1 SAFECOM & HTC Smart Powering Grid Patented technology, providing a complete set of unlimited backup Power for CATV networks & Without Batteries US PATENT.

Slides:



Advertisements
Similar presentations
Integrating Opengear console servers into Zenoss monitoring.
Advertisements

Integrating Opengear console servers into SolarWinds Orion NPM
Moxa Embedded Solution on IEC 61850
Safecom's proven patented DPS Ver. 4 & Integrated Power Booster (Patent P) turn existing coax or power cable lines into dynamic super power highways that.
Safecom INGRESS GATE technology (Patent p) 28dB UPSTREAM RF & INGRESS NOISE BLOCKER Solving the “Funneling Effect” at HFC & RFoG networks Allows carrier.
Safecom INGRESS GATE technology (Patent p)
Safecom's proven patented DPS Ver 4 & Integrated Power Booster (Patent P) turns existing coax or power cables lines into dynamic super power highways that.
1 SAFECOM & HTC Smart Grid Patented technology providing complete set of unlimited backup Power for CATV networks & Without Batteries US PATENT 8,415,822.
Vendor Briefing May 26, 2006 AMI Overview & Communications TCM.
Safecom's proven patented SYNERGY-2, DPS Ver 4 & Integrated Power Booster turns existing CATV networks into a super power synergy platform that provide.
1 Pacific Gas & Electric Company MTS: Evolution of the Electric Distribution System Manho Yeung, Senior Director, System Planning and Reliability PG&E.
12-Port IP Power Manager IPM  Product Overview  Product Features  Applications  Comparison Presentation Outline 2 / 15.
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
Delta Confidential DES UPS introduction UPS training June 2006 Markus Schwab.
Safecom's proven patented SYNERGY-2, DPSV4, Power Booster & Dual T-former P.S turns existing CATV networks into a super power synergy platform that provide.
Phaseo Power Supplies ACE Expert Training Presentation 2009.
Safecom INGRESS GATE technology (Patent p) UPSTREAM RF & INGRESS NOISE BLOCKER Solving the “Funneling Effect” at HFC & RFoG networks.
Terry Chandler Power Quality Inc, USA Power Quality Thailand LTD Sept /6/20091www.powerquality.org all rights reserve.
SAFECOM & HTC Smart Grid Patented technology providing complete set of unlimited backup Power for CATV networks & Without Batteries US PATENT 8,415,822.
System Elements HighPoint Broadband Delivery System Sector 1 Sector 3
CONFIDENTIAL 1. 2 Designing the Intelligent Energy Gateway 2009 CONFIDENTIAL.
Intorduction to Lumentis
SPIE, PA-IVKrzysztof Czuba1 Improved fiber-optic link for the phase reference distribution system for the TESLA technology based projects Krzysztof.
Sergey Khudyakov Data Transfer, Inc. Russia Large-scale RF mesh AMR implementation (experience in St.Petersburg)
Submission Slide 1 Project: IEEE P Working Group for Wireless Personal Area Networks (WPANs) Submission Title: [Smart Grid: Faulted Circuit Indicator]
Local Network OFF LEFT UNIT AC-1R LOCAL OFF AC-1L LOCAL OFF AC-2L Remote OFF MAIN-OFF DPS OFF Local Network OFF RIGHT UNIT Press to start AC2 pass only.
The following pages contain a number of architectural designs that can be applied to a broadband network. The application of the SPSM in a network is limited.
Metering Americas April 24, 2006 Advanced Metering.
AC Current An AC circuit consists of a combination of circuit elements and an AC generator or source The output of an AC generator is sinusoidal and varies.
Exit REMOTE POWER SYSTEM ”Turning your copper into gold”
SPD II 1 for LV Power (AC/DC)
IP-based 8-port Switched Power Manager
Online Emergency Lighting Inverter
A Novel Fault Current Limiter
Online Emergency Lighting Inverter
Safecom INGRESS GATE technology (US,EP Patent) 28dB UPSTREAM RF & INGRESS NOISE BLOCKER Solving the “Funneling Effect” at HFC & RFoG networks Allows carrier.
Stand-By Emergency Lighting Inverter
Stand-By Emergency Lighting Inverter
Online Emergency Lighting Inverter
Stand-By Emergency Lighting Inverter
Harsh Environment Power Conditioning Voltage Regulator
Online Emergency Lighting Inverter
Innovation in CATV powering design
Online Emergency Lighting Inverter
Stand-By Emergency Lighting Inverter
Stand-By Emergency Lighting Inverter
Moxa Embedded Solution on IEC 61850
Outdoor Power Conditioning Voltage Regulator
Online Emergency Lighting Inverter
Stand-By Emergency Lighting Inverter
Uninterruptable Power System
Indoor Power Conditioning Voltage Regulator
Online Emergency Lighting Inverter
Online Emergency Lighting Inverter
Stand-By Emergency Lighting Inverter
Harsh Environment Uninterruptable Power System
Online Emergency Lighting Inverter
Speaker : Yu-Ping Chen Advisor : Quincy Wu Date : 2010/01/17
Outdoor Power Conditioning Voltage Regulator
Harsh Environment Power Conditioning Voltage Regulator
Online Emergency Lighting Inverter
PowerLogic™ offer for the basic metering market
Online Emergency Lighting Inverter
Indoor Power Conditioning Voltage Regulator
Stand-By Emergency Lighting Inverter
Stand-By Emergency Lighting Inverter
DIS-200G Series Sales Guide ESPD, July 2017 V1.1.
Online Emergency Lighting Inverter
Stand-By Emergency Lighting Inverter
Simple, accurate tenant sub-metering
Presentation transcript:

1 SAFECOM & HTC Smart Powering Grid Patented technology, providing a complete set of unlimited backup Power for CATV networks & Without Batteries US PATENT 8,415,822 US PATENT 5,747,888

2 Hulda transformers Company Profile:  Established in 1975 and is owned by Kibbutz Hulda.  A part of (KIA) the Kibbutz Industries Association represents over 300 factories & Companies owned by the kibbutz association in Israel.  It total KIA has 35,000 employees & over 8 billions US$ sales/year.

3 Main Markets:  Military & Aviation transformers.  Medical equipment manufacture.  Cable TV industry. Safety standard: CE, BABT, IEC, VDE & UL Quality Assurance Management System: ISO 9001:2008 certified. Hulda transformers Company

4 Mr David Zilberberg Privet company Hulda transformers Company Kibbutz Industries Association (KIA) Kibbutz Organization CATV Upstream noise blocker (UNB) CATV Patented Powering Kibbutz Hulda

Safecom's proven, patented SYNERGY-2, DPSV4, Power Booster & Dual T- former P.S turns CATV Optical & HTC networks into a super power synergy platform that provide most reliable and economic powering system for unlimited backup time. Safecom Smart Powering Grid Patented technology, providing a complete set of unlimited backup Power for CATV networks & Without Batteries DPS v5 Power Booster 4G SYNERGY-2 Dual T-former 2X 15A 60,66,72,87 V + DOCSIS Monitoring 5 Dual outputs T-former 15A (Indoor -Europe Standard ) 60,66,72,87 V

Based on the strategic placing of intelligent power management devices throughout the network, in the event of a power outage the SYNERGY-2 & DPS4 draws power from the distant available source over existing coax or power cables. Utilizing breakthrough direct AC/AC On-Line stabilize technology safecom's SYNERGY-2 and Power Booster ensures an optimal voltage level – even over long distances. The Backup Power concept. 6 Unlimited backup Power for CATV networks & Without Batteries (60V & 90 V standard)

Based on the strategic placing of intelligent power management devices throughout the network, in the event of a power outage the DPSv5 draws power from the distance available source over existing coax or power cables. Safecom's proven smart grid technologies greatly improve network powering reliability while creating significant savings in both capital and operational expenses Power + Signal To remote / Node / Amplifier Optical Node/Trunk amp P.S AC 1 input. AC 2 input Local output to local Optical Node. (AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp) US PATENT EP Power Booster Port Monitoring Port: voltage, RF PASS MHZ AC 1 Local Remote Current, status AC 2 Unlimited backup Power for Optical & HFC networks Without Batteries

 MINIMIZE THE NUMBER OF POWER SUPPLIES IN THE NETWORK.  INCREASING THE POWERING AREA COVERED BY POWER SUPPLY Vin 30-87Vac (US) Vin 30-64Vac (EU ) t v t v Vout 87 Vac (US) Vout 60 Vac (EU) US PATENT 8,415,822 Utilizing patented breakthrough direct on-line zero crossing AC/AC stabilize technology safecom's ensures an optimal voltage level to Optical Nodes & Line Amplifiers even the source of power from over long distances. Passive, Standalone element, power booster solves the power distribution problem in a CATV network caused by high-resistance and low energy efficient coax & electricity cables. 8 RF PASS MHZ

Power Booster – the 4G Transmission 9

All in One two-way RF Pass 1GHZ passive device that “toggle” available Power between two distant locations. Redirecting power from the "normally" remote powered area to the area subject to power outage. During the normal mode of operation, when there is no power outage at either end of the pair, the SYNERGY-2 act as power block to the other side. Utilizing breakthrough step-up & stabilizing voltage technology the unit provides optimal & stable voltage level from local or remote P.S even from very long distance or using a un-stabilized P.S. = DPS V 4 Power Booster US PATENT 8,415,822 AC 1 input. AC 2 input Local output to local Optical Node. (AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp) Power + Signal To remote / Node / Amplifie r Optical Node/Trunk amp P.S Unlimited backup Power for Optical & HFC networks Without Batteries

Inputs/ Output configuration Monitoring Inputs/outputs ONLINE Current & Voltage + status. AC 2 - InputAC1 - Input RF / AC MHz 15A OUTPUT To Local Amplifier / Node RF / AC Mhz 15A INPUT / OUTPUT To / From Remote Amplifier / Node US PATENT 8,415,822 Vin 30-87V Vac (US) Vin 30-64V Vac (EU ) t v t v Vout 87 Vac (US) Vout 60 Vac (EU) Inside view: SYNERGY-2 60/87V -2x15A 11

SYNERGY 2 the New generation. 12 Unlimited backup Power for Optical & HFC networks Without Batteries

US PATENT 8,415,822 NEW UR – Ultra Range +/- 25% Vin a a a a a a 13 a

DOCSIS® & EuroDOCSIS Status Monitoring, Embedded Transponder. Direct RF connection to CATV network Output 2 60,66,72 15A Output 1 60,66,72 15A External Monitoring DPS, SYNERGY-2 & more Dual Port P.S model SC-D-TFPS-1800-E-O-M 2 ports X 15A 60,75,87Vac 50/60 Hz. Direct connection. Voltage testing points Current loop testing points (For Clamp meter) 14

NEW-Dual Port P.S model SC-D-TFPS-1800-EOM 2 ports X 15A 60,75,87Vac 50/60 Hz. 15

Direct RF connection to CATV network Output 2 60,66,72 15A External Monitoring DPS, SYNERGY-2 & more NEW -Dual Port P.S model SC-D-TFPS-1800-UOM 2 ports X 15A 60,75,87Vac 50/60 Hz. Direct connection. Output 1 60,66,72 15A Direct connection. Voltage testing points Current testing points 16 Secondary AC input / Generator Main AC input Phase changer 120 KA SURGE SUPPRESSION DOCSIS® & EuroDOCSIS Status Monitoring, Embedded Transponder.

17 CATV Dual Port P.S 1350VA 15A 60,72,87V Model SC-STFPS EI For hanging or shelf-lain mounting. NEW -Dual Port P.S model SC-D-TFPS UI 2 ports, 15A 60,75,87Vac 50/60 Hz.

SYNERGY-2 Typical configuration Optical node + Trunk amplifier (or second optical node). Power + Signal From Optical node AC 2 input. AC 2 input Local output to local Optical Node. (AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp) Power + Signal Optical Node To remote / amplifier / Node P.S. S P.S 60V Optical Node Or Trunk amplifier 60V Area A Area B 18 Unlimited backup Power for Optical & HFC networks Without Batteries

From Optical node AC 2 input. AC 2 input Local output to local Optical Node. (AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp) Power + Signal To remote / amplifier / Node P.S. S P.S SYNERGY-2 – Demo backup power from Area A to Area B Power + Signal 60V 55V 50V 45V 60V Area A Area B V 60V 40V 19 60V Optical Node Or Trunk amplifier Optical Node Unlimited backup Power for Optical & HFC networks Without Batteries

Power + Signal To Optical node AC 2 input. AC 2 input Local output to local Optical Node.(AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp) Power + Signal From remote amplifier / Node P.S.S P.S 45V 50V 55V 60V SYNERGY-2 – Demo backup power from Area B to Area A P.S Area A Area B 40V 60V 20 Optical Node Or Trunk amplifier Optical Node Unlimited backup Power for Optical & HFC networks Without Batteries

SAFECOM’s powering system around the world. Reliability since

22 Power backup Comparisons Synergy-2 / DPS V4 T-Former GeneratorsNon StandbyStandby + Batteries Power Type Low HighLowHigh Cost Zero PermanentNegligiblePermanent Maintenance Unlimited Limited by fuelNone 2 to 3 hour (Depends on batt. condition ) Backup Power Low cost Very expensiveLowVery Expensive Redundant/ Diversity Optional NON Integrated Surge Suppressor 120K Optional NON Integrated Phase Changer

Typical optical network powering examples 23

90V-network 60V-available 24 Deep Fiber Network 60V- SYNERGY backup power 60V-network 90V-available

60V-network 90V-available 25 HFC Network 90V- DPS5+ Power Booster backup power 90V-network 60V-available

Deep Fiber Network 90V- DPS5+ SYNERGY backup power 90V-network 60V-available 26

Business case. Improving customer service and satisfaction. Enabling MSO to add new services that required top high reliability. Unlimited backup time. Reducing dramatically CAPEX & OPEX. Increasing powering efficacy & save energy. 27

Complete Tree-View Import using CSV files Also can discover One node at a time from the UI (on –demand discovery) Network discovery Export the Tree-View for further Use 1.Discovery can be backed up 2.Automated Full Topology DPS/ SYNERGY back up Auto Discovery of the PS Monitor Supports any device that has an SCTE-HMS-PS-MIB Supports auto discovery of thresholds (SCTE-HMS-COMMON-MIB) Auto Generates Attribute Widgets with properly formatted thresholds Supports all Adjacent devices like APC, Cordex Controllers etc. Supports Discrete Thresholds DOCSIS® & EuroDOCSIS Status Monitoring 28

Monitors the Attributes – Pre-Configured Poll Interval – Summarization (Hourly, Daily) – Graphing (Single or Multiple attributes) – Attribute Refresh (on demand) Monitors the Current Alarm Table – Generates the Events from this table – Auto Correlation (If the alarm is pre-existing, does not generate a new Alarm) – Updates the Tree-view with corresponding Severity – If SNMP Traps are enabled, It will auto-correlate the incoming traps with Current Alarm table 29

Google Maps Integration 30

ON-LINE REPORT 31

 Europe 60V & US 90V Standard.  Support full 15A rms input /output.  Prefect voltage at the remote location in the network.  †† Water-proof Enclosure. (IPX8)  Opposite connection protected.  †† Input & Output Surge Protection.  DOCSIS® & EuroDOCSIS Status Monitoring.  Online RF transmission during operation. (INTERNET, VOD, VOIP) DPSv4 / SYNERGY-2/ Power Booster    32 Standard Features

Summery SAFECOM SYNERGY-2 & DPSv5 & Power Booster offers CATV operators the most efficient and reliable complete backup solution for an unlimited time at minimum cost. No additional cost for MSO further to the fact that SYNERGY-2 / DPS v5 unit can be reused from HFC network to full optical network. Following the government regulation for full powering backup. SYNERGY-2, DPSv5 & Power Booster systems, enabling additional backup from remote powering. No maintenance. Unlimited lifetime. Two way powering on a single cable (Coax or electrical cable) Full DOCSIS® & EuroDOCSIS Status Monitoring 33

Thank you 34