Atomic Absorption Spectroscopy (AAS)

Slides:



Advertisements
Similar presentations
Atomic Absorption Spectroscopy (AAS)I
Advertisements

An Introduction to Flame Atomic Absorption Spectrometry (FAAS) Steve Badger and Charity Wessel.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Atomic spectroscopy  It’s a class of spectroscopic method in which the species examined in the spectrometer are in the form of atoms.
Spectroscopy Lecture 4 Ahmad Razali Bin Ishak Department of Environmental Health Faculty of Health Sciences UiTM Puncak Alam.
Atomic Absorption and Atomic Fluorescence Spectrometry Wang-yingte Department of Chemistry
AAS and FES (Ch 9, 7th e, WMDS)
AA and Atomic Fluorescence Spectroscopy Chapter 9
Atomic Spectroscopy Atomic Spectroscopic Methods Covered in Ch 313: Optical Atomic Spectrometry (Ch 8-10) Atomic X-ray Spectrometry (Ch 12) Atomic Mass.
Atomic Absorption Spectroscopy Yash Purohit Block 4.
Atomic Absorption Spectroscopy AAS Comparatively easy to use Low maintenance Low consumables Good for measuring one element at a time. Comparatively easy.
Analytical Chemistry –Atomic absorption Spectroscopy
Atomic Absorption Spectrometry Dr AKM Shafiqul Islam University Malaysia Perlis.
HL Chemistry - Option A: Modern Analytical Chemistry ATOMIC ABSORPTION SPECTROSCOPY.
1 Atomic Absorption Spectroscopy. 2 Atomic Transitions: Excitation and Emission.
Flame photometry.
Molecular Fluorescence Spectroscopy
427 PHC. Introduction  Spectrometric methods are a large group of analytical methods that are based on atomic and molecular spectroscopy.  Spectroscopy.
Atomic Emission Spectroscopy
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Fluorescence. Topics Sensitivity (nM-pM) –Contrast UV-vis measurements Derivatization Laser-Induced Fluorescence.
Spectroscopy Chapter 7.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Atomic-Absorption (AA) Spectroscopy 
Atomic Absorption Spectroscopy Elemental analysis Dissolved metals Source –Hallow Cathode Lamp –Cathode of specific element Sample –Acetylene-air flame,
ATOMIC ABSORPTION SPECTROSCOPY
BC ILN Atomic Absorption Spectroscopy (AAS) 1 Thompson Rivers University.
Biochemical instrumental analysis-2
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
Atomic Absorption Spectrophotometer
Atomic Absorption Spectroscopy
Atomic Absorption Spectrometry
Flame Photometry The principles.
AAS Atomic Absorption Spectrophotometry. AAS – Widely in clinical laboratories to measure elements such as aluminum, calcium, copper, lead, lithium, magnesium,
1 Atomic Absorption Spectroscopy Lecture Performance Characteristics of Electrothermal Atomizers Electrothermal atomization is the technique of.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 20
Atomic spectroscopy Elemental composition Atoms have a number of excited energy levels accessible by visible-UV optical methods ä Must have atoms (break.
Simple Double Beam Spectrometer
Simple Double Beam Spectrometer
Spectrophotometry.
Spectrofuorometer lab. 1. Fluorescence spectroscopy or (spectrofluorometry) Is a type of electromagnetic spectroscopy which analyzes fluorescence from.
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
Atomic-absorption spectroscopy
Lab 8 – Free Iron and OM in Forest Soils
ATOMIC ABSORPTION SPECTROSCOPY (AAS) Atomization: It is the conversion of molecules to their component atoms in gaseous state using a source of heat (flame).
A TOMIC - ABSORPTION SPECTROSCOPY. Atomic absorption spectroscopy (AAS) is a technique for determining the concentration of a particular metal element.
QUANTITATIVE ANALYSIS Determining amount of ions present in samples.
Atomic-absorption spectroscopy Lab3 Atomic-absorption spectroscopy.
QUANTITATIVE ANALYSIS Determining amount of ions present in samples.
Atomic Absorption Spectroscopy.  Qualitative test for metals in solution  Can also be used for coloured lights  This emission of light is called an.
A TOMIC - ABSORPTION SPECTROSCOPY Lab no. 3 Done by : Iman Al Ajeyan.
1 Chapter 8 Atomic Absorption Spectroscopy ( AAS ) Yang Yi College of Science, BUCT.
ATOMIC ABSORPTION SPECTROSCOPY SUPERVISOR: PRESENTED BY: Dr. SANGEETA OBROI SURITI SHARMA M.Sc. Chem.-3 rd Sem. M.Sc. Chem.-3 rd Sem
Simple Double Beam Spectrometer
Satish Pradhan Dnyanasadhana College Department Of Chemistry
Satish Pradhan Dnyanasadhana College, Thane Department of Chemistry T
Flame Emission Spectrometry
Atomic Absorption and Atomic Fluorescence Spectrometry
Spectroscopy Chapter 7.
Spectrophotometer Dr . S. Jayakumar.
عضو هیات علمی گروه بهداشت حرفه ای دانشگاه علوم پزشکی کاشان
Elemental composition
Dnyanasadhana College, Thane. Department of Chemistry T. Y. B. Sc
Пламена Спектроскопија
Satish Pradhan Dnyanasadhana College Department Of Chemistry
Atomic Absorption Spectroscopy. Atomic absorption spectroscopy is based on the same principle as the flame test used in qualitative analysis.
SPECTROPHOTOMETRY Applied Chemistry.
Atomic absorption spectroscopy
Spectroscopy Uses emission and absorption of light by electrons moving between ground and excited state configuration, hence electronic configuration.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Presentation transcript:

Atomic Absorption Spectroscopy (AAS) Instrumental Analysis Lab 2008 – 2009 Spring semester

Spectroscopy: The study of the interaction between radiation and matter as a function of wavelength (λ).

The technique is based on the fact that: Ground state metals absorb light at specific wavelengths. Metal ions in a solution are converted to atomic state by means of a flame. Light of the appropriate wavelength is supplied and the amount of light absorbed can be measured against a standard curve.

Basic Principle The technique of (FAAS) requires a liquid sample to be aspirated, aerosolized, and mixed with combustible gases, such as acetylene and air or acetylene and nitrous oxide. The mixture is ignited in a flame whose temperature ranges from 2100 to 2800 oC. During combustion, atoms of the element of interest in the sample are reduced to free, unexcited ground state atoms, which absorb light at characteristic wavelengths.

Basic Principle … Continue The characteristic wavelengths are element specific and accurate to 0.01-0.1nm. To provide element specific wavelengths, a light beam from a lamp whose cathode is made of the element being determined is passed through the flame. A device such as photomultiplier can detect the amount of reduction of the light intensity due to absorption by the analyte, and this can be directly related to the amount of the element in the sample.

Atomic absorption spectrometer “block diagram”

1. Radiation Source: Hollow Cathode Lamp (HCL) A cathode lamp is a stable light source, which is necessary to emit the sharp characteristic spectrum of the element to be determined. A different cathode lamp is needed for each element, although there are some lamps that can be used to determine three or four different elements if the cathode contains all of them. Each time a lamp is changed, proper alignment is needed in order to get as much light as possible through the flame, where the analyte is being atomized, and into the monochromator.

2. Chopper Function: is to fluctuate the source output It is a circular disc divided into four quarters two are mirrored and two are opened. The disc rotates at high constant speed, when the mirrored quarter in front of the lamp, it reflects the radiation. The second moment the open in front of the lamp and the radiation passes to the sample being absorbed by it and reaches the detector in pulses. The detector converts the radiation to alternating current signal and amplified it. The radiation coming from the flame itself and from atoms excited by the flame will reach the detector continuously and converted to direct current . signal which can be suppressed and eliminated.

3. Atomizer Flame Atomizer: Liquid samples introduced to atomizer through a nebulizer. Uses a slot type burner to increase path length. b) Non flame Atomizer “ Graphite Furnace) heated electrically up to 6000oC and contains a ribbon or boat in which one can inject the sample. Upon heating the furnace: the sample is ashen, then atomized by action of heat. Advantages of non flame atomizer : The sample volume is small No need for fuel -oxidant mixture. No flame noise. Solid sample can be used directly. Heat distribution is uniform and temperature is steady. Unusual high sensitivity

Flame :“Sample Introduction” Nebulizer

Types of flame: Different flames can be achieved using different mixtures of gases, depending on the desired temperature and burning velocity. Some elements can only be converted to atoms at high temperatures. Even at high temperatures, if excess oxygen is present, some metals form oxides that do not re-dissociate into atoms. To inhibit their formation, conditions of the flame may be modified to achieve a reducing, non-oxidizing flame.

Air-50% oxygen-acetylene 160 2300 Oxygen-nitrogen-acetylene 640 2815 Table 1. Characteristics of different flames Source Reynolds et al., 1970. Max. flame speed (cm/s) Max. temp. (oC) Air-Coal gas 55 1840 Air-propane 82 1925 Air-hydrogen 320 2050 Air-50% oxygen-acetylene 160 2300 Oxygen-nitrogen-acetylene 640 2815 Oxygen-acetylene 1130 3060 Oxygen-cyanogen 140 4640 Nitrous oxide-acetylene 180 2955 Nitric oxide-acetylene 90 3095 Nitrogen dioxyde-hydrogen 150 2660 Nitrous oxide-hydrogen 390 2650

4. Monochromator Is an optical device that transmits a mechanically selectable narrow band of wavelength of light or other radiation chosen from a wider range of wavelengths available at the input.

Experimental Calibration and standard curve: Is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. Prepare a series of standards across a range of concentrations near the expected concentration of analyte in the unknown. The concentrations of the standards must lie within the working range of the technique they are using. For most analyses a plot of instrument response vs. analyte concentration will show a linear relationship. The response of the unknown can be measured and, using the calibration curve, can interpolate to find the concentration of analyte.