Instant Notes Analytical Chemistry

Slides:



Advertisements
Similar presentations
OFFLINE COMPOSITION MEASURING SENSORS
Advertisements

Gas Chromatography Introduction 1.) Gas Chromatography
Gas Chromatography 427 PHC.
Lecture 8b Gas Chromatography.
Gas Chromatography.
Gas Chromatography, GC L.O.:  Explain the term: retention time.  Interpret gas chromatograms in terms of retention times and the approximate proportions.
GAS CHROMATOGRAPHY ENVE 202 Dr. Aslıhan Kerç.
Liquid chromatography coupled with Mass spectroscopy
Chapter 20 Molecular Mass Spectrometry Mass spectrometry is capable of providing information about (1) the elemental composition of samples of matter.
Gas chromatography–mass spectrometry (GC-MS) is an analytical method that combines the features of gas-liquid chromatographyand mass spectrometry to identify.
Drug Analysis.
Chromatography.
Chapter 32 HIGH-PERRORMANCE LIQUID CHROMATOGRAPHY High-performance liquid chromatography (HPLC) is the most versatile and widely used type of elution chromatography.
Lecture 8. GC/MS.
Chromatography.
In carbon-13 NMR, what do the number of peaks represent?
Intro to Chromatographic Separations Chap 26. Originally based on separation and identification by color Originally based on separation and identification.
LC/MS WORKSHOP IOWA STATE UNIVERSITY Kamel Harrata  Instrument Description  Data Acquisition  Data Processing.
GC Detectors Ideal Detector Characteristics: 1. Universal Response
Gas Chromatography And Mass Spectrometry
Gas Liquid Chromatography
Gas Chromatography. Gas Chromatography Basics Gas Liquid Chromatography (GLC) Gas Solid Chromatography (GSC) Mobile phase does not interact with analyte.
Types of Chromatography Liquid chromatography versus gas chromatography? Applications? Volatile  GC Non-volatile  LC.
LECTURE 4: CHROMATOGRAPHY Content: - Chromatographic separation - classifying analytical separations; column chromatography, planar chromatography - gas.
By, Blessy Babu. What is Gas Chromatography?  Gas spectroscopy is a technique used to separate volatile components in a mixture.  It is particularly.
5 -1 FORENSIC DRUG ANALYSIS Drug Identification The challenge comes in selecting analytical procedures that will specifically identify a drug. This.
Chemical Analysis. Analytical Techniques When chemical evidence is collected at a crime scene, it must be run through an instrument. These instruments.
Chapter 6 - Chromatography
Chemical Ideas 7.6 Chromatography. The general principle. Use – to separate and identify components of mixtures. Several different types - paper, thin.
Chapter 27 Gas Chromatography 1. Principles
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 22 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
SUPER CRITICAL FLUID CHROMATOGRAPHY
Chromatography Chapter 6.
Magnet Analytical Chemistry Unit 4
CHROMATOGRAPHY. The general name given to methods by which two or more compounds in a mixture are physically separated by distributing themselves between.
By: Thilag.k & Stephen. What is Hpcl??? Hplc or high performance liquid chromatography is the most widely used analytical separation technique. The difference.
Chapter 33 Supercritical-Fluid Chromatography
INSTRUMENTAL ANALYSIS CHEM 4811 CHAPTER 12 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
An Introduction to Chromatography What is chromatography? The separation of a mixture by distribution of its components between a mobile and stationary.
Interfacing Gas Chromatography with Mass Spectroscopy and Infra Red Spectroscopy Is this a large expensive detector…. Or a separation prior to analysis….
Chemistry Topic: Atomic theory Subtopic : Mass Spectrometer.
Gas Chromatography Experiment. Gas Chromatography - Gas Chromatography (GC) is a common technique used to separate and identify volatile organic compounds.
Intensive General Chemistry Chemical separations II Isabelle Vu Trieu
By- Bhavya, Harsh, Harshvardhan, Namrata, Ronit and Vidhatri
Analytical Separations
HPLC – High Performance Liquid Chromatography
Basic Gas Chromatography. History Separation of dyes by Runge Separation of plant pigments by Tswett Theoretical gc (Martin & Synge)
LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY
1 Gas Chromatography Lecture Liquid Stationary Phases In general, the polarity of the stationary phase should match that of the sample constituents.
HPLC.
High Performance Liquid Chromatography
Chromatography and Instrumentation. Chromatography Separate Analyze Identify Purify Quantify Components Mixture Chromatography is used by scientists to:
Presented by – ANAMIKA BANERJEE (RESEARCH SCHOLAR)
Instrumental Analysis
LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS)
1 Principles of Chromatography Chap Analytical Separations and Chemical Problem Solving If you, a researcher of a food company are asked to find.
Experiments in Analytical Chemistry
GC-MS technique & Its application
Chapter 5 – Organic Analysis
Chemical Ideas 7.6 Chromatography.
Organic Instrumentation
Pure Carrier Gas Grades (subjective)
VAPOUR PHASE CHROMATOGRAPHY
Chromatography Daheeya Alenazi.
High-Performance Liquid Chromatography
GAS CHROMATOGRAPHY.
Electron Capture Detectors
High-Performance Liquid Chromatography
Suppose we make a new compound containing of C,H, and N
Presentation transcript:

Instant Notes Analytical Chemistry Section F Combined Techniques D. Kealey & P. J Haines

Contents Gas Chromatography – Mass Spectrometer Gas Chromatography – Infrared Spectrometer Liquid Chromatography – Mass Spectrometer

1.Gas Chromatography – Mass Spectrometer

Principles Instrumentation Applications Related topics The use of Chromatographic Techniques to separate mixtures is one of the most important Analytical Tools. The separated components may then be identified by other techniques. Mass Spectrometry is the most important of these. Instrumentation Combining Gas Chromatography with Mass Spectrometry requires special methods of Interfacing since the Two Techniques Operate under Different Conditions. Applications Gas Chromatography-Mass Spectrometry has been used to study the Separation and Identification of volatile mixtures such as Natural Products, Crude Oils and Environmental Samples. Related topics Gas Chromatography: Principles Mass Spectrometry (E14) Instrumentation (D4) Gas Chromatography: Procedure Sand Applications (D5)

Principles (1) The operating temperature range of instrument ☞ Room Temperature ~ 400℃ The separated components may be classified according to their Retention times or by Chromatography spiked sample. Solutes may be ionized by Electron Impact or Chemical Ionization

Principles (2) Gas Chromatography

Principles (3) Mass Spectrometer

Instrumentation(1) Gas Chromatography’s detection by Flame Ionization Detector(FID) or one of the other GC detector is possible. GC/MS is then necessary to reduce the pressure to operating pressure of Mass Spectrometer ☞ 10-8Nm-2 The flow of carrier gas is small ☞ through a fine capillary GC column directly into Mass Spectrometer

Instrumentation (2) For packed column, an Interface between the GC and MS is required. ☞ Porous Tube Separator or Jet Separator The interface should be maintained at the temperature of GC outlet A Quadruple Analyzer are very often used because of their ability to scan rapidly

Instrumentation (3) Fig1. (b) Jet separator

Instrumentation (4) Fig 1. (a) Schematic of a GC-MS system

Instrumentation (5) Total Ion Current(TIC) Selected Ion Monitoring(SIM) ☞ By selecting a particular m/z ratio

Applications (1) A mixture of six fragrance components, injected as 5 ㎕ of a solution in ether. Fig 2. TIC Chromatography of fragrance mixture using a BP – 1. nonpolar capillary column direct injection and MS

Applications (2) Table 1. Mass spectrometric peaks for peak at 160 s

Applications (3) Fig 3. Mass spectrum for the peak at 119 s

2.Gas Chromatography – infrared Spectrometer

Principles Instrumentation Applications The use of Chromatographic Techniques to separate mixtures is one of the most important Analytical Tools. The separated components may be classified by their Retention Times, but other Techniques should be used to aid identification. Infrared Spectrometry is capable of establishing which Functional Groups are present in the separated components Instrumentation Combining Gas Chromatography with Infrared Spectrometry involves passing the solutes in the Carrier Gas Stream through a heated Infrared Gas Cell positioned in a rapid scanning Fourier Transform Spectrometer. Applications Gas chromatography-Fourier transform infrared spectrometry has been employed in the analysis of Biological Materials such as Fragrances, to determine the proportions and nature of each component, of Solvents to determine their purity and composition, and to Identify the evolved products when substances are degraded by heating. Related topics Gas chromatography : principles and Infrared and Raman spectrometry : instrumentation (D4) Principles and Instrumentation Gas Chromatography : procedures and (E10) applications (D5) Infrared and Raman Spectrometry : applications (E11)

Principles (1) Identification of the separated solutes by their Retention Time alone is often ambiguous. Infrared Spectrometry is a very powerful and versatile technique for the identification of Function group. Using computerized Fourier transform processing of Spectral Information.

Principles (2)

Instrumentation (1) The greater sensitivity of modern FTIR have allowed the use of Capillary Columns. Typically, a 30m long, 0.3mm diameter fused Silica Column coated with a 1-㎛ thickness of Stationary Phase may be employed. The Gas Stream is therefore usually split at the Column exit so that 90% goes onto the Spectrometer and only 10% to the FID

Instrumentation (2) To obtain the maximum response it is necessary to do one of two thing 1. The sample must be concentrated by condensation onto a cooled surface or by absorption 2. If the sample is to remain gaseous, it must be passed through a small volume cell, or light pipe.

Instrumentation (3) Fig 1. gas Chromatography-infrared Spectrometer system

Application (1) A gas chromatogram obtained from a few microliters of a 12 – component mixture Peak 1 Fig 2. gas Chromatography of an unknown mixture

Application (2) Fig 3. IR spectrum of peak 1.

3. Liquid Chromatography – Mass Spectrometer

Principles Instrumentation Applications Related topics The components of a mixture, after separation by Liquid Chromatography. may be identified and quantified by Mass Spectrometry. Instrumentation The removal of the Liquid mobile phase, while allowing the analytes to be transferred to the Mass Spectrometer has presented difficulties, and the design of the Interface is critical. Applications The analysis of mixtures of Pharmaceuticals and Drugs, the detection of degradation pathways using Isotopic Labeling, and the separation and analysis of Peptides using Soft Ionization Methods are typical of the application of LC-MS. Related topics High-performance liquid Mass spectrometry (E14) chromatography: modes, procedures and applications (D7)

Principles (1) Mobile phase Pump Injector Detector Computer

Principles (2) Since these employ Liquid mobile phases, sometimes containing Inorganic salts, the most difficult problem ☞ How to transfer separated component to Mass Spectrometer without interference from the Solvent

Instrumentation (1) The Interface between the Liquid Chromatography and Mass Spectrometer is the most vital part of the Combined Instrument. Atmospheric Pressure Chemical Ionization (APCI) ☞ Nitrogen is introduced to nebulize the Mobile phase producing an Aerosol of Nitrogen and Solvent Droplets which are passed into a heated region Desolvation occurs, and Ionization is achieved by Gas phase Ion-molecule reaction at Atmospheric, Electrons and the primary Ions being produced by Corona Discharge

Instrumentation (2) The pressure is close to Atmospheric, the Collision frequency is high and Pseudomolecular Ions are formed with high efficiency by Chemical Ionization. Electrospray (ES) ☞ Operating at Atmospheric, the Liquid mobile phase is ejected from a Metal Capillary Tube into an Electric Filed obtained by applying a potential difference of 3 ~ 6 ㎸ between the Tube and a counter Electrode.

Instrumentation (3) Fig 1. Electrospray (ES) interface

Applications (1) The detection of impurities in synthesized drugs Fig 2. (a) TIC chromatogram of dug sample

Applications (2) Fig 2. (b) Mass spectrum of dug impurity