone student not with a group, etc.) ask them if they have taken the RF awareness training, get their name and call EHS or MPRS to verify. If they have not they are classified as General Public, and this area is restricted to them.

RF Caution Sign Locations Office of Medical Physics and Radiation Safety Revision Cummington St. 765 Commonwealth Ave. Law Tower lower level (when main WBUR antenna is energized) 675 Commonwealth Ave. Stone Science Building (Roof Ladder Barricade) 725 Commonwealth Ave BU Astronomy (Roof Stair Barricade) 840 Harrison Ave. Menino (Lower Roof) Picture (right): Antenna on upper corner of Lower Roof on Menino Building (BUMC) – exceeds public exposure limits. Lower level – accessible rooftop is now marked with a Caution Sign

RF Warning Sign(s) Area where employee exposure limit WILL be exceeded RF Category 4 Controlled Environment - Restricted to the General Public, NOT Occupational workers, provided they have training Awareness Training is Required to access this area Contact Radiation Protection or EHS prior to entering area Personal RF dosimeters will be issued by either EHS (CRC) or Radiation Protection (BUMC) Contact Radiation Safety or EHS if you need to work close (within 4 ft.) to RF an source in this area. Time averaging is not feasible to prevent exposures at very High MPE’s Revision 7.0 Office of Medical Physics and Radiation Safety

RF Warning Sign(s) Revision 7.0 Office of Medical Physics and Radiation Safety What do you do when you see a WARNING sign? Call EHS or MPRS to get a key and dosimeter prior to entering the area. WEAR the dosimeter. If it alarms, look at the level and move from the area of exposure. Use TWA 6 min intervals to complete work if need be. Look for antennas. If you do observe someone who you believe should not be on the roof (general public, lone student not with a group, another employee or contractor, etc.) ask them if they have taken the RF awareness training, get their name and call EHS or MPRS to verify. If they have not they are classified as General Public, and this area is restricted to them.

RF Warning Sign Locations Office of Medical Physics and Radiation Safety Revision 7.0 Picture (Right) Antenna on upper corner of Penthouse Roof on Warren Towers (A) (CRC) – exceeds occupational exposure limits. Upper Level – Accessible by ladder on rooftop is marked with a Warning Sign 840 Harrison Ave. Menino (Upper roof) 750 Albany St. Power Plant 700 Comm. Ave. Warren Tower A 765 Comm. Ave. Law tower (Upper rooftop when WBUR antenna is energized)

Pacemaker Danger Signs For areas of occupational exposure where limits exceed public action limits Revision 7.0 Office of Medical Physics and Radiation Safety

Personal Protective Equipment (PPE) For employees that need to access rooftops that are marked RF Safety Category 4 (Warning signs posted) a personal dosimeter called the Nardalert XT will be issued to you by Radiation Protection – Medical Campus (Ext ) EHS – Charles River Campus (Ext ) Revision 7.0 Office of Medical Physics and Radiation Safety

Contact Information Radiation Protection – Medical Campus 72 East Concord Street Evans Basement B EHS – Charles River Campus 704 Comm. Ave. 2 nd Floor After Hours Emergency Medical Campus pgr (ID#3471) Charles River Campus Phone: Radiofrequency Protection Officer Anthony Blatnica Revision 7.0 Office of Medical Physics and Radiation Safety