Testing Ferroelectric and Piezoelectric Samples in an AFM Radiant Technologies, Inc April 22, 2004.

Slides:



Advertisements
Similar presentations
Instructional Presentation
Advertisements

UVM CricketSat Assembly Manual. Getting Started Make a hard copy print out of the following page It will help you identify the proper components Place.
Piezoelectric Characterization in an AFM Joe T. Evans, Jr, Radiant Technologies, Inc.
Introduction to electronics lab ENGRI 1810 Using: Solderless prototype board (white board) Digital multimeter (DMM) Power Supply Signal Generator Oscilloscope.
Introduction to (SMAW) Shielded Metal Arc Welding
Electricity & Types of Circuits- Page TSW DESCRIBE DIFFERENT FORMS OF ENERGY (ELECTRICITY).7.4- TSW DESCRIBE DIFFERENT FORMS OF ENERGY (ELECTRICITY).
Now its time to explore the beginning of starting your engine, the Ignition System By: Stephen.
Electromagnetics for 8th grade
Cutnell/Johnson Physics 8th edition
Vertex2002, Kailua-Kona, HI 11/07/02 B. Quinn1 Carbon Fiber Grounding Issues in the DØ Run IIb Silicon Detector Design Breese Quinn Marvin Johnson, Mike.
Investigating static charge
Unit 6: Working With Electricity
ACTFEL Alternating Current Thin Film Electroluminescent Lamps.
Level Sensors.
ECE 404 PCB Design Presentation Jakia Afruz.  Printed Circuit Board  Electronic Board that connects circuit components  PCB populated with electronic.
Sensors used in EFI (Electronic Fuel Injection)
Residential Wiring Facts
Thermocouple A thermocouple or thermocouple thermometer is a junction between two different metals that produces a voltage related to a temperature difference.
Circuits 6-1.
Wiring the Desklamp Basics of Wiring. Types of Wire For this project we will be using two types of wire: 3 wire and standard lamp wire. – 3 wire The wire.
Performance of the DZero Layer 0 Detector Marvin Johnson For the DZero Silicon Group.
Electrical Fundamentals
How Does Electricity Flow? Electricity & Magnetism Science Instructor: Miss Aartman.
RM2C Understanding Connections on the Robot Control Board (RCB).
Electricity and Magnetism Chapter 13
Energy Energy = ______________________ – Waves carry energy from one place to another – Light and sound both move in Waves.
What ARE all those little things anyway?
Cells and Batteries Section 1.4
Bidirectional field-flow particle separation method in a dielectrophoretic chip with 3D electrodes Date : 2012/12/24 Name : Po Yuna Cheng( 鄭博元 ) Teacher.
Development and Implementation of a Polarization Measurement System
Training Making accurate Electrical Measurements.
Neuroprosthetics Week 5 Stimulating and recording of nerves and neurons.
12. Power Distribution Systems 1) Schematic diagram of part of a house wiring system 1.
Trinity Charging Experiment Gregg Harry, MIT On behalf of Dennis Ugolini, Trinity LIGO-G R.
Additional Physics – Forces L/O :- To know what happens when insulating materials become charged Static Electricity Exam Date -
1 EE462L, Spring 2014 Electronic Components. 2 Our power electronic switches Diodes (a.k.a. rectifiers) Thyristors (a.k.a. silicon controlled rectifiers,
Crossover Cable Construction
Energy Energy = travels in WAVES –Waves carry energy from one place to another –Light and sound both move in Waves.
CircuitProtection, Tips, and Troubleshooting Fall 2015 ECE 445.
Unit 2: Electricity Lesson 8: Household Electricity.
Basic Electrical Circuit Materials Colts Neck High School Applied Technology.
11/22/2004EE 42 fall 2004 lecture 351 Lecture #35: data transfer Last lecture: –Communications synchronous / asynchronous –Buses This lecture –Transmission.
1 Device Simulations & Hardware Developments for CBM STS Sudeep Chatterji CBM Group GSI Helmholtz Centre for Heavy Ion Research CBM Collaboration Meeting,
+ - The moment this switch is closed energizing this electromagnet time  we expect the current jumps from zero to I = V/R time switch is closed.
How do electric charges flow in a circuit? Pgs Chapter 5: Electricity Lesson 1:“ What Lights the Night?”
UCLA IEEE NATCAR 2004 SUMMER CLASS Magnetic Sensors & Power Regulation.
CONDUCTION, INSULATION AND PROTECTION. CONDUCTION Energy (eg. Electrical) transfer from one material to another by direct contact. Conductors are materials.
Electromagnets D. Crowley, 2008.
Electric Charge & Static Electricity Like charges repel one another while opposite charges are attracted to one another. Law of Electric charge--
Antenna Project in Cameron clean room Wafer preparation, conductor deposition, photolithography.
SPM Users Basic Training August 2010 Lecture VIII – AC Imaging Modes: ACAFM and MAC Imaging methods using oscillating cantilevers.
ADVANCED WATER LEVEL CONTROLLER
Roughness and Electrical Resistivity of Thin Films Spencer Twining, Marion Titze, Ozgur Yavuzcetin University of Wisconsin – Whitewater, Department of.
Absolute Displacement Calibration for Atomic Force Microscopy
Development of T3Maps adapter boards
Electric Current and Electrical Energy.
Circuits.
Potential and Current Control
Unit 45: Circuits and components Dr
Oscilloscope.
Schematic diagram of part of a house wiring system
SWITCHES W. C. “Buster” Hounshell Spring 2002.
1) Schematic diagram of part of a house wiring system
HVI HIPOT TEST SET Pft sERIES.
Circuits Objective: I will understand how electricity flows in a simple circuit.
Binary Resonant Wings Joe Evans, Naomi Montross, Gerald Salazar
To install the four wires from the back of the coil machine, loosen the four knobs. Insert each of the four wires from the side under the knobs. Keep each.
Domestic Electricity AIM: To understand the use of domestic electricity and safety features such as fuses, circuit breakers and the earth circuit
Wiring the Light and Relay
Binary Resonant Wings Joe Evans, Naomi Montross, Gerald Salazar
Presentation transcript:

Testing Ferroelectric and Piezoelectric Samples in an AFM Radiant Technologies, Inc April 22, 2004

Connecting to the Sample with Conducting Tip The sample rests on the AFM chuck and electrical connections are made to the sample one of two ways: –Connections for the chuck and the conducting AFM probe tip come out to BNC connectors on the AFM. NOTE: This arrangement will only work if the chuck is NOT grounded but instead is insulated from the AFM. DRIVE => Chuck BNC RETURN => Conducting Probe Tip BNC –The AFM chuck is grounded and a conducting tip is used. In this case, a wire must be connected between the bottom electrode and the tester. DRIVE => wire to bottom electrode of sample RETURN => Conducting Probe Tip BNC Sample MUST be isolated from the chuck by an insulator. A glass slide, a piece of electrical tape, or a piece of paper will do.

Optimal Sample Connection The optimal connection to the sample is as follows: –Wire from DRIVE to bottom electrode. –Wire from RETURN to bottom electrode –Chuck is grounded –Sample is insulated from the chuck. –Non-conducting AFM probe tip is used. This arrangement provides for the lowest noise injection.

AFM Frequency Response The vertical position control system for the AFM usually has a response speed on the order of 80KHz. However, the control system itself has a response on the order of 100Hz. To prevent distortion of the piezoelectric butterfly loop by the 100Hz response time of the AFM, the butterfly loops should run at around 1Hz (1000 millisecond period on a Radiant Precision tester). Electrical hysteresis speed is affected only by sample size, not AFM response time. Capacitors of 100µx100µ area can run at full speed on Radiant Precision Tester for electrical hysteresis.

Limitations of Conducting AFM Probe Tips The use of the conducting AFM probe tip to contact the top electrode of the sample capacitor is very convenient, especially for small capacitors. During the switching phase of the hysteresis loop, the current density in the conductive coating of the probe tip is high enough to ablate metal off the probe tip. Consequently, conductive probe tips have a limited number of loops they can measure before all of their metal coating is ablated away. If hysteresis measurements are intermittent or contact cannot be made to the target electrode, the conducting probe tip should changed prior to looking for other problems. Slow test frequencies (i.e.1Hz) will significantly increase probe tip life time.

Noise Ground noise is a significant problem in AFMs. To minimize it, follow the instruction below. –Make the measurements with the AFM chuck grounded and the sample insulated from the chuck. –Make sure that the chuck is grounded to the rest of the AFM and then connect the AFM ground to the green ground plug on the rear of the Radiant Precision Tester. –If at all possible, connect the Radiant Precision tester to the same power outlet as the AFM. Other Noise –When a conducting probe tip is used, the connection runs through the AFM to the probe tip. This connection can pick up the high voltage fields of the AFM control system and thus will inject noise into the measurement. Use a conductive tip only if necessary. –When using a conductive tip, try the RETURN connected to the tip. If this is too noisy, reverse it and connect the DRIVE to the tip.

Connection Diagram Precision Tester RETURN SENSOR DRIVE Insulator Chuck Conductive Tip AFM A wire must run directly between system grounds. AFM Output Signal

Sample Prep for Conducting Tip Silicon wafer with platinum or gold coating. Test Cap Etched Via to BE Epoxy or Dried Photoresist Nickel Print or Silver Print Heavy Gauge Wire

Using Sample for Conducting Tip

Sample Prep for Non-conducting Tip Strip a stranded wire to get a single strand and attach it to the sample capacitor with silver print or nickel print.