AC Mitigation Overview Mike Tachick Dairyland Electrical Industries, Inc.
Mitigation requirements Connection to low impedance grounding DC isolation of CP system Addressing lightning, AC faults Complying with codes
AC Power Effects Steady-state induction Fault current/voltage Can be measured Fault current/voltage Usually estimated/modeled Conductors, grounds sized for estimated fault current
Background: AC and Lightning Compared Amplitude Time (milliseconds) Time (microseconds) Alternating Current Lightning
AC Voltage Mitigation Create a low impedance AC path to ground Have no detrimental effect on the CP system Provide safety during abnormal conditions (AC fault, lightning)
Factors Affecting Mitigation Key Factors… Soil resistivities, layers Proximity to power lines Power line loading Quality of pipeline coating …and many others
AC Mitigation Design Best performed by consulting engineers using specialized software Evaluates coating stress, step and touch potentials, fault current, steady-state current, grounding arrangements, etc. Typical for larger projects, new construction
AC Mitigation Design CP personnel can roughly estimate or experiment Practical for small projects, single locations Trade-off: optimizing design vs. efficiently installing estimated requirements
AC Mitigation Design Induced voltage is ongoing nuisance AC faults are significant risk Design should consider lightning hazards Control step and touch potentials
Step Potential
Touch Potential
Typical Field Values Open circuit voltage: up to 50V Short circuit current: up to 30A Can exceed these values
Field Measurements Open circuit voltage: voltmeter from pipe to grounding system Short circuit current: AC ammeter – reads current in a bond between pipe and ground
Mitigation Example Problem: Open-circuit induced AC on a pipeline = 40 V Short-circuit current = 15 A Then, source impedance: R(source) = 40/15 = 2.7 ohms Solution: Connect pipeline to ground through decoupler
Mitigation Example Typical decoupler impedance: X = 0.01 ohms 0.01 ohms << 2.7 ohm source 15A shorted = 15A with decoupler V(pipeline-to-ground) = I . X = 0.15 volts Result: Induced AC on pipeline reduced from 40 V to 0.15 V
Local Mitigation Reduces pipeline potentials at a specific point (typ. accessible locations) Commonly uses existing grounding systems Needs decoupling
Local Mitigation High Low Voltage on Pipeline
Continuous Mitigation Reduces pipeline potentials at all locations Provides fairly uniform over-voltage protection Typically requires design by specialists
Continuous Mitigation Gradient control wire choices: Zinc ribbon Copper wire Not tower foundations!
Mitigation Wire Installation
Reasons to DC Decouple From Grounding Systems If not decoupled, then: CP system attempts to protect grounding system CP coverage area reduced CP current requirements increased CP voltage may not be adequate But simultaneous AC grounding is also needed…
Decoupler Characteristics High impedance to DC current Low impedance to AC current Passes induced AC current Rated for lightning and AC fault current Fail-safe construction Third-party listed to meet electrical codes
Typical Decoupler Ratings Threshold: 2-3V peak AC impedance: 0.01Ω DC leakage: <<1mA @ 1V AC fault: 2 to 10kA Lightning: 75-100kA
Typical Decouplers
Typical Decouplers
Zinc Ribbon for Mitigation Provides CP if not isolated Affects CP if impressed current system is used Doesn’t allow instant-off readings when not isolated Grounding effectiveness changes with zinc consumption Can pick up stray currents
Copper for Mitigation Common, low cost material Must be decoupled with suitable device
Grounding Materials If decoupled… CP system not affected Allows instant-off readings Lengthens grounding system life Avoids stray current pick up
Typical Mitigation Site
Typical Mitigation Site
Typical Mitigation Site
Typical Mitigation Site
Typical Mitigation Site
Other Grounds Casings at road crossings Station grounding system Existing metallic vault Abandoned pipeline Culvert Other metallic structure with low resistance to earth
Mitigation - Other Issues Risks at insulated joints Other affected facilities Hazardous locations
Mitigating at an Insulated Joint
Mitigating at an Insulated Joint Provides AC mitigation for pipeline Provides over-voltage protection for insulated joint Easy location to test, install
Other Affected Facilities Transfer of AC fault conditions to other structures Goal is to keep voltage from rising, control current flow Doesn’t mean that current will not get on your pipeline or others Accomplished by bonding, grounding
Example site Road Metering Station Casing I J Power line Substation Pipeline I J
Example site Road Metering Station Casing I J Power line Substation Pipeline I J
Hazardous Locations Accomplish mitigation while complying with codes Determine your site classification Use certified (listed) products and methods Keep conductors short to limit over-voltage, possible arcing, due to lightning
Hazardous Locations CFR 192.467 – combustible atmospheres and insulated joints CFR 192 incorporates the National Electrical Code “by reference” NEC defines hazardous locations and product requirements
Questions? For follow up questions: mike@dairyland.com