Describing a Real Source 1) Identify m of real source and adjust T in to line up m 2) The ratio of: 3) Measure T w ( ) to calculate  ( ) Ingle and Crouch,

Slides:



Advertisements
Similar presentations
Fluorescent Lamps.
Advertisements

Chapter 25 Instruments for Optical Spectroscopy
Spectrochemical Instrumentation Modules
An introduction to Ultraviolet/Visible Absorption Spectroscopy
The learning objectives for this course are: (1) Critically consume scientific literature and talks in the area of analytical spectroscopy. Pose meaningful.
Discharge Lamps Chapter 14 part2 1020C.
9 - Production of Light. Types pf Sources: Continuum (blackbodies, etc.) Emission line (fluorescent lamps, etc.) Emission bands (LEDs, etc.)
Dr. Mike Nofziger 2010 Sources of Light Fire– rapid oxidation of a combustible material – heat and light are emitted in the process Flame– visible light-emitting.
EMISSION AND ABSORPTION SPECTRA. Spectra A spectrum is the pattern formed when a beam of light (EM – radiation) is broken up into its component frequencies.
UV instrumentation Abu Yousuf, PhD Associate Professor Department of Chemical Engineering & Polymer Science Shahjalal University of Science & Technology.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Atomic Absorption Spectroscopy Prof Dr Hisham E Abdellatef 2011.
AA and Atomic Fluorescence Spectroscopy Chapter 9
Atomic Emission Spectroscopy
Light Source: Globar Silicon Carbide Rod (5mm diameter, 50 mm long) Heated electrically to 1300 – 1500 K Positive temperature coefficient of resistance.
EM Radiation Sources 1. Fundamentals of EM Radiation 2. Light Sources
Describing a Real Source 1) Identify m of real source and adjust T in to line up m 2) The ratio of: 3) Measure T w ( ) to calculate  ( ) Ingle and Crouch,
Luminol Chemoluminescence
Transducers Converts one type of energy into another.
Prismswww.edmundoptics.com Right AngleEquilateralPentagonalDove.
EM Radiation Sources 1. Fundamentals of EM Radiation 2. Light Sources 3. Lasers.
Infrared Spectroscopy Near Infrared: 770 to 2500 nm Near Infrared: 770 to 2500 nm 12,900 to 4000 cm -1 Mid Infrared: 2500 to 50,000 nm (2.5 to 50  m)
Geometric Optics consider only speed and direction of a ray
AES: Figures of Merit Linearity over 4 to 5Linearity over 4 to 5 concentration decades concentration decades Reasons for deviations Reasons for deviations.
Molecular Luminescence Secil Koseoglu 11/13/09. Aequorin: Guiding Star for Scientists.
Overall Ingle and Crouch, Spectrochemical Analysis.
ATOMIC ABSORPTION AND ATOMIC FLUORESCENCE SPECTROMETRY Chap 9.
Interference and Diffraction
Photomultiplier Tube m = k 8–19 dynodes (9-10 is most common).
FT-IR Instrument. Components Source Michelson Interferometer Sample Detector.
Rotational Spectra Simplest Case: Diatomic or Linear Polyatomic molecule Rigid Rotor Model: Two nuclei joined by a weightless rod J = Rotational quantum.
Optical Pumping Intense light source at h  (e.g. flash lamp) Excites to a metastable state to achieve population inversion With fast flashing, initial.
Spatial profiles of copper atom density in a Cu/Ne hollow cathode discharge P. Hartmann*, T.M. Adamowicz**, E. Stoffels and W.W. Stoffels, Department of.
Overlapping Orders Douglas A. Skoog and James J. Leary, Principles of Instrumental Analysis, Saunders College Publishing, Fort Worth, d(sin  + sin.
Transducers Converts one type of energy into another. Light  Electrical (current, voltage, etc.) What characteristics should we look for in a transducer?
Are you getting the concept? If the average irradiance from the Sun impinging normally on a surface just outside the Earth’s atmosphere is 1400 W/m 2,
Electromagnetic Spectrum The energy of the photon determines the type of transition or interaction that occurs. Table 1-1 – Ingle and Crouch, Spectrochemical.
Neodymium:YAG Laser Nd3+ in yttrium-aluminum-garnet (Y3Al5O12)
Introduction and Applications of Infrared Spectrometry
Sources of Artificial Light
Types of Light Emissions
Content Types of high intensity discharge lights Colour rendering of high intensity discharge lights Operating principles of high intensity discharge.
Atomic Absorption Spectrophotometer
3.4 Energy levels in atoms Electrons in atoms
Lighting System A lighting system consists of : 1.Light sources 2.Luminaires (or fixtures) 3.Ballasts.
1 Introduction to Spectroscopic methods Spectroscopy: Study of interaction between radiation (or other forms of energy) and matter (a branch of science).
1 Atomic Absorption Spectroscopy Lecture Performance Characteristics of Electrothermal Atomizers Electrothermal atomization is the technique of.
Atomic spectroscopy Elemental composition Atoms have a number of excited energy levels accessible by visible-UV optical methods ä Must have atoms (break.
Figure 6-4. Figure 6-8 Figure 6-11 W lamp W filament vacuum valence electrons in solid are excited by heat, relax to GS, and give off light.
Alpha College of Engg & Tech Khatraj, Gandhinagar EEE( ) 1 st SEM EE-A Group 10 1 PATEL ULKABEN RAJENDRAKUMAR ( ) 2 VINOD GIRI KHAMBHU.
II. Global Energy Balance. A. Electromagnetic Radiation: self-propagating electric and magnetic waves. Or …. Radiation transmitted through the vacuum.
Engineer Training UV System Highlights TJ8300 / TJ8500 UV System Highlights.
Guiding Questions for Objective 2: How are all light bulbs, (incandescent, fluorescent, halogen, and LED’s), alike in producing light? How are all of these.
Major lamp types. LAMP CHARACTERISTICS 1. Light production mechanisms 2. Principle lamp characteristics 3. Characteristics of three main lamp types (I)
Properties of Resistors Current of Electricity (Part 2)
LIGHT and QUANTIZED ENERGY. Much of our understanding of the electronic structure of atoms has come from studying how substances absorb or emit light.
Section 3 Section 3 Producing Light Incandescent Lights Most of the lightbulbs in your house probably produce incandescent light, which is generated by.
P.1 Book E3 Section 1.2 Lighting Lighting and environmental protection Types of lighting Check-point 2 Check-point 3 Check-point 4 Measuring brightness.
Light Sources. Luminescent materials Luminescent materials ~materials that glow when they get excited. ex. most metals, certain gases (neon) Artificial.
Chapter 5 The Periodic Table. History of the Periodic Table *By 1860 more than 60 elements were known  Stanislao Cannizzaro ( ) Found a method.
WHAT IS LIGHT? INTRODUCTION.
X-Radiation.
Lights and Its Properties: Part Two
Instrumentation of Spectroscopy
Elemental composition
Quartz-Halogen Lamp W + 2I WI2 Tungsten Atoms Evaporate off filament
Infrared absorption sepctroscopy (FT-IR)
A New Atomic Model Chapter 4 Section 1.
Chapter 27 Problems 1,11,12,15,16,22,32,33,36,49,56.
Instrumentation for UV and visible absorption
Presentation transcript:

Describing a Real Source 1) Identify m of real source and adjust T in to line up m 2) The ratio of: 3) Measure T w ( ) to calculate  ( ) Ingle and Crouch, Spectrochemical Analysis

Nernst Glower Rare earth oxides formed into a cylinder (1-2 mm diameter, ~20mm long) Pass current to give: T = 1200 – 2200 K Can operate in air (no need for glass/quartz enclosure) Ingle and Crouch, Spectrochemical Analysis Douglas A. Skoog and James J. Leary, Principles of Instrumental Analysis, Saunders College Publishing, Fort Worth, 1992.

Globar Silicon Carbide Rod (5mm diameter, 50 mm long) Heated electrically to 1300 – 1500 K Positive temperature coefficient of resistance Electrical contact must be water cooled to prevent arcing Ingle and Crouch, Spectrochemical Analysis

Tungsten Filament Ingle and Crouch, Spectrochemical Analysis Heated to 2870 K in vacuum or inert gas Useful Range: 350 – 2500nm

Tungsten / Halogen Lamp I 2 or Br 2 added Reacts with gaseous W near the quartz wall to form WI 2 W is redeposited on the filament Gives longer lifetimes Allows higher temperatures (~3500 K) and thus higher apparent brightness

Arc Lamps Ingle and Crouch, Spectrochemical Analysis Electrical discharge is sustained through a gas or metal vapor Continuous emission due to rotational/vibrational energy levels and pressure broadening

H 2 or D 2 Arc Lamps Ingle and Crouch, Spectrochemical Analysis D 2 + E e-  D 2 *  D’ + D” + h D 2 + E e-  D 2 *  D’ + D” + h Energetics: E e- = E D 2 * = E D’ + E D” + h E e- = E D 2 * = E D’ + E D” + h Useful Range: 185 – 400 nm

Hg Arc Lamp Continuum + line source High power source Often used in photoluminescence Ingle and Crouch, Spectrochemical Analysis

Douglas A. Skoog and James J. Leary, Principles of Instrumental Analysis, Saunders College Publishing, Fort Worth, Hollow Cathode Discharge Tube Apply ~300 V across electrodes Ar + or Ne + travel toward the cathode If potential is high enough cations will sputter metal off the electrode Metal emits photons at characteristic atomic lines as the metal returns to the ground state

Hollow Cathode Discharge Tube Line widths are typically 0.01 – 0.02 Å FWHM Ingle and Crouch, Spectrochemical Analysis

Light-Emitting Diodes Operate with mW of power - ~80% efficiency Long lifetimes, stable output

Are you getting the concept? List one light source with each of the following characteristics. Common IR source: Spans UV – IR: Standard household/office lighting: Lights quickly to full brightness: Common atomic absorbance source: Common photoluminescence source: