1 INTRUSION ALARM TECHNOLOGY NOTIFICATION DEVICES.

Slides:



Advertisements
Similar presentations
Prescient II Extinguishing Control Panels
Advertisements

INTRUSION ALARM TECHNOLOGY
Telephone Entry and Digital Dial Systems High-Tech Solutions for Today's Building Communication Needs Brought to you by :
Burglar & Fire Alarm Basics
ANSI SIA CP-01 CONTROL PANEL STANDARDS
AIM Armstrong’s Intelligent Monitoring Training presentation.
XT30/XT50 Basic Training System Overview
Integrated Technology!
PYROCON12 De-Ice controller Technician Operation Presentation 2013.
Design for the Elderly and Disabled Environments: Making Homes More Comfortable and Accessible Controls and Signals Part 10 of 10.
Deaf and Hard of Hearing Alarm The SafeAwake instantly wakes occupant from deep sleep to alert to smoke and fire. SafeAwake works with smoke alarm system,
EE 294 Master’s Project Spring 2006 D.A.S. Deaf Alert System By Robert Wangai Samer Ashkouri.
1 Bosch Solution 16i Intrusion Control System. 2 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property.
Ted “Smitty” Smith  I have included in the following slides some key sections from each of the codes you will primarily encounter on the test. I recommend.
ROTHENBUHLER ENGINEERING
Remote Monitoring and Management Solutions ®
Basic Fire Alarm Systems Overview
NICET Exam Prep Level II, Class 3.
The Comfort System Product Presentation The Intelligent Home System.
DUE Security and Fire Alarm Systems LEARNING OUTCOME 7B Describe design overview and location considerations.
1 INTRUSION ALARM TECHNOLOGY WIRELESS SYSTEMS. 2 INTRUSION ALARM TECHNOLOGY Wireless systems use radio frequencies (RF) to connect sensors to the control.
1 INTRUSION ALARM TECHNOLOGY LOCAL VS. MONITORING.
1 INTRUSION ALARM TECHNOLOGY DETECTION DEVICES. 2 INTRUSION ALARM TECHNOLOGY Detection devices can be either passive or active. Passive devices typically.
BASIC TELECOMMUNICATIONS
1 The pulse rate in the U.S. is 10 PPS. The break/make ratio is 60/40 DTMF = Dual Tone Multi Frequency Pulse refers to rotary phones Each digit on a telephone.
1 Fiber Optics FIBER OPTIC PATCH PANELS. 2 Fiber Optics Just like our copper cable plant the fiber cable plant incorporates many of the same hardware.
WELCOME DBI & SFFD Meet the Pros October 11, 2007.
COMMERCIAL PAGING AND MUSIC SYSTEMS NBFAA CEU# CARL FOUTZ.
Chapter 14: Inspection and Maintenance
1 INTRUSION ALARM TECHNOLOGY CABLING FOR BURGLAR ALARMS.
INTRUSION ALARM TECHNOLOGY
1 INTRUSION ALARM TECHNOLOGY KEYPADS (CONTROL UNITS)
Activated by the control panel, it gives a loud audio signal to alert that an intrusion has occurred.
RP-2000 Series Deluge & Agent Releasing Panels
Residential/Office Intercom Systems HI-TECH SOLUTIONS FOR TODAY’S HOME /OFFICE COMMUNICATION NEEDS BROUGHT TO YOU BY:
Fire Detection Presentation
Burglar & Fire Alarm Basics
Alarms and Cameras Presented by Sgt. Steve Garst, L.C.C./ C.C.P.S. Little Elm Police Department Little Elm, Texas C.P.T.E.D. The third line of defense.
INTRUSION ALARM TECHNOLOGY
Chapter 2 What is an Alarm System? Alarms: The First Line of Defense
AlphaBlueLight Emergency Call Stations alphacommunications.com/bluelight 42 Central Drive Farmingdale NY Toll-Free Phone:
AVS Audio Verification System
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
1 INTRUSION ALARM TECHNOLOGY POWER SUPPLIES. 2 INTRUSION ALARM TECHNOLOGY Security systems shall have a primary power source and a secondary power source.
Welcome To The Coconut Creek Fire Marshal’s Office Training Smoke Alarm User’s Manual.
Wired Home Security Technologies Wired alarm systems require basic electrical wiring that extends from the control panel and keypad to door and window.
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
Cabling Project. Your first responsibility, as the network designer, will be to have your client specify, in writing, the desired outcome of the project.
1 Structured media enclosure (distribution device) Structured media enclosure (distribution device) BASIC TELECOMMUNICATIONS.
1 Telecom Cabling Residential cabling. 2 Telecom Cabling Approximately 1.6 million new homes are being built in the United States each year, and a surprisingly.
MINNESOTA CHAPTER AUTOMATIC FIRE ALARM ASSOCIATION Requirements of the 2003 Minnesota State Fire Code relating to Group R Occupancies September 14, 2006.
INTRUSION ALARM TECHNOLOGY
Jump to first page 1 Marine Guard Actual Marine Guard 2000 Security System Installation.
Puissant Panel User Training Esc.. 09:11:35 ACTIVE # * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE.
Zones 1 to 8 Siren Keypad Power 12V Data and clock By default: Zone 1 Entry Exit 2 Follower 3 Instant 4 Instant 5 Instant 6 Instant 7 Instant 8 Panic.
1Directional Sound Performance Directional Sound Performance Testing Scott Lang Mike Dybas.
ELECTRICAL WIRING WIRING BASICS Written by Bobby Joslin
New Energy Centre at Megawatt Park 15 April 2014.
Unit 1: Protecting the Facility (Virtual Machines)
Prototyping Home Automation Concepts
We do not have land line and would like the alarm panel to work on GSM
Proposed Changes to the 2009 International Building & Fire Codes
Feature Benefit Feature Benefit Feature Benefit Feature Benefit
AIM Armstrong’s Intelligent Monitoring Training presentation.
Open-Voice Analog Apartment Intercoms
Residential/Office Intercom Systems
Open-Voice Analog Apartment Intercoms
Telephone Entry and Digital Dial Systems
Reason To Install Smart Home System. Smart HomeSmart Home have become much smater about keeping an eye on your home while you're asleep or out for the.
Fire Alarm Practice Drill # 11 Denver Fire Department Journeyman Installer License Test © Ted Smith 2017.
Presentation transcript:

1 INTRUSION ALARM TECHNOLOGY NOTIFICATION DEVICES

2 INTRUSION ALARM TECHNOLOGY Annunciation or notification devices communicate information about an intrusion system to its user. The information can be communicated visually, audibly or both. Annunciation is communicated through the keypads by the use of chimes and buzzers as well visual messages. Annunciation or notification devices communicate information about an intrusion system to its user. The information can be communicated visually, audibly or both. Annunciation is communicated through the keypads by the use of chimes and buzzers as well visual messages.

3 INTRUSION ALARM TECHNOLOGY Notification is achieved through the use of sirens, bells, horns and strobes. Annunciation alerts a user of a status change, for example when arming or disarming a system you will here a chime and see an alphanumeric message. Notification is achieved through the use of sirens, bells, horns and strobes. Annunciation alerts a user of a status change, for example when arming or disarming a system you will here a chime and see an alphanumeric message.

4 INTRUSION ALARM TECHNOLOGY Common notification devices used in alarm systems are horns and sirens.

5 INTRUSION ALARM TECHNOLOGY Horns and sirens should be concealed so that they can not be defeated. In residential dwellings placing a horn in the attic will resonate loud enough for neighbors to hear and it will be difficult to get at. Another option is to hide a horn or siren in the floor rafters in the basement. Horns and sirens should be concealed so that they can not be defeated. In residential dwellings placing a horn in the attic will resonate loud enough for neighbors to hear and it will be difficult to get at. Another option is to hide a horn or siren in the floor rafters in the basement.

6 INTRUSION ALARM TECHNOLOGY For commercial installs horns are placed in steel boxes that are vented to allow the sound to propagate throughout the vicinity. The steel boxes also have a tamper switch connected to the cover so that it can’t be disabled without setting of an alarm. For commercial installs horns are placed in steel boxes that are vented to allow the sound to propagate throughout the vicinity. The steel boxes also have a tamper switch connected to the cover so that it can’t be disabled without setting of an alarm.

7 INTRUSION ALARM TECHNOLOGY Tamper switches are also detection devices, they are spring loaded plunger style switches. WHEN THE DOOR IS OPENED THE PLUNGER SPRINGS FORWARD OPENING THE LOOP AND ACTIVATING AN ALARM. TAMPER SWITCH

8 INTRUSION ALARM TECHNOLOGY One horn or siren can cover approximately 5000 square feet, of course during system testing you will determine if the horn is loud enough to alert neighbors. The horn should have a minimum decibel level of 85dBA to 95dBA which is comparable to a smoke alarm. One horn or siren can cover approximately 5000 square feet, of course during system testing you will determine if the horn is loud enough to alert neighbors. The horn should have a minimum decibel level of 85dBA to 95dBA which is comparable to a smoke alarm.

9 INTRUSION ALARM TECHNOLOGY Another option for notification is alarm sounders, sometimes referred to as screamers these units are smaller and can be recessed into walls. SURFACE MOUNT SOUNDER FLUSH MOUNT SOUNDER

10 INTRUSION ALARM TECHNOLOGY Multiple alarm sounders can be installed throughout the residence or small business to effectively alert the occupants and deter intruders. Sounders are also available with a light/strobe feature built into the unit. Multiple alarm sounders can be installed throughout the residence or small business to effectively alert the occupants and deter intruders. Sounders are also available with a light/strobe feature built into the unit.

11 INTRUSION ALARM TECHNOLOGY If several sounders are used they are wired in parallel. Sirens, horns and sounders come with short pigtails so these connections are spliced onto an 18/2 CL2 cable. If several sounders are used they are wired in parallel. Sirens, horns and sounders come with short pigtails so these connections are spliced onto an 18/2 CL2 cable.

12 INTRUSION ALARM TECHNOLOGY The use of horns and sirens may require a siren driver circuit. This circuit is now part of the majority of control panels, however if you’re adding multiple sirens you will need more power to drive the additional sirens. The use of horns and sirens may require a siren driver circuit. This circuit is now part of the majority of control panels, however if you’re adding multiple sirens you will need more power to drive the additional sirens.

13 INTRUSION ALARM TECHNOLOGY Siren drivers come in many different shapes and sizes, check with your vendor for the siren driver that is compatible with your particular CP SIREN DRIVER: DRIVES 2 X 10W HORN SPEAKERS AT 112DB FROM A 12VDC SOURCE

14 INTRUSION ALARM TECHNOLOGY THE DRIVER’S 12V CONNECTION IS WIRED TO THE SIREN OUTPUT ON THE CONTROL PANEL, AN 18/2 IS CONNECTED TO THE SIREN TERMINALS ON THE DRIVER.

15 INTRUSION ALARM TECHNOLOGY Strobes are usually installed with horns as part of a complete notification system. When these devices are installed outside they should be at a height that is difficult to reach without using a ladder. Strobes are usually installed with horns as part of a complete notification system. When these devices are installed outside they should be at a height that is difficult to reach without using a ladder. 12/24VDC 200mA/120mA

16 INTRUSION ALARM TECHNOLOGY Strobes for security systems are blue or orange, red is reserved for fire alarm. Local codes dictate what color can be used and how long it can flash. Strobes for security systems are blue or orange, red is reserved for fire alarm. Local codes dictate what color can be used and how long it can flash.

17 INTRUSION ALARM TECHNOLOGY When installing the cable for both the horn and strobe 18/4 is probably your best choice. The two extra conductors can be used for the tamper switch, 18/6 should be used if all three devices are needed. When installing the cable for both the horn and strobe 18/4 is probably your best choice. The two extra conductors can be used for the tamper switch, 18/6 should be used if all three devices are needed. STROBE TAMPER HORN

18 INTRUSION ALARM TECHNOLOGY Horns and sirens should sound for no more than five minutes, an additional five minutes is acceptable if another detection device is tripped. Local codes will dictate what is acceptable for siren sounding lengths, five minutes is an industry standard. Horns and sirens should sound for no more than five minutes, an additional five minutes is acceptable if another detection device is tripped. Local codes will dictate what is acceptable for siren sounding lengths, five minutes is an industry standard.

19 INTRUSION ALARM TECHNOLOGY Some alarm systems incorporate pre-recorded messages and may also have a two way audible communication link. This would allow an operator at a monitoring station to talk directly to a user on the premises or warn an intruder that the police are on the way. This link is usually established through the keypads. Some alarm systems incorporate pre-recorded messages and may also have a two way audible communication link. This would allow an operator at a monitoring station to talk directly to a user on the premises or warn an intruder that the police are on the way. This link is usually established through the keypads.