1 KB-PM/2005 Common Mode Chokes with VITROPERM ®.

Slides:



Advertisements
Similar presentations
Ferrites and Common-Mode Chokes. Magnetic field tend to concentrate in high- permeability ( ) materials. Some of the flux leaks out and completes the.
Advertisements

CURRENT TRANSFORMERS AND VOLTAGE TRANSFORMERS
High Frequency Saturable Reactor
Inductors and Chokes In Switch mode Supplies
Power e Lab PowerELab Limitedwww.powerelab.com 1 An Active EMI reduction IC WT6001 POWERELAB LIMITED A Power Converter Technology Provider.
SWITCH-MODE POWER SUPPLIES AND SYSTEMS Silesian University of Technology Faculty of Automatic Control, Electronics and Computer Sciences Ryszard Siurek.
1 New high permeability materials for EMI suppression February 2011 February 2011.
Magnetic Flux Conservation Stage manager: Prof. Peter von Brentano Operator: Dr. G. Pascovici.
DDC Signal Processing Applied to Beam Phase & Cavity Signals
Sweep Frequency Response Analysis (SFRA) and Transformer Diagnostics M5100 Product Series Doble Engineering Knowledge Is Power SM Apparatus Maintenance.
TIME-DOMAIN MEASUREMENT SYSTEM FOR IMPULSE NOISE CHARACTERIZATION Salvador Verdaguer Ferran Silva Electromagnetic Compatibility Group (GCEM). Technical.
Antennas Part 3 Small Loop Antenna Vector Magnetic Potential
Introduction to Wireless Communication. History of wireless communication Guglielmo Marconi invented the wireless telegraph in 1896 Communication by encoding.
Transformers and Coupled Circuits
Minntronix Technical Note
PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
PMSM Design and Loss Analysis Liping Zheng 07/23/2003.
Your Competent EMC-Partner EMC-Partner (C) 2004 NKL Elektronik San. ve Tic. Ltd. Şti.
Group Members: John Ziegler Richard Wismer III Ryan Ramdehol Wojciech Gajda.
Stuart D. BaleFIELDS iCDR – Science Requirements Solar Probe Plus FIELDS Instrument CDR Science and Instrument Overview Science Requirements Stuart D.
7.1 Chapter 7 Transmission Media Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
TRANSMISSION MEDIA’S BY KULA.
Industrial Electrical Engineering and Automation Structures of the Energy flow system Mechatronics 2007.
Breakout Magnetics: How Far Can We Take the Next Generation of Components Weyman Lundquist President and CEO West Coast Magnetics ISO9001:2008 ISO13485.
Bias Magnet for the Booster’s 2-nd Harmonic Cavity An attempt to evaluate the scope of work based of the existing RF design of the cavity 9/10/2015I. T.
10/7/2015© X2Y Attenuators, LLC1. Common Mode Filters Test comparisons, X2Y ® versus CM Chokes and PI Filters 10/7/2015© X2Y Attenuators, LLC2.
Transformer Model where r = diag [r 1 r 2 ], a diagonal matrix, and The resistances r 1 and r 2 and the flux linkages l 1 and l 2 are related to coils.
Introduction to Network (c) Nouf Aljaffan
SWITCH-MODE POWER SUPPLIES AND SYSTEMS Silesian University of Technology Faculty of Automatic Control, Electronics and Computer Sciences Ryszard Siurek.
Page 1 © 2011 Real World HF Performance of Common Mode Filter Solutions Popular EMI filters include common mode chokes (CMC), ferrite beads, and chip inductors.
1/21 Chapter 4 – Transmission Media. 2/21 Overview  guided – copper twisted pair, coaxial cable optical fiber  unguided – wireless; through air, vacuum,
Measurement Techniques and Application of Combined Parallel/Orthogonal Magnetic Bias on a Ferrite Tuned Resonator in Low Frequency Range (3-10 MHz) G.
Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc.
BEPCII Transverse Feedback System Yue Junhui Beam Instrumentation Group IHEP , Beijing.
Electronic Properties of Glassy Metals MSE 410 Rochan Mehta.
Characteristic Physical Properties. Characteristic physical properties are properties that are unique to a substance and can be used to identify it. For.
Chapter 3 Characteristic Properties Properties of Substances and Properties of Objects Objects Sharp Small Mass Volume Beautiful Carved Substances Conducts.
Stuart D. BaleFIELDS SOC CDR – Science Requirements Solar Probe Plus FIELDS SOC CDR Science and Instrument Overview Science Requirements Stuart D. Bale.
Box and Whisker Plots Example: Comparing two samples.
Status of work on the HOM coupler. 2 nd Harmonic cavity Meeting 11/II-2016 Thermal analyses with shims (Y.Terechkine). Gennady Romanov On behalf of Y.Terechkine.
Prof R T Kennedy1 EET 423 POWER ELECTRONICS -2. Prof R T Kennedy2 IDEAL TRANSFORMER MAGNETIC DEVICE ELECTRICAL ISOLATION FUNCTION: TRANSFER ENERGY SCALE.
EET 423 POWER ELECTRONICS -2
The Different Types of Inductors and Their Affecting Factors
Maintaining Impedance in Split Core Ferrites for Low-Frequency Applications Rachael Parker Vice President of Fair-Rite Products Corp.
Magnet and ferrites tests Luciano Elementi Mu2e Extinction Technical Design Review 2 November 2015.
Profiles of density fluctuations in frequency range of (20-110)kHz Core density fluctuations Parallel flow measured by CHERS Core Density Fluctuations.
RF Spectrum Analyzer Dong-Yo Jheng 2012/07/12. RF (Radio Frequency) Frequency: 3 kHz ~ 300 GHz 2.
Density. Take a look at the two boxes below. Each box has the same volume. If each ball has the same mass, which box would weigh more? Why?
Ferrite measurements of Mu2e AC dipole Summer Student Meeting August 25, 2010 Student: Evgeny Bulushev, NSU Supervisor: George Velev, TD\Magnet Systems.
CCM Power Factor Correction Inductor Design with Powder Core
Material Measurement of TT2-111R 16-Oct-20121Christine Vollinger & Fritz Caspers Measurements provided by TT.
Auto Transformer Current Flow. Principles of Auto Transformers H X H0/X0.
HF Wire Antennas, EMI Contest Stations WCARC November 2016 VE3KL
Using diode laser for atomic physics (I)
William Stallings Data and Computer Communications 7th Edition
What are transformers and how do they work?
EET 422 EMC & COMPLIANCE ENGINEERING
EET 422 EMC & COMPLIANCE ENGINEERING
Properties of sound.
Analog Operating Modes
Transmission Frequency
Transmission Media.
IF13 series: Power cord with Input EMC Filter
Comparison of Seismic and Well Data
OC3570 Operational Meteorology
Mathematics (9-1) - iGCSE
University of Houston Datacom II Lecture 1C Review 2
RF Parameters for New 2.2 km MEIC Design
MEIC beam path change with e-ring bypass lines
Impedance of the 2x50 to 100 ohm transformers.
Presentation transcript:

1 KB-PM/2005 Common Mode Chokes with VITROPERM ®

Seite VITROPERM® CM Chokes & Cores Seite 2 VITROPERM®CMC Common Mode Chokes with VITROPERM ® Cores

Seite VITROPERM® CM Chokes & Cores Seite 3 VITROPERM®CMC Common Mode Choke Designs with VITROPERM ® Cores better attenuation – smaller – less stages

Seite VITROPERM® CM Chokes & Cores Seite 4 VITROPERM ® Common Mode Chokes Properties & Benefits Material:high initial permeability µ i - low µ(f) - low Q-factor - low temperature dependency - high upper application temperature - high saturation flux density B s CMC:high low-frequency attenuation - small size - low no. of turns – low winding capacity – high high-frequency attenuation – easy to design – smooth and steady damping up to high temperatures Filter:easy to design – less stages possible - smaller volume – lower costs VITROPERM®CMC

Seite VITROPERM® CM Chokes & Cores Seite 5 Nanocrystalline VITROPERM ® Basic Advantages I VITROPERM®CMC

Seite VITROPERM® CM Chokes & Cores Seite 6 Nanocrystalline VITROPERM ® Basic Advantages II VITROPERM®CMC high µ at low and at high frequencies

Seite VITROPERM® CM Chokes & Cores Seite 7 Nanocrystalline VITROPERM ® Basic Advantages III VITROPERM®CMC high Bs, extended T - range (140 °C and higher)

Seite VITROPERM® CM Chokes & Cores Seite VP: LF:high µ, high attenuation VP: HF:small N  small C W VP: MF: broad band standards (150 kHz - 30 MHz) Noise source harmonics frequency [MHz]  VITROPERM®CMC VITROPERM ® Chokes in Comparison

Seite VITROPERM® CM Chokes & Cores Seite 9 VITROPERM ® CMC – Design Example I VITROPERM®CMC CMC 4 A

Seite VITROPERM® CM Chokes & Cores Seite 10 VITROPERM ® CMC – Design Example II VITROPERM®CMC Comparison to ferrite with Curie Temp.  130°C

Seite VITROPERM® CM Chokes & Cores Seite 11 Comparison to ferrite with Curie Temp.  150°C VITROPERM ® CMC – Design Example III VITROPERM®CMC

Seite VITROPERM® CM Chokes & Cores Seite 12 Standard CMC‘s (1 phase): Overview

Seite VITROPERM® CM Chokes & Cores Seite 13 Standard CMC‘s (3 phase): Overview

Seite VITROPERM® CM Chokes & Cores Seite 14  EMC Kit  Core sample box  Sample shortly  Application notes, technical articles  EXCEL-worksheet „VACSIM 4.0“  VITROPERM®CMC VITROPERM ® CMC’s Support