Interior Designers of Canada

Slides:



Advertisements
Similar presentations
Code Analysis:Accessibility Colleen MacEachern & Stephanie Novak.
Advertisements

7 | Means of Egress (Life Safety Code)
Considerations for Special Needs Users Universal Design.
ADA Enhanced Condo Client: Kelly Heller Blind 48 years of age Sculptor
Access Code for Buildings
Means of Egress Talia Ordonez Alex Prodanov Margarita Binkin Team.
2015 Update to OBC September 17, 2014.
of NFPA 101 Life Safety Code 2000 Edition Means of Egress
CURRENT ADA AND ICC COMPLIANCE DATA AN INTRODUCTION TO BOBRICK’S ADA- COMPLIANT PRODUCTS, AS WELL AS BASIC MOUNTING HEIGHTS AND REACH RANGES DOWNLOAD THE.
Proposed Changes to the ADA & ABA Accessibility Guidelines This presentation was prepared by the U.S. Access Board for the ADA Distance Learning 2000 program.
Housing Policy – Meeting the needs of all of the community. Michael Kirby Chief Planning Officer Lancashire County Council.
Stairways and Ladders 1926 Subpart X - Stairways and Ladders
Stairways & Ladders
of NFPA 101 Life Safety Code Administration Definitions General
Accessibility.  A building code is a set of rules that specify the minimum acceptable level of safety for buildings. The main purpose of building codes.
Michigan Department of Licensing and Regulatory Affairs Bureau of Construction Codes.
Universal Designers & Consultants, Inc. The Effect of the DOJ’s Newly Proposed ADA Standards (2004 ADAAG) on Hotel Design Universal.
1. Today’s Agenda Chapter 3: Building Blocks Chapter 4: Accessible Routes Chapter 5: General Site and Building Elements Chapter 6: Plumbing Elements and.
ADA certifiable and Universal Design
2004 Florida Accessibility Code for Building Construction
OSHA Office of Training & Education
OSHAX.org - The Unofficial Guide to the OSHA1 Stairways and Ladders.
Stairways and Ladders.
1 Telecom Cabling Ladder safety. 2 OSHA Office of Training & Education ation Telecom Cabling Stairways and Ladders.
Proposed Guidelines for Pedestrian Facilities in the Public Right-of-Way Scott J. Windley Accessibility Specialist US Access Board.
Sleeping areas: bedrooms, bathrooms, dressing rooms, and nurseries.
LADDER & STAIRWAY SAFETY
Building Planning for Staircases. Relativity, 1953, M.C. ESCHER.
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
2006 Building Code - Overview
Modifying Buildings to Meet the Needs of Seniors Housing Seniors in Rural America Resources, Advocacy and Practice Burlington, VT  June 6, 2012.
Means of Egress Chapter 4.
Fire Safety By Alicia Civile and Alexandra Fernandez.
Difference between 2003 and 2009 ICC/ANSI A117.1 applicable to the Plumbing Subcode Presented by: John N. Terry Tom Pitcherello.
Objective 1.03: Explain ways to adapt housing to meet special needs.
ID 440: Project 1: Hospitality Design
Chapter 5 ID 234 Building Codes Fire Resistant Materials and Assemblies.
UNIVERSAL DESIGN- BARRIER FREE ENVIRONMENTS
BUILDING CODES AND ADA/TAS. BUILDING CODES - EGRESS.
By Angela Forte, Michelle Gagnon, Kerri Morse, & Sam Oosterman.
Objective 1.03: Explain ways to adapt housing to meet special needs.
Means of Egress Part 3 Chapter 4.
OSHA Office of Training and Education 1 Walking-Working Surfaces.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
Chapter 2 Special Considerations in Design Special Populations The American with Disabilities Act of 1990 (ADA) Landmark Civil Rights case that represents.
(ACCESSIBILITY LAW) MINIMUM REQUIREMENTS FOR ACCESSIBILITY
Codes and costing construction + materials II. Building Code (780 CMR) Building Code (780 CMR) Accessibility Code (521 CMR) Accessibility Code (521 CMR)
City of Ottawa Update to Accessibility Design Standards (ADS) Second Edition released November 2015 Jo-anne Moore, P.Eng. Senior Engineer, Guidelines and.
Americans with Disabilities Act (ADA) Standards (Title II & III)
Mayor’s Office on Disability City and County of San Francisco Discussion of Common Design and Construction Errors.
OSHA Office of Training & Education
Garrett Plumstead Nick Pantelakis Eston slacks
Accessible Environment
2009 IBC Egress Issues in Commercial Buildings, May 25, 2011
Walking and Working Surfaces
OSHA’s NEW Walking-Working Surfaces 1910
Stairways & Ladders
Universal Needs - Maslow
AR-315 BUILDING CODES & BYE LAWS
DOOR &WINDOW DEPT. OF CIVIL ENGINEERING By Mr. M. M. MASKE.
Sleeping Area and Bath Facilities
Stairways & Ladders
Stairways & Ladders
Current Scenario in the city Infrastructure :
Concord, New Hampshire September 2, 2010
Campus Ministry Accessibility
Hitchcock architectural barriers: Part 1
BUILT ENVIRONMENT ACCESS AUDITS
Building standards Mr. Da Silva.
LIFT,ESCALATOR AND MOVING WALKS
Presentation transcript:

Interior Designers of Canada ACCESSIBILITY REQUIREMENTS IN CANADA – BASED ON CANADIAN BUILDING CODES Presented to: Interior Designers of Canada

LRI: WHO WE ARE Largest and oldest Building Code/fire protection firm in Canada 3 offices: Toronto (Head Office), Ottawa, Owen Sound We provide services for projects across North America and Internationally

LRI: WHAT WE DO Code Consulting Services Life Safety Services Building Code Review, Fire Code Review, Drawing Review, Fire Modeling, Alternative Solutions Life Safety Services Fire Safety Planning, Fire Safety Training Seminars, Fire Drill Evaluations System Engineering Services Fire Protection Systems Evaluation, Fire Alarm/Fire Suppression Systems Design

WEBINAR AGENDA Review of: Building Codes in Canada Highlights of Barrier-free sections within the National Building Code and Provincial Building Codes Focused highlights of the Accessible Design for the Built Environment (CAN/CSA B651)

BUILDING CODES IN CANADA

BUILDING CODES IN CANADA 2010 National Building Code of Canada (NBC) Model Code for Canada Provincial adoption or adaption of NBC New Brunswick Manitoba Nova Scotia Saskatchewan Newfoundland and Labrador Northwest Territories Nunavut Yukon Prince Edward Island

BUILDING CODES IN CANADA Provincial Building Codes 2006 Alberta Building Code (ABC) 2006 British Columbia Building Code (BCBC) 2006 Ontario Building Code (OBC) 2006 Quebec Construction Code (QCC)

2005 NBC  2010 NBC 2006 Provincial Codes are based on 2005 NBC 2010 NBC Section 3.8. No significant change from 2005 NBC Upcoming 2011 Provincial Codes Section 3.8. may be revised from 2006 editions

OTHER REGULATIONS

ACCESSIBLE DESIGN FOR THE BUILT ENVIRONMENT (CAN/CSA B651) Canadian Standard which can be used in the design and construction of new facilities or modifications to existing facilities, generally as a reference document

OTHER ACCESSIBILITY STANDARDS Additional accessibility documents and standards may be applicable to projects in some provinces/municipalities Client/contract requirements It is the designers responsibility to be aware of all legislated documents and standards applicable to each project

Highlights of Barrier-free National Building Code and Provincial Building Codes

BARRIER-FREE PATH OF TRAVEL An accessible route into and throughout a floor area Permitted to include ramps, passenger elevators, other platform equipped passenger elevating device to overcome a difference in level greater than 13 mm

BARRIER-FREE PATH OF TRAVEL Minimum unobstructed width must be 920 mm with the following exceptions: 1100 mm – OBC 1500 mm – BCBC “lay-by” spaces, for wheelchair passing, must be located not more than 30 m apart and provide a minimum 1500 mm x 1500 mm clear space except the following: 1600 mm x 1600 mm (where the path is less than 1600 mm) – OBC Not required (due to wider path of travel) – BCBC

BARRIER-FREE PATH OF TRAVEL

EXEMPTIONS TO BARRIER-FREE PATH OF TRAVEL (EXCEPT BCBC) Floor levels not served by an elevator, escalator, moving walk, etc. Elevated/sunken portions of a floor area which are provided with the same amenities as the main floor area Dwelling units (i.e. houses and within suites of residential occupancy ); except 10% OBC Rooms/spaces that are “not occupied” are not exempt (i.e. storage rooms)

EXEMPTIONS TO BARRIER-FREE PATH OF TRAVEL - BCBC Storeys above or below the accessible entrance storey in a building/suite not more than two storeys if: less than 600 m2 in area, don’t contain facilities integral to the function of the accessible storey, and don’t contain an assembly occupancy greater than 100 m2 Group C dwelling units, row houses, boarding houses, and lodging houses Floor levels not served by an elevator, escalator, moving walk, etc. are not exempt.

BARRIER-FREE PATH OF TRAVEL – BCBC Barrier-free path of travel is described for specific occupancy groups and specific building types, such as: Theatres, Studios, Opera Houses, Amusement Arcades and Billiard Halls, Schools and Colleges (residential and nonresidential), Drive-in Theatres, Psychiatric Hospitals and Police Stations, Banks, etc.

BARRIER-FREE PATH OF TRAVEL – BCBC Assembly Occupancies - Access must be provided to: Each type of public facility (refreshments, recreational, offices, etc.) Accessible viewing positions Amenities, special-use public areas (i.e. changing rooms, interview rooms, bowling lanes, etc.) Some amenities/areas require “all” to be accessible, others require “at least one” to be accessible

BARRIER-FREE PATH OF TRAVEL – BCBC Care and Detention Occupancies – Access must be provided to: Jails areas where visitors are admitted accessible visitor washrooms Psychiatric Hospitals, Police Stations, and Care Facilities areas where work functions can reasonably be expected to be performed by persons with disabilities accessible washrooms serving each accessible area each type of facility

BARRIER-FREE PATH OF TRAVEL – BCBC Residential Occupancies Apartment/Condominium Buildings Access must be provided from the street and a private parking area to the main entrance, and from the main entrance to an elevator Hotels/Motels Access must be provided to all public facilities/storeys At least one in every 40 sleeping units must be accessible At least one in every 20 sleeping units, which is not accessible must have a visual warning system Public washrooms must be accessible

Residential Occupancies BARRIER-FREE PATH OF TRAVEL – BCBC Residential Occupancies Residential schools/colleges and Dormitories At least one in every 40 bed spaces must be accessible Bed spaces which are not accessible must have a visual warning system Accessible washrooms must be provided to serve accessible bed spaces Residential Clubs Where sleeping accommodation is provided for 10 or more people in single or double rooms, at least one room must be accessible * Sleeping rooms which are not accessible must have a visual warning system

BARRIER-FREE PATH OF TRAVEL – BCBC Business and Personal Services Occupancies General At least one accessible washroom must be either available to all suites or provided in each suite Access must be provided to all public areas Banks Access must be provided to every type of public facility, at least one teller location, and ATMs, night deposit boxes, where provided

Business and Personal Services Occupancies Barbers and Hairdressers BARRIER-FREE PATH OF TRAVEL – BCBC Business and Personal Services Occupancies Barbers and Hairdressers Access must be provided to at least one hairdressing sink, where provided Self-service Laundry and Dry-cleaning Access must be provided to at least one of each type of equipment for public use

BARRIER-FREE PATH OF TRAVEL – BCBC Mercantile Occupancies At least one accessible washroom must be either available to all suites or provided in each suite Access must be provided to all public facilities

BARRIER-FREE PATH OF TRAVEL – BCBC Industrial Occupancies High Hazard – not required Low/Medium Hazard, Service Stations, Parking Garages Access must be provided to all public areas Washrooms provided within a service station must be accessible Within a parking garage, access must only be provided to storeys containing accessible parking spaces

PROTECTION ON FLOOR AREAS WITH A BARRIER-FREE PATH OF TRAVEL Where a barrier-free path of travel is provided to levels above/below the entrance level, protection of the floor area must be protected. Protection is achieved by: Vestibules serving elevator lobbies, Fire compartments (i.e. zones) such that persons with disabilities can be accommodated in each zone and the travel distance from one zone to the other does not exceed the travel distance permitted for the occupancy, or Sprinkler protection

PROTECTION ON FLOOR AREAS WITH A BARRIER-FREE PATH OF TRAVEL

Minimum # of Barrier-Free Pedestrian Entrances BARRIER-FREE ENTRANCES Each building must have barrier-free entrances Not less than 50% of pedestrian entrances - NBC, ABC, QCC At least one main entrance - BCBC Based on table below - OBC Pedestrian Entrances Minimum # of Barrier-Free Pedestrian Entrances 1-3 1 4-5 2 6+ Not less than 50%

DOORS Required minimum clear door width is 800 mm except: 850 mm – OBC Only the active leaf in a multiple leaf door in a barrier-free path of travel must be barrier-free.

DOORS

DOORS Clear space on the latch-side of the doorway is required to provide maneuvering space for wheeled mobility devices on both sides of a door Clear space extends the height of the door and Minimum 300 mm beside the door latch on the push side Minimum 600 mm beside the door latch on the pull side Sliding doors Not specifically addressed – rule of thumb: Minimum 300 mm both sides Each side of any door opening onto a suite in a hotel or motel must have a maneuvering area minimum 1500 mm in diameter on each side (QCC)

DOORS

DOORS Where doors are located in a series (i.e. vestibule) the space between the doors must: Allow for movement of wheelchairs between doors The minimum distance between doors when in the open position is 1200 mm

DOORS Where vision panels are provided in a door, the panel must be (OBC): at least 75 mm wide located with bottom of the panel not more than 900 mm above the floor edge of the panel not more than 250 mm from latch side of the door

DOORS Glazed doors must be designed so that the position of the door is apparent by means of installing non-transparent hardware, bars, or other permanent fixtures. (All except OBC) Glazed doors must be marked with a continuous opaque strip that is (OBC): Colour and brightness contrast with background Minimum 50 mm wide Be located at a height of 1350 mm – 1500 mm above the floor

DOORS Power door operators must be provided at: Barrier-free designated entrances with the following exceptions: Buildings containing a Group B-1, Group C (except hotels), or Group F occupancy Buildings smaller than 500 m2 containing a Group A, Group B-3, Group D, or Group E occupancy Individual suites smaller than 500 m2 in a building containing only suites of Group A, Group B, Group D, or Group E occupancy Universal toilet rooms if equipped with a self-closing device (OBC) Doors not provided with required latch side clearances

RAMPS Minimum clear width between handrails must be 870 mm, except: 890 mm – 940 mm, 1500 mm (BCBC) 900 mm (OBC) Maximum clear width between handrails 920 mm if the ramp does not reduce the required width of a means of egress (QCC)

RAMPS Maximum slope must be 1:12 except: BCBC based on table below Max. Length Max. Landing Interval Required Ramp Width Handrail Required Over 1:20 – 1:16 None 12 m 890 mm – 940 mm Both sides Over 1:16 – 1:12 9 m 890 mm - 940 mm Over 1:12 – 1:10 6 m - 1500 mm Both sides if > 2 m Over 1:10 – 1:8 600 mm Not required

RAMPS Minimum 1500 mm x 1500 mm landings must be provided at the top, bottom, and at intermediate levels leading to a door, except: 1670 mm x 1670 mm (OBC) 1500 mm x width of the ramp (BCBC) At intervals not more than 9 m, landings measuring at least 1200 mm by the width of the ramp must be provided except: 1670 mm x width of the ramp (OBC) 1500 mm x width of the ramp (BCBC – at intervals specified in table on above slide)

RAMPS Landings measuring at least 1200 mm by the width of ramp must be provided at abrupt changes in the direction of the ramp, except: 1200 mm x 1200 mm (ABC - 90° turn) 1500 mm x 1500 mm (ABC - 180° turn) 1500 mm x width of the ramp (BCBC) 1670 mm x width of the ramp (OBC)

RAMPS Walls or guards must be provided on both sides of a ramp Minimum guard height is 1070 mm Guard openings must not permit the passage of a sphere with diameter more than 100 mm Guards must be designed to prevent climbability between 140 mm – 900 mm above the ramp (i.e. horizontal members, attachment, etc.)

RAMPS A ramp must have a curb where a solid enclosure or solid guard is not provided: Minimum 75 mm (BCBC) Minimum 50 mm (OBC) Otherwise, ramps must have a railing or other barrier that extends to: 75 mm of the finished ramp surface (BCBC) 50 mm of the finished ramp surface (OBC)

RAMPS Intermediate handrail if ramp is required to be > 2200 mm wide Handrail height must be 865 mm – 965 mm along the length of ramp Handrails must extend at least 300 mm beyond the top and bottom of the ramp

RAMPS

CONTROLS Controls for power door operators, building services or safety devices, including electrical switches, thermostats, and intercom switches must be installed 400 mm – 1200 mm above the floor except: 900 mm – 1200 mm above the floor (OBC)

WASHROOMS

REQUIRED BARRIER-FREE WASHROOMS A washroom provided on a floor level with a barrier-free path of travel must be barrier-free unless other barrier-free washrooms are provided on the same floor area within 45 m, unless: It is located within a suite of D, E, or F occupancy, is less than 500 m2 (NBC), 300 m2 (OBC), and is completely separated with no access to the remainder of the building. All washrooms in a barrier-free path of travel must be barrier-free unless they are located within an individual suite less than 500 m2 and there are barrier-free washrooms on the same floor area within 45 m (ABC). Where more than one washroom is required, one barrier-free stall must be provided for every 10 stalls (or part thereof).

REQUIRED BARRIER-FREE WASHROOMS A washroom provided on a floor level required to be barrier- free must be barrier-free unless (QCC): It is located within a suite less than 250 m2 and other barrier-free washrooms are provided on the same floor area within 45 m, or The suite has at least one barrier-free washroom on the same floor area In buildings and occupancies required to have washrooms, where the occupant load of the building or occupancy exceeds 150 , barrier-free public washrooms must be provided on floor areas required to be barrier-free (BCBC) At least one universal toilet room is required per accessible building/occupancy (BCBC only)

WATER CLOSETS Seat height must be 400 mm – 460 mm above the floor except: 430 mm- 480 mm above the floor (BCBC) Seat back must be equipped with seat lid or other back support Seat type must not be spring-actuated Flushing controls must be hand-operated and easily accessible to a wheelchair user or automatically operable

WATER CLOSETS * BCBC – 430 mm – 480 mm

WATER CLOSET LOCATION WITHIN A STALL Water closet must be located 285 mm – 305 mm from an adjacent side wall (NBC, QCC) Centreline of water closet 460 mm – 480 mm from an adjacent side wall (ABC, OBC) Centreline of water closet 420 mm – 480 mm from an adjacent side wall and at least 1020 mm from any obstruction on the opposite side (BCBC)

Same requirements as water closet stall (BCBC) WATER CLOSET LOCATION WITHIN A UNIVERSAL Water closet 285 mm – 305 mm from an adjacent sidewall on one side and not less than 875 mm on the other side (NBC, ABC, QCC) Centreline of water closet 460 mm – 480 mm from an adjacent sidewall on one side and not less than 1020 mm on the other side (OBC) Same requirements as water closet stall (BCBC)

URINALS (not addressed in OBC) Height of a wall mounted urinal must be 488 mm – 512 mm above the floor except: 490 mm – 510 mm above the floor (BCBC) Height of a floor mounted urinal must be such that the rim is level with the finished floor Minimum clear width of approach must be 800 mm with no step in front Grab bars must be vertically mounted on each side Urinals – not regulated by OBC

LAVATORIES Centreline location must be at least 460 mm to the sidewall Height of lavatories must be such that the top is not more than 865 mm above the floor except: 840 mm (OBC)

LAVATORIES Clearance beneath the lavatory must be at least 760 mm wide and: 735 mm high at front edge (All except QCC) 685 mm high at a point 205 mm back from front edge except: 250 mm back from front edge (BCBC) 280mm back from front edge (QCC) 230 mm high over the distance from a point 280 mm to a point 430 mm back from front edge except: 250 mm high to a point 500 mm back from front edge (BCBC)

LAVATORIES Lavatory faucet handles Operate automatically or have lever-type handles that do not close under spring action (BCBC, OBC) Located with centreline of faucet to the edge of the basin or front edge of vanity is not more than 485 mm (OBC) Not regulated (NBC, ABC, QCC) Where mirrors are provided above lavatories, at least one must be mounted with bottom edge not more than 1000 mm above the floor, or, be inclined to be usable by a person in a wheelchair

LAVATORIES Dimensions reflect typical requirements (BCBC and QCC differ slightly)

ADDITIONAL EQUIPMENT Horizontal, vertical, sloping and/or L-shaped grab bars are required within water closet stalls, universal toilet rooms, showers and bathtubs. Location varies by fixture and Province Soap dispensers are required Hand dryers/towel dispensers are required

STALL ENCLOSURES Water closet stall enclosures must be at least 1500 mm x 1500 mm, except: Provide an open space 1500 mm diameter (ABC) Doors serving the water closet stall must be at least 800 mm except: 810 mm (OBC) Doors must swing outward, except that inward swinging doors are permitted provided the door swing permits the door to close without interfering with a wheelchair, except: A clear unobstructed space of 760 mm x 1220 mm is provided (OBC) A clear unobstructed space 1200 mm in diameter is provided (QCC) Inward swinging not permitted (BCBC)

STALL ENCLOSURES

STALL ENCLOSURES Clearance beyond water closet stall door must be: Minimum of 1700 mm from stall wall to an in- swinging door 1400 mm from stall wall to wall-mounted fixture/obstruction

STALL ENCLOSURES

UNIVERSAL TOILET ROOMS Internal dimensions between all walls must not be less than 1700 mm except: Floor area not less than 3.7 m2 and no internal dimension between walls less than 1700 mm when door swings out, or Floor area not less than 4.0 m2 and no internal dimension between walls less than 1800 mm when door swings in (BCBC only) Minimum 1500 mm diameter clear space must be provided and is not permitted to overlap fixtures

UNIVERSAL TOILET ROOMS

SHOWERS If showers are provided, at least one shower in each group of showers must be at least 1500 mm wide x 900 mm deep Clear space at shower entrance must be at least 900 mm x the width of the shower except: 1500 mm wide entrance (BCBC)

SHOWERS - SEAT Hinged seat must be minimum 450 mm x 400 mm, at a height of 450 mm above the floor (NBC, ABC, OBC, QCC) Portable or wall-mounted folding seat must be 40 mm – 60 mm less than the shower compartment depth by 430 mm – 530 mm wide, at a height of 430 mm – 480 mm above the floor (BCBC)

SHOWERS

BATHTUBS Bathtubs must be barrier-free if: Installed in a suite of residential occupancy that is required to be barrier-free (NBC, ABC, and OBC for hotels) If bathtubs are provided in a non-residential club, school, or college, a dormitory, or public toilets, at least one bathtub (BCBC) Individual bathtubs provided for patients/residents in Group B, Div. 2 or 3 (OBC) Bathtub must be located in a room that has no internal dimension between walls less than 1700 mm and a 1500 mm diameter clear space (NBC, ABC) Clear floor space must be: 750 mm wide x length of bathtub (NBC) 900 mm wide x length of bathtub (ABC) 800 mm wide x 1500 mm long (BCBC, QCC)

BATHTUBS

COUNTERS Every counter more than 2 m long which serves the public is required to have a barrier-free section except: OBC – not addressed Barrier-free section of counter must be Not less than 760 mm long centered over a knee space not less than 760 mm wide, 685 mm high, and 485 mm deep, and Not more than 865 mm above the floor

COUNTERS

CAN/CSA B651 ACCESSIBLE DESIGN FOR THE BUILT ENVIRONMENT

CSA B651 Addresses topics not regulated by NBC such as: Signage and visual displays Rest area seating Furniture/counters Floor and ground surfaces

CSA B651 Seating spaces for persons in wheelchairs, provided at counters, tables, or other work surfaces must have: Clear floor area at least 750 mm x 1200 mm Adequate maneuvering space to approach them Height between 730 mm – 860 mm from the floor Knee clearance at least 750 mm wide by 480 mm deep by 680 mm high where s forward approach is used (may overlap clear floor area by up to 480 mm)

CSA B651

CSA B651

CSA B651 A bench or seat area must Benches and seats must: Be located adjacent to an accessible route (barrier-free path of travel) Have a level and firm surface Have an adjacent level and firm area at least 850 mm x 1200 mm that is not part of the route of travel Benches and seats must: Be stable Have a seat height of 450 mm – 500 mm from the floor Provide back rest and arm rest options (i.e. some with, some without)

CSA B651

CSA B651 Floor and ground surfaces must: Be stable and firm Be slip resistant Produce minimal glare Not be heavily patterned Detectible floor and ground warning surfaces must be used to inform persons who are walking over them of three possible situations: A hazard indicator signals that a person should stop A warning indicator signals that caution should be taken A directional indicator facilitates way-finding in open areas and signals a route to be taken

CSA B651 A detectible hazard indicator must be located at: An unprotected drop-off edge such as a transit platform, where the elevation change is greater than 250 mm and the slope is steeper than 1:3 The unprotected edges of a reflecting pool Curb ramps An entry into a vehicular route or area where no curbs or other elements separate it from the pedestrian route of travel

CSA B651

CSA B651 A detectible warning indicator must be located at: At the top of stairs where the stairs are not enclosed At each landing incorporating an entrance into a stair system Where the regular pattern of a stairway is broken Where the run of a landing not having continuous handrail is greater than 2100 mm

CSA B651

CSA B651 Where signage, including electronic display monitors, is provided, it must: Be consistently located Be positioned to avoid shadow areas and glare Have a glare-free surface Be of uniform design When used to display the same type of information within the same facility, be consistently shaped, coloured, and positioned Colour-contrasted with its background

CSA B651 Information on visual displays must be: Supplemented by tactile and/or auditory information Colour-contrasted Located on a glare-free surface