R ADIATION S AFETY T RAINING B ECKMAN ® LS 6500 L IQUID S CINTILLATION C OUNTER CSULB Radiation Safety Office March, 2013.

Slides:



Advertisements
Similar presentations
Radioisotope Laboratory Techniques Day 2 Environmental Health & Safety Radiation Control & Radiological Services UNIVERSITY OF FLORIDA RADIATION SAFETY.
Advertisements

Radiation Safety Training Lab Survey Program Washington State University Radiation Safety Office.
Chemistry safety Part 2.
Instructions for Wipe Testing for Radioactive Material Contamination
Radiation Safety Program Annual Refresher Training
Radiation Safety Training Radioactive Waste Washington State University Radiation Safety Office.
Liquid Scintillation Counter And Contamination Monitoring Training Presented by: Ali Shoushtarian Office of Risk Management October 2009.
1 HYDROFLUORIC ACID SAFETY Environmental Energy Technologies Division SAFETY TOPICS January 13, 2012.
32 P Module Objectives  To understand the physical nature of 32 P.  To understand the 32 P is both and internal and external radiation hazard.  To understand.
Laser Awareness (Non-User). 2 What is a laser? Laser is an acronym for Light Amplification by Stimulated Emission of Radiation.
Molecular Materials Research Center Beckman Institute California Institute of Technology.
Annual Refresher Training. Preliminary Procedure in Glassware Washing Contaminated items. Return glassware that contains chemicals or contamination to.
2005 Radiation Safety Refresher Training Sue Dupre, Radiation Safety Officer Stephen Elwood, Health & Safety Specialist.
An Introduction to Flame Atomic Absorption Spectrometry (FAAS) Steve Badger and Charity Wessel.
Tulane University - Office of Environmental Health & Safety (OEHS) HAZARDOUS MATERIAL SPILLS For Tulane Laboratory and Facilities Employees May 2012.
Radiation Safety Course Radiation Monitoring Heath de la Giroday Dispensing Chemist Radiation Safety Officer.
Radiation Detection Systems
PROCEDURES AND REQUIREMENTS FOR THE SAFE USE OF RADIOACTIVE MATERIAL Indiana University - Bloomington.
3 H Module Objectives  To understand the physical nature of 3 H.  To understand that 3 H is both an internal and external radiation hazard.  To understand.
Personal Protective Equipment Wear gloves any time that you could come in contact with radioactive material. Select glove based on the chemical(s) in use.
Radiation Safety Training Annual Refresher Training Washington State University Radiation Safety Office.
University of Washington Department of Chemistry Recommendations for Chemical Waste Management (a supplement to the online training module for handling.
Zettl Group Safety Talk ~Fume Hoods~ 09/28/06 Takashi Ikuno.
R ADIATION S AFETY T RAINING PE W IZARD ® G AMMA C OUNTER CSULB Radiation Safety Office March, 2013.
Instructions for Radiation Waste Submittal (e-102 form) Steve Parker 4/5/04
Module 7 RADIOACTIVE WASTE HANDLING, STORAGE AND DISPOSAL.
Introduction into LS theory and practice. Agenda  Energy deposition  Overview of the LSC process  Theory of operation  Quenching  Machine  Uses.
Lab Safety in the Ausubel Lab Jake Begun – Your radiation officer.
Nuclear Physics: Radiation, Radioactivity & its Applications.
2004 Radiation Safety Refresher Training Sue Dupre, Radiation Safety Officer Stephen Elwood, Health & Safety Specialist.
Measurement and Detection of Ionizing Radiation
Radiation Safety at Tufts Helpful Hints for Radioisotope Users.
. 2 RCRS provides: Pick-up and delivery of meters Required 9-month calibration Preventive maintenance and repairs Shipping for extensive repairs RCRS.
Introduction to Operation of the XL- 30 Scanning Electron Microscope Tutorial # 2 Introduction to Operation and Imaging.
PPE – glove selection Wear gloves any time that you could come in contact with radioactive material. Select glove based on the chemical(s) in use. Be aware.
Standard Microbiological Practices UT Biosafety Office
Instruments for Radiation Detection and Measurement Lab # 3 (1)
Student Safety Orientation. Origin of Safety Rules School Rules Classroom/Laboratory Rules Lab Safety Rule Agreement National Science Education Standards.
WELCOME TO THE FIRST RMWEA SAFETY WEBINAR! Hosted by: Karen Shanley- Safety Committee Chair Blair Corning- Online Training Committee Chair.
School Safety Training
Radiation Safety Training: Procedures University of Alaska Fairbanks September 2013.
Radiation Safety Training Module 3 – UGA Site Specific Procedures.
RADIATION SAFETY ORIENTATION COURSE. Ionizing Radiation - can deposit energy in neighboring atoms resulting in the removal of electrons. NUCLEAR RADIATION.
1 HAZARDOUS MATERIAL IDENTIFICATION SYSTEM. 2 A TRAINING PRESENTATION OF THE BRUNSWICK HILLS POLICE DEPARTMENT.
7. EMERGENCY RESPONSE RYERSON UNIVERSITY.
RADIO IMMUNOASSAY DANIEL CASAL.
Half-life It's impossible to predict when a specific atom is going to decay, but you can predict the number of atoms that will decay in a certain time.
Mr. Banerjee’s Science Classroom 1 Lab Safety Pages
 Radiopharmaceuticals are agents used to diagnose certain medical problems or treat certain diseases. They may be given to the patient in several different.
Extremity Dose Reduction By Aggie Barlow, CHP, MS, MBA.
LSM780 Live Cell Turn On/Turn Off Instructions Kim Peifley 07/13/15.
Pre-Lab 10B: Determining Freezing/Melting Point
R ADIATION S AFETY O FFICE TDG Class 7 Receiving Presentation Code 62 1 Transportation of Dangerous Goods Class 7 - Receiving Some content with permission.
Radiation Safety Program Transportation of Dangerous Goods Class 7 – Receiving Some content with permission and thanks from the Dalhousie University Radiation.
3/2003 Rev 1 II.3.4 & 13-15a – slide 1 of 31 Part IIQuantities and Measurements Module 3Principles of Radiation Detection and Measurement Session 4,Liquid.
SAFETY IN THE LABORATORY 1-Don`t eat, smoke or drink inside the laboratory. 2-Don`t put any thing in your mouth such as pens, fingers…. 3-Don`t take.
Laboratory Procedures Chemical Management Emergency Laboratory Equipment m.inmagine.com CH5, CH6, CH10.
Determination of Concentration Using Spectrophotometry
By following safety rules in the lab, you will help keep both yourself and others safe. Safety Rules.
Scintillation Counter
DS200 PROCEDURES SPEAKER TOUCH SCREEN DISPLAY
Topic: Radioactive Waste Management By: UCLA Radiation Safety Division UCLA Radiation Safety Continuing Training Click ‘NEXT’
Louisiana State University Radiation Safety Office
CSULB Radiation Safety Office March, 2013
CHME-wide Safety Stand down
Waste and Contamination
Juanita Miller, PE, CFEI NMSU COE Safety ECI Room coesafety.nmsu.edu
Instructions for Wipe Testing for Radioactive Material Contamination
Safety Training Molecular Materials Research Center Beckman Institute
Diagnostics Analytical 920 LC Semi-Prep 940 LC
Presentation transcript:

R ADIATION S AFETY T RAINING B ECKMAN ® LS 6500 L IQUID S CINTILLATION C OUNTER CSULB Radiation Safety Office March, 2013

Welcome This PowerPoint presentation provides an overview of how to use the LSC for qualitative purposes such as for contamination surveys. You will be provided detailed instructions on specific LSC counting methods and materials by experienced personnel in your particular lab. Proper use of the LSC is monitored by supervisor, the IRUA holder for whom you work and by Radiation Safety as a part of their audits of your radiation safety program compliance.

Topics What is a Liquid Scintillation Counter? Liquid Scintillation Counter Overview Step by Step Procedures for LSC Things to Consider

What is a Scintillation Counter - LSC? A liquid scintillation counter is a machine that measures ionizing radiation, predominantly beta radiation such as 14 C, 3 H, 35 S and 32 P. It will measure gamma radiations, but at a reduced efficiency. Only use the LSC to measure gamma emitters for monthly swipes when your lab uses both gamma and beta labeled materials – not for data collection. Gamma emitters in LSC vials are expensive and difficult to dispose of. A scintillator is a material that generates photons of light in response to incident radiation. In LSC, the scintillator is the cocktail (LSC fluid) added to a counting vial. Radiation emissions from a radiolabled sample “excite” molecules to generate light. Sensitive photomultiplier tubes (PMT) measures the light from the scintillator. The PMT are attached to electronic amplifiers and other electronic equipment to count the signals produced by the photomultiplier tubes.

Liquid scintillation counter Details Samples are dissolved or suspended in the LSC fluid which is an organic solvent containing small amounts of additives known as fluors which increase performance. Radiation emitted from the sample transfer energy to the solvent molecules, which in turn transfer their energy to the fluors; the excited fluor molecules dissipate the energy by emitting light. In this way, each beta emission results in a pulse of light

Beckman® LS 6500 Scintillation Counter This is located in MLSC-214

Liquid scintillation counting Overview Samples and Scintillation Cocktail are mixed. Lids must be screwed on tightly. Samples are placed in the counting racks. Counting racks are labeled with a user number card. The number on the card activates a specific counting program entered into the machine’s hard drive. Racks are then loaded onto conveyor with a rack having the “STOP” card in place. Sample compartment is closed and counting is begun.

How to perform counting using LSC Wearing lab coat and gloves, add sample ( swipes or experimental ) to scintillation vial.

How to perform counting using LSC Add Scintillation Cocktail Note: Chemical splash goggles, gloves and lab coat are required when dispensing common brands of scintillation cocktail. Use of a fume hood to eliminate exposure is recommended. Review the MSDS for the cocktail you are using. Do NOT use any of the older formulations that contain toluene. Toluene based flammable cocktails are to be surrendered as hazardous waste.

How to perform counting using LSC Secure lid tightly

How to perform counting using LSC Place vial(s) in counting rack Use secondary containment if transporting glass or open vials Note: The fiberboard “egg crate” flats vials come in from the factory are considered acceptable containment for vial transport.

How to perform counting using LSC Note: There are two slots in each rack. Use extreme care when inserting cards to avoid jamming a card in the wrong slot! Add user number to rack

How to perform counting using LSC Open sample compartment

How to perform counting using LSC Place samples in LSC The card must face the inside sensors

How to perform counting using LSC Make sure to add “Halt” rack after samples Without this rack in with card facing in, the machine runs on and on…

How to perform counting using LSC Make sure the Printer paper is aligned to top of page and the printer is online. To adjust, press “online” to turn off the online light. Press form feed and check where paper stops. If adjustment needed, use manual feed knob to adjust top of page 2–4 cm from print head. Press online again. Printer is ready. Report printer or machine problems to Radiation Safety

How to perform counting using LSC Initiate counting by pressing “Start” button twice. Sign the Log Book.

How to perform counting using LSC Generic instructions for using the RSO qualatative contamination swipe analysis program are posted on the wall next to the LSC.

LSC Printout A Positive Control is a “standard” made up by the LSC manufacturer or in your lab with a known DPM/CPM value. The LSC value must be within 5% of the standard value. Radiation Safety can provide a factory-made control if desired. Report any inaccuracy. A Negative Control is a “blank” which contains NO radioactive material. To make Such a blank, use the same LSC vials, fluid and matrix you use in your sample vials

Things to consider: User number Radiation Safety personnel employ user #2 for contamination surveys. User #2 is set up to count for two minutes in three windows. These windows delineate a specific energy range and assist in the detection of various nuclides. l--window1--l

Things to consider: User number You may want to set up your own user number with parameters specific to your isotope and experiments. l--window1--l l window l

Things to consider: User number User number 2 can be used for post- experimental surveys and monthly surveys. Or use your own user number/program as long as the windows used can “see” the isotope you are working with. l--window1--l l window l l window l

Things to consider: Quench Quench reduces the light output from the sample and thus affects the accuracy of the cpm. It may result from color in the sample or from chemicals that affect energy transfer in the cocktail or dirty/inked vials. The H# on the printout indicates the extent of quench in the sample and can be corrected for. Please see pg in the user manual. A quench curve can be set up as described on pg. 6-8 of the user manual. Quench is any issue that hides or falsely lowers the true number of light flashes

Things to consider: Chemiluminescence and Lum-Ex Light producing events can occur in a sample that are not a result of radioactivity of the sample. This is called Chemiluminescence. Lum-Ex values, shown on the printout, provide an indication of what percent of the total CPM’s are due to non-radioactive events. If too high, results may be erroneous. If Lum-Ex values are greater than 5 to 10%, steps should be taken to reduce the problem.

When Finished Counting: Remove vials promptly after counting. Remove the print-out showing your counting results. If this is a contamination survey make sure to write on the print-out what was swiped for each vial counted. Transport the vials back to the lab in double containment.

LSC Vial Waste Management Used LSC vials should be stored in the original ‘egg crate’ flats. Flats of used vials must be labeled in the standard manner – use a yellow rad label and enter in the PI name, nuclide(s) and date started. It is understood that some flats contain only vials that are at background levels. The word “trace” may be written on flats of cold vials. Writing <1 microCurie is acceptable as well. When ready for RS pick-up of the vials, complete an entry on the blue log sheet.