Air Conditioning & Refrigeration:

Slides:



Advertisements
Similar presentations
World Health Organization
Advertisements

Chapter 3. HVAC Delivery Systems
Series L Air conditioners for Laboratories.
Trane Voyager™ rooftop units
Environmental Controls I/IG Lecture 14 Mechanical System Space Requirements Mechanical System Exchange Loops HVAC Systems Lecture 14 Mechanical System.
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®
Foundations of Real Estate Management TM BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building.
The Role of Controls for Indoor Air Quality Kent W. Peterson, PE, Fellow ASHRAE P2S Engineering, Inc. Mid Columbia ASHRAE Chapter.
Heat Recovery for Commercial Buildings
Components of HVAC System
HVAC: heating, ventilating, and air conditioning this is a thermostat: it sends signals to the heating/cooling system.
Heating and Air Conditioning I
HVAC Heating, Ventilation and Air Conditioning -something that you never think about until it doesn’t work properly.
Introduction Enthalpy Wheel
Coupling a Network HVAC Model to a Computational Fluid Dynamics Model Using Large Eddy Simulation Jason Floyd Hughes Associates, Inc Fire + Evacuation.
VAV DESIGN FOR IMPROVED INDOOR AIR QUALITY. “Air conditioning is the control of the humidity of air by either increasing or decreasing its moisture content.
Objectives Finish with ducts and fans Define project topics.
Engineer Presentation
HVAC Systems Overview HVAC Overview - # 1 Tom Lawrence
COMMERCIAL REFRIGERATION
Active beams versus VAV with Reheat Analysis of May 2013 ASHRAE Journal article Ken Loudermilk Vice President, Technology & Developement.
Objectives Finish with Multizone Systems
AIR CONDITIONING SYSTEMS 1. All Air Systems An all-Air System is defined as a system providing complete sensible and latent cooling capacity in the cold.
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
ART 2640, Building Systems of Interior Environments Fall Semester 2014 Tuesdays & Thursdays 9:00-10:20 Grover Center W314 Matthew Ziff, Associate Professor.
ISAT Module III: Building Energy Efficiency
Air Handling Systems Heating Ventilation and Air Conditioning (HVAC) Part 2: Components Supplementary Training Modules on GMP Module 3, Part 2: Components.
Air Conditioning Systems
Conditioning of Moist Air
Important variables Water: Air: Conversion:
Lecture Objectives: Finish with HVAC Systems Discuss Final Project.
Air Handler Terminology
Lecture Objectives: Specify Exam Time Finish with HVAC systems –HW3 Introduce Projects 1 & 2 –eQUEST –other options.
N O R T H A M E R I C A C O M M E R C I A L TDP
Packaged Rooftop Air Conditioning Unit Presents the.
World Health Organization
Lecture Objectives: Clarify issues related to eQUEST –for midterm project Learn more about various HVAC - economizer - heat recovery Discuss about the.
HEATING AND COOLING SYSTEMS
Introduction to Energy Management. Week/Lesson 7 HVAC System Types.
Announcement Course Exam November 3rd In class: 90 minutes long Examples will be posted on the course website.
Geothermal. Defining “Geothermal” Energy Dictionary definition – Relating to the internal heat of the earth The Earth acts as a giant solar collector,
Objectives Describe room distribution basics Select diffusers
Introduction to Energy Management. Week/Lesson 13 Control Strategies for Occupant Comfort.
Lecture Objectives: Discuss the exam problems Answer question about HW 3 and Final Project Assignments Building-System-Plant connection –HVAC Systems.
Technical Seminar on Application and Technical Specification June 2016
HCB 3-Chap 19B: All-Air_Multizone_Reddy1 Chapter 19B: ALL-AIR SYSTEMS FOR MULTIPLE SPACES Agami Reddy (July 2016) 1)CAV terminal reheat 2)CAV multizone.
Space Air Diffusion. Fundamentals  Objectives – thermal comfort and indoor air quality – even space air conditions – acceptable air cleanliness – acceptable.
HCB 3-Chap 19A: All-Air Systems_Single Zone 1 Chapter 19A: ALL-AIR SYSTEMS: SINGLE ZONE AND SINGLE DUCT Agami Reddy (July 2016) 1)Introduction and common.
Design & Analysis of Psychrometric Processes Various ways of Generating A Comfort… BY P M V Subbarao Associate Professor Mechanical Engineering Department.
The cooling/heating fluid used (i) All – air systems
System Diagrams Symbol Library – Black Background David Sellers
Technology in Architecture
ZONING (see section 17.0) Zoning alternatives Constant Volume (CV)
BUILDING HEATING AND COOLING
HVAC Basics Arkan Arzesh HVAC – Heating, Ventilation, Air-conditioning.
Heating, Ventilation and Conditioning (HVAC) for Hospitals
CONFIDENTIAL Technical Seminar on Application and Technical Specification 21 June 2016 Rezza Arif Bin Mustapa Kamal Senior Engineer Project And Application.
Lecture Objectives: Answer questions related to HW 4
HCB 3-Chap 19A: All-Air Systems_Single Zone
VAV DESIGN FOR IMPROVED INDOOR AIR QUALITY
Air Conditioning System-1
Lecture Objectives: Discuss HW4 parts
FBE03: Building Construction & Science
Objective Revie the Cooling Cycle Learn about air distribution systems
Refrigeration & Air conditioning
Chapter 11: DESCRIPTION OF HVAC SYSTEMS
Presentation transcript:

Air Conditioning & Refrigeration: MECH3005 – Building Services http://www.hku.hk/bse/mech3005/ Air Conditioning & Refrigeration: Air-side Systems Dr. Sam C M Hui Department of Mechanical Engineering The University of Hong Kong E-mail: cmhui@hku.hk

Contents Fundamental HVAC Concepts Air Handling Units Air System Basics Fan-duct systems Fan modulation & combinations Year-round operation & economizers Fan energy use & outdoor air

Fundamental HVAC Concepts Five subsystems or loops of HVAC Air-side Chilled water Refrigeration equipment Heat rejection Controls

33 oC, 28 oC 27 oC 33 oC 25 oC Conditioned space

33 oC, 28 oC 27 oC 33 oC 25 oC 13 oC 13 oC Air side system

Chilled water system 33 oC, 28 oC 27 oC 33 oC 25 oC 12 oC 12 oC 7 oC

Refrigeration equipment 33 oC, 28 oC 27 oC 33 oC 25 oC 12 oC 10 oC

Heat rejection 33 oC, 28 oC 27 oC 33 oC 25 oC 12 oC 10 oC 12 oC 49 oC

Control Loop 33 oC, 28 oC 27 oC 33 oC 25 oC 12 oC 10 oC 12 oC 49 oC

Individual room air-conditioning system

Primary air fan coil unit system

What type of air conditioning system it is? Dual duct system

Air Handling Units

Air Handling Units Terminal unit or device Air handling unit (AHU) Such as fan coil units, VAV boxes Air handling unit (AHU) Primary equipment of the air system Handle & condition the air, control it to a required state, and transport it Basic components: Supply fan, water cooling coil, filters, mixing box, dampers, controls & outer casing A return or relief fan is optional, so as a humidifier

Air Handling Units Types of AHUs: Horizontal or vertical Draw-through or blow through Factory-fabricated and field built-up Rooftop and indoor Make-up (primary) air Recirculating

Air Handling Units Package units Rooftop package units A self-contained air conditioner Equipped with a DX (direct expansion) coil “Air handler”: the portion inside that handles air Rooftop package units Gas heating / electric cooling Electric heating / electric cooling Heat pump system

Air Handling Units Indoor package units Split package units Factory-assembly unit installed in a fan room or machinery room Floor-mounted or ceiling-mounted Cooling, cooling/heating, heat pump Heat rejection: Connected to an air-cooled condenser, OR Water-cooled condenser Split package units Indoor air handler + outdoor condensing unit

Air Handling Units Rating conditions & minimum performance ARI and ASHRAE standards Rating indices: Energy efficiency ratio (EER) Seasonal EER Integrated part-load value (IPLV) Heating seasonal performance factor (HSPF)

Air Handling Units Coils Indirect contact heat exchangers Heat transfer between air flowing over the coil and water, refrigerant, steam or brine insider the coil Fins: extended (secondary) surfaces Fin spacing and density Water circuits Number of water flow passages

Air Handling Units Direct expansion (DX) coil Refrigerant is fed (e.g. R-22 and R-134a) Air and refrigerant flow: Usually counterflow and cross flow Typical evaporating temperature = 3-10 oC Condensate drain pan (to collect condensation) Performance factors: Face velocity, heat transfer coefficients, air-side pressure drop, physical size

Air Handling Units Water cooling coils - dry-wet coil Chilled water flowing at 4-10 oC Brine or glycol-water at 1-4 oC Temperature rise (typical) = 7-14 oC Water cooling coils - dry coil Sensible cooling (dry); no condensation Poorer heat transfer coefficient Steam heating coil

Direct expansion (DX) coil Water cooling coil

Water heating coil Steam heating coil

Air Handling Units Air filters Air cleaning and filtration Operating performance: Efficiency or effectiveness of dust removal Dust holding capacity Initial & final pressure drop Service life Types: low-, medium-, and high-efficiency filters + carbon activated filters

Air Handling Units Test methods of air filters Weight arrestance test For low-efficiency air filters Atmospheric dust spot efficiency For medium-efficiency air filters DOP (dioctyl phthalate) penetration and efficiency test For high-efficiency air filters HEPA (high-efficiency particle air) ULPA (ultra-low penetration air)

Activated carbon filter HEPA and ULPA filters Low efficiency (panel-type) Medium efficiency (bag-type)

Air Handling Units Humidifiers Selection of AHUs Steam humidifiers Air washers Selection of AHUs Face velocity < 3 m/s to prevent entrained droplets Proper size of the equipment (energy efficiency) Medium-efficiency filter >50% dust spot eff.: improve IAQ, prevent smudging & discoloring Air economizer: save energy

Steam grid humidifier

Air washer

Air-side Components EcoAdvisor: Energy Trainer for Energy Managers: HAVC Module 1 [AV 697 E19] HVAC components Distribution equipment Air-side components Dampers, filters, coils, fans, ducts and plenums, terminal units, diffusers, humidifiers, dehumidifiers

Air System Basics

Air System Basics Fan-duct systems Flow resistance R, pressure drop Δp and volume flow rate V Duct sections in series: Duct sections in parallel: o

Air System Basics Fan-duct systems Terminology Primary air (conditioned air or makeup air) Secondary air (induced space air, plenum air, or recirculating air) Transfer air (indoor air that moves from an adjacent area) System curve: volume flow vs pressure loss System operating point

Air System Basics Fan Laws Speed (n) Volume flow (V) Total pressure loss (Δp ) Air density (ρ) For air systems that are geometrically & dynamically similar: (D = impeller diameter)

Air System Basics System effect Δpts Its additional total pressure loss caused by uneven or non-uniform velocity profile at the fan inlet, or at duct fittings after fan outlet Due to the actual inlet and outlet connections as compared with the total pressure loss of the fan test unit during laboratory ratings Inlet Outlet

Fan system operating point & system effect

Air System Basics Modulation of air systems Constant volume system Volume flow rate remains constant; supply temperature is raised during part load Variable-air-volume (VAV) system Volume flow rate is reduced to match part load operation Modulation curve

Fan modulation curve

Air System Basics Fan modulation methods Damper (vary the opening of the air flow passage) Waste energy Inlet vanes (opening & angle of inlet vanes) Low cost; less efficient than following types Inlet cone (peripheral area of fan impeller) Inexpensive; for backward curved centrifugal fan Blade pitch (blade angle of axial fan) Fan speed (using adjustable frequency drives) Most energy-efficient; but more expensive

Damper, inlet vanes & fan speed modulation

Air System Basics Fan combinations in AHUs Supply and exhaust fan/barometric damper Used when no return duct or low return pressure loss Barometric relief damper: to prevent excessive high space pressure Suitable for systems w/ no air economizer mode & a low pressure drop in return system

Supply and exhaust fans

Air System Basics Fan combinations in AHUs Supply and relief fan Relief fan to prevent excessive high space pressure Usually operated in air economizer mode Outdoor air damper is fully opened; recirculating damper closed Suitable when pressure drop of return system < 75 Pa, or there is a considerable pressure drop in relief or exhaust flow passage

Supply and relief fans

Air System Basics Fan combinations in AHUs Supply and return fan Return fan at the upstream of the junction of return, recirculating and exhaust flow passage (ru) Has similar characteristics as supply+relief fan, but a higher total pressure at junction “ru” Careful selection of return fan is needed to avoid excessive pressure in the duct system Suitable when pressure drop of return system > 150 Pa, or those requiring a negative space pressure

Supply and return fans

Air System Basics Year-round operation of a VAV system Region I: Refrigeration/evaporative cooling Enthalpy of outdoor > that of recirculating air Region II: Free cooling & refrigeration Enthalpy of outdoor ≤ that of recirculating air Region III: Free cooling, evaporative cooling & refrigeration Region VI: Winter heating

Control diagram of a VAV reheat system for year-round operation

Year-round operation Region I: Refrigeration/evaporative cooling Region II: Free cooling & refrigeration Region III: Free cooling, evaporative cooling & refrigeration Region VI: Winter heating

Air System Basics Economizer A device consisting of dampers and control that uses free cooling capacity of either outdoor air or evaporatively cooled water from cooling tower instead of mechanical refrigeration Air economizer: Enthalpy-based Temperature-based Water economizer

Air System Basics Fan energy use For each l/s air supplied: For system using separate outdoor ventilation:

Air System Basics Outdoor ventilation air supply Aims Provide acceptable indoor air quality Achieve energy efficiency in the system ASHRAE Standard 62-2001 (IAQ standard) Demand-based outdoor ventilation air control using CO2 as an indicator CO2 concentration < 800-1,000 ppm A specific indoor air contaminant can also be used

Air System Basics Outdoor ventilation air supply Minimum outdoor air control Type I: uses a CO2 or mixed gas sensor + DDC controller to control the volume flow rate of outdoor air The best one but can be expensive Type II: uses a CO2 or mixed gas sensor + DDC controller to control the ratio of the openings between outdoor and recirculating dampers Suitable for VAV system

Air System Basics Outdoor ventilation air supply Minimum outdoor air control (cont’d) Type III: uses a flow sensor or a pressure sensor + DDC controller to control the dampers to provide nearly constant volume outdoor air intake More complicated & may cause energy waste Type IV: adjust the opening of outdoor damper manually to provide constant volume outdoor air Mainly used for constant-volume systems