Air Force Portable Device for Retinal Imaging Abdelhamid Jnane Mentors: Zhongping Chen Qiang Qiang Wang University of California, Irvine Beckman Laser.

Slides:



Advertisements
Similar presentations
Noise in Radiographic Imaging
Advertisements

Detection of weak optical signals D.R. Selviah, R.C. Coutinho, H.A. French and H.D. Griffiths Department of Electronic and Electrical Engineering, University.
An Alternative Method of Extending Imaging Window of Fourier Domain – Optical Coherence Tomography by Using a Complex Conjugate Removal Technique Amine.
QR Code Recognition Based On Image Processing
Measurements and simulations for optimization of a microwave frequency-modulated continuous-wave radar Tamara Gaynes – Mentor: Fernando Rodriguez-Morales,
POSTER TEMPLATE BY: Image Processing in Spectral Domain Optical Coherence Tomography (SD-OCT) Vasilios Morikis 1,2, Dan DeLahunta.
Frequency Domain Optical Coherence Tomography (FDOCT) Joon S Kim IMSURE Summer Research Fellow At Beckman Laser Institute University of California at Irvine.
Noise. Noise is like a weed. Just as a weed is a plant where you do not wish it to be, noise is a signal where you do not wish it to be. The noise signal.
Development and Refinement of Long Period Fiber Grating (LPFG) Manufacture and Characterization Techniques Kevin Edmonds Patrick Chan Dr. H.P. Lee.
Optical Coherence Tomography Zhongping Chen, Ph.D. Optical imaging in turbid media Coherence and interferometry Optical coherence.
1 Swept Source Frequency Domain Optical Coherence Tomography Swept Source Frequency Domain Optical Coherence Tomography Anurag Gupta University of Rochester,
PERFORMANCE OF THE DELPHI REFRACTOMETER IN MONITORING THE RICH RADIATORS A. Filippas 1, E. Fokitis 1, S. Maltezos 1, K. Patrinos 1, and M. Davenport 2.
III. Results and Discussion In scanning laser microscopy, the detected voltage signal  V(x,y) is given by where j b (x,y) is the local current density,
Algorithm Optimization for Swept Source Fourier Domain Optical Coherence Tomography (OCT) with Galvo Scanner and Digital Signal Processor (DSP) Kevin Seekell.
STUDY OF AMPLIFICATION ON ERBIUM DOPED FIBER AMPLIFIER Lita Rahmasari, Assoc. Prof. Dr. Yusof Munajat, Prof. Dr. Rosly Abdul Rahman Optoelectronics Laboratory,
What is OCT? Ultrahigh resolution optical coherence tomography (UHR OCT) is an upcoming new technology that allows non-invasive, optical medical diagnostic.
8.1 PRODUCTION AND CHARACTERISTICS OF X-RAYS
Optical Coherence Tomography
Fundamental of Fiber Optics. Optical Fiber Total Internal Reflection.
Evaluation of a Scanned Laser Display as an Alternative Low Vision Computer Interface Conor Kleweno, Eric Seibel, Ph.D., Kyle Kloeckner, Bob Burstein,
Abstract The index of refraction of a material can be used to determine how light bends as the rays travel through a substance. Therefore, this property.
Building a Photodetector to Observe the Polarization of Light Kevin J. McElwee Bridgewater State University, Bridgewater MA Mentor: Edward F. Deveney.
FIBER OPTIC RS-OCT PROBE Team Members: John Acevedo Kelly Thomas Chris Miller Advisors: Dr. Patil Dr. Mahadevan-Jansen.
Speckle Noise Reduction in Optical Coherence Tomography By: Marisse Foronda Rishi Matani Hardik Mehta Arthur Ortega.
D EDICATED S PECTROPHOTOMETER F OR L OCALIZED T RANSMITTANCE A ND R EFLECTANCE M EASUREMENTS Laetitia ABEL-TIBERINI, Frédéric LEMARQUIS, Michel LEQUIME.
Vasilios Aris Morikis Dan DeLahunta Dr. Hyle Park, Ph.D.
Extracting Barcodes from a Camera-Shaken Image on Camera Phones Graduate Institute of Communication Engineering National Taiwan University Chung-Hua Chu,
Image Restoration using Iterative Wiener Filter --- ECE533 Project Report Jing Liu, Yan Wu.
Presentation Overview
FEMTOSECOND LASER FABRICATION OF MICRO/NANO-STRUCTURES FOR CHEMICAL SENSING AND DETECTION Student: Yukun Han MAE Department Faculty Advisors: Dr. Hai-Lung.
WDM Fiber Vibrometry Krzysztof M. Abramski.
Experimental Results ■ Observations:  Overall detection accuracy increases as the length of observation window increases.  An observation window of 100.
Fig. 3 Wind measurements experimental setup Lidar (light detection and ranging) operates using the same concept of microwave RADAR, but it employs a lot.
Simple Multiwavelength Time-Division Multiplexed Light Source for Sensing Applications Thilo Kraetschmer and Scott Sanders Engine Research Center Department.
Optical Coherence Tomography and its Application to Tissue Engineering Garret Bonnema College of Optical Sciences Industrial Affiliates February 28, 2007.
Laser-Based Finger Tracking System Suitable for MOEMS Integration Stéphane Perrin, Alvaro Cassinelli and Masatoshi Ishikawa Ishikawa Hashimoto Laboratory.
DECREASED FLICKER SENSITIVITY WITH A SCANNED LASER DISPLAY. J.P. Kelly 1, H.L. Pryor, E.S. Viirre, T. Furness III. 1 Children's Hospital & Medical Center;
3. Optical Coherence Tomography (OCT)
Novel Semi-Transparent Optical Position Sensors for high-precision alignment monitoring applications Sandra Horvat, F.Bauer, V.Danielyan, H.Kroha Max-Planck-Institute.
Pulse Shaping with MIIPS SASS 8/22/2012 David Nicholson.
Improved Image Quality in AO-OCT through System Characterization
Daniel deLahunta Vasilios Morikis Dr. Hyle Park. Overview of OCT  High resolution, live imaging  Subsurface features  No preparation  Used in many.
Chapter 15 Preview Objectives Combining Light Waves
Dr. Yingtian Pan’s Lab Unjoo Lee. About him  He is an associate Professor
APS, 44th Annual Meeting of the Division of Plasma Physics November 11-15, 2002; Orlando, Florida Hard X-ray Diagnostics in the HSX A. E. Abdou, A. F.
Date of download: 6/2/2016 Copyright © 2016 SPIE. All rights reserved. Dye ring laser control, spectroscopic, and locking feedback system showing overlapping,
RECONSTRUCTION OF MULTI- SPECTRAL IMAGES USING MAP Gaurav.
Date of download: 6/21/2016 Copyright © 2016 SPIE. All rights reserved. The schematic of the spectral domain OCT imaging system used in this study. Image.
Optical Instruments II Instruments for Imaging the Retina.
Literature Survey of Spectroscopic OCT Tuan-Shu Ho 1.
Date of download: 6/25/2016 Copyright © 2016 SPIE. All rights reserved. (a) Schematic of the interventional multispectral photoacoustic imaging system.
Date of download: 6/26/2016 Copyright © 2016 SPIE. All rights reserved. (a) Microfocus x-ray computed tomography (μCT) setup used in this study. (b) In.
Calibration and the status of the photon calibrators Evan Goetz University of Michigan with Peter Kalmus (Columbia U.) & Rick Savage (LHO) 17 October 2006.
Medical Image Analysis
Four wave mixing in submicron waveguides
From: In Vivo Human Choroidal Vascular Pattern Visualization Using High-Speed Swept-Source Optical Coherence Tomography at 1060 nm Invest. Ophthalmol.
Invest. Ophthalmol. Vis. Sci ;45(11): doi: /iovs Figure Legend:
Optical Coherence Tomography
Vassiliy Tsytsarev University of Maryland school of Medicine
From: The Photosensitivity of Rhodopsin Bleaching and Light-Induced Increases of Fundus Reflectance in Mice Measured In Vivo With Scanning Laser Ophthalmoscopy.
Digital Processing Techniques for Transmission Electron Microscope Images of Combustion-generated Soot Bing Hu and Jiangang Lu Department of Civil and.
Contents Abstract Introduction VRD (Virtual Retinal Display) Basics
Gary Margrave and Michael Lamoureux
Volume 95, Issue 7, Pages (October 2008)
Sapun H. Parekh, Young Jong Lee, Khaled A. Aamer, Marcus T. Cicerone 
A near–quantum-limited Josephson traveling-wave parametric amplifier
OL 750 Measurement Systems
8.5 Modulation of Signals basic idea and goals
N.Kukhtarev, T.Kukhtareva, P.Land, J.H. Caulfield, and J.Wang
Volume 98, Issue 9, Pages (May 2010)
Presentation transcript:

Air Force Portable Device for Retinal Imaging Abdelhamid Jnane Mentors: Zhongping Chen Qiang Qiang Wang University of California, Irvine Beckman Laser Institute

OUTLINE Background Goals Device setup Components System parameters Device component assembly Sample OCT Images Experimental design Wiener filter implementation

Background Field-deployable screening device to detect lesions of the retina – To facilitate early diagnostic of ocular laser induced injuries caused by laser weapons and laser guided aiming devices. – To reduce the risk of catastrophic failure of vision. – To ensure that flight personnel will conduct missions with full visual acuity.

Background Replacement of the current photographic fundus imaging device – Standard procedure for evaluating ocular lesions, it provides only two-dimensional retinal imaging The newly developed optical coherence tomography technology with integrated micro electro mechanical system (MEMS) To provide a three-dimensional of retinal images’ surface

Background The proposed field deployable imaging device will find many other applications – In ophthalmology clinical practice where evaluation and diagnosis of retinal health is very important – Anyone engaging in a potentially dangerous activity requiring superb visual performance

Goal Designing a compact & portable OCT system – Features Dimensions: 8” x 8” x 4” Sensitivity of 99.3 db High speed ( 20,000 A-lines/s ) High resolution (12  m ) Coherence length of 9.8mm at 2 kHz sweep rate Testing our device in vivo animal and human subjects – Evaluating retinal injuries in hamster and rats Filtering the noise that corrupted the source signal (ripples)

Device Setup Figure 1: Schematic of the FDOCT system: collimator; Atte., neutral density attenuator; D1 and D2, photodetectors.

Components – Collimator (OFR Inc., 1060 nm) – Gold mirror (Thorlabs Inc., ½”) – 2 circulators (Agiltron Inc., 1060 nm) – 70/30 2x2 couplers (AC Photonics Inc nm) – 50/50 2x2 couplers (AC Photonics Inc nm) – X stage (Newport Inc.) – Light source (Santec Inc., 1060 nm, 28 kHz) – Aluminum case (Hammond Manufacturing, 10.03” x 9.63” x 3.84”)

System Parameters Imaging speed: 20 k A-lines/second Power delivered to sample arm: 1.2 mw Power delivered to reference arm: 0.4 mw

Device Hardware Device Hardware Compact OCT system Non-compact OCT system

Device Component Assembly

Sample OCT Image Human eye image

Sample OCT Image

Experimental Design  In vivo animal clinical trial experiment will be conducted to test the effectiveness of the new device. Imaging devices – Portable OCT system – Photographic fundus imaging system Evaluation of images by ophthalmologists – Group 1: photographic fundus images only – Group 2: photographic fundus images and OCT images Ophthalmologist evaluation compared to histology evaluation

Group A (5 Rats) 23.6 mw, 0.25 s

Wiener Filter The wiener filter is an adaptive filter. It tailors itself to be the “best possible filter” for a given dataset. Below is a simple version of the derivation for the wiener formula.

Wiener Filter Standard equation to model a signal with noise: y [n] =x [n] +n [n] (1) We want to pass this y [n] through a filter ‘h’ – To get back something that very closely matches our original signal x, ( x) Design a filter that minimizes the difference between x and x. – minimizing the least mean square error between x and x  [x − ˜x] 2 (2)

Wiener Filter Since x is h*y, we have: [ x − h * y ] (3) Expanding this expression and taking the Fourier transform of the expression to get the power spectra: – ∑(j) ( (Xj − HjYj))2 (4) – ∑(j) ((Xj − Hj (Xj + Nj))2 (5) After simplification we get the following formula for H – H (f) = (|X (f) |)2/ (|X (f) |)2 + (|N (f) |)2 (6)

Spectral Reshaping Small ripples in the light source spectrum caused by antireflection coating of the semiconductor optical amplifier Ripples & other types of dispersions in the optical fiber components modulate the fringe contrast of the spectral interference signal Spectrum of light with ripple and side lobes

Spectra and Gaussian Fit from Glass Slide Solid curve: Spectrum determined from a single image Dashed curve: Gaussian fit to each spectrum

Coherence Envelopes Determined from Glass Slide Dotted curve: Uncorrected response Solid curve: Corrected response

Design of Wiener Filter Determine the envelope of the wavelength-dependent fringe contrast – Design a spectral shaping filter from the OCT spectral signals Spectral interference signal can be rewritten as follows: – S j (k) = Se (k) *cos φ j(k) (1) contrast envelope* fringe where φ j(k) is the phase of the j-th fringe

Design of Wiener Filter The ensemble average of spectral interference in j is expressed as – (Sj(k)^2)j = Se(k)^2 cos^2φ j(k)j Simplified equation of the contrast envelope: – Se(k) =√(2/N*Σ(j)Sj(k)^2). Substituting Se(k) into the following the Wiener filter: – W(k) =(Se(k)/(Se(k)2 +nc))*Gauss(k) – nc is a constant depending on the SNR of the detection system – Gauss(k) is a Gaussian window to reshape the spectrum to a Gaussian profile.

Implementation of Wiener Filter SpecEnv[j] = A + B1*j + B2*j^2 + B3*j^3 + B4*j^4 + B5*j^5 + B6*j^6 + B7*j^7+ B8*j^8 – Where: A= ; B1= ; B2= ;B3=9.5098E 5; B4= E7; B5= E-9; B6= E-12; B7= E-15;B8= E-18 GuassionEnv[j] = 100*exp(-(j-425.0)* (j-425.0)/240.0/240.0); SpecReshape[j]=GuassionEnv[j]/(2.0*SpecEnv[ j] +constant factor);

Axial PSF without Spectral Reshaping Single image of the glass mirror

Coherence Envelopes Determined from Glass Slide

Axial PSF with Spectral Reshaping Single image of the glass mirror

Conclusion We have developed FDOCT device with 1  m swept light source which has the following specifications: Dimensions of 8” x 8” x 4”; Sensitivity of 99.3 db; High speed (20,000 A-lines/s); High resolution (12  m); Coherence length of 9.8mm at 2 kHz sweep rate.

Conclusion We have also shown that FDOCT resolution can be improved by reducing the effects of the tails or side lobes by implementing the Wiener Filter algorithm to get a gaussian shape of spectral light source. The algorithms we have used take advantage of the convolution property of Fourier transformation. Therefore, extensive computation that can slow the speed of the OCT is not necessary.

Progress 1. Prepare medication and supplies for animal study (anesthesia, eye-drops, heat pads, surgical instruments, etc.) 2. Set up portable OCT system 3. Optimize and calibrate portable OCT system 4. Order lab rats 5. Begin imaging rat, rabit and hamster retina 6. Design Wiener filter to reduce noise  Conduct the clinical trial experiment

Acknowledgements Dr. Zhongping Chen Dr. Zhongping Chen Dr. Qiang Dr. Qiang Wang University of California, Irvine University of California, Irvine Beckman Laser Institute Beckman Laser Institute IM-SURE Program IM-SURE Program Said Shokair Said Shokair NSF NSF