RSSCT Adsorptive Media Compare RSSCT = Rapid Small Scale Column Testing  30-60 days test duration  Up to 5 medias / columns  Equipment available.

Slides:



Advertisements
Similar presentations
Amherst , MA, Drinking Water System Atkins Water Treatment Plant
Advertisements

Chemical Analysis of Water
Private Homeowner Drinking Water Issues Presenter Mr. Brian Oram, Professional Geologist Wilkes University GeoEnvironmental Sciences and Engineering Department.
Arsenic/Iron Co-Precipitation and High Rate Filtration in the City of Portage Christopher Barnes, P.E., City of Portage Kendra Gwin, P.E., City of Portage.
A How To on choosing the correct filter for your needs.
MANGANESE GREENSAND To reduce high levels of Iron & Manganese with associated staining and the smell of Hydrogen Sulphide.
SISTEM PENGOLAHAN AIR, UDARA & LIMBAH PADAT
American Water Raw Water Quality Not Textbook? Just Pilot! Iron Removal with High pH Raw Water March 27, 2008 Sandy Kutzing, P.E., CDM Eric Hahn, P.E.,
Sandia is a multi-program laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy’s National Nuclear.
CO ‑ STAR: Colorado Strategy for Arsenic Reduction A Five Phase Compliance Assistance Program 1. Evaluate 2. Sample 3.Engineer4. Finance 5. Implement.
IX1 Arsenic Removal by Ion Exchange Joe Chwirka - Camp Dresser & McKee Bruce Thomson - University of New Mexico
Basic Ground Water Treatment
ARSENIC REMOVAL Case History Milos Markovic. Arsenic removal m3/day Plant in Subotica-SERBIA.
Sedimentation Sludge Zone Inlet Zone Outlet Zone V o = Q/A s The overflow rate H.
Surface Water Treatment Plant. Fig 4-8: Flow Diagram of conventional surface water treatment plant (“filtration plant”)
Sandia is a multi-program laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy’s National Nuclear.
Improving Water Quality Purification of Drinking Water General process: Collected from reservoir or ground water.
SHANNON WILLAERT IDT 510 ASSIGNMENT #4 Water to Drink NEXT 
Waupun Utilities Water Treatment Facility. Treatment Processes Source Water Pretreatment System Reverse Osmosis System Post Treatment System Distribution.
OZONE DRINKING WATER SYSTEM. CONTENTS Properties of Ozone Production of Ozone Water Treatment Plant – 25 m 3 /hr Ozone Generation System.
Iron and Manganese Removal
PH Test. 1. Label the three beakers with their respective names (do not include the buffer; this can be tested in the tube). 2. Fill the beakers with.
Choosing a Drinking Water Purification System. Drinking Water Quality Considerations Purification: removal of bad stuff PH: acidic or alkaline Minerals:
Monitoring Well Sampling. SAP (Sampling Analysis Plan) SAP (Sampling Analysis Plan) Frequency Frequency Purging Purging Pumps and Bailers Pumps and Bailers.
THE BASICS of SFR Spot Free Rinse Systems - working to keep your reputation spotless  Spot Free Rinse water must have less than 40 ppm of TDS. Our preferred.
Control of Nitrification at Willmar, MN. John T. O’Connor Bart Murphy Tom O’Connor.
Chemical Filtration Tammy Spear Kevin Landry. Types of chemical filtration There are different methods to “chemically” treat or filter the water. Some.
Treatment Options Part 1 Tom Sorg Darren Lytle Water Supply and Water Resources Division Office of Research and Development U.S. Environmental Protection.
USEPA Regulations By Douglas Rittmann, Ph.D., P.E. Water/Wastewater Consultant Presented to Entrepreneurs Association of Bari.
Abstract/Background Worldwide, corrosion of drinking water pipes and build-up of scales on the interior pipe wall impacts both the quality and quantity.
Buckhorn Disinfection Byproducts / Backwash Disposal Project Board of Directors Meeting June 14, 2012.
Water Treatment & Distribution System Overview.
Depending on the Size of the S&R Program, Additional Facilities May Be Required Groundwater Production Wells Imported Water Treatment Plant Capacity Wellhead.
Fields Of Activity Industrial water treatment Waste water treatment – recycling and upgrading Fine Cyclonic separations for cosmetics and oil industries.
Sourcewater coag/settling filtration storage elevated tank consumer Optimizing the chemistry in a water treatment plant.
The Drinking Water Treatment Process
Radium Removal and Disposal in Wisconsin
Recirculating Systems
Sewage Treatment. In the U.S. Sewage treatment is a common practice In the 1970’s many cities were still dumping raw sewage into waterways In 1972, the.
Arsenic Treatment Technologies Christopher A. Impellitteri USEPA/ORD/WSWRD/WQMB Water Technologies for Rural Texas Tuesday, December 2, 2003.
U. S. Environmental Protection Agency
Water Pollution Part 2.
Intro to Iron and Manganese Control for Small Groundwater Systems Reid Campbell, PE, AECOM November 17, 2015 NC AWWA-WEA.
Water To Drink. Water Quality The degree of purity of water, determined by measuring the substances physical, chemical and biological in water, besides.
Radionuclide Regulations, Treatment and Affordability Anthony E. Bennett, R.S. Texas Commission on Environmental Quality Water Supply Division.
How to remove impurities from water?. How to remove impurities from water We may remove solid particles by: 1 Sedimentation 2 Filtration Filter column.
Bear Trap Dunes Water Treatment Facility Report conducted by.
The Water Cycle. What are some things that you think are in your water?
ENVIRONMENTAL SCIENCE 5.4 The Waterworks. At the Waterworks When reservoirs or rivers are the source of drinking water, the water must be treated to remove.
Pollution & Clean-up. Think Tank What do you think is happening in this picture? Take 2 minutes to write down your answer on the top or back of your notes.
HOUSEHOLD WATER TREATMENT. Water Quality Problems Recommendations New source Pollution control Maintenance + inspection Treatment Explore all of them.
Water Treatment Fundamentals. Agenda MEP Fundamentals (1 st badge): Ion exchange chemistry Softener designs and options Ion exchange capacity calculations.
Sludge water recycling unit UFOX 10
Well Water Testing Workshop COAL CREEK CANYON
Amherst , MA, Drinking Water System Atkins Water Treatment Plant
Hub 4 Water Media Filters
Hub 4 Water Design, build, installation and servicing of all systems
How to Winterize an Above Ground Pool
Hub 4 Water Hub 4 Water Softener
CHAP. 2.2 – WATER TO DRINK.
Boiler System Make-up Water Primary Secondary Pretreatment
Hub 4 Water Carbon Filters
Transient, Non-Community Drinking Water Systems Training Class
Private Homeowner Drinking Water Issues
Filtration Technologies Comparison for Tertiary Treatment
Pilot testing services and a case study to reduce organics Devendra Borikar, Laura Zettler, Jeff Avedesian, Lindsay Ariss, Luc Léonard, Denis Dolbec,
Well Water Testing Workshop COAL CREEK CANYON
Sedimentation Sludge Zone Inlet Zone Outlet Zone V o = Q/A s The overflow rate H.
Treatment – Chemical Filters
Presentation transcript:

RSSCT Adsorptive Media Compare RSSCT = Rapid Small Scale Column Testing  days test duration  Up to 5 medias / columns  Equipment available free from DES and UNH TAC  PWS collects and pays sample analyses  Daily inspection required

Anion Exchange  Simplest onsite regeneration  Must manage alkalinity / corrosion  Dumping happens!  No As III removal

Iron-Arsenic Oxidation Filtration (aka greensand)  20:1 Iron to As ratio  pH ≤7.5  Chlorine or Permanganate feed  High Backwash Rate Pyrolusite medias  Backwash filter or common septic tank

 A to Z list –“A” = Arsenic drinking water page –“R” = Radon in Air page –“R” = Rads drinking water page –“S” = Small PWS Help Center –“U” = Uranium / rads page  Quick Links “Publications/Factsheets” 