Muon Tracker Overview The PHENIX Muon Arms detect vector mesons decaying into muon pairs, allow the study of the Drell-Yan process, and provide muon detection.

Slides:



Advertisements
Similar presentations
1 Run 9 PHENIX Goals and Performance John Haggerty Brookhaven National Laboratory June 4, 2009.
Advertisements

Ultra Peripheral Collisions at RHIC Coherent Coupling Coherent Coupling to both nuclei: photon~Z 2, Pomeron~A 4/3 Small transverse momentum p t ~ 2h 
1 The Forward Silicon Vertex Detector Upgrade for the PHENIX Experiment at RHIC Douglas Fields University of New Mexico Feb. 12, 2011 Douglas Fields, WWND11,
PHENIX Vertex Tracker Atsushi Taketani for PHENIX collaboration RIKEN Nishina Center RIKEN Brookhaven Research Center 1.Over view of Vertex detector 2.Physics.
High Level Trigger of Muon Spectrometer Indranil Das Saha Institute of Nuclear Physics.
The Physics Potential of the PHENIX VTX and FVTX Detectors Eric J. Mannel WWND 13-Apr-2012.
STS Simulations Anna Kotynia 15 th CBM Collaboration Meeting April , 2010, GSI 1.
Performance of the PHENIX Muon Tracking System in Run-2 Ming X. Liu Los Alamos National Lab (for the PHENIX Collaboration) –Detector Commissioning –Detector.
APS Meeting April 5-8, 2003 at Philadelphia Chunhui Luo 1 Chunhui Luo Inclusive J/ψ Production at DØ.
Study of the Optimum Momentum Resolution of CMS Experiment Presented by: Timothy McDonald Faculty Mentor: Darin Acosta.
David L. Winter for the PHENIX Collaboration PHENIX Silicon Detector Upgrades RHIC & AGS Annual Users' Meeting Workshop 3 RHIC Future: New Physics Through.
Υ Measurements at PHENIX Shawn Whitaker RHIC/AGS Users’ Meeting June 20, /20/20111Shawn Whitaker - RHIC/AGS Users Meeting.
M. Brooks, LANL 1 Physics and Simulation Status and To-Dos Physics Section could probably use a top-down re-write. Most of the info is probably there but.
PHENIX Fig1. Phase diagram Subtracted background Subtracted background Red point : foreground Blue point : background Low-mass vector mesons (ω,ρ,φ) ~
Simulation issue Y. Akiba. Main goals stated in LOI Measurement of charm and beauty using DCA in barrel –c  e + X –D  K , K , etc –b  e + X –B 
Status of W analysis in PHENIX Central Arm Kensuke Okada (RBRC) For the PHENIX collaboration RHIC Spin Collaboration meeting November 21, /21/20091K.Okada.
Andrew Glenn 4/21/02 Commissioning and Performance of the. Muon Identifier Andrew Glenn (University of Tennessee), for the PHENIX collaboration April APS.
Setup for hypernuclear gamma-ray spectroscopy at J-PARC K.Shirotori Tohoku Univ. Japan for the Hyperball-J collaboration J-PARC E13 hypernuclear  -ray.
U N C L A S S I F I E D 7 Feb 2005 Los Alamos RHIC Program David M. Lee Heavy Ion and Medium Energy 7 February 2005.
Spiros Margetis (Kent State Univ.) for the STAR Collaboration STAR Heavy Flavor Tracker Bari, Italy 2014.
NanoPHYS’12 – December 17-19, 2012 K. Nakano, S. Miyasaka, K. Nagai and S. Obata (Department of Physics, Tokyo Institute of Technology) Drift Chambers.
STAR Spin Related Future Upgrades STAR Spin Physics Program Current Capabilities Heavy Flavor Physics W Program Transverse Program Upgrades: Plans & Technologies.
HallA/SBS – Front Tracker PARAMETERDESIGN VALUE Microstrip Silicon Detector Number of tiles/plane and size2 Number of planes2 Size of the single
QGP France sept 2010Sanjoy Pal Performances of the tracking Chambers of the ALICE MUON Spectrometer 1.
Study of Charged Hadrons Spectra with the Time Expansion Chamber of the PHENIX Experiment at the Relativistic Heavy Ion Collider Dmitri Kotchetkov University.
Malte Hildebrandt, PSIMEG - Review Meeting / 1   e  Drift Chambers Charge Division Test Chamber Testsetup for Cosmics Chamber Construction.
Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger,
The PHENIX Forward Silicon Vertex Tracker Eric J. Mannel IEEE NSS/MIC October 29, 2013.
Introduction to High Momentum Trigger in PHENIX Muon Arms RIKEN/RBRC Itaru Nakagawa 中川格 1.
M. Brooks, 29-Jan-02 P-25 Review South Arm: Hardware and Analysis Status Brief overview of muon arm Physics goals-->implied performance requirements Status.
Measurement of J/  -> e + e - and  C -> J/  +   in dAu collisions at PHENIX/RHIC A. Lebedev, ISU 1 Fall 2003 DNP Meeting Alexandre Lebedev, Iowa State.
Performance of the PHENIX Muon Identifier Introduction Calibration with cosmic rays Performance in Au+Au collisions Summary Hiroki Sato, Kyoto University.
Muon Tracker Responsibilities This Year South arm commissioning through this year’s run Analysis Software oversight and development North Arm station 2.
Jonathan BouchetBerkeley School on Collective Dynamics 1 Performance of the Silicon Strip Detector of the STAR Experiment Jonathan Bouchet Subatech STAR.
PERFORMANCE OF THE PHENIX SOUTH MUON ARM Kenneth F. Read Oak Ridge National Lab & University of Tennessee for the PHENIX Collaboration Quark Matter 2002.
2002 LHC days in Split Sandra Horvat 08 – 12 October, Ruđer Bošković Institute, Zagreb Max-Planck-Institute for Physics, Munich Potential is here...
CP violation in B decays: prospects for LHCb Werner Ruckstuhl, NIKHEF, 3 July 1998.
FIRST RESULTS OF THE SILICON STRIP DETECTOR at STAR Jörg Reinnarth, Jonathan Bouchet, Lilian Martin, Jerome Baudot and the SSD teams in Nantes and Strasbourg.
Calice Meeting Argonne Muon identification with the hadron calorimeter Nicola D’Ascenzo.
PHENIX results on J/  production in Au+Au and Cu+Cu collisions at  S NN =200 GeV Hugo Pereira Da Costa CEA Saclay, for the PHENIX collaboration Quark.
Performance and Early Results from the Muon Tracking System of Rusty Towell of Abilene Christian University for the PHENIX collaboration First Joint Meeting.
Overview of PHENIX Muon Tracker Data Analysis PHENIX Muon Tracker Muon Tracker Software Muon Tracker Database Muon Event Display Performance Muon Reconstruction.
TeV muons: from data handling to new physics phenomena Vladimir Palichik JINR, Dubna NEC’2009 Varna, September 07-14, 2009.
Search for a New State of Matter A state of matter not seen since the first few microseconds after the Big Bang is the object of study of P-25 physicists.
Muon Arm Physics Program Past, Present + Future Patrick L. McGaughey Los Alamos National Laboratory Santa Fe June 17, 2003.
Jamaica 11 Jan.8, 2009 Muon Trigger Upgrade at PHENIX RIKEN/RBRC Itaru Nakagawa RIKEN/RBRC Itaru Nakagawa.
Study of polarized sea quark distributions in polarized pp collisions at sqrt(s)=500GeV with PHENIX Oct. 10, 2008 Tsutomu Mibe (KEK) for the PHENIX collaboration.
Object-Oriented Track Reconstruction in the PHENIX Detector at RHIC Outline The PHENIX Detector Tracking in PHENIX Overview Algorithms Object-Oriented.
RPC production and performance Chong Kim Korea university RHIC spin workshop, Seoul National Univ.
David M. Lee Los Alamos National Laboratory DOE Review of the Heavy Ion Program Agenda Introduction – Joel Moss 1. David M. Lee – KB02 program.
08-Sep-00PHENIX Upgrades PHENIX has a phased strategy to q Complete the current detector q Enhance its capabilities q Extend its physics reach.
Extending the PHENIX physics reach Physics beyond the baseline accessible at RHIC II Capabilities needed to address the new physics Detector upgrades to.
Quark Matter 2002, July 18-24, Nantes, France Dimuon Production from Au-Au Collisions at Ming Xiong Liu Los Alamos National Laboratory (for the PHENIX.
The MiniBooNE Little Muon Counter Detector
S.Movchan Straw prototype beam test into the NA48 infrastructure
Evidence for Strongly Interacting Opaque Plasma
Entrance Muon Counter (EMC)
CMS muon detectors and muon system performance
Panagiotis Kokkas Univ. of Ioannina
Detection of muons at 150 GeV/c with a CMS Preshower Prototype
PHENIX RPC R&D EFFORT Beau Meredith
Tatia Engelmore, Columbia University
Hall C KPP Demonstration March 10, 2017.
Quarkonium production in ALICE
m -> eg Drift Chambers
Bi-Weekly Meeting 2004/09/08 Susumu Oda
11th Pisa meeting on advanced detectors
Presentation transcript:

Muon Tracker Overview The PHENIX Muon Arms detect vector mesons decaying into muon pairs, allow the study of the Drell-Yan process, and provide muon detection in semileptonicdecay of open charm, in the relativistic heavy ion and spin physics programs of PHENIX. Each muon arm must track and identify muons, as well as provide good rejection of pions and kaons; therefore, both a Muon Tracker (µTr) and a Muon Identifier (µID) are needed. Each arm of the Muon Tracker is comprised of three stations of tracking chambers, mounted inside the end-cap muon magnets. Stations 1 and 2 have three chamber gaps with two cathode planes read out in each gap and station 3 has two chamber gaps. Various stereo and non-stereo angles are used at each station to allow for maximal rejection of ghost intersections of cathode hits. Two different construction techniques are being used for the µTr chambers: the first and last stations are constructed as honeycomb panels with cathode strips on the inside surfaces and the central stations are constructed as stacks of wires and etched metallized foils attached to aluminum frames. The muon identification system follows the muon tracker and is comprised of 6 steel plates interspersed with Iarocci tubes. The first absorber plate also functions as the backplate of the muon tracker magnet. A cutaway view of the North muon arm is shown below. In this picture you can see the conical shaped magnet with three tracking stations, followed by the muon identification system. The PHENIX Muon Tracker Abstract The PHENIX south muon spectrometer is nearing completion. We expect to commence data collection at the beginning of the next RHIC run in May This detector system will provide general muon tracking measurements. Processes to be studied include Drell/Yan, J/Psi and other heavy vector mesons, and open heavy flavor. This includes measurements with ion beams, p-A collisions, and polarized p-p collisions. The south muon tracking system contains approximately 20,000 channels of tracking chamber cathode strips and associated front-end electronics. Using cosmic ray data we have achieved 100 micron spatial resolution in the tracking chambers with an RMS noise level of less than 2mV in the front-end electronics. Physics Capabilities These plots describe the physics capabilitites and kinematic coverage of the muon arms. Substantial modeling has been done to predict signals from single and di-muons in the muon tracking system. Out resolution goals are - resolve phi from rho+omega -resolve J/psi from psi’ -resolve Upsilon(1S) from Upsilon(2S+3S) Instrumentation These plots demonstrate the performance of the south muon tracker chambers and electronics. In constructing the muon tracking system, we were challenged to provide 100 micron resolution with less than 0.6fC of noise (less than 1.5 ADC counts after pulse amplification and digitization) in the front end electronics. PISA Geometry for the Muon Arms. Momentum resolution for the north(top) and south(bottom) muon arms. Simulated signals in the muon arms of single muons from various channels. A reconstructed PISA track in the north muon arm. Simulated di-muon signals for the muon arms (1 RHIC year at design luminosity). Acceptance for Drell-Yan events in the central (red line) and muon arms (blue and black lines). Efficiency of a station 2 chamber for different gas mixtures. Pulse sharing between adjacent cathode strips for a single cosmic ray event. The injected charge is converted to the pulse shapes above by a 3-stage preamplifier chip. RMS of pedestal values for several channels of electronics. The design spec of about 1.5 ADC counts has been met. RMS noise for all station 1 electronics. Design spec is about 1.5 ADC counts. Plot of input calibration DAC vs. digitized ADC value of the induced pulse on the cathode strip for several channels. Cosmic ray spectrum obtained from production electronics and chambers. 100 micron resolution obtained with production electronics and station 2 chamber. X axis shows CSC residuals.