Unsharpness Calculations and Resolution By Professor Stelmark.

Slides:



Advertisements
Similar presentations
DIGITAL RADIOGRAPHY.
Advertisements

CT Scanning: Dosimetry and Artefacts
Image Quality Bushong Chapter 7.
IMAGE QUALITY.
Digital Camera Essential Elements Part 1 Sept
Chapter 18 Radiographic Exposure
Components of Radiographic Image Quality
Radiographic Quality Chapter 5.
Quality Assurance and Digital Radiography
Digital Radiography.
Resident Physics Lectures
RAD 354 Chapt. 28 The Digital Image Spatial resolution Contrast resolution Contrast-detail curve Pt. dose considerations.
MAMMO QC – covered in week 8
Part II Image Quality 1  Image Quality  Photographic Quality  Geometric Quality 2.
Technical Factors or Prime Factors
Dr. Mustafa Zuhair Mahmoud Mr.Ali B Alhailiy بسم الله الرحمن الرحيم 1.
Digital Image Manipulation I By Professor Stelmark.
Computed Tomography III
Chapter 15 Radiographic Intensifying Screens And Cassettes
CIS 681 Distributed Ray Tracing. CIS 681 Anti-Aliasing Graphics as signal processing –Scene description: continuous signal –Sample –digital representation.
Motion Unsharpness By Prof. Jarek Stelmark. MOTION UNSHARPNESS Motion of the tube, part, or image receptor causes a profound decrease in recorded detail.
X-Rays and CT Scans.
 QC testing of screen speed should occur on acceptance and then yearly.  Evaluate first whether similar cassettes marked with the same relative speed.
Conventional and Computed Tomography
Photography Parts of a Camera. Aperture size (or width or diameter) of the opening of a lens diaphragm inside a photographic lens regulates the amount.
How the Camera Works ( both film and digital )
Seeram Chapter 11: Image Quality
Digital Image Characteristic
Image Characteristics. What is an image? Dictionary meaning An optical appearance An optical appearance A form of semblance A form of semblance A mental.
Control of Scatter Radiation
Computers in Imaging Q & A Robert Metzger, Ph.D..
Quality Control.
Spot Filming Cinefluorography Fluoro Room Shielding Radiation Areas.
IMAGE QUALITY REVIEW RT
Dr Mohamed El Safwany, MD.
Image Quality Radiographic Resolution.
Geometric Factors Focal Spot Object Film Object b a h c Film B A H C
Prime Exposure Factors 1
Factors affecting CT image RAD
1 INTRODUCTION TO THE PHYSICS OF DIAGNOSTIC IMAGING Outline of Course Brief History Common Terminology Imaging Modalities.
DIGITAL IMAGE PROCESING NASA LUNAR AND PLANETARY EXPLORATION.
B ASIC P HYSICS OF D IGITAL R ADIOGRAPHY By : Maisa Alhassoun
PRINCIPLES OF TECHNIQUE AND EXPOSURE
Radiographic Quality Visibility and Sharpness
Image Quality Q&A. RAPHEX Diagnostic Question 2001 D9: The imaging system which is best for visualizing small high contrast objects is: A. Computed tomography.
Image Production and Evaluation NOTE: QA AND QC ARE USED INTERCHANGABLY IN APPLETON AND LANGE.
Image Quality The capacity to define, measure, and assess image quality is a primarily responsibility of a CT Technologist.
CT QUALITY MANAGEMENT. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.
Part No...., Module No....Lesson No
RAD 254 Chapter 27 Digital Fluoroscopy
Image Receptor Unsharpness By Professor Stelmark.
By Prof. Stelmark. Digital Imaging In digital imaging, the latent image is stored as digital data and must be processed by the computer for viewing on.
RADIOGRAPHIC QUALITY S. Guilbaud, Education Director School of Radiologic Sciences.
IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.
Diagnostic Radiology II X-ray Tubes. Anode angle Anode angle defined as the angle of the target surface with respect to the central ray in the x-ray field.
Chapters 21 & 22.
Imaging Characteristics
Impact of Obesity on Medical Imaging and Image-Guided Intervention
Distributed Ray Tracing
Quality Control Testing of Screen Speed
Distributed Ray Tracing
Resident Physics Lectures
Camera Basics Digital Photography.
RECORDED DETAIL.
Image Production and Evaluation
Fluoroscopic Image Quality Considerations
Digital Fluoroscopy PPT created by: Jed Miles, BSRS, RT(R), CRT-CA
RECORDED DETAIL.
Distributed Ray Tracing
Presentation transcript:

Unsharpness Calculations and Resolution By Professor Stelmark

Source-to-object distance (SOD) refers to the distance from the x-ray source (focal spot) to the object being radiographed. SOD can be expressed mathematically as follows:

OID = The distance between the object (area of interest) and the image receptor SOD = The distance between the focal spot (source) and object (area of interest) SOD = SID−OID Focal spot size FSS = Dimensions of the nominal focal spot in millimeters (mm )

Image 1Image 2 Focal spot size=0.6 mm SID=40 inches OID=0.25 inch Focal spot size=1.2 mm SID=56 inches OID=4.0 inches Geometric unsharpness of Image 1=0.004 mm Geometric unsharpness of Image 2=0.09 mm Image 2 has the greater amount of unsharpness. Calculating Geometric Unsharpness The amount of geometric unsharpness can be calculated for each of the following images to determine which image has more geometric unsharpness.

SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE TEMPORAL RESOLUTION

SPATIAL RESOLUTION The degree of sharpness in the image The degree of blurring in the image Spatial resolution (also known as high-contrast resolution) is the ability of an imaging system to create separate images of closely spaced high-contrast (black and white) objects (as with contrast resolution, spatial resolution also applies to all imaging modalities). In other words, do the two objects appear sharp and clear, or do they blur together?

The spatial resolution is specified in terms of line pairs per centimeter (lp/cm) or line pairs per millimeter (lp/mm). A line pair is a pair of equal-sized black- white bars. The number of line pairs in digital imaging is specified as spatial frequency. 7 lp/mm 11 lp/mm 17 lp/mm

The most common method of measuring spatial resolution is to use a value known as spatial frequency. The unit of spatial frequency is the line pairs per millimeter (lp/mm) and is obtained with a resolution chart (Fig. 3-13). A line pair includes an opaque line and a radiolucent space. In the resolution chart, one lp/mm would have a 0.5 mm lead bar separated by 0.5 mm of radiolucent material. Two lp/mm would have 0.25 mm lead bars separated by 0.25 mm of radiolucent material and so the greater the lp/mm value, the smaller the object that can be imaged and the better the spatial resolution. The limiting spatial resolution (also known as the Nyquist frequency) is the maximum number of lp/mm that can be recorded by the imaging system. The resolving power of the unaided human eye is approximately 30 lp/mm when inspecting an image up close, and at normal reading distance (about 25 cm), it is about 5 lp/mm.

Imaging SystemLimited Spatial ResolutionSmallest Object Resolved Analog non screen film system50 – 100 lp/mm Analog screen film system6 -10 lp/mm Computed Radiography (CR)2-5 lp/mm Digital Radiography (DR)8-10 lp/mm

SPATIAL FREQUENCY- 15 lp/mm. WHAT IS THE SMALLEST SIZE OF AN OBJECT THE IMAGING SYSTEM CAN RESOLVE 1/15 = 0.06 mm/lp 0.06 /2 = 0.03 mm object

Spatial Resolution Influencing Factors in Digital Imaging FOV Matrix size Type of Algorithm

Contrast Resolution The ability of an imaging system to distinguish structures with similar x-ray transmission as separate entities (the term not only applies to intensifying screens, but all imaging systems including computed radiography (CR), digital radiography (DR), conventional and digital fluoroscopy, computed tomography, magnetic resonance imaging, and sonography).

Contrast Resolution Influencing Factors in Digital Imaging SNR Dynamic Range Pixel Depth Type of Algorithm

TEMPORAL RESOLUTION Temporal resolution is an indication of a X-ray system's ability to freeze motions of the exposed object. An oversimplified analogy is the “shutter” speed of a camera. When a photo is taken at a sports event, a higher shutter speed should be used to reduce the blurring effects caused by the moving athletes.