QC And NEMA In The Nuclear Arena

Slides:



Advertisements
Similar presentations
Topic 8. Gamma Camera (II)
Advertisements

Instruments for Radiation Detection and Measurement Lab # 4.
Image Reconstruction.
QR Code Recognition Based On Image Processing
Gamma Camera Quality Control
Study of plastic scintillators for fast neutron measurements
Digital Radiography.
Chapter 17 The Grid So far we have discussed how kVp, patient size and collimation impact scatter radiation. As the part size and kVp increase, scatter.
Resident Physics Lectures
Chapter 8 Planar Scintigaraphy
Topic 11.3 Diffraction.
Computed Tomography II
Seeram Chapter 13: Single Slice Spiral - Helical CT
Image reconstruction and analysis for X-ray computed microtomography Lucia Mancini 1, Francesco Montanari 2, Diego Dreossi 3 1 Elettra - Trieste 2 A.R.P.A.
ACADs (08-006) Covered Keywords Efficiency, LLD, CPM, DPM, relative efficiency, absolute efficiency, standard deviation, confidence, count time. Description.
IMAGE QUALITY NOISE LINEARITY CROSS-FIELD UNIFORMITY IMAGE ARTIFACTS.
Fundamental Techniques and Measurements  Mass Measurements  Volume Measurements  Preparation of a solution of known concentration  UV-Visible Spectrophotometer.
Computed Tomography RAD309
On-Orbit Adjustment Calculation for the Generation-X X-ray mirror Figure D. A. Schwartz, R. J. Brissenden, M. Elvis, G. Fabbiano, D. Jerius, M. Juda, P.
Main detector types Multi Pixel Photon Counter (MPPC) and Charge Coupled Devices (CCDs) How does it work? 1. Photon hits a pixel producing electron hole.
tomos = slice, graphein = to write
Lecture 2-Building a Detector George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Digital Technology 14.2 Data capture; Digital imaging using charge-coupled devices (CCDs)
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
 QC testing of screen speed should occur on acceptance and then yearly.  Evaluate first whether similar cassettes marked with the same relative speed.
Conventional and Computed Tomography
…….CT Physics - Continued V.G.WimalasenaPrincipal School of radiography.
Seeram Chapter 11: Image Quality
Basic principles Geometry and historical development
Quality Control Rad T 110.
Dose Distribution and Scatter Analysis
CT Quality Control for CT Scanners. Quality Control in CT A good idea? Yes Required for accreditation? Sometimes Improves image quality? Sometimes Depends.
D EDICATED S PECTROPHOTOMETER F OR L OCALIZED T RANSMITTANCE A ND R EFLECTANCE M EASUREMENTS Laetitia ABEL-TIBERINI, Frédéric LEMARQUIS, Michel LEQUIME.
Innovation is in our genes. 1 Siemens Medical Solutions Molecular Imaging What are SPECT basics?
Course 12 Calibration. 1.Introduction In theoretic discussions, we have assumed: Camera is located at the origin of coordinate system of scene.
Fundamental Limits of Positron Emission Tomography
Final Presentation By Matthew Lewis 17 th March 2006 “To Determine the Accuracy that GOES True Numbers can Reproduce the Full X-ray Spectrum of the Sun”
Single Photon Emission Computed Tomography
Nuclear Medicine: Planar Imaging and the Gamma Camera Katrina Cockburn Nuclear Medicine Physicist.
IRAD 2371 Week 3.  Very few detectors will count every interaction  Each detector will have its own counting efficiency  Eff=CPM/DPM  Can use efficiency.
M. D. A NDERSON Cancer Center Nuclear Imaging (M.Cam) Richard E. Wendt III, Ph.D. and William D. Erwin, M.S. Small Animal Cancer Imaging Research Facility.
Nuclear Medicine: Tomographic Imaging – SPECT, SPECT-CT and PET-CT Katrina Cockburn Nuclear Medicine Physicist.
AESuniversity Ad hoc Reporting Version 5. for the special purpose or end presently under consideration concerned or dealing with a specific subject, purpose,
Tests of spectrometer screens Introduction Layout Procedure Results Conclusions L. Deacon, B. Biskup, S. Mazzoni, M.Wing et. al. AWAKE collaboration meeting,
CT QUALITY MANAGEMENT. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.
Part No...., Module No....Lesson No
The HESSI Imaging Process. How HESSI Images HESSI will make observations of the X-rays and gamma-rays emitted by solar flares in such a way that pictures.
The law of reflection: The law of refraction: Image formation
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
1 Nuclear Medicine SPECT and PET. 2 a good book! SR Cherry, JA Sorenson, ME Phelps Physics in Nuclear Medicine Saunders, 2012.
Nuclear Medicine Physics and Equipment 243 RAD 1 Dr. Abdo Mansour Assistant Professor of radiology
GOVERNMENT ENGINEERING COLLEGE, BHARUCH (014) Chemical Engineering department SEM-iii Sub: fluid flow operation topic: orifice meter & rotAmeter Guid by:
Chapter-4 Single-Photon emission computed tomography (SPECT)
Chapter-2 The Planar Imaging Important points in chapter 2 (chapter 13 from the book) The gamma camera (the basic principles of the gamma camera) The types.
Computed Tomography Computed Tomography is the most significant development in radiology in the past 40 years. MRI and Ultrasound are also significant.
PET Imaging Positron Emission Tomography
Computed tomography. Formation of a CT image Data acquisitionImage reconstruction Image display, manipulation Storage, communication And recording.
IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.
Diagnostic Radiology II X-ray Tubes. Anode angle Anode angle defined as the angle of the target surface with respect to the central ray in the x-ray field.
Image quality and Performance Characteristics
Image quality and Performance Characteristics
CLRS 321: Nuclear Medicine Physics and Instrumentation I
Lecture 1: Development of the Analog Gamma Camera
Single Photon Emission Tomography
Quality Control Testing of Screen Speed
QC And NEMA In The Nuclear Arena
Basic principles Geometry and historical development
Gamma Camera Ilker Ozsahin Oct
Intrinsic Uniformity QC Setup
GRIDS PRESENTER-Dr.Vishwanath patil PG resident
Presentation transcript:

QC And NEMA In The Nuclear Arena Gamma Cameras

Floods – Uniformity Testing Types of floods Co57 Impregnated plastic Old source vs. the new source Refillable flood Adding the Tc99m Mixing and spilling It will bow if its too big Point source at least 5 diameters away from the surface Key Points Setting the peak How many millions of counts? Size of the detector Complete daily Amount of activity

Corrected Vs. Uncorrected Setting your correction matrix Depends on SPECT 30 M vs. 120 M vs. the size of the head Do one for each radiopharmaceutical Correction will either subtract or add counts Take un/corrected flood and bars Correction for each PMT is no more than 10% Acquire at least once or month or when needed

Intrinsic Uniformity Determine Integral and Differential Uniformity Remove collimator place a 3mm Pb “ring” around the UFOV (example next side) Set 20% window 99mTc with source (~200 μCi) 5 UFOV away Set matrix at 64 x 64 to collect no more than 20,000 cps Acquisition - center pixels must collect 4000counts/pixe; (~16 M count flood) Complete a 9 pt smooth and calculate the following

Calculations

What are we looking at? Integral uniformity looks at maximum deviation for both CFOV and the UFOV Differential uniformity looks at the maximum change of counts over a range of any 5 pixels in every column and row Excessive changes in any of the numbers is an indication non-uniformity problems Time to call service guy!

Flood Sources Co57 Flood Source Rectangular or Circular 5 to 20 mCi Non-uniformity at <1.0% No mixing required – reduces radiation exposure Expensive since it must be repurchased based on Co57 decay Refillable Flood Phantom Rectangular or Circular Different sizes to fit a specific type of detector Inject mCi amount of Tc99m and mix in the water filled container Concerns Mixing can get messy Radiation exposure when mixing Air bubble will distort the image

Typical Bars – Four Quadrant Multiple types of phantoms are available to match the size of the detector Bars contain Pb embedded in plastic. Bars attenuate the gamma radiation being emitted from the flood source Bars vary in size within each quadrant Is usually done with the collimator on Known as an extrinsic bar Tests system resolution Imaging system should resolve between the 3rd and 4th smallest quadrant Smallest bars are 2 mm, however, it depends on the type of 4 quadrant bar purchased

Setting Up The Bar Phantom Comments How would imagine resolution be effected by LEHS vs. LEHR collimation? How does increased counts effect image resolution? How often is this procedure done on the imaging system? Why are the bars rotated every time this procedure is done?

Other Types of Bar Phantoms BHR Test Pattern Lead plate that is 3.2 mm thick is placed between 2 sheets of Plastic Orthogonal-holes are then drilled in an array pattern Emission source can be extrinsic or intrinsic (intrinsic usually done) Clearly defines system resolution Over the entire camera Linearity also identified PLES (Equally Spaced Parallel-Bar) Phantom Checks linearity and resolution Phantom is placed with flood source on top (just like the Bar and Flood) 5 mm and 3 mm bars are available Linearity is the key X and Y axis- linearity is tested Looking for a straight line Lines should not be wavy

BHR Phantom Results Example of a BHR phantom with 2.5 cm orthogonal-holes

More On Bars Do weekly and rotate each week How many counts? Size of detector Increased counts improves resolution Collimation Changes in resolution can be seen and identifies a loss of system resolution Intrinsic or extrinsic?

Systems Uniformity/Linearity/Resolution Uncorrected Flood And Bars 4000k/image Corrected Flood And Bars 4000k/image

Edge Packing Intrinsic flood uses a mask on top of the crystal to eliminate this artifact Extrinsic flood may show this artifact

Setting The Peak Centering the peak is essential Off peaking causes imaging artifact What would happen if you imaged a patient with Co57 with Tc99m on board?

Example Of Being Off-Peak Creation of lesions in the liver Could this lead to an inappropriate diagnosis?

Distance And Resolution These images show the effect of distance on image resolution Surface vs. 1 inch 2 inch vs. 3 inches What conclusion can you make when it comes to imaging a patient? Does count density also add to this issue?

Problem With A PMT What causes this artifact? How do both image sets differ? How might this effect the a patient’s diagnosis?

Problems With Liquid Filled Floods Image on the left shows a flood that was note mixed completely Image on the right shows an air bubble in the flood

Collimator Damage Image on the right indicates damage to the collimator septa Image on the left shows the effects of septa damage on a diagnostic study

More Issues Inappropriate X/Y coordinates set on the a formatter Cracked crystal

Types Of Bars A – Parallel-line equal-space (PLES) phantom: Small lead bars Test Camera’s spatial resolution. Two transmission images are Taken at right angles. Consider the Moire pattern B – Four quadrant bar phantom: Show wholes of equal size. The smallest bars can go down to 2 mm in size. C – Orthogonal-hole (OH) phantom Comes in different sizes (0.64 cm, 0.48 cm, and 0.32 cm Diameter spaced at 1 cm, 0.96 cm, and 0.64 cm respectively. Matching the lower end of system resolution is important.

Results Of Excessive Activity Activity from the source should never exceed 20k/second The image on the left shows the results of excessive activity The image on the right is the same, however, the activity has been reduced to less than 20k per second

Intrinsic Uniformity With a point source collect 64 x 64 flood where the center pixel receives a minimum of 4000 cts (16 million count flood) Filter with a 9 point smooth Integral uniformity is the maximum pixel deviation Differential uniformity max change of cts over range of any 5 pixels in all rows and in all columns

Key Points Identifies the amount of nonuniformity with all areas of the flood Variations between un/corrected should be no greater than 15% Should be done weekly to determine when the camera needs a PM “Measles” occur when water gets into the crystal Floods should be done with the collimator on to see if there are any defects in it A crystals may crack when there is change of 8 degrees F Room temperature should range between 40 and 110 degrees F

Measles Image is off-peak Loss of the hermetic seal causes water to enter and dissolve the crystal

System Sensitivity Is a parameter of camera’s ability to efficiently detect the incident gamma with the collimator on Changes in sensitivity result from Nonuniformities in the crystal Decreased energy resolution Incorrect collimation Improper setting of the PHA Recording the time it takes to collect a Co57 flood corrected for decay will identify any change in system sensitivity

System Spatial Resolution Is defined as camera’s ability to accurately determine the original location of a gamma ray on an X-Y plan with collimation

Moiré Pattern http://www.sandlotscience.com/Guided_Tours/Tour1/Tour_5.htm When a bar phantom is not lined (oriented) up septa in collimator this patter will occur Bars travel at angle to the line of wholes (septa) in the collimator This can be further seen on the next two slides

Moiré Continued Moiré seen on bar Images Bands represent the bars and the holes represent the septa Images across From each other Identify the pat- tern

Moiré Continued This shows a different moiré pattern because of the change In rotation of the bars to the collimator septa

Instrumentation and QC Consider the following procedures that involve QC and instrumentation Uniformity Matrix Floods and Bars Other types of Bars - what is there purpose? Linearity Off peak or on peak Effects of Distance on image resolution Count density PMT artifacts Crystal artifacts Collimator artifacts Flood field artifacts

QC On The Dose Calibrator Constancy Accuracy Linearity Geometry Return to the Table of Content