EMFA 7.2kV-365kV Next Generation Actuator for Middle & High Voltage Circuit Breaker Head office : EMATECH San 56-1 Shillim-dong Kwanak-Gu Seoul Korea Phone.

Slides:



Advertisements
Similar presentations
Seminar on Circuit Breaker
Advertisements

Inspection & Preventive maintenance of breakers
QUALITY AND TECHNOLOGY
HYDRAULICS & PNEUMATICS
© Copyright year ABB. All rights reserved /1/2015 VBF OUTDOOR VACUUM CIRCUIT BREAKER 36kV PRODUCT INFORMATION.
Circuit Protection  Protective Devices – terminate current flow in a circuit.  Located in series within a circuit  Excessive current flow results from.
October, 2009 VM1: innovation in power technology Vacuum circuit-breaker with magnetic actuator Product presentation 1VCP – Rev. C, en – Presentation.
Conversion of energy from one form to another Creating useful energy for a certain task Can use any type of energy.
Conversion of energy from one form to another Creating useful energy for a certain task Can use any type of energy.
Elec467 Power Machines & Transformers
EXCITATION SYSTEM.
Model Continuous Workstation Monitor, Dual Wire ©Copyright 2003 DESCO INDUSTRIES INC.
Alexander Barnaveli GEORGIA №1. Electromagnetic cannon A solenoid can be used to fire a small ball. A capacitor is used to energize the solenoid coil.
1 Jun Watanabe R&D status of highly efficient Stirling-type cryocooler for superconducting drive motor J Watanabe, T Nakamura, S Iriyama, T Ogasa,
Electromagnets!Electromagnets! By Jack and Bella.
Electro-Pneumatics Module 1
Electromagnetism Kyle Thornton DMI 50B. Magnetic Attraction and Polarity n ava/magneticlines/index.html
© 2008 Snap-on Incorporated; All Rights Reserved.
Discussion #27 – MotorsECEN 3011 Faith and Works James 2: Even so faith, if it hath not work, is dead, being alone. 18 Yea, a man may say, Thou.
Lesson 9: Electrical Components
Toyota Prius Study case.
Electromagnetic Induction
Chapter 9 Magnetism.
Electricity and Magnetism
Levels of high voltage: World over the levels are classified as: LOW MEDIUM HIGH EXTRA and ULTRA HIGH Voltages However, the exact magnitude of these levels.
Electromagnetic Induction Create electric current from changing magnetic fields.
Electricity Electric Charge Electric Charge Static Electricity  Conductors  Insulators  Electroscope  Transferring Charge.
Pneumatics.
MagnetismSection 3 Section 3: Electric Currents from Magnetism Preview Key Ideas Bellringer Electromagnetic Induction The Electromagnetic Force Transformers.
Need for protection Power system must be kept in operation continuously without major breakdowns This can be achieved in two ways: 1.Implement a system.
ELECTRICAL CELLS & CURENTS. DRY CELL & WET CELL Wet Cell – the electrolyte is a liquid (car battery) i. In a car battery, Electrolyte is sulfuric acid.
Faraday’s Law and Inductance. Faraday’s Law A moving magnet can exert a force on a stationary charge. Faraday’s Law of Induction Induced emf is directly.
Lecture 9: Modeling Electromechanical Systems 1.Finish purely electrical systems Modeling in the Laplace domain Loading of cascaded elements 2.Modeling.
ELECTRIC DRIVES INTRODUCTION TO ELECTRIC DRIVES. Electrical Drives Drives are systems employed for motion control Require prime movers Drives that employ.
Physical Science Chapter 18
A Presentation On Construction Of Turbo Generator
What is Mechatronics? The portmanteau "Mechatronics" was first coined by Mr. Tetsuro Mori, a senior engineer of the Japanese company Yaskawa, in 1969.
1 © 2015 Eaton. All Rights Reserved.. Suggestion on How to Use Industry Trainers are encouraged to use this material in their sessions Download the presentation.
A Presentation on construction of Turbo Generator.
Transducers – changing one form of energy to another Piezoelectric Microphone Ultrasound Motors/Generators Switches Solenoids Relays EAPs Overview.
HIGH VOLTAGE UNION Vacuum Circuit Breaker 110 kV VRS-110 Series ВЫСОКОВОЛЬТНЫЙ СОЮЗ
The Different Types of Inductors and Their Affecting Factors
INTRODUCTION TO ROBOTICS Part 3: Propulsion System Robotics and Automation Copyright © Texas Education Agency, All rights reserved. 1.
VACUUM CIRCUIT BREAKER. WHAT IS A CIRCUIT BREAKER A circuit breaker is an equipment that breaks a circuit either manually or automatically under all conditions.
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
 An electron passes perpendicularly through a magnetic field at a velocity of 2.0x10 7 m/s. The strength of the magnetic field is 0.25 T. What is the.
INVERTER TECHNOLOGY.
1 Figure 17.1 A Rotating Electric Machine. 2 Configurations of the three types of electric machines Table 17.1.
CLOSED LOOP SPEED CONTROL OF DC MOTOR WITH PWM TECHNIQUE
E Control Devices have a wide range of Latching Relays. The range of latching includes Relays, 16 Amp Latching Relays, 30Amp Latching Relays, 80 Amp Latching.
© ABB HV Products - Page 1 A REVOLUTION IN CIRCUIT BREAKER OPERATING MECHANISM TECHNOLOGY CARILEC July 2002 Jamaica Kenneth Jabrand.
TITEL OF PRESENTATION :- ANALOG MEASURING INSTRUMENTS PREPARATION NAME ENROLLMENT NO.:  MR.SAVALIYA SURESH T  MR. SAVALIYA VISHAL H
CNC FEED DRIVES.
SINGLE-PHASE INDUCTION MOTOR
From Lecture1 vi , ii vo , io Power Processor Controller Source Load
Presentation on Actuators.
CONTINUOUS-DRIVE ACTUATORS**
3AH5 Vacuum Circuit-Breaker For Standard Applications
3AH5 Vacuum Circuit-Breaker For Standard Applications
Peter Erning, PSP-T11, Power Gen 2010
Single phase motors are very widely used in home, offices, workshops etc. as power delivered to most of the houses and offices is single phase. In addition.
From Lecture1 vi , ii vo , io Power Processor Controller Source Load
LVDT You’re expected to learn
3AH5 Vacuum Circuit-Breaker For Standard Applications
CrystaLatchTM 1x1,1x2, Solid-State Fiberoptic Switch
Presented by Applied Energy LLC
CrystaLatchTM 1x2 PM Bidirectional Fiberoptic Switch
Performance Specifications
Performance Specifications
Presentation transcript:

EMFA 7.2kV-365kV Next Generation Actuator for Middle & High Voltage Circuit Breaker Head office : EMATECH San 56-1 Shillim-dong Kwanak-Gu Seoul Korea Phone : U.S. office : EMFA-LAB 3943 Irvine Blvd #113 Irvine blvd Phone : EMATECH Co., Ltd. E LECTRO M AGNETIC F ORCE driving A CTUATOR

EMFA has a characteristic of one of the electrical actuator with a moving coil, because it can satisfy the requirements of high voltage circuit breaker extremely well for large stroke length and high power. Besides, EMFA is possible to attach it in a small spacer due to having a compact volume. EMFA is developed and designed by Seoul National University, Electro-mechanics Lab. Next Generation Actuator (EMFA) What is EMFA Rail-gun type The worldwide first electric actuator for high voltage circuit breaker Patent : Seoul National University, Electromechanics Lab. EMFA (Electro-Magnetic Force driving Actuator) is designed for mechanism drive of middle & high voltage circuit breaker. The high voltage circuit breaker requires the actuator to be capable of carrying extremely high power during a long stroke length and short breaking time. However pneumatic, hydraulic, spring and permanent magnetic actuator are considered expensive, nosily and are not used wide. EMFA-III [for Gas Circuit Breaker] EMFA-I [for Vacuum Circuit Breaker] EMATECH Co., Ltd.

Next Generation Actuator (EMFA) Basic structure Planner and tubular type Coil moving type actuator Latch itself using by auxiliary permanent magnet 4 parts - laminated iron core, permanent magnet, inserted iron core, coil [ Structure of EMFA ] Inserted Iron Core Main Permanent Magnet Auxiliary Permanent Magnet Sing Coil [ Cross section of EMFA ] [ Magnetic flux density on the iron core ] S-45 steel EMATECH Co., Ltd.

Next Generation Actuator (EMFA) EMFA series EMFA - I for 50kV class Vacuum Circuit Breaker SubjectEMFA -I Stroke8 – 60 mm Contact force1,000 – 10,000 N (3 phases) Energy20 – 46 Joules velocity open m/s close m/s EMFA - II for 72kV class Gas Circuit Breaker SubjectEMFA –II Stroke60 – 140 mm Repulsive gas Force 5,000 – 14,000 N (3 phases) Energy100 – 1,500 Joules velocity open m/s close m/s EMFA - III for 145kV class Gas Circuit Breaker SubjectEMFA –III Stroke100 – 200 mm Repulsive gas Force 20,000 – 60,000 N (3 phases) Energy1,500 – 15,000 Joules velocity open m/s close m/s EMATECH Co., Ltd.

Next Generation Actuator (EMFA) Advantages of EMFA High reliability Small space and volume requirements This circuit breaker, adapted EMFA, is passed on KERI according to new revised IEC standards (IEC & IEC ) Compact size in minimized number of components and high power during long stroke Application of circuit breaker by high quality EMFA without any mechanical components Small size and light weight resulting from variable circuit breaker type High security No need latch mechanism (Hold the electrode position by itself) Optimum operation through extendible increasing or decreasing rated capability Outstanding harmony of the environment Lower noise by adapting magnetic system Modern industrial design and use friendly Protection against pollution by electromagnetic type Enhancement self-diagnosis Anytime check the status of actuator stand-by state and its dynamic characteristics as well as electrode Controlling the velocity of the moving part during traveling Alarm the emergency state on the system to safety supervisor and consumer through the ubiquitous system EMATECH Co., Ltd. ●●●●●● ● ●●●● ●●●●●● ●●●●●●

Next Generation Actuator (EMFA) EMFA - I for Vacuum Circuit EMATECH Co., Ltd.

Patented system with better performance than Motor Spring Actuator and Permanent Magnetic Actuator Ability to vary speed and self-adjust time according to the environment, programmable and maintenance-free Smaller than 30% volume size Higher energy efficiency 40% over other electrical actuators Much more dependable and less prone to breakage and failure Only one component working to opening or closing the electrodes Enhancement the maintenance-free system Uses far less energy than other electrical actuators Next Generation Actuator (EMFA) General Features of EMFA - I for Vacuum Circuit Breaker EMATECH Co., Ltd. ●●●● ●

Next Generation Actuator (EMFA) EMFA - III for Gas Circuit Breaker EMATECH Co., Ltd.

The worldwide first electric actuator for high voltage circuit breaker (IEC & IEC ) Patented system with better performance than Motor Spring Actuator and Hydraulic Actuator Smaller than half of volume size Higher energy efficiency 40% over other electrical actuators Ability to vary speed and self-adjust time according to the environment, programmable and maintenance-free Enhancement self-diagnosis Anytime check the status of actuator stand-by state and its dynamic characteristics as well as electrode Controlling the velocity of the moving part during traveling Next Generation Actuator (EMFA) General Features of EMFA - III for Vacuum Circuit Breaker EMATECH Co., Ltd. ●●●● ●●●●

EMFA is controlling the electrodes during its working on opening or closing by adapting DC/DC converter EMFA driver system is very sensitive as well as actuator itself, due to high efficiency Next Generation Actuator (EMFA) EMFA control system Stroke Curve of EMFA Open msec mm Close Power supply Main signal Control signal Signal from sensor Trip signal IO AC DC Charging Unit I/O Unit Converter Unit Capacitor Unit Actuator Resolver Control Unit EMATECH Co., Ltd.

Increasing management of Power System through the networking system Next Generation Actuator (EMFA) Information Technology on Power system By adapting power system total solution, consumption administer and security of power system as well as supplying company High quality power can be supplied to consumers Communication Relay System i i KEN Center LAN Security of Power System Consumption Administer CB Distribution System Local Optical Communication Global Optical Communication Fire wall C/S server Monitoring B/L server DB server Web server EMATECH Co., Ltd. ●●●●

Seoul National University, Electro-mechanics Lab. EMATECH Elector-Magnetic Actuator Technology Co., Ltd. Head Office San 56-1( ) Shillim-dong Kwanak-Gu Seoul Korea, Phone : Fax : Website : U.S. Office (EMFA_LAB) 3943 Irvine Blvd #113 Irvine blvd Phone : , Research Center San 56-1( ) Shillim-dong Kwanak-Gu Seoul Korea Phone : Cel : Fax : Website : Copyright ⓒ 2007 EMATECH Co., Ltd. All rights reserved. EMATECH Co., Ltd.