Pumping Apparatus Driver/Operator

Slides:



Advertisements
Similar presentations
Carburetion Systems Small Engines.
Advertisements

Chapter 12 Lesson Goal After completing this lesson, the student shall be able to make hydrant connections and draft from a static water source according.
Fire Apparatus Pump Theory
Chapter 12 Lesson Goal After completing this lesson, the student shall be able to make hydrant connections and draft from a static water source according.
Learning Objective 1 Describe the safety considerations taken when service testing a fire hose.
3.4.5 Student Book © 2004 Propane Education & Research CouncilPage Maintaining Bulk Plant Pumps, Strainers and Bypass Systems Knowing how to maintain.
3.1.9 Student Book © 2004 Propane Education & Research CouncilPage Replacing Valves and Fittings in ASME Tanks Replacing ASME tank valves and fittings.
Chapter 13 Lesson Goal After completing this lesson, the student shall be able to use various hose appliances and tools, prepare a test site for service.
Stanley DS11 Diamond Saw.
Morgan City Rentals Diesel Jet Pump 6 x 6 Peerless Safe Operating Practices and Procedures.
CAFS On-Line Orientation

Fire Streams Geronimo Vol. Fire Dept.. Extinguishing Properties of Water G Water extinguishes fires by G Cooling G Remove heat from the fire G Smothering.
Intermediate SFFMA Objectives: – Hrs received
Water supply and drafting. Objectives Understand and be able to demonstrate the different hydrant lays and hook ups Explain/demonstrate how to operate.
Pumping Apparatus Driver/Operator
Pumping Apparatus Driver/Operator
Student Book © 2004 Propane Education & Research CouncilPage Performing Pressure Tests on Gas Distribution Lines Gas personnel must understand.
CVFD Training – Water Supply SFFMA Training Objectives: –
Hydraulics.
Fire Streams SFFMA Training Objectives: –
Dennis Sabre Fire Appliances
WATER SUPPLY Copyright© Delmar is a division of Thomson Learning.
Pump Installation Vigyan Ashram, Pabal.
Pumper Operations n Why do we need to be concerned about being good pump operators? n When we are good pump operators the personnel working the hand lines.
Chapter 9 Water Supply.
NOTRE DAME FIRE SCHOOL 2004 FIRE PUMPS 101 CAPTAIN TROY KERCKHOVE SOUTH BEND FIRE.
Performance Testing.
1402 Hybrid Firefighter I 6 th Edition Chapter 14 Water Supply.
C L A S #4 Driver Operator Refresher Training.
Pumping Apparatus Driver/Operator
Intermediate SFFMA Objectives: – Hrs received.
5.1.2 Student Book © 2005 Propane Education & Research CouncilPage 1 NFPA 58, LP-Gas Code, sets out the minimum valve and fitting requirements for propane.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
Hydraulics For The Long Term
Learning Objective 1 Explain the ways water supply system components are used by firefighters.
Lease Automatic Custody Transfer
Water Supply.
Fire Pump Functions The main function of a fire pump is to increase the pressure of the water that flows through it. Inadequate or nonexistent municipal.
Water piping design.
Instructor Lee Lautzenheiser
FIREFIGHTER II LESSON 12. TYPES OF VALVES Ball — Ball — Controls nozzle flow and pump discharge rates Gate — Gate — Controls hydrant flow Butterfly.
1402 Hybrid Firefighter II 6th Edition Chapter 15 — Fire Hose South Carolina Fire Academy.
Pumping Apparatus Driver/Operator
Pumps and Lift Stations. Background Fluid Moving Equipment Fluids are moved through flow systems using pumps, fans, blowers, and compressors. Such devices.
Fire Service Pump Operator - 12 Performance Testing.
SIZING PNEUMATIC SYSTEMS. Introduction Pneumatic systems are sized to meet output power requirements. The air distribution system is sized to carry the.
15 Water Supply. 2 Objectives Describe the sources of water for a municipal water supply system. Explain the purpose of a water treatment facility. Describe.
3.5.9 Student Book © 2004 Propane Education & Research CouncilPage 1 Although unloading a bobtail cargo tank in metered delivery service at the bulk plant.
Student Book © 2004 Propane Education & Research CouncilPage Performing Gas Distribution System Leak Checks Requirements for vapor distribution.
Backflow Prevention for Fire Sprinkler Systems State of Illinois Plumbing Code.
3.7.7 Student Book © 2004 Propane Education & Research CouncilPage 1 Replacing DOT IM tank valves and fittings requires careful application of precautions.
Firefighter III Module B Water Supply (4-19) (4-19)
Parul Institute of Engineering & Technology Subject Code : Name Of Subject : Fluid Power Engineering Name of Unit : Pumps Topic : Reciprocating.
Achieving Maximum Flows The Water Triangle.... The FIRE Tetrahedron.
Types of Fire Apparatus Equipped with a Fire Pump Sugar Land Fire Department Driver/Operator—Pumper Academy Spring 2003.
Fire Pump Theory Sugar Land Fire Department Driver/Operator—Pumper Academy Spring 2003.
Apparatus Testing Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
Water Shuttle Operations
Boiler Safety Valve Regulations
IFSTA Chapter 16 Fire Streams
Relay Pumping Operations Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
CENTIFUGAL PUMP OPERATION
Dual Pumping Definition: An operation where a strong hydrant is used to supply two Engines by connecting the Engines intake-to-intake. The second Engine.
14 Refrigerant Recovery, Recycling, and Recharging.
Fuel Supply System Service
Boiler Safety Valve Regulations
Essentials of Fire Fighting Maintenance and Testing Responsibilities
Bella Vista Fire Department Procedures on Sprinkled Buildings
Presentation transcript:

Pumping Apparatus Driver/Operator — Lesson 16 Pumping Apparatus Driver/Operator Handbook, 2nd Edition Chapter 16 — Apparatus Testing

Pumping Apparatus Driver/Operator Learning Objectives 1. Select facts about various preservice tests. 2. List the minimum pumper service tests required by NPFA 1911. 3. Select facts about the site considerations for pumper service tests. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Learning Objectives 4. State the equation for determining the correct pump discharge pressure for pump service tests. 5. Calculate corrected net pump discharge pressure. 6. List equipment needed to perform pumper service tests. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Learning Objectives 7. List equipment recommended, but not required, to perform pumper service tests. 8. State the safety precautions to be followed when performing fire pump service testing. 9. Perform an engine speed service test. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Learning Objectives 10. Perform a vacuum service test. 11. Perform a hard intake hose service test. 12. Prepare the pumper and perform a pumper service test. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Learning Objectives 13. Perform a pressure control service test. 14. Perform discharge gauge and flowmeter operational service tests. 15. Perform a tank-to-pump flow service test. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Learning Objectives 16. Select facts about reviewing test results. 17. List causes of problems that may occur during service testing. 18. Perform foam proportioning equipment service tests. Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Manufacturer’s Tests If the requirements of NFPA® 1901 are included in the apparatus bid specifications, the manufacturer is required to perform two specific tests in addition to the pump certification tests discussed later. These two tests are the road test and the hydrostatic test. Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Road Tests Road tests must be conducted on the fire apparatus after its construction is complete. The apparatus should be fully loaded in the same manner as it would be once in service. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Road Tests Road tests should be conducted in a location and manner that will not violate any applicable traffic laws or motor vehicle codes. The test surface should be a flat, dry, paved road surface that is in good condition. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Road Tests At a minimum: The apparatus must accelerate to 35 mph (56 km/h) from a standing start within 25 seconds. This test must consist of two runs, in opposite directions, over the same surface. The apparatus must achieve a minimum top speed of 50 mph (80 km/h). This requirement may be dropped for specialized wildland apparatus not designed to operate on public roadways. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Road Tests At a minimum: The apparatus must come to a full stop from 20 mph (32 km/h) within 35 feet (10.7 m). The apparatus parking brake must conform to the specifications listed by the braking system manufacturer. Beyond minimums, road tests are specific to the department taking delivery. Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Hydrostatic Tests The hydrostatic tests determine whether the pump and pump piping can withstand pressures normally encountered during fire fighting operations. Pumps are tested hydrostatically at 250 psi (1 725 kPa) for three minutes. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Hydrostatic Tests The tank fill line, tank-to-pump line, and by-pass line valves should be closed during this test. Discharged valves should be opened and capped. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Hydrostatic Tests Intake valves should be closed and/or capped. The test pressure should be maintained on the system for a minimum of three minutes without the failure of any component of the system. Pumping Apparatus Driver/Operator

Pump Certification Tests Pump certification tests are performed to make sure that the fire pump system operates in the manner for which it was designed after the pump and components are installed on the apparatus chassis. These tests must be conducted by an independent testing organization, such as Underwriters Laboratories. (Continued) Pumping Apparatus Driver/Operator

Pump Certification Tests These tests are conducted either at the manufacturer’s plant or at the fire department after delivery. These tests assure both the fire department and the insurance companies that the apparatus will perform as expected after being placed into service. (Continued) Pumping Apparatus Driver/Operator

Pump Certification Tests The results of these tests are required to be stamped into a plate that is affixed to the pump panel of the apparatus. These tests must be required in the apparatus bid specifications, either by referencing NFPA 1901 or by specific wording. (Continued) Pumping Apparatus Driver/Operator

Pump Certification Tests NFPA 1901 requires the following pump certification tests for apparatus that are equipped with a 750 gpm (3 000 L/min) or larger fire pump: Pumping test Pumping engine overload test Pressure control system test Priming device test (Continued) Pumping Apparatus Driver/Operator

Pump Certification Tests NFPA 1901 requires the following pump certification tests for apparatus that are equipped with a 750 gpm (3 000 L/min) or larger fire pump (continued): Vacuum test Water tank-to-pump flow test Internal intake pressure relief valve test (if so equipped) (Continued) Pumping Apparatus Driver/Operator

Pump Certification Tests Apparatus equipped with a fire pump that has a rated capacity of less than 750 gpm (3 000 L/min) are required to undergo the same certification tests, with the exception of the pumping engine overload test. Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Acceptance Testing These tests are conducted to assure the purchaser that the apparatus meets bid specifications at the time of delivery. A representative of the manufacturer is present during testing. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Acceptance Testing The types of tests and test criteria vary widely with local jurisdiction preference and conditions. These tests should include another pump test, even if a certification test was performed at the factory. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Acceptance Testing If the apparatus fails to perform according to the requirements detailed in the bid specifications, it should be rejected. Pumping Apparatus Driver/Operator

Minimum Pump Service Tests Required by NFPA 1911 Engine speed check Priming device tests Vacuum test Pumping test Overload test (Continued) Pumping Apparatus Driver/Operator

Minimum Pump Service Tests Required by NFPA 1911 Pressure control test Gauge and flowmeter test Tank-to-pump flow rate test Internal intake pressure relief valve test (if so equipped) Pumping Apparatus Driver/Operator

Site Considerations for Pumper Service Tests NFPA 1911 says that pumper service tests may be conducted using either a fire hydrant or static body of water as a supply source. Most jurisdictions prefer to draft from a static source during testing because this is a true test of the pump’s capability. (Continued) Pumping Apparatus Driver/Operator

Site Considerations for Pumper Service Tests When using a static water supply source, the water must be at least 4 feet (1.2 m) deep. The strainer must be submerged at least 2 feet (0.6 m) below the surface of the water. The surface of the water may be no more than 10 feet (3 m) below the centerline of the pump intake, and 20 feet (6 m) of hard intake hose should be used for drafting during testing. (Continued) Pumping Apparatus Driver/Operator

Site Considerations for Pumper Service Tests (Continued) Pumping Apparatus Driver/Operator

Site Considerations for Pumper Service Tests The atmospheric air temperature during testing should be between 0ºF and 100ºF (-18ºC and 38ºC). The water being used for testing should be between 35ºF and 90ºF (2ºC and 32ºC) because hotter water has less surface tension and could affect test results. (Continued) Pumping Apparatus Driver/Operator

Site Considerations for Pumper Service Tests The barometric pressure should be at least 29 in.Hg (98.2 kPa), corrected to sea level. (Continued) Pumping Apparatus Driver/Operator

Site Considerations for Pumper Service Tests Table 16.1 on page 487 shows the minimum hard intake hose arrangements that are necessary to perform tests on pumps of varying capabilities. These figures are good for tests that are performed at altitudes of up to 2,000 feet (610 m) above sea level. (Continued) Pumping Apparatus Driver/Operator

Site Considerations for Pumper Service Tests Beyond that figure, it may be necessary to increase intake hose diameter or the number of intake hoses used to pump the rated capacity. Altitude affects pump performance: lifting ability drops about 1 foot (0.3 m) per 1,000 feet (300 m) increase in altitude; gasoline engines have 3.5 percent less efficiency per 1,000 feet (300 m) increase in altitude. (Continued) Pumping Apparatus Driver/Operator

Site Considerations for Pumper Service Tests It is also necessary to lay out a sufficient number of discharge hoses and nozzles to pump the rated capacity of the fire pump; 2½-inch (65 mm) hose is the minimum size hose that may be used for this application. Larger hoses may be used if available. (Continued) Pumping Apparatus Driver/Operator

Site Considerations for Pumper Service Tests Scribe a mark where the hose and couplings meet. While the pump testing is proceeding, regularly check the couplings to make sure that the hose is not starting to pull loose of the coupling. (Continued) Pumping Apparatus Driver/Operator

Site Considerations for Pumper Service Tests If the scribe mark moves more than 3/8-inch (9.5 mm) away from the coupling, stop the test and replace the hose. (Continued) Pumping Apparatus Driver/Operator

Site Considerations for Pumper Service Tests Tables 16.2 a and b on page 488 show the minimum hose and nozzle arrangements needed to discharge sufficient water for various size pumps being tested. Pumping Apparatus Driver/Operator

Determining Correct Pump Discharge Pressure for Pump Service Tests Customary Pressure correction = Lift (ft.) + intake hose friction loss 2.3 (Continued) Pumping Apparatus Driver/Operator

Determining Correct Pump Discharge Pressure for Pump Service Tests Metric Pressure correction = Lift (m) + intake hose friction loss 0.1 Pumping Apparatus Driver/Operator

Equipment Needed to Perform Pumper Service Tests A gauge to check the pump intake pressure This gauge should have a range of 30 in.Hg (100 kPa) to zero for a vacuum gauge, or 30 in.Hg vacuum to 150 psi (1 050 kPa) for compound gauges. A gauge to check the pump discharge This gauge should be capable of a range from at least 0 to 400 psi (0 kPa to 2 800 kPa). (Continued) Pumping Apparatus Driver/Operator

Equipment Needed to Perform Pumper Service Tests Pitot tube with knife edge and air chamber rated at least from 0 psi (kPa) to 160 psi (1 110 kPa). This is not needed if a flowmeter is used. Straight stream nozzles of correct sizes to match the volumes pumped for the different tests. If a flowmeter is used, fog nozzles may be used provided they are rated for the necessary flows. (Continued) Pumping Apparatus Driver/Operator

Equipment Needed to Perform Pumper Service Tests Rope, chain, or test stand for securing test nozzle(s) Revolution counter or hand tachometer Fire department or insurance agency forms Pumping Apparatus Driver/Operator

Equipment Recommended to Perform Pumper Service Tests Two 6-foot (2 m) lengths of ¼-inch (7 mm), 300 psi (2 100 kPa) hose with screw fittings These are used to connect the test gauges to the test gauge fittings at the pump operator’s panel. Clamp to hold pitot tube to test nozzle (Continued) Pumping Apparatus Driver/Operator

Equipment Recommended to Perform Pumper Service Tests Test stand for gauges Thermometer Stopwatch or watch with sweep second hand Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Safety Precautions to be Followed When Performing Fire Pump Service Testing All personnel should wear protective headgear and hearing protection (if exposed to noise in excess of 90 dB). Prevent water hammer: Open and close all valves and nozzles slowly. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Safety Precautions to be Followed When Performing Fire Pump Service Testing Do not stand over or straddle hose. Manipulate the engine throttle slowly. Prevent sudden pressure changes, which can damage equipment and injure personnel. Tie down test nozzles and devices securely. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Safety Precautions to be Followed When Performing Fire Pump Service Testing Cover all open manholes at the test pit. Be aware of the location of all personnel in the test area in relation to hoselines. Pumping Apparatus Driver/Operator

Reviewing Test Results At no time during the tests should the pumping system or pumping engine show signs of overheating, power loss, or any other mechanical problems. All fluid levels should again be checked and any losses noted. (Continued) Pumping Apparatus Driver/Operator

Reviewing Test Results All calculations and figures determined during the tests should be recorded so that they may be filed according to departmental record-keeping procedures. (Continued) Pumping Apparatus Driver/Operator

Reviewing Test Results If the fire pump tests to less than 90 percent of its capabilities when it was new and underwent certification testing, two options are available: Take the pump out of service and restore it to its designed capabilities (preferred option). Give the pump a lower rating based on the test results of its actual performance. Pumping Apparatus Driver/Operator

Causes of Problems that May Occur During Service Testing Transmission in wrong gear High gear lockup not functioning (automatic transmission) Clutch slipping Engine overheating (Continued) Pumping Apparatus Driver/Operator

Causes of Problems that May Occur During Service Testing Muffler clogged Tachometer inaccurate Engine governor malfunctioning Intake hose too small (Continued) Pumping Apparatus Driver/Operator

Causes of Problems that May Occur During Service Testing Intake strainer submerged incorrectly Intake screens clogged Wrong strainer is being used for that type of hose Lift is higher than 10 feet (3 m) (Continued) Pumping Apparatus Driver/Operator

Causes of Problems that May Occur During Service Testing Intake hose clogged or inner lining collapsed Excessive air leaks at intake side of pump Pump impellers are clogged Pump or intake hose not fully primed (Continued) Pumping Apparatus Driver/Operator

Causes of Problems that May Occur During Service Testing Relief valve or pressure governor malfunctioning Transfer valve in wrong position Inaccurate gauges (Continued) Pumping Apparatus Driver/Operator

Causes of Problems that May Occur During Service Testing Pitot tube partially clogged Nozzle too large Seized turbocharger Excessive wear on impeller clearance rings Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Summary Preservice tests are conducted prior to the apparatus being delivered, and usually do not involve fire department personnel. Once delivered, fire department pumpers are tested again before being placed into service, and driver/operators may or may not be involved in this testing. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Summary Once in service, pumping apparatus are tested at least annually to ensure continued acceptable performance. Fire department driver/operators are often directly involved in these annual service tests. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Summary Fire department driver/operators must be familiar with the preservice testing procedures, and be capable of conducting or assisting with annual service tests. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Summary To perform these duties adequately, driver/operators must be familiar with correcting net pump discharge pressure for tests, the sequence of tests, equipment needed, safety precautions, and possible causes of trouble during the tests. Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Discussion Questions 1. What are the criteria to be met for a road test? 2. Name the minimum pumper service tests required by NFPA 1911. 3. State the equation for determining the correct pump discharge pressure for pump service tests. 4. Name equipment needed to perform pumper service tests. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Discussion Questions 5. Name equipment recommended, but not required, to perform pumper service tests. 6. State the safety precautions to be followed when performing fire pump service testing. 7. Name causes of problems that may occur during service testing. Pumping Apparatus Driver/Operator