The UC Simulation of Picosecond Detectors Pico-Sec Timing Hardware Workshop November 18, 2005 Timothy Credo.

Slides:



Advertisements
Similar presentations
1 Continuous Scintillator Slab with Microchannel Plate PMT for PET Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat 2, Fukun Tang 2,
Advertisements

INSTITUT MAX VON LAUE - PAUL LANGEVIN Fast Real-time SANS Detectors Charge Division in Individual, 1-D Position- sensitive Gas Detectors Patrick Van Esch.
Fast shower maximum detector based on MCP-PMT Anatoly Ronzhin, Fermilab, AEM, March 10, 2014 Team: Sergey Los, Erik Ramberg, Fermilab Artur Apresyan, Si.
PID Univ. 31.Aug.2002 Contents 1.Introduction 2.PMT structure & Set up 3.Basic performance 4.Experiment results –Gain –Time resolution.
The Factors that Limit Time Resolution in Photodetectors, Workshop, University of Chicago, April 2011 What is known experimentally about timing determinants.
Photodetector Timing Resolution Burle Micro-Channel Plate Photo Multiplier Tubes (MCP-PMTs) H. Wells Wulsin SLAC Group B Winter 2005.
Time-of-Flight at CDF Matthew Jones August 19, 2004.
1 A Design of PET detector using Microchannel Plate PMT with Transmission Line Readout Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat.
PID Nagoya univ1 The possibility of improving TOP counter Nagoya university Yuji Enari.
Detectors. Measuring Ions  A beam of charged particles will ionize gas. Particle energy E Chamber area A  An applied field will cause ions and electrons.
POSTER TEMPLATES BY: Development of Front-End Electronics for Picosecond Resolution TOF Detectors Fukun Tang, Enrico Fermi.
Timing Properties of T0 Detectors At PHOBOS Saba Zuberi, Erik Johnson, Nazim Khan, Frank Wolfs, Wojtek Skulski University of Rochester.
Development of Picosecond-Resolution Large-Area Time-of-Flight Systems C. Ertley 2, J. Anderson 1, K.Byrum 1, G.Drake 1, H.Frisch 2, J. Genat 2, H. Sanders.
UIC – Physics Department Fast Timer Project Bob Dysert, Alan Bross - Fermilab November 18, 2005.
Scintillation Detectors
10 Picosecond Timing Workshop 28 April PLANACON MCP-PMT for use in Ultra-High Speed Applications.
Page The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
Peter Križan, Ljubljana March 17, 2006 Super B Workshop, Frascati Peter Križan University of Ljubljana and J. Stefan Institute Aerogel RICH and TOP: summary.
May 31, 2008 SuperB PID sessionMarko Starič, Ljubljana Marko Starič J. Stefan Institute, Ljubljana Report on hardware tests and MC studies in Ljubljana.
1 Fast Timing via Cerenkov Radiation‏ Earle Wilson, Advisor: Hans Wenzel Fermilab CMS/ATLAS Fast Timing Simulation Meeting July 17,
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Photodetection EDIT EDIT 2011 N. Dinu, T. Gys, C. Joram, S. Korpar, Y. Musienko, V. Puill, D. Renker 1 Micro Channel plate PMT (MCP-PMT) Similar to ordinary.
“End station A setup” data analysis Josef Uher. Outline Introduction to setup and analysis Quartz bar start counter MA and MCP PMT in the prototype.
Detectors and Cross Talk Presented below are cross talk measurements carried out on 2 Burle and 1 Hamamatsu MCP PMTs and 1 Hamamatsu MultiAnode PMT (MAPMT).
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
Two-stage amplifier status test buffer – to be replaced with IRSX i signal recent / final (hopefully) design uses load resistor and voltage gain stage.
ON BEHALF OF THE LHCb RICH/TORCH COLLABORATION
TOP counter overview and issues K. Inami (Nagoya university) 2008/7/3-4 2 nd open meeting for proto-collaboration - Overview - Design - Performance - Prototype.
work for PID in Novosibirsk E.A.Kravchenko Budker INP, Novosibirsk.
Development of TOP counter for Super B factory K. Inami (Nagoya university) 2007/10/ th International Workshop on Ring Imaging Cherenkov Counters.
PID for super Belle (design consideration) K. Inami (Nagoya-u) - Barrel (TOP counter) - Possible configuration - Geometry - Endcap (Aerogel RICH) - Photo.
Optimization of Detectors for Time of Flight PET Marek Moszyński, Tomasz Szczęśniak, Soltan Institute for Nuclear Studies, Otwock-Świerk, Poland.
Timing properties of MCP-PMT K.Inami (Nagoya university, Japan) - Time resolution - Lifetime - Rate dependence Photon Detector Workshop at Kobe,
July 4, 2008 SuperBelle Meeting, KEKPeter Križan, Ljubljana Peter Križan University of Ljubljana and J. Stefan Institute Burle MCP PMTs as photon detector.
1 Geant4 Simulation :MCP PET 4’’(102mm) Scintillator ( LSO) 4’’(102mm) 10mm Glass( Borosilicate) PhotocathodeI(Carbon) Space(Vacuum) MCP(Alumina) Space(Vacumm)
BURLE update Peter Križan Friday meeting, Mar 24, 2006.
Anatoly Ronzhin, 23 June, 2009 Anatoly Ronzhin, June 23, 2009 The main results of the TOF study at MT beams, May-June 2009 The team: Anatoly Ronzhin, Hans.
Test beam preliminary results D. Di Filippo, P. Massarotti, T. Spadaro.
Update on Physical Parameters that influence Timing Jean-Francois Genat LPNHE Paris LAPPD Electronics & Integration Review July 9th 2012, Chicago.
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
MCP-PET: Geant4 Simulation Geometry Implementations 1. Similar to the last report (polished surface). Scintillator : LSO, LaBr3 # of layers : 5 -> 4 Area.
Update on THGEM project for RICH application Elena Rocco University of Eastern Piedmont & INFN Torino On behalf of an Alessandria-CERN-Freiburg-Liberec-
TORCH IOP meeting Manchester March 31, 2015 TORCH Maarten van Dijk On behalf of the TORCH collaboration (CERN, University of Oxford,
Photon Transport Monte Carlo September 27, 2004 Matthew Jones/Riei IshizikiPurdue University Overview Physical processes PMT and electronics response Some.
Aerogel RICH & TOP counter for super KEKB Y.Mazuka Nagoya University June 14-16, 2006 The 3 rd SuperB workshop at SLAC.
TORCH – a Cherenkov based Time-of- Flight Detector Euan N. Cowie on behalf of the TORCH collaboration E N Cowie - TORCH - TIPP June 2014.
The VSiPMT: A new Generation of Photons Detectors G. Barbarino 1,2, F. C. T. Barbato 1,2, R. de Asmundis 2, G. De Rosa 1,2, F. Di Capua 1, P. Migliozzi.
SP- 41 magnet ZDC RPC (TOF) DC ST Target T0 detector MPD / NICA and / Nuclotron Experiments Picosecond Cherenkov detectors for heavy ion experiments.
The photomultiplier tubes selection for KM2A electromagnetic particle detectors (EDs) hou chao IHEP The 2nd workshop of air shower detection at high altitudes.
KM2A PMT testing platform FENG Cunfeng, LI Chaoju, SUN Yansheng Shandong University THE 2 nd WORKSHOP OF AIR SHOWER DETECTION AT HIGH ALTITUDES IHEP, Beijing,
Reed Research Reactor reactor.reed.edu/pictures.html reactor.reed.edu/pictures.html 1 Moriah Tobin Modeling Quartz Cherenkov Detectors.
1 The Scintillation Tile Hodoscope (SciTil) ● Motivation ● Event timing/ event building/ software trigger ● Conversion detection ● Charged particle TOF.
Efficiency, Dark noise, and Baseline fluctuations with Burle-Photonis MCP-PMT's Jean-Francois Genat and Edward May Dec 2009 –Jan 2010.
Preliminary Analysis of the New Focusing DIRC Prototype Beam Data
Results achieved so far to improve the RPC rate capability
Scintillation Detectors
Ioannis Manthos Laboratory of Nuclear & Particle Physics
Ioannis Manthos Laboratory of Nuclear & Particle Physics
The Development of Large-Area Psec-Resolution TOF Systems
Measured baseline fluctuations and dark counts with Burle-Photonis MCP-PMT's Jean-Francois Genat and Edward May Dec 2009 –Jan 2010.
Deng Ziyan Jan 10-12, 2006 BESIII Collaboration Meeting
Scintillation Counter
Enrico Fermi Institute and Physics Dept
Impedance & Bandwidth Measurements of '2-strip anode test plate'
Latest Results from T979: PSec Time-of-flight
The Development of Large-Area Psec-Resolution TOF Systems
Photomultiplier (PMT) Tubes
Status Report on MCP PET Simulation
Performance test of a RICH with time-of-flight information
Presentation transcript:

The UC Simulation of Picosecond Detectors Pico-Sec Timing Hardware Workshop November 18, 2005 Timothy Credo

TOF Detection Current method: bars of scintillator several meters long Signal amplified in PMT at each end Relevant length scale is 1 in, which governs time resolution (100 ps) 1 picosecond resolution requires scale on the order of 300 microns

A Picosecond TOF Detector Light produced in the window of MCP-PMT shines on a photocathode Signal amplified in MCP, and summed in the anode Electronics measure pulse from four collection points

Summing Multianode Multilayer circuit board collects MCP signal 16x micron pads each routed to electronics by equal-time impedance- matched traces 4 central collection points deliver signal to electronics Mismatched impedances cause signal reflections

Simulations (Window, MCP) Cherenkov emission, transmission, chromatic dispersion, and quantum efficiency simulated in ROOT (started by R. Schroll) Simulations use MCP time spread and gain (1e6) for single photons to estimate the signal arriving on the anode These data were input into an HSPICE simulation of the summing anode

Window Thickness and Material Simulations evaluated the time resolution of the window and MCP for different window materials and thicknesses MgF 2 is transparent further into the ultraviolet and offers better performance Larger windows generate more photons, providing a better average over TTS Window Width (mm) RMS Jitter (picoseconds) Number of Photoelectrons SilicaMgF 2 SilicaMgF

Time Resolution (Window, MCP) The time resolution of the window and MCP depend on the number of photons detected and on the TTS of the MCP With the Burle Planacon MCP, simulations indicate a 6 picosecond resolution A smaller TTS (already achieved in smaller area MCPs) would make 1 ps resolution possible Average timing of signals arriving at the anode, for different MCPs

Simulations (Anode) The performance of the multianode was simulated in HSPICE using a spice model generated from the board design using HyperLynx With a 50 Ω termination, ringing decayed with a time constant of τ = 5.5 ns With 60 ps TTS, pulse had average rise time of 80 ps, and average height.25 V With 10 ps TTS, average rise time was 25 ps, and average height 1.2 V Voltage vs. time plots of anode simulations, with 60 ps TTS (top) and 10 ps TTS (bottom)

Ten Simulated Pulses (60 picosecond TTS)

Ten Simulated Pulses (10 picosecond TTS)

Time Resolution (Anode) With a large TTS (σ = 60 ps), the pulse shape is not consistent With this anode a resolution of around 10 to 20 picoseconds could be achieved for a large TTS With a faster MCP, the pulse shape is more stable Picosecond resolution may be possible, but not without a fast large area MCP (TTS comparable to smaller area MCPs)

Future Plans Custom summing board mates with standard 32x32 Burle anode Glue boards to Burle PMT with Planacon MCP using conductive epoxy (Greg Sellberg, Fermilab) Solder component board with fast comparators Use commercial TDC(?) and test several tubes in a beam at Fermilab or Argonne

Conclusion and Questions A picosecond TOF detector could be developed, but would rely on a fast large area MCP and fast electronics Is the MCP response to a single photoelectron a good approx. to its behavior in the case of many photoelectrons? Will the particle create a pulse as it passes through the anode and the electronics, and what effect will this have?