1. 2 Spare part stockCalibration room Headquarters Goteborg, Sweden, founded 1979 Sensor development Manufacture & assembly Marketing and Sales Service.

Slides:



Advertisements
Similar presentations
ULTRASONIC WATER AND FLOW METERS
Advertisements

Laser Speckle Extensometer ME 53
New Non-Contact, Laser-Based Gauge for Measuring Length and Speed of Gypsum Board Stuart Manser Beta LaserMike.
Enhanced Easy-Stop TM Trailer ABS Sales. Enhanced Easy-Stop Trailer ABS System configurations to meet any air-braked trailer application 2S / 1M, 2S /
Rotary Encoder. Wikipedia- Definition  A rotary encoder, also called a shaft encoder, is an electro- mechanical device that converts the angular position.
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
Introducing Profile360 for Pipe OD, OOR, and Length Measurement.
Market introduction CellaTemp PA.  Newest interface technology  Latest high-resolution microprocessors  Newest sensors  New amplifier technology 
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
Spare part stockCalibration room Headquarters Goteborg, Sweden, founded 1979 Sensor development Manufacture & assembly Marketing and Sales Service.
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
Data Logger for Water Meter Function Continuously counts pulses from pulse output of the water meter (or other meters with pulse output) and periodically.
CheckSystem 2.1 Portable Test Systems Page 1 April 2011.
The Interface Solution Experts Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2) Up to 32 Channels.
 The new generation of microwave detectors. Umirs Europe Kft.  Umirs Europe is a Hungarian-Russian firm developing and manufacturing professional perimeter.
A* candidate for the power supply Wiener MPOD-LV crate w/ remote control only (except for local on/off switch) Type “EC LV” Front or rear connections (reverse.
BAR CODE SCANNER A.ANUSHA (06N61A0402). What is bar code? A barcode is a machine readable representation of information. Barcode stores data in widths.
System Elements HighPoint Broadband Delivery System Sector 1 Sector 3
01/2008©Copyright 2008 Desco Industries Inc / Critical Environment Ioniser cm CE Ioniser, 220V / cm CE Ioniser, 220V.
S80 Laser Distance Sensors
6.5” wide Monitor for Navigation & Video Application !
PPS 3.3 C Portable Power Source Page 1 January 2011.
Data Communications Introduction and Review. Transmission Media Copper Wires Copper Wires Low resistance. Electrical signal produces miniature radio station.
BioWin ®. Bio Gas – The alternative energy source of the future! BioWin ® - Bio Gas Analysis of the future!
Smart transmitters.
Laser Triangulation Displacement Sensor
ENERGY of 21 st Century Independent Power Supplies.
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
High Sensitivity Smoke Detection
Aquatic Spectrometer & Turbidity Meter Preliminary Design Review ECE 4007 L1, Group 8 Paul Johnson Daniel Lundy John Reese Asad Hashim.
ESA EJSM/JGO Radio & Plasma Wave Instrument (RPWI) Warsaw meeting Lennart Åhlén.
Case Study Computer Controlled Radiation Monitoring System
Made in United States of America ZVM Solo EMIT ZVM Solo the most complete monitoring solution on the market.
MICE RF System Power Supplies, Control and Monitoring Status report February 2012 Chris White, STFC Daresbury Laboratory MICE Collaboration Meeting CM32,
ATLAS ATLAS DCS B.Hallgren, CERN EP/ ATI PRR CERN 4 March the Embedded Local Monitor Board ELMB Design description of the Embedded Local Monitor.
High Speed 3D Imaging Technology
Serial Transmission System Series EX510 BackgroundFeaturesTechnical detailsApplications.
PF3W Series 3-Color Display Digital Flow Switch Planned release date: May 2012.
World Leaders in Combustion Management Solutions Module Gas Setup Introduction The Mk7 E.G.A Cell Status Further Information.
Invensys Controls Europe An Invensys Company EWCM 41x0 family New 32x74.
Hardware Introduction – Standard vs Q.i
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
“ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise.
Ionizer IZS31 Series. 1. Features (1) Following functions are added to the current IZS30 on sale. Detects the dirt on the electrode needle. Detects the.
12 September 2006Silicon Strip Detector Readout Module J. Hoffmann SIDEREM SIlicon Strip DEtector REadout Module.
PSD upgrade: concept and plans - Why the PSD upgrade is necessary? - Concept of the PSD temperature stabilization and control - Upgrade of HV control system.
CTA Calibration Meeting 1 The ASTRI SST-2M Illuminator A.Segreto, G. La Rosa INAF Palermo for the ASTRI Collaboration & the CTA Consortium A. Segreto/G.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
아이알브이테크 1 IRV-TECH 아이알브이테크 May 12, 2015 IRV-65B Light Source.
Serial / Ethernet Converter - IE-CS-2TX-XRS232/485
LOGO Electronic Volume Converter TZ, PTZ ”Flougas-T”
Linescanner MP150 Infrared Temperature Measurement for Quality Control and Process Automation Raytek Confidential 10/2010, Rev. B.
Fan Assembly Driven by Magnetic Fields
Product Overview Analogue Input, 2fold, SM  Box  Sensor connections
PTS 3.3 C Portable Test System.
TORQUE MEASURMENT.
Introducing Profile360 for Pipe OD, OOR, and Length Measurement
Analog Room Command Module
Introducing QUANTiC™ series encoders
Nematron® EnduraTouch II 17” Enclosed Computer Launch
Moving your Control Forward - VFD from Unitronics
Nematron® EnduraTouch II 17” Enclosed Computer Launch
Vibration Monitoring System M14
MicroHAWK Long Range – Launch Presentation
Moving your Control Forward - VFD from Unitronics
Dispersive Comb-Spectrum Interferometer: Metrological Characterization
Series 5300 Lithium Cell Formation System
DeviceNet Communication Solution for Discrete Devices
Automatic operation IR rework system Automatic Component placement 2 x K-type thermocouples IR-pyro sensor RPC-camera.
Presentation transcript:

1

2 Spare part stockCalibration room Headquarters Goteborg, Sweden, founded 1979 Sensor development Manufacture & assembly Marketing and Sales Service

Global organisation Headquarters in Gothenburg. -Management -Development -Production -Service NA office in Charlotte, NC -Sales -Service Offices in the UK, Germany and Finland.

PreciCura SR/MR/LR

MR= Measurement Range SO= Stand-Off distance CE= SO=Xmin=Close End Sensor output=MR FE= SO+MR=Xmax=Far End Sensor output=0 CE Xmin FE Xmax Definitions

Technical specifications: Measurement Range (MR):100 … 8000 mm CCD array: 2000 pixels. Resolution: MR / (16 x sub-pixel) Power supply: +24 VDC (18-32 VDC) Diode laser: 1 to 20 mW Laser class: 2, 2M, 3R or 3B Wave length: nm Measuring frequency: 2000 Hz Working temperature: 0 – 40  C PreciCura SRPreciCura MRPreciCura LR 162 x 108 x 42 mm303 x 149 x 57 mm524 x 149 x 57 mm 1,0 kg3,0 kg5,0 kg The PreciCura family

Serial RS232 HOST (MR/LR only) up to bit/s ASCII - FORMATS CAN-bus Field bus system up to 1 Mbit/s (Bus length 40 m) up to 250 Kbit/s (Bus length 200 m) Real time bus system to combine with PLC, Encoder… Analog 16 bit 0…20 mA or 4…20 mA C1: serial RS232 service interface C2: Main connector, Power supply CAN-bus and Analog interface C3: Serial RS232 HOST interface and sensor synchronization Interfaces

Delivery includes: - Manual in English - 2 meter cable for the C2 connector - Serial RS232 interface for setup and service - CAN-bus and Analog (0 or 4 to 20 mA) interface PreciCura SR

Options: 3-point bracket:Mounting bracket for easy fine adjustment of the sensor. PreciCuraSet:Windows® based setup software. Incl. 5 meter cable to PC. Air knife:For compressed air. Blower unit:Front mounted. For fan driven air. Calibration fixture:Rotating calibration target on an arm. Ideal for thickness calibration. Cooling box (Air):Protective enclosure with fan driven air cooling connection.

Delivery includes: - Manual in English - 2 meter cable for the C2 connector - Serial RS232 interface for setup and service - CAN-bus, Analog (0 or 4 to 20 mA) and serial RS232 HOST interface PreciCura MR

Options: Measurement Range:100 < MR < 2000 mm, resolution 0,01 or 0,1 mm depending on MR Mounting bracket:Mounting bracket for easy fine adjustment of the sensor. PreciCuraSet:Windows® based setup software. Incl. 5 meter cable to PC. Air knife:For compressed air. Blower unit:Front mounted. For fan driven air. Cooling box (Air):Protective enclosure with fan driven air cooling connection.

Delivery includes: - Manual in English - 2 meter cable for the C2 connector - Serial RS232 interface for setup and service - CAN-bus, Analog (0 or 4 to 20 mA) and serial RS232 HOST interface PreciCura LR

Options: Measurement Range:600 < MR < 8000 mm, resolution 0,1 or 1 mm depending on MR Mounting bracket:Mounting bracket for easy fine adjustment of the sensor. PreciCuraSet:Windows® based setup software. Incl. 5 meter cable to PC. Air knife:For compressed air. Blower unit:Front mounted. For fan driven air. Cooling box (Air):Protective enclosure with fan driven air cooling connection.

Protection and cooling box Brackets Calibration unitBig display PreciCuraSet Accessories

- Rugged, industrial design - No moving parts - Not sensitive for colour variations - Center-of-Gravity evaluation of measured distance and 16-times subpixel => increased resolution and accuracy - CCD evaluation of distance => less sensitive for dirt on the front glasses, secondary reflections and background radiation - No extra control unit Benefits

Target: rotating white paper Target: white paper, not moving Speckle effect

Filter algorithms: AverageFilter length: (Filter length = 1 => No filter). Data output rate is reduced proportional to the Filter length. Moving AverageFilter length: (Filter length = 1 => No filter). Data output rate is NOT reduced by the Filter length. MedianSorting the content of the data buffer. Normally uses the middle value of the buffer as output. Can also be used as a min/max filter. Eliminates spikes in the data. Filters

Control of data input to the filter: - ContinuousFixed filter length (settable between ). - TrigThe filter length is controlled by the leading (positive) flanks of the trigger input. - GateThe filter length is controlled by the leading and trailing flanks of one trig pulse. - Self trigThe Filter length is controlled by the internal error messages in the sensor (Valid data/”NO OBJECT”) i.e. the measurement target controls the filter length. (e.g. in thickness measurement applications of a board).

Upper PreciCura Lower PreciCura CAN-bus Conn. box Upper PreciCura: Measuring mode:Distance CAN bus ID:101 Filter type:Averaging Filter Length:1 Synchronization mode:Slave (option) Lower PreciCura: Measuring mode:Thickness CAN bus ID:100 Filter type:According to application Filter Length:According to application Synchronization mode:Master (option) Outputs available:CAN-bus, Analog, Serial RS232 Thickness measurement Power CANbus (Synch) Power Output

Thank you