1 Sébastien Boutet 1 Coherent X-ray Imaging Instrument FAC Meeting, June 9 2009 Coherent X-ray Imaging Instrument Sébastien Boutet.

Slides:



Advertisements
Similar presentations
Thomas Stalcup June 15, 2006 Laser Guidestar System Status.
Advertisements

Research Opportunities at LCLS September 2011 Joachim Stöhr.
Tom Fornek LUSI 12 November 2008 SLAC National Accelerator Laboratory 1 LUSI Status Update Tom Fornek Project Manager.
1 John Arthur 1 FEH Status CXI Review June 3, 2009 FEH Layout, Status John Arthur – LCLS Expt’l Facilities Div June 3, 2009.
Tom Fornek LUSI June 17, LUSI UPDATE – June, 2008.
Richard M. Bionta XTOD July 19-21, 2005 UCRL-PRES-xxxxxx X Ray Diagnostics LCLS FAC Meeting Oct. 27, 2005.
Stefan Moeller XES FAC Review – April 16, 2006 X-Ray Endstation Systems (XES) Status Stefan Moeller.
John N. Galayda LCLS Facility Advisory November 11, LCLS Update November 11, 2008 Construction Status LCLS Instruments.
John Arthur X-ray November 11, 2008 SLAC National Accelerator Laboratory 1 X-ray Overview LCLS Directorate structure.
Richard M. Bionta XTOD October 12, 2004 UCRL-PRES-XXXXX X Ray Transport, Optics, and Diagnostics, Overview Facility Advisory Committee.
Stefan Moeller Revised XES April 7, 2005 Revised X-Ray Endstation Scope Stefan Moeller.
J. B. Hastings LUSI Overview LCLS FAC March 20, 2007 LUSI Overview J. B. Hastings January 2007 Lehman Review Response to Lehman Review.
David Fritz LCLS FAC Meeting Oct. 30, X-ray Pump-Probe Instrument David Fritz Instrument Overview Instrument Layout System.
J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging Coherent Single Particle Imaging (WBS 1.3) J. B. Hastings*
1 Stefan Moeller 1 AMO Instrument Schedule ARR AMO Instrument Schedule Stefan Moeller – XES Manager June 30, 2009.
LCLS Studies of Laser Initiated Dynamics Jorgen Larsson, David Reis, Thomas Tschentscher, and Kelly Gaffney provided LUSI management with preliminary Specifications.
Aymeric Robert XCS 11/12/2008 SLAC National Accelerator Laboratory 1 X -ray C orrelation S pectroscopy Instrument Aymeric.
John Arthur Photon Systems April 16, LCLS Photon Systems Status Technical status and accomplishments Response to.
X Ray Transport / Optics / Diagnostics Overview Richard M. Bionta Facility Advisory Committee Meeting April 29, 2004 Richard M. Bionta Facility Advisory.
CXI Sébastien BOUTET CXI Reference Laser System Preliminary Design Review WBS Sébastien Boutet – CXI Instrument Scientist.
John Arthur Photon October 18, 2005 LCLS Photon Systems Status John Arthur SLAC.
John Arthur Photon October 27, Photon Systems Overview John Arthur SLAC.
Abstract A new ultrahigh-resolution photoemission electron microscope called PEEM3 is being developed at the Advanced Light Source. An electron mirror.
John Arthur Photon April 20, 2006 Photon Systems Update John Arthur SLAC Photon Systems Manager.
Eliazar Ortiz LUSI Diagnostics & Common November 11-13, 2008 SLAC National Accelerator Laboratory 1 Diagnostics/Common Optics:
1 Michael Rowen 1 SXR Instrument FAC SXR Instrument Michael Rowen – Engineering Physicist June 9, 2009.
XCS Aymeric ROBERT 1 LUSI X-ray Correlation Spectroscopy Instrument Advanced Procurement Review : Large Angle Detector Mover.
Sébastien Boutet LCLS FAC June Coherent X-Ray Imaging 1 LUSI Coherent X-ray Imaging Instrument Sébastien Boutet – CXI.
Sébastien Boutet LCLS FAC Meeting Oct 30, 2007 Coherent X-ray Imaging1 Coherent X-ray Imaging Instrument Sébastien Boutet Coherent.
Richard M. Bionta X-Ray Transport, Diagnostic, & Commissioning September 22, 2004 UCRL-PRES Two Problems... LCLS Diagnostics.
David Fritz XPP June 17, The X-ray Pump-Probe Instrument Instrument Scientist: David Fritz Second Scientist:
1 T. Fornek 1 LUSI CXI FIDR June 3, 2009 Thomas Fornek Project Manager June 3, 2009 LUSI Coherent X-Ray Imaging Instrument Final.
1 T. Fornek 1 LUSI XCS FIDR June 17, 2009 Thomas Fornek Project Manager June 17, 2009 LUSI X-Ray Correlation Spectroscopy Instrument.
John Arthur X-ray April 20, 2006 X-Ray Beamline and Experiment Layout John Arthur LCLS Photon Systems Manager.
John Arthur Photon October 12, Photon Systems Update John Arthur SLAC 1.
R. M. Bionta SLAC November 14, 2005 UCRL-PRES-XXXXXX LCLS Beam-Based Undulator K Measurements Workshop Use of FEL Off-Axis Zone Plate.
Michael Rowen LCLS FAC November 12, 2008 The SXR Instrument The SXR is a instrument for Soft X-ray Materials Research on.
J. B. Hastings LUSI DOE Review July 23, 2007 X-ray Optics 1 X-ray Optics J. B. Hastings Beam definition Attenuators Slits Pulse picker.
Status of LCLS A. Brachmann, SLAC National Accelerator Laboratory.
Understanding typical users for this instrument Graduate studentGraduate student –not an X-ray expert but wants to make a spatially resolved measurement;
Frontiers of THz Science ZX Shen SLAC Chief Scientist 1.
Update on Laser Beam Lines Christoph Hessler, Mikhail Martyanov, Valentin Fedosseev (CERN laser team)‎ Thanks to M. Battistin, N. Chritin, F. Galleazzi,
John N. Galayda DESY October 8, LCLS Commissioning in 2008 J. Galayda, for The LCLS Construction/Commissioning.
Diamond Radiator Fabrication and Assessment Brendan Pratt Fridah Mokaya Richard Jones University of Connecticut GlueX Collaboration Meeting, Jefferson.
Aidan Brooks, Peter Veitch, Jesper Munch
LCLS Facility Planning for LCLS-II. 2 LCLS vs. LCLS-II NowHXU - CuSXU - CuHXU - SCSXU - SC Photon Energy Range (eV)
IPBSM Operation 11th ATF2 Project Meeting Jan. 14, 2011 SLAC National Accelerator Laboratory Menlo Park, California Y. Yamaguchi, M.Oroku, Jacqueline Yan.
Shielding review for temporary spectrometer for RUBICON experiment, ATF beamline #2 K. Kusche, M. Fedurin RSC meeting, Jan 20, 2015.
Sébastien Boutet LUSI DOE Review July 23, 2007 CXI (WBS 1.3) 1 Coherent X-ray Imaging (WBS 1.3) Sébastien Boutet System Specifications.
Sébastien Boutet LUSI DOE Review July 23, 2007 WBS 1.3 Breakout1 Coherent X-ray Imaging (WBS 1.3) Sébastien Boutet System description.
J. B. Hastings LUSI DOE Review July 23, 2007 X-ray Optics 1 X-ray Optics J. B. Hastings Beam definition Attenuators Slits Pulse picker.
S. Boutet P. Montanez LUSI DOE Review August Coherent X-Ray Imaging (WBS 1.3) 1 LUSI Coherent.
UNIT-3 ADVANCES IN METROLOGY
Coherent X-ray Imaging Instrument
X-ray Correlation Spectroscopy (WBS 1.4) Aymeric Robert
Experimental Facilities Planning
LUSI Diagnostics & Common Optics WBS 1.5
X-ray Pump-Probe Instrument
Coherent X-ray Imaging WBS 1.3
X-ray Pump-Probe Instrument
X-Ray Transport, Optics, and Diagnostics WBS Alan J
Diagnostics Richard M. Bionta, LLNL April 24, 2002
X-ray Pump-Probe Instrument
Coherent X-ray Imaging Instrument WBS 1.3
X-ray Correlation Spectroscopy Instrument
LUSI Status and Early Science
X-Ray Endstation Systems (XES) 2006 Schedule
Considerations about triangular and L-shaped detectors
LCLS Photon Systems Overview
LUSI Controls and Data Systems W.B.S. 1.6
Presentation transcript:

1 Sébastien Boutet 1 Coherent X-ray Imaging Instrument FAC Meeting, June Coherent X-ray Imaging Instrument Sébastien Boutet CXI Instrument Scientist June 9, 2009

2 Sébastien Boutet 2 Coherent X-ray Imaging Instrument FAC Meeting, June Outline Update since the last FAC KB mirrors New CXI layout Sample Chamber/KB mirror integration for the 0.1 micron focus

3 Sébastien Boutet 3 Coherent X-ray Imaging Instrument FAC Meeting, June Coherent Diffractive Imaging of Biomolecules Combine many measurements into 3D dataset Noisy diffraction pattern LCLS pulse Particle injection One pulse, one measurement Wavefront sensor or second detector Data Frames Combined Data SetReconstruction

4 Sébastien Boutet 4 Coherent X-ray Imaging Instrument FAC Meeting, June CXI Instrument Location XCS AMO CXI Endstation XPP Near Experimental Hall Far Experimental Hall X-ray Transport Tunnel Source to Sample distance : ~ 440 m SXR

5 Sébastien Boutet 5 Coherent X-ray Imaging Instrument FAC Meeting, June Far Experimental Hall Coherent X-ray Imaging Instrument CXI Control Room Lab Area X-ray Correlation Spectroscopy Instrument Hutch #6 XCS Control Room

6 Sébastien Boutet 6 Coherent X-ray Imaging Instrument FAC Meeting, June CXI Instrument Overview Sample Chamber Detector Stage (back position) Particle injector LCLS Beam Precision Instrument Stand Detector Stage (upstream position)

7 Sébastien Boutet 7 Coherent X-ray Imaging Instrument FAC Meeting, June CXI KB Mirrors CXI has two sets of KB mirrors to produce a 1 micron beam and a 0.1 micron beam Discussed at last FAC Coating 45 degree geometry Update Apply single coating strip (SiC) But leave space for at least another strip for later The 45 degree geometry was abandoned Benefits were not worth the risks

8 Sébastien Boutet 8 Coherent X-ray Imaging Instrument FAC Meeting, June New CXI Layout Discussed at last FAC Put both sample chambers in series and have each KB system focus at different planes Put KB1 system first and focus past the KB0.1 system Place Be lenses between the 2 sample chambers to refocus the 100 nm beam into the second sample chamber Keep ability to use the unfocused beam Update The new layout was implemented The unfocused beam can be used in the 1 micron Sample Chamber

9 Sébastien Boutet 9 Coherent X-ray Imaging Instrument FAC Meeting, June CXI with 1 micron and Unfocused Beam Diagnostics & Wavefront Monitor 1 micron Sample Environment Diagnostics/ Common Optics 1 micron KB Reference Laser

10 Sébastien Boutet 10 Coherent X-ray Imaging Instrument FAC Meeting, June CXI with 0.1 micron Beam Diagnostics/ Common Optics 1 micron KB Reference Laser 0.1 micron KB & Sample Environment Wavefront Monitor

11 Sébastien Boutet 11 Coherent X-ray Imaging Instrument FAC Meeting, June New Layout Advantages Allows serial experiment configuration Allows separation of mirror vacuum Allows the use of a thin window to separate KB0.1 mirror vacuum from 0.1 micron sample chamber Allows the second chamber to be removed without disturbing the mirrors Allows a user chamber to be attached if needed

12 Sébastien Boutet 12 Coherent X-ray Imaging Instrument FAC Meeting, June CXI 0.1 µm KB Mirrors/Sample Environment Purpose Produce a ~100 nm focus Focal lengths 0.9 m for M1 0.5 m for M2 Requirements Identical to 1 micron KB System in every way except for the mirror curvature Integrated system with 0.1 micron Sample Chamber due to close proximity Extend vacuum enclosure by ~600 mm for sample area Separate both parts of the vacuum enclosure with valve and window

13 Sébastien Boutet 13 Coherent X-ray Imaging Instrument FAC Meeting, June micron KB/Sample Chamber

14 Sébastien Boutet 14 Coherent X-ray Imaging Instrument FAC Meeting, June micron KB/Sample Chamber

15 Sébastien Boutet 15 Coherent X-ray Imaging Instrument FAC Meeting, June micron KB/Sample Chamber

16 Sébastien Boutet 16 Coherent X-ray Imaging Instrument FAC Meeting, June Custom Valves 2 custom valves will be used First one will hold vacuum in order to vent the Sample Chamber Second valve will have a very thin x-ray transmissive window to separate UHV in KB tank from poor vacuum (~10 -7 Torr) in Sample Chamber

17 Sébastien Boutet 17 Coherent X-ray Imaging Instrument FAC Meeting, June Summary The CXI KB mirrors will use a SiC coating strip Space will be left available for another coating strip once some LCLS experiments have occurred Use 2 sample chambers One for each KB mirror pair CXI abandoned the 45 degree KB mirror configuration Maintain the ability to use the direct unfocused beam into the 1 micron Sample Chamber The 0.1 micron KB/Sample Chamber System will utilize custom valves to allow venting of the Sample Chamber and a thin window to separate the vacuum of the mirrors from the sample