W e m a k e i d e a s c o m e a l i v e For internal use only Covering all your needs for Fem-Pop Interventions.

Slides:



Advertisements
Similar presentations
Stenting: tips and tricks
Advertisements

W e m a k e i d e a s c o m e a l i v e 001SCB For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength.
Case presentation: Critical Limb Ischemia
W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only Flexibility and Precision in Peripheral Arteries 0.035” OTW Self- Expanding.
PCI Unmet Clinical Needs
Balloons and Wires Adam B. Greenbaum, MD Associate Director, Cardiac Cath Lab Henry Ford Heart and Vascular Institute No relationships to disclose in relation.
Subtitle Text Here Zylon Medical Devices Smaller Is Better Supported by NIH SBIR PHASE II Grant # 5 R44 H
MECHANICAL GLIDE PATH & PREFLARING
Medtronic Engager™ Transcatheter Aortic Valve Implantation System Procedure Quick Review And Tips August 2013 Innovating for life. UC a EE Engager.
W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only Not only a peripheral stent available in Renal sizes...
Vicon Rau X-SEM Product information 2014.
Guide wires in CTO PCI Dr.C.G.Bahuleyan, MD,DM, FRCP(UK), FSCAI
Θεματική ενότητα: Stenting
Technical Presentation – Amy Dendulk
2 Introduction Drug-eluting stents have defined a new era in the successful treatment of coronary artery disease However, like any therapy, DES results.
Wires, Catheters & Supplimentary Equipment
Evaluation of ReeKross balloon catheter in treating iliofemoral artery chronic total occlusions Xinwu Lu Vascular Center of Shanghai Jiaotong University.
Confidential: Internal Use only 1 Click to edit Master title style Click to edit Master text styles – Second level Third level – Fourth level » Fifth level.
Featuring CTO Complex-PCI by Trans-radial Approach CTO Case review 5 French TRI CTO of right coronary artery -5 F Launcher guiding Catheter (right Judkins.
Product Training Europe July 2002
INTRODUCTION TO NEUROFORM ATLAS
The First Affiliated Hospital of Harbin Medical University
Featuring Bifurcation Trans-Radial Approach Technical Issues Martial Hamon Caen, France Provisionnal T stenting With the Frontier stent Main Branch Balloon.
ClearWay™ RX Therapeutic Perfusion Catheter. ClearWay™ RX In Action Potential Advantages of ClearWay TM: Delivers drug at high concentration to site of.
Presents the new 3-Dimensional Open Loop Designed AndraSnare& AndraSnare Micro.
Overview of Balloon Catheter
Overcoming difficult access in intracranial interventions: A to Z
D.DELEANU, M.CROITORU BUCHAREST, ROMANIA. BTK Interventions ? BTK disease = claudication and CLI BTK interventions = CLI Main goal of CLI therapy = functional.
Michael J. Cowley, MD, MSCAI
The Endocross Enabler-P: First in-Human Results
A new technique of IVUS guided CTO PCI
Retrograde Distal Pedal Artery Access
Takashi Ashikaga,MD,PhD
Product Specifications
Bifurcation Balloon & Stent Delivery System
Direct Flow Medical Experience with a Conformable, Repositionable, Retrievable, Percutaneous Aortic Valve Reginald Low MD University of California,Davis.
Wire Externalization, Snaring and Removal
Direct access of the SFA: step by step
James P. Zidar, M.D., F.A.C.C., F.S.C.A.I
Understanding Stent Deformation
Retrograde Pedal Artery Access
ClearWay™ RX Therapeutic Perfusion Catheter
CAS –Strategy, Pitfalls, and Safety Issues
Anatomy of Contemporary CTO Guidewires and Selection Criteria
A Novel “Stent-On-A-Wire”Ultra Low Profile Stent Delivery System
Prairie Cardiovascular Consultants
A Fixed Guidewire Stent Delivery System
From: The Design of an Improved Force Focused Angioplasty Catheter
How to do endovascular mechanical thrombaspiration
SFA Access for TASC D lesions.
ALPHEUS FLUID TRANSFER SOLUTIONS DOCK HOSE 2017
Case presentation: Critical Limb Ischemia
Recanilization of Central Venous Total Occlusions
Essesntials for CTO Recanalization
T7 – POLYPROPYLENE PLEATED CARTRIDGES
James P. Zidar, M.D., F.A.C.C., F.S.C.A.I
Venous System Interventions for Device Implantation
Endovascular aortounifemoral grafts and femorofemoral bypass for bilateral limb- threatening ischemia  Takao Ohki, MD, Michael L. Marin, MD, Frank J. Veith,
Percutaneous balloon fenestration in a case of traumatic abdominal aortic dissection with lower extremity ischemia  Kengo Nishimura, MD, Yasushi Kanaoka,
NEW GENERATION STENT COBALT-CHROMIUM SIROLIMUS ELUTING STENT.
Strategy based on Thrombus-Grade for Management of the STEMI Lesion
Intra-Aortic Balloon Pumps
Θεματική ενότητα: Stenting
Ciaglia Blue Dolphin percutaneous technique.
Nicolas Mouawad, MD, Chief and Medical Director, Vascular and Endovascular Surgery, McLaren Bay Region A Tale of two lesions.
Presentation transcript:

W e m a k e i d e a s c o m e a l i v e For internal use only Covering all your needs for Fem-Pop Interventions

W e m a k e i d e a s c o m e a l i v e For internal use only Specifications Catheter design Range of diameter Range of length Guide wire compatibility Usable shaft length Balloon material Coating Shaft diameter Introducer compatibility Nominal pressure RBP Over the wire, coaxial lumen shaft Ø 2 – 7 mm (with half sizes) 20, 30, 40, 60, 80, 120, 150 mm 0.018“ 90, 130, 180 cm FLEXITEC™ Xtreme Distal shaft, 23cm LFC-hydrophilic Balloon “Bikini”-coating 3.9 F 4F up to Ø 6 mm, 5F for Ø 6.5 and 7 mm 7 bar (9 bar for Ø 2 mm) up to 25 bar

W e m a k e i d e a s c o m e a l i v e For internal use only Features & benefits  NEW shaft material  For strong pushability and best kink resistance, combined with excellent flexibility  Unique size mix with high RBP  Balloon diameters from 2 to 7 with balloon lengths up to 150 mm  NEW balloon material FLEXITEC™ Xtreme  For improved flexibility and extreme scratch resistance while maintaining high RBPs  Tack weld on the shaft  To avoid accordion effect and improved pushability

W e m a k e i d e a s c o m e a l i v e For internal use only FLEXITEC™ Xtreme NEW balloon material FLEXITEC™ Xtreme with Reduced balloon wall-thickness for improved flexibility Facilitated controlateral manoeuvers Extreme resistance against scratching Heavy duty work in severely calcified lesions Allows multiple inflation without changing performance Controlled Low Compliance Excellent proven Controlled Low Compliance For perfect adaptation to the vessel dimensions and disease condition High rated burst pressures To achieve the desired angioplasty-result Balloon material

W e m a k e i d e a s c o m e a l i v e For internal use only Balloon Hydrophilic Coating  NEW BIKINI coating  The distal shaft and the balloon cones are covered with a LFC-hydrophilic coating  for easy crossing and re-crossing  for enhanced stability during dilation (no-slipping of the balloon)  for facilitated retrieval of the balloon after multiple inflations into the introducer sheath uncoatedcoated

W e m a k e i d e a s c o m e a l i v e For internal use only Balloon profile  6-folding balloon  For lowest crossing profile, best refolding and safe retrieval, even after several inflations.  Lowest Profile  4F introducer sheath compatibility for less possible puncture trauma and new tapered tip profile of 0.018” for successful lesion crossing Ø 2.0 mm Ø 2.5x120, 2.5x150 mm Ø 2.5 – 4.0 mmØ 5.0 – 7.0 mm

W e m a k e i d e a s c o m e a l i v e For internal use only Lowest tip entry and crossing profile

W e m a k e i d e a s c o m e a l i v e For internal use only Rated Burst Pressures

W e m a k e i d e a s c o m e a l i v e For internal use only Size Mix Balloon Ø/Length 20 90/130/ 180cm 30 90/130/ 180cm 40 90/130/ 180cm 60 90/130/ 180cm 80 90/130/ 180cm /130/ 180cm /130/ 180cm  6.5 7.0