Wiring Design and Protection Including Ground Fault Circuit Interrupters.

Slides:



Advertisements
Similar presentations
Introducing Electricity and Electrical Safety
Advertisements

Introducing Electricity and Electrical Safety
2014 NEC Code Changes Ted “Smitty” Smith E Light Electric.
CHEM 521 Safety Presentation. Hazard Symbols You Must Know.
OSHA Office of Training and Education
Young Worker Safety Resource Center, adapted from OSHA Office of Training and Education Electrical Safety.
Master Examination Practice Drill # Ted “Smitty” Smith.
Proper Use of Extension Cords Proper Use and Electrical Hazard Awareness for Extension Cord Users Module 2.
Topic 2 Reading Blueprints and Drawings SCO 2.14.
OSHA Office of Training and Education
 Recognize the scope and structure of the OSHA standards.  Identify the common electrical hazards in long term care settings.  Discuss electrical safety.
For The Poultry Industry
Electrical Power Systems
Occupational Safety and Health Course for Healthcare Professionals.
Electrical Principles and Wiring Materials
Union College EHS Training 1 Electrical. 2 Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical.
Why Construction Workers are Getting Electrocuted Michael McCann, PhD, CIH Director of Safety and Ergonomics The Center to Protect Workers’ Rights
Hazard - Inadequate Wiring
Master Examination Practice Drill # (16) O 1. In commercial and industrial establishments, all 15- and 20- ampere, single-phase, 125 volt receptacles.
Electrical Safety - Construction. Electricity - The Dangers About 5 workers are electrocuted every week Causes 12% of young worker workplace deaths Takes.
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
By Carlin Bright. Electricity The flow of electrons in a conductor.
Sub Part K Electrical - Installation Safety Requirements (a) Covered. Sections through contain installation safety requirements for.
Purpose Power lines Equipment Assured Grounding GFCI Conclusion.
BUILDING TRADE SAFETY ELECTRICAL SAFETY.
ELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S
Subpart K Electrical 29 CFR
Electrical Principles and Wiring Materials. OBJECTIVES 1. AM16.01 Define common electrical terms. 2. AM16.02 Compute electrical energy use and cost. 3.
Electrical Safety INSTRUCTOR’S NOTES:
Hazard Identification at Home. Ground Fault Circuit Interrupters (GFCI’s)  GFCI’s provide protection by turning off the power before a shock occurs 
Electrical This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are.
Electrical Safety INSTRUCTOR’S NOTES:
ELECTRICAL HAZARDS Electricity is an essential of modern life Some work directly with electricity (Engineers, circuit assemblers) Some work indirectly.
Electrical Principles and Wiring Materials. Principles of Electricity n Electricity is a form of energy that can produce light, heat, magnetism, chemical.
Equipment Use In Occupancies  A receptacle shall not be grouped or ganged in enclosures with other receptacles unless they are so arranged so that voltage.
Electrical Safety INSTRUCTOR’S NOTES:
All Colby employees work with and around electricity on a daily basis. This Safety Talk focuses on the basic electrical safety elements to protect you.
Electrical Safety in Construction. Objectives In this course, we will discuss the following: Common electrical hazards Standards relating to those hazards.
Basic Electrical Safety
1 Electrical. 2 Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:  Electrocution.
©Ted “Smitty” Smith This speed drill focuses on subjects that will be required for the journeyman and masters examination arranged by chapter of.
For The Food Processing Industry. Overview This presentation discusses some of the key issues related to safety for the poultry processing industry and.
MAGM 225 Mr. Conrado Ground-Fault Circuit Interrupters.
Proper Use of Extension Cords
Tulane University - Office of Environmental Health & Safety (OEHS) Electrical Safety For Office, Facility, and Laboratory Employees Tulane University October.
Electrical Plans.
Electrical Safety Craig Shurson CSP, ARM Regional Loss Control Coordinator Hortica - The Florists Mutual Company.
1 Electrical Safety This material was produced under grant number SH F-18 from the Occupational Safety and Health Administration, U.S. Department.
For The Poultry Industry. Disclaimer This module was developed for the poultry industry. The presentation is not inclusive of all of the safety related.
Ag. Mechanics for Beginning Teachers
Copyright 2008 Ted "Smitty" Smith Two Minute Drill Number 21- Residential Improving your skill in code Look Up Increasing Speed Drill.
By: Mr. Brock.  Electricity- Source of energy that can be easily converted into light, heat or power  Ampere (Amp)- Unit of measure of the rate of flow.
1 Electricity. This material was produced under grant number SH F-54 from the Occupational Safety and Health Administration, U.S. Department.
Residential Wiring Unit 3 – Installation and Planning.
ELECTRICAL WIRING WIRING BASICS Written by Bobby Joslin
Residential Wiring Unit 3 – Installation and Planning Chaps 9-12.
Tulane University - Office of Environmental Health & Safety (OEHS) Electrical Safety For Office, Facility, and Laboratory Employees Tulane University May.
Principles of Electricity Volt The measurement of electrical pressure.
ELECTRICAL SAFETY in the Lab. 1.Electricity takes the path of least resistance. 2.Electricity wants to go to ground. 3.If an electrical appliance or tool.
Electrical Safety OSHE 382, Spring 2016
Planning The Electrical System
Surviving the OSHA Audit!
2014 NEC – Code Changes Pertaining to Wiring Devices
HOME ELECTRICAL SAFETY
Practice Code Look Up Two Minute Drill #7
Electrical Safety Review Compliance Assistance Region IV
Calculations: Transformers and Service Conductor Calculations
Conductor A material, such as copper, that permits the flow of electricity; usually refers to the a wire.
Wiring Circuits Lesson Plan PSTS: C6-7.
Objectives Finish with Practice circuits problems for
Presentation transcript:

Wiring Design and Protection Including Ground Fault Circuit Interrupters

This material was produced under grant number SH F-12 from the Occupational Safety and Health Administration, U.S. Department of Labor. It does not necessarily reflect the views or policies of the U.S. Department of Labor, nor does mention of trade names, commercial products, or organizations imply endorsement by the U.S. Government. This material was produced by the Workplace Safety Awareness Council, a 501(c)(3) not-for-profit organization dedicated to safety in the workplace. For further information about the council or upcoming safety related training, please visit our website at or call us at (863) Introduction

Ground-Fault Circuit Interrupter This device protects you from dangerous shock If a ground fault is detected, the GFCI can shut off electricity flow in as little as 1/40 of a second, protecting you from a dangerous shock

Ground Fault Receptacles (b)(3)(i) & (b)(3)(ii)(A) GFCI are required: in bathrooms on rooftops temp wiring for maintenance, remodeling or repair extension cords if used for temp. electric power receptacles used for equipment in damp or wet locations

Outlet devices Outlets shall not be rated for less than the circuit load

Separation of Overhead Lines & Pedestrians Installations on or after August 13, ’ Clearance – less than 150V to ground Examples include: Finished grade Side walks Clearance for Overhead Lines (c)(2) - Table S-6

Clearance for Overhead Lines (c)(2) - Table S-6 Separation of Overhead Lines & Vehicles / Equipment Installations on or after August 13, ’ Clearance – less than 300V to ground Examples include:  Residential property and driveways  Commercial area subject to vehicular traffic other than truck

Clearance for Overhead Lines (c)(2) - Table S-6 Separation of Overhead Lines & Vehicles / Equipment Installations on or after August 13, ’ Clearance – 301V – 600V to ground Examples include:  Residential property and driveways  Commercial area subject to vehicular traffic other than truck

Clearance for Overhead Lines (c)(2) - Table S-6 Separation of Overhead Lines & Vehicles / Equipment Installations on or after August 13, ’ Clearance – Less than 600V to ground Examples include:  Public streets, alleys, roads and driveways  Commercial area subject truck traffic  Other land traversed by vehicles (i.e. cultivating, forests)

3’ from windows, doors, porches, fire escapes, balconies etc. Service conductors may not be below openings through which materials may be moved Clearance From Building Openings (c)(3)(i)

Overcurrent protection: Readily accessible to building management personnel Not be located where they could be damaged Breakers clearly indicate whether on or off If operated vertically up position is on C.B. shall be marked SWD if used as switches  C.B. rated 120/240 used only on 120/240 circuit panels  C.B. rated 277/480 used only on 277/480 circuit panels Overcurrent Protection (f)(1)(iv) – (ix)

Ranges, ovens, counter cooking units, clothes dryers if within 8’ vertically or 5’ horizontally of grounded objects Hazardous locations Supplied by metal clad, metal sheathed or metal raceway Any terminal at over 150v to ground Appliances to be Grounded (g)(6)(iii) & (g)(6)(iv)(A)

Appliances Shall have a disconnecting means Shall have nameplate with rating in volts and amps or in volts and watts Appliance Requirements (j)(3)(ii) – (iii)

Equipment Shall be Grounded Refrigerators, freezers, and air cond. Clothes washer, dryer, dishwasher, sump pumps, aquarium equipment Motor tools Hedge clippers, lawn mowers, snow blowers, wet scrubbers Appliances in wet locations Portable X-ray Portable hand lamps Equipment Grounding (g)(6)(vi)(C)(1) – (6)

Wiring System Prohibitions (a)(1)(iii) No wiring system installed in ductwork used to transport dust, loose stock, flammable vapors, or ducts for commercial cooking equipment

Temporary Power & Lighting not to exceed 90 days (i.e. Christmas lighting, carnivals, etc.) This also includes experimental work and emergencies Temporary Power & Lighting (a)(2)(i)(B)

General wiring No branch – circuit conductors may be laid on the floor All lamps for general illumination shall be protected Flexible cords and cables shall be supported General Wiring (a)(2)(v)(C)

Conductors must be distinguished by color or other means  Grounded conductor  Ungrounded conductor  Grounding conductor Distinguishing Conductors (f)(3)

Motors Disconnecting means “within sight of” and not more than 50’ away Disconnecting shall plainly indicate whether off or on Disconnecting means shall be readily accessible Motors (j)(4)(i)

Transformer vaults Any pipe or duct system foreign to the electrical installation may not enter or pass through the vault Materials may not be stored in vaults Transformer Vaults (j)(5)(vii) – (viii)

Amusement rides and attractions shall be not less than 15’ in any direction from overhead conductors of 600V or less. For conductors over 600V they cannot be below and within 15’ Amusement Rides (k)(2)(ii)