Ken McFarland Pascal Matengo. Lab Overview  Measure flow of water using three different flow meters  Measure flow manually to obtain actual flow rate.

Slides:



Advertisements
Similar presentations
Mass Flow Controller. Function Delivers user specified flow rate of gas. Flow rate is mass flow rate (i.e. number of molecules per sec Mol/sec), not volume.
Advertisements

Fuel On Board Michael Dreher-Byrd - Robert Fulling - Melissa Davis - Matthew Plourde.
1 Comparison of Analog vs. Advance Technology Air Sampling System Designs To Facilitate Correction of Measured or Calculated Volumes to a Set of Reference.
Heat Conduction of Zinc Specimen Femlab Simulation Measurement Calibration Technique: Effects of Heat Loss Through Specimen Surface Area.
Thermo-energy audit Services for thermo-energy audit Flow measurement.
Overview Discuss Test 1 Review RC Circuits
PH pH is a unit of measure which describes the degree of acidity or alkalinity (basic) of a solution. It is measured on a scale of 0 to 14. The formal.
Data Acquisition Risanuri Hidayat.
Experiment (4) Flow Measurement
Lindab Pascal - Simplified VAV solution with full potential...
FSTS “water hammer” Running mode Pressure profile of the “water hammer” pulse – Joukowsky Equation FSTS Running worst case scenario : – instant closing.
Center of Mass Lab A.Solid Right Triangle 1. Construct a solid right triangle from a piece of cardboard with a known base and height. 2. Calculate the.
Greg Hyde Raymond Zheng Joseph Rojano Katie Bentley Lori Liebman P14414 P3 ARBORLOO WIND RESISTANCE TEST STAND DETAILED DESIGN REVIEW 1.
ENTC-303Dr. Alvarado1 Flow Measuring Devices. ENTC-303Dr. Alvarado2 Flowmeters Devices used to measure flow rate: –Venturi (based on pressure difference)
Feed and Reboiler Pump Analysis ENCH 435 September 25 th, 2007 Jason Frizzell.
Level Sensors.
Flow Measurement M. Shahini.
Chapter Five Flow Measurement
ACADs (08-006) Covered Keywords Flow rate, total flow, differential pressure, percent flow, cotameter, Bernouli. Description Supporting Material
Hydrology and Water Resources RG744 Institute of Space Technology December 11, 2013.
Energy Audit- a small introduction A presentation by Pune Power Development Pvt. Ltd.
EXPERIMENTAL CLASS 3. FLOW MEASUREMENT
FDR Presentation Personal Health Monitoring Device Bassam Noaman Dina El-Eissa Mentor: Prof Zhenyu Guo Instructor: Prof J Silverman 4/12/00.
Interfacing Physics Sensors Using National Instruments Educational Laboratory Virtual Instrumentation Suite & LabVIEW by Eric Ethridge Left to right: motion.
Abstract There are many applications today that require a means of controlling a particular setting given an ever changing environment without human intervention.
Introduction What is a sonic orifice? How does it work? What are its uses? How is it applicable to lasers?
Data Acquisition Overview 1 Using LabVIEW to acquire, analyze and record data.
Figure 6 Voltage transient curve In fig.6, it is obvious that there is a significant voltage drop and transient at 1400s even though the load is not changed.
Measurement of flowing fluids
CHAPTER 5: PRESSURE 5.1 Pressure and Its Units
Discharge (Q) Define (cfs; m 3 /s or “cumecs”) Why is Q Important? How is it measured?
Unit 07 “Work, Power, Energy and Energy Conservation” Lab Predicting the Final Velocity of a Car Using the Conservation of Mechanical Energy.
Work on an Incline Lab (name and period).
Digital Electronics and Computer Interfacing
Artificial Neural Network Approach to Temperature Control Presented by Jeff Boettcher.
Robot sensors MVRT 2010 – 2011 season. Analog versus Digital Analog Goes from 0 to 254 Numerous values Similar to making waves because there are not sudden.
FINDING THE HEIGHT OF A CONE 15 Minute Math Labs.
Thursday Lab Projects ELCT 201 Spring 2011 Laser Light Show Water Test Stand Automation MSD Automated Demonstration.
Problem Transient Response By: Matt Lausmann ME 114 Granda Assignment #3.
An Overview of LabVIEW by: The Software User-Interface Group!
1 ATF2 Q BPM electronics Specification (Y. Honda, ) Design System –Hardware layout –Software –Calibration Testing Production schedule ATF2 electronics.
Notes 11-1 Pressure. What Is Pressure? The amount of pressure you exert depends on the area over which you exert a force.
PID. The proportional term produces an output value that is proportional to the current error value. Kp, called the proportional gain constant.
Experiment 17 Two Differentiators Circuit. Analog Computing Analog computers – First were mechanical systems. Electrical analog computers were developed.
The Percent Proportion. To solve a proportion, multiply the numbers that are diagonal, divide by the one that’s left.
Applied Hydrology RSLAB-NTU Lab for Remote Sensing Hydrology and Spatial Modeling 1 Streamflow Measurement and Calculation Professor Ke-Sheng Cheng Dept.
P16452 Active Reciprocating Compressor Valve Assembly Team: Negar Salehi, Bob Osborn, Ian Nanney, Keith Leung, Chris Reynolds.
A Wearable Power Generator for Sports Monitoring Applications by Ursula Leonard th Sports and Exercise Engineering Final Year Project Supervisor:
C A microfluidic device was created in order to mix the contents of two reservoirs through a 200um-wide, 30mm-long diffusion channel. Flow Characterization.
The Scientific Method Applied to an Ecological Problem.
Hydrology and Water Resources RG744 Institute of Space Technology November 13, 2015.
GOVERNMENT ENGINEERING COLLEGE, BHARUCH (014) Chemical Engineering department SEM-iii Sub: fluid flow operation topic: orifice meter & rotAmeter Guid by:
Gas Flow Meter Client: John Webster Advisor: Naomi Chesler Project Leader: Anna Moeller Communications: Kailey Feyereisen BSAC: Ryan Drake BWIG: Gina Stuessy.
Experiment #1: Centrifugal Pumps Alberto J.Pérez #79737.
Byong Guk Jeon, Ho Sik Kim NQe 401 Exp. 3 Flow measurement.
Phil. U., M Eng Dep., Measurements, Chap#7 flow measurements is very important as it covers wide ranges of applications. The flow rate measurement devices.
G.H.PATEL COLLEGE OF ENGINEERING AND TECHNOLOGY
Compressible Flow in Nozzles Thermal Engineering Lab ME-4111 Professor: Eduardo Cabrera Damian Luna Yetziel Sandoval – Alberto Gonzales –
1 Chapter No. 9 Measurements and Detection of Radiation, Nicholas Tsolfanadis, 2010, McGRAW-HILL BOOK INTRODUCTION TO SPECTROSCOPY.
UNDERSTANDING DIFFERENT
Workshop JRA1- INFN Legnaro, 19/2005
Process Variables, Elements and Instruments – Flow - Agenda
GOVERNMENT ENGINEERING COLLEGE, BHARUCH.
PREAPRED BY : SAKARVADIYA JAY
S. Ghosh, M. Muste, M. Marquardt, F. Stern
Undulator Assembly Procedure
Active Reciprocating Compressor Valve Assembly P16452
VISUAL AIDS for instruction in VACUUM TECHNOLOGY AND APPLICATIONS
CHROMATOGRAPHY.
Presentation transcript:

Ken McFarland Pascal Matengo

Lab Overview  Measure flow of water using three different flow meters  Measure flow manually to obtain actual flow rate  Use known flow rates and meter reading to construct calibration curves for each meter

Lab Purpose  Gain experience with calibration curves  Familiarization with flow meters  Gain additional experience with LabView

Rotameter  Simplest type  Operator read  Height of bob corresponds to rate of flow  Height * Constant = Flow Rate  Our constant was C ’ m =113

Orifice Plate  Constricts flow to create pressure differential between two sides of plate  Pressure differential is proportional to flow rate  Create calibration curve as with Rotameter

Magnetic Flow Meter  Most sophisticated meter  Easily computer monitored  Displays flow rate as a percent of the maximum measureable flow rate  Percent is displayed visually on the meter, and as a voltage that is monitored via computer

Magnetic Flow Meter VI  Top is raw voltage  VI takes voltage from meter and multiplies it by conversion factor  Final output is flow rate in kg/s  Bottom is final VI  Max flow rate was 2.11 kg/s

Conclusions Recommendations  This lab demonstrated how to use Rotameter and Magnetic flow rate meters  Found constants to relate meter readings to flow rates  Learned to create calibration curves  Read the lab beforehand  Think about how to do lab  Teamwork  Insure all meters are working correctly