EE4503 Electrical Systems Design

Slides:



Advertisements
Similar presentations
Bonding and Grounding What? Why? How?
Advertisements

Grounding Electrodes.
The Electrical GuruTM Paul W. Abernathy,CME
Earth Ground Resistance The Basics
Stray Current Investigations A Method of Troubleshooting Stray Current on Underground Residential Distribution (URD) Loops Stacey Mighty Malcolm Distribution.
Telecom Cabling Grounding and bonding.
ASSIGNMENT TEACHER Smt. K.VASUMATHY GROUP MEMBERS:- MANSI DWIVEDI (ET 4 TH SEM) ARTI DWIVEDI (ET 4 TH SEM) DIKSHA CHANDRAKAR (ET 4 TH SEM) MAMTA CHOUDHARY.
Electrical Safety and Grounding Essentials Copyright © Texas Education Agency, All rights reserved.
FIRE PUMP ELECTRICAL CONFIGURATIONS UNDER 600 VOLTS.
EE4503 Electrical Systems Design
Guide to Network Cabling Fundamentals
AC Mitigation Overview
EET Survey of Electronics
“Equipment bonding jumpers: are they always necessary?” Massimo Mitolo, Senior Member, IEEE.
Electrical Power Systems
EE4503 Electrical Systems Design
EE4503 Electrical Systems Design
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE PV APPLICATIONS CODES AND STANDARDS EMERGENCY RESPONSE.
Bonding, Grounding and the NEC  Presented by The National Association of Certified Home Inspectors
Electrical Earthing D.K.Pathirana. Applications of earthing Protect human against lightning and earth fault condition Protect the premises against lightning.
UMKC Senior SUBSTATION DESIGN TEAM
1 EXPERIENCE AND RELIABILITY. 2 Short circuit loop measurements EN EN
Copyright 2005 Ted "Smitty" Smith Two Minute Drill Number Three Improving your skill in code Look Up Increasing Speed Drill.
Protection against Electric Shock (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation.
Electrical Principles and Wiring Materials. Principles of Electricity n Electricity is a form of energy that can produce light, heat, magnetism, chemical.
IEEE Wind Farm Collector System Grounding for Personal Safety Summary of Topics.
Grounding, bonding, and ground fault currents
Earthing configurations Minute Lectures Earthing or not? Is that the question? It is often thought that an electrical appliance can only be earthed or.
CHAPTER 6 EARTHING SYSTEM.
Wiring and Grounding.
Gandhinagar Institute of Technology
Assumption University Thailand EE4503 Electrical Systems Design Main Circuit 1.
Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith Two Minute Drill Number 24- Residential.
Outdoor Installation 2: Lightning Protection and Grounding Training materials for wireless trainers.
Assumption University Thailand EE4503 Electrical Systems Design Short-circuit Current 1.
Concrete encased electrode Main 20’ NEC “Equipment Grounding Conductors, grounding electrode conductors and bonding jumpers shall be connected.
Ag. Mechanics for Beginning Teachers
132KV GSS PIPAR CITY JODHPUR
Testing of Low Voltage Installations
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
Starting Residential Wiring.  The most important element in wiring. Safety is proper grounding.  Grounding is the connection of all parts of a wiring.
ELECTRICAL EARTHING.
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
HOUSE WIRING NOTES. Electricity  Proton – positive charge  Electron – Negative charge  Electricity = flow of electrons Conductor= electricity passes.
Grounding the Electrical System Reference: AAVIM “Electrical Wiring” Created May 2007.
A+ Computer Repair Lesson 4 Introduction to Electricity and Safety.
N.E.C. Installation Techniques and Common Violations
Unit 231 Grounding Bonding Overcurrent Protection.
UNIT-5. ELECTRICAL SAFETY, WIRING & INTRODUCTION TO POWER SYSTEM
Grounding the Electrical System
License Examination Practice Drill
Grounding the Electrical System
ELECTRIC SHOCK AND EARTHING
EARTHING.
POWER QUALITY AND MANAGEMENT. TITLE : EARTH GROUND GRID SYSTEM AND POWER GROUND SYSTEM. PREPARED BY : JOBIN ABRAHAM.
Practice Code Look Up Two Minute Drill #7
Conductors and Cables 2017 NEC
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Govt. Polytechnic,Manesar
Mains Plug Wiring: Brown lead Live Blue Lead Neutral
Overcurrent Protection— Fuses and Circuit Breakers
EET 323 – Electrical System Design Lecture 9: Grounding
Contactor A contactor is an electrically controlled switch (relay) used for switching an electrical power circuit. A contactor is typically controlled.
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Safety Meeting Topics Standby Generator Safety
Smitty’s Two Minute Drill Grounding and Bonding
Protecting Your Shack From Lightning (as best you can)
Grounding Myths.
Presentation transcript:

EE4503 Electrical Systems Design Grounding

Topics Introduction to Grounding Grounding of Electrical Systems Grounding Systems Grounding Resistant

Grounding Grounding or Earthing Make the potential difference become the same as ground/earth. For human safety and equipment safety Follow NEC Article 250

Grounding Category System Grounding: connect the “live” portion of the electrical system to ground, e.g. neutral Equipment Grounding: connect a part (having no current) of the equipment to ground, e.g. case live = having current

Grounding Components Grounding Electrode (System) Grounding Electrode Conductor Grounded Conductor Main Bonding Jumper Equipment Grounding Conductor

Electrical Systems Design: ประสิทธิ์ พิทยพัฒน์ Grounding Components Electrical Systems Design: ประสิทธิ์ พิทยพัฒน์

Grounding Components http://cr4.globalspec.com/thread/40145/Grounded-Neutral

Grounding Common Grounding Systems System Grounding Service Equipment Grounding Separately Derived System Equipment Grounding Computer Grounding

Grounding AC System Grounding “live” portions of the electrical system Protect Overvoltage: specially from lightning Stabilize voltage level referring to ground Be part of protection circuit: be part of the short- circuit current 50V, 50 to 1kV, more than 1kV

Grounding AC System Grounding – 50V NEC Standard The source is stepped down from more than 150V is stepped down from the ungrounded system Cable in over the ground outside the building

Grounding AC System Grounding – 50 to 1kV Usually at the distributed transformer Neutral is grounded

Grounding AC System Grounding – Electrode Grounding Electrode Conductor Connected to three parts Grounded Conductor: usually neutral line Equipment Grounding Conductor Main Bonding Jumper

Grounding AC System Grounding – Electrode Cable: continuous copper cable with insulator Installation: connect to a surface, recommend conduit EMC: metal component needed to be connect to ground

Grounding AC System Grounding – Electrode Cable: continuous copper cable with insulator Installation: connect to a surface, conduit (recommended) EMC: metal component needed to be connect to ground Connection: Exothermic Welding, or other recommended methods

Grounding AC System Grounding – Exothermic Welding http://www.youtube.com/watch?v=CqixbTQG13M

Grounding AC System Grounding – Cable Size http://www.kroo-suchat.com/File_data/ground.pdf

Grounding AC System Grounding – Cable Size Meter (A)  MCB (A) Cable Sizing (sq.mm.) Voltage (V) Incoming Cable in Air (Grounding) Incoming Cable in Conduit (Grounding) 5 (15) 1 16 4 (10) 4,10**(10) 300 15 (45) 50 10 (10) 16 (10) 30 (100) 100 25 (10) 50 (16) 50 (150) 125 35 (10) 70 (25) 3 750 200 250 95 (25) 150 (35) 400 500 240 (50) 500 (70) http://irrigation.rid.go.th/rid17/Myweb/machanical/type%20lamp.html

Grounding Service Equipment Grounding Usually two points of grounding: at the transformer and at the main distribution box “Main Bonding Jumper” connects the metal part of the main distribution box to ground “Main Bonding Jumper” (now) connects to the grounded conductor Same calculation as “System Grounding”

Grounding Separately Derived System Electrical systems that are separated inside the facility (after the utility): e.g. from utility and generator Common Neutral: grounded only at the main distribution box Isolated Neutral: grounded separately and have the isolated ground rod

Grounding Equipment Grounding Grounding for the “non-live” metal portion The enclosure has the same potential level as the ground (protected for human contact) Improve short-circuit protection: conductor touching enclosure Path for the leakage current

Grounding Equipment Grounding – What to be grounded? Metal enclosure & Protected Fence: metal conduit, panelboard enclosure, electric crane, elevator’s enclosure Protected fence: HV station Electrical Appliance specially with outlet: more than 150V, except having proper insulator (e.g. double insulator)

Grounding Equipment Grounding – What to be grounded? Fixed Equipment with hard wires specially able to be touched Close contact to human: grounded within 2.4m from ground and 1.5m from wall Electrical contact to metal Wet area

Grounding Equipment Grounding – Effective Grounding Continuity Low Impedance High Ampacity Copper: with or without insulator Busware: that specified for grounding Metal Armor of some cables: AC, MI, MC

Grounding Equipment Grounding – Effective Grounding http://www.iaei.org/magazine/2006/09/new-form-of-mc-cable-crosses-application-boundaries/

Grounding Equipment Grounding – Sizing Tables (if common ground cable, take maximum one) In general: according to rating of CB For motor: according to the rating of overload protection. http://www.cable.alcan.com/NR/rdonlyres/19FC4111-742D-47B7-9A28-06DF8AB4023D/0/EquipmentGroundingConductor.pdf

Grounding Equipment Grounding – Sizing Rated Circuit Breaker or Overload Protector (A) Ground Cable Size (mm2) 16 1.5 (recommended 2.5) 20 2.5 40 4 70 6 100 10 200 400 25 500 35 Electrical Systems Design: ประสิทธิ์ พิทยพัฒน์

Grounding Computer Grounding Power Distribution Grounding Single Ground Point to protect “Ground Loop” High Frequency Grounding in the order of kHz or MHz 60cm x 60cm conductor grid Recommend common ground electrode

Grounding Electrode System Earth Refered as 0 Deeper in the ground (more humidity)  lower resistance Good for make the reference voltage as 0 ** not capable enough to conduct high current

Grounding Electrode System Electrode Existing Electrode Underground metal pipes Building structures Pile Under ground metal structures Made Electrode Ground Rods Concrete Encased Electrode Buried Plate Ring Grid

Grounding Electrode System Ground Rod Copper rod with at least 16mm in diameter and 2.4 m in length Few longer rods are better than many short rods

Earthing Scheme 2,3 or 4 characters 1st: relation between distribution system and earth T means single point connecting to earth I means isolated from earth

Earthing Scheme 2nd: relation exposed conductive part and earth T means no connection to the electrical system N means there is a connection between the exposed conductive and electrical system (neutral)

Earthing Scheme 3rd(if any): arrangement of neutral (N) and protective conductor (PE) S means separation between N & PE C means common between N & PE

Type of Earthing System IT http://www.electrical-installation.org/enw/images/5/5e/EIG_chap_E-2010_1.pdf

Type of Earthing System TT http://www.electrical-installation.org/enw/images/5/5e/EIG_chap_E-2010_1.pdf

Type of Earthing System TN-C http://www.electrical-installation.org/enw/images/5/5e/EIG_chap_E-2010_1.pdf

Type of Earthing System TN-S http://www.electrical-installation.org/enw/images/5/5e/EIG_chap_E-2010_1.pdf

Type of Earthing System TN-C-S http://www.electrical-installation.org/enw/images/5/5e/EIG_chap_E-2010_1.pdf

Resistance to Ground By E.I.T. standard 5 Ohm Some area, authority might allow up to 25 Ohm If cannot achieve, try adding extra electode

Reference Electrical Systems Design: ประสิทธิ์ พิทยพัฒน์ Depend on the area, end-user can connect to the “meter” of the authority in three ways.