Prime Exposure Factors II By Professor Stelmark. Primary Factors The primary exposure technique factors the radiographer selects on the control panel.

Slides:



Advertisements
Similar presentations
Producing an X-ray Exposure
Advertisements

Technique Guidance Systems
Chapter 11 Prime Factors.
Formation Characteristics
The X-Ray Tube Bushong Ch 7.
Chapter’s 2, 3. & 4 By Garland Fisher
Primary Exposure Factors IV
Chapter 7 Radiographic Image Formation and Exposure Factors.
E XPOSURE FACTORS : Contrast, Density, Image Quality, technique math 1.
Dental X-ray Machine 118 Radiology.
ACVR Artifacts Artifacts of Diagnostic Radiology
Analyzing the Image Density. Density Overall blackening of the image.
X-RAY TUBE & EXPOSURES INVERSE SQ LAW CIRCUITRY
Medical Imaging X-Rays I.
X-RAY GENERATOR COMPONENTS
Radiographic Technique Evaluation
Factors affecting the X-Ray output
X-Ray Production & Emission
Exposure Timers By Prof. Stelmark.
Elsevier items and derived items © 2009 by Mosby, Inc., an affiliate of Elsevier Inc. X-Ray Production Chapter 8.
The X-ray Imaging System
X-Ray Production & Emission
3 The Dental X-ray Machine: Components and Functions.
RADIOLOGIC IMAGING EQUIPMENT 1. THE X-RAY ROOM 2.
P RIMARY E XPOSURE FACTORS : Contrast, Density, Image Quality, technique math 1.
Ch. 2 – Anatomy of the X-ray Machine
Resident Physics Lectures
Components of Image Quality & Radiographic Artifacts Radiologic Technology A Spring 2010 Final Final.
Lecture (2). 2 1.Explain how to produce x-rays and discuss its properties 2.List the basic components of the radiographic machine and identify primary.
Fundamentals of X-ray Production
Prime Exposure Factors 1
Chapter 2 The X-ray Beam.
Introduction to Dental Radiography and Equipment
RAD 254 Chapter 15 Radiographic Technique 4 primary exposure factors are: kVp, mA, time, distance.
Factors affecting CT image RAD
RADIOLOGIC IMAGING EQUIPMENT 1. THE X-RAY ROOM 2.
Exposure Factors or Prime Factors
RTEC 111 Bushong Ch 2, 3 &15 Technique Math. Fundamentals of Radiologic Science RTEC 111 Bushong Ch. 2.
Preparing Variable kVp Technique Charts By Prof. Stelmark.
Elsevier items and derived items © 2009 by Mosby, Inc., an affiliate of Elsevier Inc. X-Ray Emission Chapter 9.
PRINCIPLES OF TECHNIQUE AND EXPOSURE
Radiographic Quality Visibility and Sharpness
Radiographic Equipment
Fundamentals of X-ray Production By Professor Jarek Stelmark.
X Rays LO: Describe how electron beams produce X Rays Calculate the current in terms of rate of flow of electrons.
Chapter 10 Exposure Mathematics. Exposure Mathematics u We have seen in Chapter Seven that there are several exposure factors that are predetermined before.
Medical Equipment Technology Department 1 Introduction to Biomed. Imaging Systems Lecture No.5-6 Dr. Yousif Mohamed Y. Abdallah.
Resident Physics Lectures Christensen, Chapter 2C Production of X-Rays George David Associate Professor Department of Radiology Medical College of Georgia.
Image Quality and Patient Dose. X-ray tube design - basic principles Electrons generated by thermionic emission from a heated filament (cathode) Accelerating.
Tube Exposure Factors Math Technique Contrast and Density
Sergeo Guilbaud School of Radiologic Sciences
Radiology Steps in radiation production Kilovoltage and voltage.
RADIOGRAPHIC QUALITY S. Guilbaud, Education Director School of Radiologic Sciences.
 Make and type of x-ray machine  Incoming line voltage  Kilovoltage  Milliamperage and exposure time  Focal film distance/source-imagine distance.
An early x-ray by Wilhem Rontgen
Radiology. The Cathode… Provides a source of electrons and directs the electrons towards to anode. The cathode has a coiled wire filament that emits electrons.
8 November 1895, produced and detected electromagnetic radiation in a wavelength range today known as X- rays or Röntgen rays, electromagnetic radiationwavelengthX-
Radiology Milliaperage. The beam of radiation we use in dentistry may be described in two ways: 1.Quality = penetrating ability - energy of the photon.
Exposure Factors or Prime Factors
Producing An Image RVT: Chapter 6. Learning Objectives: Chapter 6 Understand the 4 factors of radiographic exposure and how each impacts the production.
Technique Guidance Systems By Prof. Stelmark. Anatomic Programming Anatomic programming, or anatomically programmed radiography (APR), refers to a radiographic.
X-Radiation.
Stacy Kopso, M.Ed., RT(R)(M)
Factors Effecting the Production
Exposure Factors Chapter 4
Characteristic Radiation in Tungsten Targets Shell # of electrons Binding energy L Char M N O P Eff X-ray Energy K
Resident Physics Lectures (Year 1)
CHAPTER 7 X-RAY PRODUCTION.
Resident Physics Lectures (Year 1)
Brightness Control Systems
Presentation transcript:

Prime Exposure Factors II By Professor Stelmark

Primary Factors The primary exposure technique factors the radiographer selects on the control panel are milliamperage, time of exposure, and kilovoltage peak (kVp). Depending on the type of control panel, milliamperage and exposure time may be selected separately or combined as one factor, milliamperage/second (mAs). Regardless, it is important to understand how changing each separately or in combination affects the radiation reaching the IR and the radiographic image. Milliamperage mA Exposure time Kilovoltage

The Electric current is a flow of electric charge through a conductive medium. In electric circuits this charge is often carried by moving electrons in a wire The SI unit for measuring the rate of flow of electric charge is the ampere or milliampere. (1/1,000) In radiography mA controls the number of electrons in transit between cathode and anode per unit of time (second). mA setting is associated with the specific temperature of the filament and the number of electrons being liberated. mA is the unit of tube current. The higher the mA the more x-rays are produced Milliamperage

100 mA400 mA

A mA mA 3 -5 A

mA affects the quantity of x-rays produced, it also affects the intensity and the total exposure or primary signal. mA is doubled – exposure is doubled – intensity is doubled. mA Exposure Rate Optical Density

mAtimemAs 50 1 sec sec sec200

Duration of the tube current and radiographic exposure. How long the electrons are flowing between the cathode and the anode. The exposure time ids directly proportional to the number of x-rays generated. Exposure time affect the quantity of x-rays produced It does NOT affect the intensity Exposure Time

Exposure time Exposure Optical Density

mAtimemAs sec sec100 2 sec200

The quantity of x-ray photons in an exposure cannot be determined by either the mA or the exposure time alone. Although mA determines the rate of x-ray production, it does not indicate the total quantity, because it does not indicate how long the exposure lasts. Exposure time does not indicate the total quantity either, because it does not measure the rate of x-ray production. To determine the quantity of radiation involved in an exposure, both mA and time must be considered. mA x Time (sec) = mAs

220 mA x (sec) = 16.94mAs

mAs Exposure Optical Density

As the mAs is increased, the quantity of radiation reaching the IR is increased. As the mAs is decreased, the amount of radiation reaching the IR is decreased.

Changes in mAs have a direct effect on density. A.Original image. B.Decreased in density when the mAs is decreased by half. C.Increase in density when the mAs is doubled.

mAs is the primary controlling factor of the x-ray beam quantity

mAtimemAs sec sec sec400

mAtimemAs sec200 1 sec sec200

mAs formula calculations mAs mA sec

10 mAs 200 mA sec 10 mAs/ 200 mA = 0.05 sec. 0.05sec x 1,000 = 50 ms

10 mAs mA 40 msec 40 ms = 40/1,000 = 0.04 s. 10 mAs/0.04 s = 250 mA

mAs 200 mA 1sec 200 mA x 1 s = 200 mAs

When the kVp is increased at the control panel, a larger potential difference occurs in the x-ray tube, giving more electrons the kinetic energy to produce x-rays and increasing the kinetic energy overall. The result is more photons (quantity) and higher energy photons (quality). Kilovoltage

kV 30 – 150 kVp

The kVp affects the exposure to the IR because it alters the amount and penetrating ability of the x-ray beam. Altering the penetrating power of the x-ray beam affects its absorption and transmission through the anatomic tissue being radiographed. Higher kVp increases the penetrating power of the x-ray beam and results in less absorption and more transmission in the anatomic tissues

mAs is the primary controlling factor of the x-ray beam quality

kVp 2 Exposure rate Optical Density

Primary Exposure Factors and Image Density mA increase mA decrease Time increase Time decrease kVp increase kVp decrease Analog System

Primary Exposure Factors and Image Brightness mA increase mA decrease Time increase Time decrease kVp increase kVp decrease Digital System Same