1 Product Presentation T12 Thermometer

2 T12 Contents Introduction Key features and USP Specifications
Applications Competitors Target markets Sales Promotion June 2017 © MBW Calibration

3 T12 Introduction Multi-Channel Reference Thermometer
Twelve channel temperature measurement High precision, stability and reproducibility Internal reference resistors PC software for system control and data acquisition Simple to configure and use RS-232 serial interface SCS calibration option June 2017 © MBW Calibration

4 T12 USP Fast 12 channel measurement
Uncertainties at a level that is neglectible in humidity measurement Can be used as reference bridge as well as scanner for validation work Perfect combination with Dew Point Mirrors through GeckoR2 Live relative humidity calculation Temperature probe information can be stored locally or synchronized with server drive 17025 Calibration in resistance value and/or temperature June 2017 © MBW Calibration

5 How does it work? Selectable current (0.33 / 0.67 / 1 mA)
4-wire measurement Current +/- Known resistance values on hidden channels Linear fit to measurand A/D value June 2017 © MBW Calibration

6 How does it work? June 2017 © MBW Calibration

7 How does it work? June 2017 © MBW Calibration

8 How does it work? June 2017 © MBW Calibration

9 T12 Specifications Measuring Ranges Temperature Resistance
°C (PRT Pt-100) 0…380 Ω Performance Resolution Accuracy (T12 only) Temperature coefficient for the range of -200…250 °C 0.1 mK ≤ ± 2 23 °C (95% confidence level, 1 year) 0.1 mK/ °C June 2017 © MBW Calibration

10 Why performance from -200 … 250 °C ?
Usual range for all our humidity applications Tested by NSAI National Metrology Laboratory, Ireland Input Range 16.8 to 140 Ω Evaluated range. Repeatability Ω Repeatability 0.5 mK Linearity Ω Long Term Stability Ω /year Evaluated at start and end of seven month period, after exposure to temperature extremes (5°C to 40°C). Long Term Stability 0.18 mK/year Temperature Coefficient 0.05 ± mK/ °C Based on device exposure from 5°C to 40°C. RMS Measurement Noise Ω June 2017 © MBW Calibration

11 History data from MBW lab T12
June 2017 © MBW Calibration

12 T12 Applications Climatic Chamber Validation part of the IEC 60068
Requires nine sensors for temperature measurement June 2017 © MBW Calibration

13 T12 Applications Climatic Chamber Validation
Combine with dew point mirror for relative humidity values June 2017 © MBW Calibration

14 T12 Applications Temperature calibration Calibration by comparison
Validation of fluid baths June 2017 © MBW Calibration

15 T12 Applications Ice Point Check your working standard
Check your T12 probes Simple, but precise! (<5 mK) June 2017 © MBW Calibration

16 T12 Maintenance T12: only calibration PRT
Calibration using a set of fixed resistors PRT Ice Point Check Internal comparison Internal or external recalibration June 2017 © MBW Calibration

17 T12 Competitors Fluke (Hart) Blackstack June 2017 © MBW Calibration

18 T12 Competitors ASL F200 June 2017 © MBW Calibration

19 T12 Promotion Opportunity Development:
Development divisions, validation of sensors and calibration setups Combination with 473 -> Chamber validation June 2017 © MBW Calibration