Presentation for Florida Building Commission Regional AC Efficiency Workgroup May 9, 2008 Lennox Industries Inc.

Slides:



Advertisements
Similar presentations
Over 50 Years of Regional Service and World-Class Quality United Air Conditioning is a client-focused, family-owned air conditioning company serving.
Advertisements

Why do people live in Florida?. Florida population 1900 to 2004.
Heating, Ventilating, and Air-Conditioning
The Role of Controls for Indoor Air Quality Kent W. Peterson, PE, Fellow ASHRAE P2S Engineering, Inc. Mid Columbia ASHRAE Chapter.
100% Outside Air Systems for Light Commercial Applications ASHRAE Luncheon March 8, 2006 Outside Air Delivery Strategies Direct Reheat Reclaim (DX) Methods.
Key HVAC Design Concepts. Agenda Discuss relevance of thermal enclosure system to HVAC system. Present the three major steps to design an HVAC system.
Components of HVAC System
Heating and Air Conditioning I
Variable Frequency Drives VFD Basics
Station 4 ?? Temperatures and Moisture Moisture Meters Pin Contact Data Loggers Spot Temperature Meter Thermal Imager Cautions and Safety.
C A L I F O R N I A E N E R G Y C O M M I S S I O N 2013 Building Energy Efficiency Standards Residential Zoned AC Discussion August 18, 2011.
AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
Active beams versus VAV with Reheat Analysis of May 2013 ASHRAE Journal article Ken Loudermilk Vice President, Technology & Developement.
Energy use in buildings Dr. Atila Novoselac Associate Professor Department of Civil, Architectural and Environmental Engineering, ECJ
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
F LORIDA S OLAR E NERGY C ENTER A Research Institute of the University of Central Florida Assessment of Energy Efficient Methods of Indoor Humidity Control.
Evaluation of Space Humidity Control and System Energy Usage for Conventional and Advanced Unitary Equipment Michael J. Witte and Robert H. Henninger GARD.
Lecture Objectives: Model HVAC Systems –HW3 Asignemnet Learn about eQUEST software –How to conduct parametric analysis of building envelope.
1 Proposed Changes to the RTF’s Heat Pump Specifications Impact on Estimated Deemed Savings and C&R Discount Program Credits.
Lecture Objectives: Model processes in AHU –Use eQUEST predefined models –Use detail modeling Define your topics for your final project.
BEM CLASS 5 Building Thermodynamics – 2 Air-conditioning Load Calculation – latent heat, solar and internal gains.
Conditioning of Moist Air
1 HVACR416 – Design Principles Air Exchange. 2 HRV’s (Heat Recovery Ventilators)
Introducing. The Comfort Zone (75° /50% RH) Every HVAC system is trying to hit this target. Hot, humid climates High latent load. The Challenge:
Objectives Compare locations in North America Potential for moisture problems Different driving forces Analyze potential for moisture problems in cooling.
Important variables Water: Air: Conversion:
Data Centers - They’re Back… E SOURCE Forum September, 2007 William Tschudi
Announcements Midterm Project Prepare groups of 3 to 4 students You can submit the list at the end of next class Midterm Exam 03/09/10 - In class Exam:
Update on the SEEM Simulation Program Larry Palmiter and Ben Larson August 4, 2008 Ecotope Inc. Presented at Regional Technical Forum Portland, Oregon,
Objectives Finish talking about ways to minimize ventilation losses Discuss role of ducts in building energy use Describe coheating test methodology Interpret.
ASHRAE A Ventilation Standard for Residential Structures Ventilation and Acceptable Indoor Air Quality in Low- Rise Residential Buildings.
Lecture Objectives: Specify Exam Time Finish with HVAC systems –HW3 Introduce Projects 1 & 2 –eQUEST –other options.
Objectives Define psychrometric quantities Continuation from previous class Draw psychrometric processes Relate psychometric variables to human comfort.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
Water is the Natural Choice Water: The Natural Choice For Efficiency – Unit efficiency versus Building System efficiency – Equipment Ratings EER and COP.
Water is the Natural Choice Hydronic Comfort Systems Increase and Maintain Building Efficiency For the Life of Your Building
Water is the Natural Choice Water: The Natural Choice For Efficiency – Building System efficiency not just a unit rating – Equipment Ratings EER and COP.
1 1 Weatherization & Indoor Air Quality Impacts of Weatherization on Air Quality and Comfort Inside Your Home Prepared with the assistance of Jed Harrison,
Development of a new Building Energy Model in TEB Bruno Bueno Supervisor: Grégoire Pigeon.
Objectives Ventilation analysis with HOP Human exposure/IAQ Ventilation and energy.
Development of a new Building Energy Model in TEB Bruno Bueno Grégoire Pigeon.
Design What is the first step in designing a high-performance building? Would it be: Identify synergies Select the correct HVAC system Design around human.
A New (Rational) Way To Condition Air (and Save Energy) AEE, Philadelphia February 18 th 2016 Andrew Mongar, President, AirGreen LLC.
Changing the way the world cools…now in India!
Free Air Cooling for Data Centres
Maria’s Restaurant Chapter 2 Section 9
Building Environmental Systems
The Data Center Challenge
HYDRONIC HVAC: The Most Comfortable and Efficient System
HYDRONIC HVAC: The Most Comfortable and Efficient System
Data Center Research Roadmap
HVAC Basics Arkan Arzesh HVAC – Heating, Ventilation, Air-conditioning.
Munters DOAS, Chilled Beams and VRV
Energy Efficiency in District Coiling System
Brian Wallingford, Applications Engineer
Chilled Beam Performance:
Cheryl Hughes Regional Sales Manager October 6, 2015
Variable Frequency Drive (VFD)
Coleman Commercial Product
HCB 3-Chap 19A: All-Air Systems_Single Zone
Variable Refrigerant Volume
Technician’s Guide and Workbook for Zoning Section 1: Introduction
Zoning Load Calculations
HYBRID AIR COOLING TECHNOLOGY
Minimizing Heating & Cooling Costs
A Ventilation Standard for Residential Structures
Objective Revie the Cooling Cycle Learn about air distribution systems
Maria’s Restaurant Chapter 2 Section 9
Presentation transcript:

Presentation for Florida Building Commission Regional AC Efficiency Workgroup May 9, 2008 Lennox Industries Inc.

About Lennox Industries Inc.: Lennox is a U.S. Residential and Commercial HVAC Manufacturer Over 100 years young Over 6000 dealers Nationwide operations Four-time EPA Energy-Star Partner of the Year Three-time AHRI Performance Award Winner

Comparison Current System of Standards A Regional Scheme EnforcementProduct levelLocal level ManufacturerAny coil combination meets standard Distribution & supply concerns ContractorsProducts for every application & economic need Higher efficiency products only Issues around high efficiency cooling in humid climates…

Problem Statement: In Hot & Humid Climates, sensible load reduction can exacerbate indoor humidity problems. How shall we reduce energy consumption and still provide comfortable and healthy indoor environments? What changes (code and otherwise) will be most beneficial?

Comfort/Health For the cooling season: an indoor temperature of 75F to 77F, with an indoor humidity <55%* is a good goal. *we believe that occasional excursions above 60%, for not more than a few hours at a time, are actually OK.

Cooling Loads Cooling loads are composed of: “sensible” +“latent” = total  Heat conduction  Solar transmitted heat  infiltration/ventilation  Moisture from showers, cooking, etc.  Expiration/perspiration of occupants  Moist air infiltration/ ventilation The ratio of the sensible-to-total load is the SHR; It is determined by the house and its occupants.

Air Conditioner Operation An air conditioner sensible-to-total cooling ratio likewise describes how the unit cools and removes moisture under given conditions. The S/T ratio varies with: Indoor air flow rate Indoor temperature and humidity Outdoor temperature

Air Conditioner Operation The S/T ratio is typically between.80 and.60. So 20% to 40% of cooling is by moisture removal. Low S/T = greater dehumidification CBX32MV-036 AHRI Rating Point

A Balancing Act Most of the time: SHR > S/T …and this is good, excess moisture is removed! If SHR < S/T, then the indoor humidity will rise.

Design: Using ACCA Manual J load calculations (“Design Conditions”) for a Tampa house, we looked at the impact of a design change to reduce the sensible load. The SHR shifts down from.82 to.77 when, in this case, low-e glass was substituted.

Design: The SHR and equipment S/T are still pretty well matched – no problem. But…when it cools off outside: the latent load doesn’t necessarily drop-off like the sensible does!

The potential problem: On a Tampa “Dehumidification Design Day” the SHR difference between these two construction scenarios goes from.62 to.49. At.62 SHR, a conventional AC system, will just manage (indoor RH a little over 60%). With a.49 SHR, the same AC system will allow the indoor RH to drift up, uncontrolled.

Starting with the easiest: 1. Make sure ventilation is “just meeting” ASHRAE Use “AUTO” fan mode (not “FAN ON”) 3. Don’t use a fan overrun timer. 4. Use lower indoor airflow rate ( cfm/ton) 5. Select and condenser/coil combination with low S/T. These practices should be second nature in Florida, but they will be critical in the future. Options for Humidity Control (cont.)

The next easiest (adds to the equipment cost, but will help reduce the number of cooling season hours above 55% RH) 6. Use a modern thermostat, with humidity sensing capability, to: Select a low fan speed when there is excess humidity Allow a few degrees (2 to 4F) of overcooling when there is excess humidity 7. Use an air handler with a highly-efficient variable speed fan in conjunction with above control system (this is for efficiency reasons) Options for Humidity Control (cont.)

The option #6 + #7 has been reported on by Henderson and Shirey*. They found that, for a very high-efficiency home in Miami, the 1500 hours(!) of indoor RH above 60% was reduced by about 1/3. The point is that the #6 + #7 upgrade will not be sufficient for the most “efficient” home designs. *Closing the Gap: Getting Full Performance from Residential Central Air Conditioners, April 27, 2007; Henderson, Hugh and Shirey, Don Options for Humidity Control (cont.)

The last group can greatly reduce the incidence of excess humidity: 8. Install an integrated air conditioning and dehumidification system. Includes components of #6 and #7, but has an new operating mode with S/T ratio below.4, when needed. …or… Options for Humidity Control (cont.)

9. Install a high efficiency*, ducted-type dehumidifier to operate with the air handler to dehumidify the entire home. Options for Humidity Control (cont.) *A few dehumidifiers can perform this function with minimal “energy penalty” (still 13% to 33% see Henderson and Shirey, ibid.) Look for a high ENERGY FACTOR rating! Our company sells all of these systems.

Summary of Performance A seasonal simulation of the 1641 sq. ft. Tampa home (with single-pane windows and then with low-e windows), gave these humidity control results:

Conclusions In hot & humid climates, conserving energy while maintaining a comfortable and healthy indoor environment is going to be a challenge. Low sensible-load homes will require more sophisticated and expensive systems. The designers of homes, including the mechanical sub-systems, must be knowledgeable…or there will be problems. (Use the Dehumidification Design Day as another design point?)

Conclusions (cont.) Our national standards benefit consumers by making a large uniform market for companies to compete in. Regional efficiency standards would fracture that market and increase non-value-added costs. Manufacturers of residential HVAC equipment already provide diverse and comprehensive equipment solutions to handle most any application. Changes in home construction continually spur innovation in the HVAC industry, as companies seek competitive advantage.