NCSLI 2013 Conference 1 How to Achieve a 0.01 µV/V Deviation on Your 10 Vdc Proficiency Test Without using a Josephson Array Author:Gary Bennett – National.

Slides:



Advertisements
Similar presentations
Multiple Indicator Cluster Surveys Survey Design Workshop
Advertisements

Cornerstone Base Station for Calibration Management Applied System Technologies, Inc N.W. 53rd Street, Suite 101 Fort Lauderdale, Florida
Evaluation of Load Cells for Legal Metrology at NIST Kevin Chesnutwood Mechanical Engineer Mass and Force Group Physical Measurement Laboratory.
Copyright Alan Rowley Associates Steps to an Accurate Result Select a method and validate it as suitable for the purpose envisaged. Establish that.
NCSLI 2007 A PRIMARY FLOW CALIBRATION SYSTEM FOR THE SUPPORT OF HIGH PERFORMANCE GAS FLOW TRANSFER STANDARDS P. Delajoud, M. Bair, C. Rombouts, M. Girard.
Cornerstone Cal Station for Calibration Management Applied System Technologies, Inc N.W. 53rd Street, Suite 101 Fort Lauderdale, Florida
1 NCSLI Conference 2013 Inter-Laboratory Comparison Study Using Modular Instrumentation and Lessons Learned Author:Dimaries Nieves – National Instruments.
Dual Wavelength Isotope Ratio FS-CRDS Thinh Q. Bui California Institute of Technology ISMS 2014.
Lecture 4 Measurement Accuracy and Statistical Variation.
Copyrights © 2006 Silliker, Inc. All Rights Reserved Challenges In Validating Analytical Methods in an Independent Lab.
Medical Device Quality Assurance د فضل الاكوع المدير العام أستاذ مساعد بقسم الهندسة الطبية دكتوراه في الأجهزة الطبية – جامعة القاهرة
CH 1 Introduction Prof. Ming-Shaung Ju Dept. of Mechanical Engineering NCKU.
REPUBLIC OF SLOVENIA MINISTRY FOR THE ENVIRONMENT AND SPATIAL PLANNING SLOVENIAN ENVIRONMENT AGENCY Vojkova 1b, 1000 Ljubljana p.p. 2608, tel.: +386(0)1.
Short Course on Introduction to Meteorological Instrumentation and Observations Techniques QA and QC Procedures Short Course on Introduction to Meteorological.
ISRAEL ELECTRIC CORP. METER TESTING LABORATORIES DEPARTMENT STANDARDS LABORATORY.
1 Practical Interpretation of Unbroken Chain in Metrological Traceability as to VIM 3 Center for Measurement Standards (CMS) Industrial Technology Research.
ME 322: Instrumentation Lecture 5 January 28, 2015 Professor Miles Greiner Lab 3, transmitter characteristics, least-squares, standard error of the estimate.
NCSLi 2011 Conference Calibration Software Uncertainty Implementation Philosophies and Practices Speaker/Author : Jorge Martins.
ITRI Industrial Technology Research Institute 2014 NCSL International Workshop and Symposium 1 Evaluation of Proficiency Testing Results with a Drifting.
Metrological issues for food consumption data. Max Feinberg INRA.
Improving Test Ratios Using Reference Multimeters.
Arsine Detection using Chemcassette ® Technology.
Procedure Writing Basics Mr. Richard Crisler Spring-2006.
1 pH observed with Honeywell pH electrodes Current Plan for Calibration and Cleaning Gel replacement Checking with Buffers pH: SATURN-03; SATURN-04.
MG 1/10/01 1 PCS SMOV-3B Review Objectives Overview Activity Descriptions Requirements.
LECTURER PROF.Dr. DEMIR BAYKA AUTOMOTIVE ENGINEERING LABORATORY I.
Quality Control – Part II Tim Hanley EPA Office of Air Quality Planning and Standards.
Dynamics to determine calibration intervals SAAMF Roadshow Durban CSIR NML Eddie Tarnow Metrologist: Torque & Automotive 14 June 2006.
1 Presentation Template: Instructor Comments u The following template presents a guideline for preparing a Six Sigma presentation. An effective presentation.
MatroVal A Calibration Software With Advanced Uncertainty and Prediction Capabilities Including Complex Numbers Alex Lepek Newton.
Lecture 3 Mechanical Measurement and Instrumentation MECN 4600 Department of Mechanical Engineering Inter American University of Puerto Rico Bayamon Campus.
Williams, A.: Measurement Uncertainty© Springer-Verlag Berlin Heidelberg 2003 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical.
Why do we need to do it? What are the basic tools?
Networks in Engineering A network consists of a set of interconnected components that deliver a predictable output to a given set of inputs. Function InputOutput.
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Comparison of CA Evaluation Protocols, CA Framework, IPMVP and CPUC Policy Manual* A preface to group discussion *In terms of how they define.
USE OF UNCERTAINTY OF MEASUREMENT IN TESTING ROHAN PERERA MSc ( UK ), ISO/IEC Technical Assessor, Metrology Consultant.
A new method for first-principles calibration
BME 353 – BIOMEDICAL MEASUREMENTS AND INSTRUMENTATION MEASUREMENT PRINCIPLES.
Tykey Truett Center for Transportation Analysis Oak Ridge National Laboratory (865) or ROLLOVER WARNING!! Truck Roll Stability Data.
CHAPTER 2 GMI | Production Technology. BASIC INSPECTION AND PROCEDURES Learning Objectives Define and differentiate measuring and gauging List the advantages.
NCSLI Dan Newcombe, State of Maine Metrologist Slide # 1 A Measurement Standard for Evaluating Metrology Positions Presented by: Dan Newcombe State.
Advances in High Current and Resistance Measurements to 11,000 Amps and Higher Guildline Instruments Limited.
INL Standards and Calibration Laboratories (S&CL) - Our Road To the Josephson Junction. MIKE STEARS.
Recommended Guide for Determining and Reporting Uncertainties for Balances and Scales Val Miller NIST Office of Weights and Measures.
MIKES-Kajaani CLEEN MMEA Certainty Seminar Petri Koponen Group manager.
Science, Measurement, Uncertainty and Error1 Science, Measurements, Uncertainty and Error.
Home Reading Skoog et al. Fundamental of Analytical Chemistry. Chapters 5 and 6.
Limited Calibration …. it’s not a dirty word! (Calibration Practice Impact on Business) Author: Phil Mistretta NCSLI Orlando, FL 6 Aug 08 Section 6C Metrology’s.
Unsing Manufacturers’ Specifications NCSLI th to 10 th August 2006 Using Manufactures’ Specifications as Type B Uncertainty Contributions NCSLI.
ProCal Calibration Lifecycle Setting Up and Performing a Calibration.
1 How Does Temperature Non-uniformity of an Annealing Furnace Affect SPRT Stability? Speaker: Mingjian Zhao Authors: Mingjian Zhao, Rose Heaton, Rong Ding,
RP-16, Verification of Laboratory Environments Presented by: Doug Cooper TAC.
Overview of Instrument Calibration Presents by NCQC, India.
Calibrating DC Current Shunts: Techniques and Uncertainties Jay Klevens, Ohm-Labs, Inc. © 2011.
National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce Power Loading Effects in Precision 1  Resistors.
Development of a Standard Practice for the Calibration of Torque-measuring Instruments for Verifying the Torque Indication of Testing Machines Speaker/author:
THEORY OF SAMPLING MMEA Certainty Seminar Markku Ohenoja 1 Markku Ohenoja / Control Engineering Laboratory
MECH 373 Instrumentation and Measurements
Product Presentation T12 Thermometer.
Lesson 1-9 Quality Assessment.
AMEK 2013 SCIENTIFIC CONFERENCE & EXHIBITION
Additive Manufacturing Measurement Uncertainty Emerzon Cruz Guandique
NCSLI 2014 Traceability Considerations for the Characterization of Measuring Systems Charles D. Ehrlich NIST Office of Weights and Measures Physical.
Setting Up and Performing a Calibration
Mechanical and Aerospace Engineering
This teaching material has been made freely available by the KEMRI-Wellcome Trust (Kilifi, Kenya). You can freely download,
آشنايی با اصول و پايه های يک آزمايش
By : M. Dlamini D. Jonker E. P. Tarnow
AN EXAMPLE OF SUBSTANCE OF PAPER AS CTP
Presentation transcript:

NCSLI 2013 Conference 1 How to Achieve a 0.01 µV/V Deviation on Your 10 Vdc Proficiency Test Without using a Josephson Array Author:Gary Bennett – National Instruments Metrology Laboratory Manager Speaker: Jorge Martins – National Instruments Principal Metrology Engineer

NCSLI 2013 Conference 2 Learning Objectives Activities required to maintain a 10 Vdc reference standard Tools available to make precision 10 Vdc transfer measurements Overview of techniques to track measured values and project future values of precision standards

NCSLI 2013 Conference 3 Opportunity for Internal Support Need to perform artifact calibrations on Fluke 5720A to maintain the 90 day specifications Purchased: – 4x 10 Vdc Reference Standards –Data Proof VoltRef SW and 160B scanner –Nanovoltmeter

NCSLI 2013 Conference 4 Requirements 10 Vdc uncertainty for calibrator adjustment is: ±1.5 µV/V 10 Vdc Reference Stability Specification

NCSLI 2013 Conference 5 Options Expand the 90 day specification of the 57x0 as per mfg. manual Shorten interval of 10 Vdc Zener references Buy a 10 Vdc with history … that you can trust! Devise a process to expedite the characterization of our Zener References

NCSLI 2013 Conference 6

7

8 Our Chosen Method Calibrate all 4 using MAP program after six months. –Measure the travelling standard Create procedure to measure the travelling standard Review the previous 6 months of VoltRef data Determine uncertainty –Measure all our 10 Vdc references against the travelling standard using the MAP provider’s procedure

NCSLI 2013 Conference 9 Measurements Prior to 2 nd Calibration

NCSLI 2013 Conference 10 Result of 1 st Proficiency Test

NCSLI 2013 Conference 11 What Happened?

NCSLI 2013 Conference 12 2 nd Calibration

NCSLI 2013 Conference 13 2 nd Calibration Results

NCSLI 2013 Conference 14 3 rd Calibration 2 nd Proficiency Test

NCSLI 2013 Conference 15 3 rd Calibration, 2 nd Proficiency Test

NCSLI 2013 Conference 16 Proficiency Test #2

NCSLI 2013 Conference 17 Projected Values and 3 rd Calibration

NCSLI 2013 Conference 18 3 rd Calibration

NCSLI 2013 Conference 19 Proficiency Test #3

NCSLI 2013 Conference 20 4 th Calibration

NCSLI 2013 Conference 21 Proficiency Test #4

NCSLI 2013 Conference 22 5 th Calibration

NCSLI 2013 Conference 23 5 th Calibration Cell #1

NCSLI 2013 Conference 24 Uncertainty Components Calibration Uncertainty (Travelling standard) Atmospheric Pressure Temperature Noise Type A Statistical Uncertainty of Projected Value Hysteresis Error

NCSLI 2013 Conference 25 Conclusion VoltRef works very well with the proper drift information for each cell Tools are available to make the data gathering less painful Understanding the normal differences in performance of individual references is important Gathering history on reference standards is expensive

NCSLI 2013 Conference 26 Questions