D. Aguglia & R. Rebeschini

Slides:



Advertisements
Similar presentations
RES-E Impact on Transmission Grid and Power System Reserves
Advertisements

1 Series Resonant Converter with Series-Parallel Transformers for High Input Voltage Applications C-H Chien 1,B-R Lin 2,and Y-H Wang 1 1 Institute of Microelectronics,
Wind Turbine Session 4.
Bearing Currents in Wind Turbine Generators
Fault Ride Through Techniques of DFIG-based Wind Energy Systems Presenter: Lingling Fan, Co-authors: Chanxia Zhu, Minqiang Hu (Southeast University, Nanjing.
Wind Turbine Generators
Wind farms with HVDC delivery in Load Frequency Control Lingling Fan April 22, 2010.
Power Conversion Group School of Electrical and Electronic Engineering The University of Manchester, UK DFIG Wind Turbine Control System Co-ordination.
Two-pole,3-phase,wye-connected,salient-pole synchronous machine
ACCIONA WINDPOWER WIND POWER PLANTS AND GRID INTEGRATION EXPERIENCE 2010 –Friday 23 th April Óscar Alonso Teresa Arlabán Alberto García Alejandro González.
ECE 4411 Dynamic Braking of Induction Motors Slow down a machine by converting kinetic energy stored in the rotating mass to heat energy in the rotor and/or.
Overview of different wind generator systems and their comparisons 2-4~2-7 陳昱希.
Harmonic Mitigation in Wind Turbine Energy Conversion Systems Harmonic Mitigation in Wind Turbine Energy Conversion Systems C u r t i n & P U C R S Fernando.
Power Systems Consulting and Software 4 March 2004 BWEA Conference: UK Offshore Wind 2004 Integration of Offshore Wind Farms into the Local Distribution.
1111Challenges for reliable offshore transformersTRANSFORMING YOUR NEEDS INTO SOLUTIONS Challenges for Reliable Offshore Transformers Dr. Jan.
Importance of advanced simulations of electrical system in wind turbines April 2010.
1 GENERATORS AND CONVERTERS IN LOW AND MEDIUM VOLTAGE WIND ENERGY CONVERSION SYSTEMS Dr. Josep Bordonau (Technical University of Catalonia, Barcelona,
Sensorless Maximum Power Point Tracking in Multi-Type Wind Energy Conversion Systems Presenter: Lingling Fan University of South Florida Tampa, FL
ET2105 Electrical Power System Essentials
AC MOTOR INDUCTION MOTOR.
Reactive Power, Voltage Control and Voltage Stability Aspects of Wind Integration to the Grid V. Ajjarapu ) Iowa State University.
Stephan Meier, Staffan Norrga, Hans-Peter Nee
SINTEF Energy Research 1 Fault ride-through testing of wind turbines Presented by: Olve Mo Paper co-authors: John Olav Tande Leif Warland Kjell Ljøkelsøy.
HomeNextPrevious I. INTRODUCTION II. WIND TURBINE GENERATOR MODEL III. STATCOM MODEL IV. SIMULATION RESULT CONTENTS OF TOPIC V. CONCLUSION Previous HomeNextHomePreviousNextHome.
POWER SYSTEM PROTECTION
1. Introduction 2. E-On Guidelines 3. Modelling 4. Controller Design 5. Simulation Results 6. Conclusion Voltage Regulator for Reactive Power Control on.
Frankfurt (Germany), 6-9 June 2011 W. Niederhuemer – Austria – RIF Session 4 – Paper PROBABILISTIC PLANNING FOR A HIGHER INTEGRATION OF WIND TURBINES.
A Novel Control Scheme for a Doubly-Fed Induction Wind Generator Under Unbalanced Grid Voltage Conditions Ted Brekken, Ph.D. Assistant Professor in Energy.
Voltage grid support of DFIG wind turbines during grid faults
1 TRANSMISSION SYSTEM OVERVIEW NETWORK OPERATING COMMITTEE April 17, 2007 New Mexico Transmission System Overview.
(C) 2006, SUCCESS by DESIGN Surge Values at Each Test Stator surged to fault Indicates decrease in dielectric strength following each test. Applied Surge.
RARF DATA for TYPES 3 & 4 WTGs Fault Current Contribution for Current Limited Resources Ed Geer, P.E. Network Model Engineer, Sr. SPWG Meeting July 17,
Closed loop control.
© O. Anaya-Lara – EWEC 2006, Athens, Greece 1 EWEC 2006 – IEA ANNEX XXI SPECIAL SESSION Assessment of structural dynamics for model validation of induction.
Harmonic Analysis of a DFIG for a Wind Energy Conversion System Lingling Fan, Ph.D., P.E. Assistant Professor Dept. Electrical Engineering University of.
Abram Perdana, Ola Carlson Dept. of Electric Power Engineering
MODELING AND SIMULATION OF WIND TURBINE –DOUBLY FED INDUCTION GENERATOR (WT-DFIG) IN WIND FARM USE MATLAB/SIMPOWERSYSTEM Student : TRUONG XUAN LOC.
EET 306 ELECTRIC MACHINES Syafruddin Hasan.
Analysis of a 1.7 MVA Doubly Fed Wind-Power Induction Generator during Power Systems Disturbances Slavomir Seman, Sami Kanerva, Antero Arkkio Laboratory.
Study of TFPM machines with toothed rotor applied to direct-drive generators for wind turbines Maxime R. Dubois LEEPCI, Dept. of Electrical Engineering.
CCU Department of Electrical Engineering National Chung Cheng University, Taiwan 風力發電期末報告 Short-Circuit Current of Wind Turbines With Doubly Fed Induction.
Simulation results for powering serial connected magnets Daniel Siemaszko, Serge Pittet OUTLINE : Serial configuration of full rated converters.
M.E.F. Mechanical Energy Factory Mechanical Power Converter & Re-Generator System.
Future Electrical Generator Technologies for Offshore Wind Turbines Dennis Morosoff The Siberian Federal University.
EFFECTS OF VOLTAGE IMBALANCE ON 3-PHASE INDUCTION MOTORS DESIGN TEAM 3.
Introduction of Types Of WTGs With Respect to Grid Interconnection in Pakistan Hassan Jafar Zaidi CEO, Power Planners International Member IEEEPak Seminar.
Voltage Sag Response of PWM Rectifiers for Variable-Speed Wind Turbines by Rolf Ottersten, Andreas Petersson and Kai Pietiläinen financial supported by.
TECHNICAL PAPER ON SIMULTANEOUS AC-DC POWER TRANSMISSION
Overview OF MULTI Mega Watt WIND TURBINES and wind parks
Superconducting Fault Current Limiter
AC Machines. BOOSTER Basic Function:- -Sometimes when we use electrical power we need different voltage level to main supply. It is provided by Booster.
Utilize Distributed Power Flow Controller (DPFC) to Compensate Unbalanced 3-phase Currents in Transmissions Systems By UNDER THE GUIDENCE OF.
 The common type of wind power generators are squirrel cage induction generator (SCIG),doubly fed induction generator (DFIG)  For more secure and.
Low Scale Grid Emulator Test Bench For In-house Validation Of High Power Converters Oriented To Offshore Speaker: Markel Zubiaga
Power Electronics and Control in Wind Energy Conversion Systems
A Project Review On POWER QUALITY IMPROVEMENT IN GRID USING STATECOM
Unit – IV Starting and Speed control of Three phase Induction motor
Modular Multilevel Converter for Wind Energy Storage Systems
IG BASED WINDFARMS USING STATCOM
Electric Machine Induction Motor
D. Menniti, N. Sorrentino, A. Pinnarelli, M. Motta, A. Burgio and P
Induction motor control
Wind turbine technology
Exam 2 Wednesday, Nov 16, 2016, 5-6:20pm
ECE 333 Green Electric Energy
Why is starter necessary for a three-phase induction motor?
Reinaldo Tonkoski Jr., Fernando Soares dos Reis,
H. Polinder, S.W.H. de Haan, J.G. Slootweg, M.R. Dubois
Sami Repo Tampere University of Technology FINLAND
Generator Equations Galore
Presentation transcript:

D. Aguglia & R. Rebeschini Power Transformer Role for Gearbox Mechanical Stress Mitigation during Voltage Dips Applied to Doubly-Fed Induction Generator Based Wind Turbines D. Aguglia & R. Rebeschini windpower@trasfor.ch rebeschini@trasfor.ch Trasfor S.A. , Customized Transformers & Inductors 6995-Molinazzo di Monteggio, Switzerland. www.trasfor.com

Outline Motivations - Gearbox failures statistics Crowbar protection system for DFIG Worst fault conditions & gearbox mechanical stress Series transformer connection as a solutions for gearbox protection Adapted specifications for a series transformer Conclusion

Motivations - Gearbox failures statistics Gears failures issues (data: 2000–2004, Sweden) Failure frequency Downtime Data from: J. Ribrant, « Reliability performance and maintenance – A survey of failures in wind power systems », M.Sc. Thesis.

Crowbar protection system for DFIG Main purpose : Power converter protection during grid faults Crowbar designed to protect rotor side power converter. Specifications impose to remain connected to grid during faults/voltage dips. This protection system impose an over dimensioning of the gearbox!

Worst fault conditions & gearbox mechanical stress 3-phase to ground short-circuit on a 1.5MW DFIG using crowbar protection system. Worst case at full load operation !

Worst fault conditions & gearbox mechanical stress Phase to ground short-circuit on a 1.5MW DFIG using crowbar protection system. Worst case at full load operation !

Worst fault conditions & gearbox mechanical stress Phase to phase to ground short-circuit (to 0V) on a 1.5MW DFIG using crowbar protection system. Worst fault! Worst case at full load operation !

Worst fault conditions & gearbox mechanical stress Summary for crowbar protection system efficiency Designed to protect power converter. Not suitable for gearbox/gears protection. Implies gearbox over-dimensioning. Faulty peak torque must be reduced!

Series transformer connection as a solutions for gearbox protection Series connection to the grid Classic shunt connection Injection of series voltage during Grid voltage dips Voltage dip seen by DFIG Faulty DFIG currents and torque attenuated! Series connection

Series transformer connection as a solutions for gearbox protection Series connection to the grid …through H Bridges Advantages: possibility to compensate unbalances during “normal operation”. Drawback: more switches!

Series transformer connection as a solutions for gearbox protection Series connection to the grid …through conventional 2-level power converter Advantages: classic topology with less switches. Drawback: difficult to compensate asymmetrical faults.

Adapted specifications for a series transformer Design specifications of series transformer The series connection system should be designed taking into account the steady-state and fault operation. Steady-state analysis Active power balance imposed by DFIG! Turbine’s power is a cubic function of the wind speed

Adapted specifications for a series transformer Steady-state analysis DFIG stator current flowing through series transformer : Igrid = Is In hypo-synchronous operation DFIG stator voltage increases! grid Grid voltage selection issues! In hyper-synchronous operation DFIG stator voltage decreases! Series voltage already with the right phase angle. Ready to react against faults!!! Transformer maximal voltage ~0.5 p.u.

Adapted specifications for a series transformer Steady-state analysis - Transformer maximal current 1 p.u.!!! - Max voltage 0.5 p.u. - Transformer apparent power increased!!! Transformer & converter ratings Different currents seen by the GSC – losses are not the same!

Adapted specifications for a series transformer Fault operation analysis Worst DFIG operation range for faults behavior Series voltage already in the right polarity & ready for protection during faults. If series transformer rated at 0.5 p.u., possibility to provide 50% of voltage. That means the worst voltage dip seen by DFIG is 50% only…enough to protect gearbox!

Conclusion Crowbar protection system contributes to gearbox mechanical stress – need for over-dimensioning. Series transformer topology very interesting for fault ride-through capabilities & decrease of gearbox dimensions. Steady-state specifications analysis is enough to guarantee a good series transformer design for gearbox mechanical stress reduction. Series transformer will have a slight apparent power increase compared to shunt topology.

Please refer to our paper for details and contact us: Thank you very much! Trasfor S.A. , Customized Transformers & Inductors 6995-Molinazzo di Monteggio, Switzerland. www.trasfor.com Please refer to our paper for details and contact us: windpower@trasfor.ch rebeschini@trasfor.ch

Worst fault conditions & gearbox mechanical stress Peak torque & peak rotor voltages depends on fault time occurrence.

Power transformer role & Solutions for new protection systems As WT size increases, generator’s voltages will be higher and higher. A power transformer for DFIG rotor connection to the grid will be needed! OR: