1 Modeling of HVAC System for Controls Optimization Using Modelica Wangda Zuo 1, Michael Wetter 2 1 Department of Civil, Architectural and Environmental.

Slides:



Advertisements
Similar presentations
Page 1 Peng Xu, Philip Haves, James Braun, MaryAnn Piette January 23, 2004 Sponsored by the California Energy Commission and the California Institute for.
Advertisements

MCS LWC MAGNUM ORIGINAL CONCEPTS  Designed to Control Loop Systems  Build to be generic and handle many configurations of Loop Controllers  Type of.
1 Optimal Control of Chiller Condenser Sub-cooling, Compressor Speed, Tower Fan and Pump Speeds, and IGV Omer Qureshi, Hassan Javed & Peter Armstrong,
University of Liège Faculty of Applied Sciences Thermodynamics Laboratory Workshop “Commissioning and Auditing of Buildings and HVAC Systems” Use of a.
Learning Outcomes Upon completion of this training one should be able to: Identify open loop and closed loop campus-type hydronic water system applications.
Smart Devices. Smart Buildings. Smart Business The Potential for DCx Technology Enabled HVAC Operation Scot Duncan, P.E.
Using Benchmarking to Identify Energy Efficiency Opportunity in Cleanrooms; The Labs 21 Approach William Tschudi and Peter Rumsey June 29, 2004
Model predictive control for energy efficient cooling and dehumidification Tea Zakula Leslie Norford Peter Armstrong.
Energy Saving DDC Control Strategies
Workshop « Commissioning and auditing of buildings and HVAC systems » Brussels, January 28th, 2008 Identification of heat recovery on chiller condenser.
44 th Annual Conference & Technical Exhibition By Thomas Hartman, P.E. The Hartman Company Georgetown, Texas Sustainable Chilled Water.
UTSW Thermal Energy Plants, Power Generation and Electrical System What do we do to meet the Emission Reduction, Energy usage Reduction and Electrical.
Integration of Mechanical System Redesign Geothermal Heat Pump Redesign Wesley S. Lawson Architectural Engineering Mechanical Option Pennsylvania State.
1 Operation of heat pump cycles Jørgen Bauck Jensen & Sigurd Skogestad Department of Chemical Engineering Norwegian University of Science and Technology.
September 18, 2009 Critical Facilities Round Table 1 Introducing the Heat Wheel to the Data Center Robert (Dr. Bob) Sullivan, Ph.D. Data Center Infrastructure.
Building Systems Integration - Energy and Cost Analysis The Milton Hershey School New Supply Center Justin Bem AE Senior Thesis – Spring 2007 Mechanical.
 Install new air cooled high efficiency screw chiller (variable speed)  Install new fan coils with ECM motors and low temperature heating coils and proper.
Lecture Objectives: Model HVAC Systems –HW3 Asignemnet Learn about eQUEST software –How to conduct parametric analysis of building envelope.
Overview of Model Predictive Control in Buildings
Overview of Liquid Cooling Systems Peter Rumsey, Rumsey Engineers.
DEA Clandestine Laboratory Training Center Penn State University Architectural Engineering Mechanical Option David M. Potchak.
Chilled water Meyrin consolidation Study 1 st Part Many thanks for their contribution to: Pasquale Alemanno, Fortunato Candito, Alexander Putzu.
Air conditioning – Refreshes your life EWTP MBY Applied Systems Sales1 EWTP-MBYNN Air-cooled Heat Recovery.
1 Medical Office Building. 2 Occupancy – 400 persons 8 a.m. – 5 p.m. Monday - Friday Building Characteristics Three stories 40,000 square feet (200’ x.
Air Conditioning and Computer Centre Power Efficiency The Reality Christophe Martel Tony Cass.
Foothill College & Space Science Center Bill Kelly Viron Energy Services (510) ext 13,
Variable-Speed Heat Pump Model for a Wide Range of Cooling Conditions and Loads Tea Zakula Nick Gayeski Leon Glicksman Peter Armstrong.
Lecture Objectives: Specify Exam Time Finish with HVAC systems –HW3 Introduce Projects 1 & 2 –eQUEST –other options.
The Use of Computational Fluid Dynamics (CFD) in Achieving Energy Reductions in New Zealand’s Industrial Energy Consumption Energy Research Group Department.
Lecture Objectives: Summarize sorption chillers Learn about Chiller modeling Cooling towers and modeling.
November 2004 Low Hanging Fruit Low Cost Energy Efficiency Opportunities in Cleanrooms.
Overview of Data Center Energy Use Bill Tschudi, LBNL
Lecture Objectives: Learn about Chiller modeling
Bronx School for Law Government & Justice Yulien Wong Mechanical Option 2006 Senior Thesis Bronx, New York.
The Data Center Challenge
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
APPELL LIFE SCIENCES York College of Pennsylvania Joshua Martz | Dr. Srebric | April 11, 2011 Image Courtesy of RLPS, Ltd.
2003 ASHRAE Annual Meeting Kansas City Energy Conservation Benefits of a DOAS with Parallel Sensible Cooling by Ceiling Radiant Panels Jae-Weon Jeong Stanley.
Introduction to HVAC Optimization
Announcement Course Exam November 3rd In class: 90 minutes long Examples will be posted on the course website.
Building Systems Integration - Energy and Cost Analysis The Milton Hershey School New Supply Center Justin Bem AE Senior Thesis – Spring 2007 Mechanical.
Lecture Objectives: Cooling towers and modeling Project 1 Thermal storage systems.
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
Lecture Objectives: Differences in Conduction Calculation in Various Energy Simulation Programs Modeling of HVAC Systems.
Data Center Energy Use, Metrics and Rating Systems Steve Greenberg Energy Management Engineer Environmental Energy Technologies Division Lawrence Berkeley.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
Michael Reilly, Jr. – Mechanical Option Advisor – James Freihaut, PhD & Dustin Eplee The Pennsylvania State University Nassau Community College Life Sciences.
A Calculator for Reliably Measuring the Savings from Advanced RTU Control Retrofits August 27, 2015 Presentation to: RTF Commercial Rooftop Unit Working.
Oak Ridge National Laboratory
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Lecture Objectives: Learn about thermal storage systems
The Data Center Challenge
Lecture Objectives: Discuss Final Project
We need to decide about the time for the final project presentation
Lecture Objectives: Continue with air-conditioning (psychrometric)
Grunenwald Science and Technology Building
HVAC Basics Arkan Arzesh HVAC – Heating, Ventilation, Air-conditioning.
Lecture Objectives: Answer questions related to HW 4
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Lecture Objectives: Answer questions related to HW 4
Energy Efficiency in District Coiling System
Chilled Beam Performance:
Senior Thesis Presentation
Lecture Objectives: Look at the cooling side of air condition
Loop Water Controller Overview
Frenger “Radiant” chilled beam performance at 1 Shelly St - Sydney
Lecture Objectives: Discuss HW4 Chiller modeling
Lecture Objectives: Discuss HW4 parts
When: Monday 26, 4 pm Where: ECJ Building, Classroom 3.402
Calibrated Energy Models: One New Change
Presentation transcript:

1 Modeling of HVAC System for Controls Optimization Using Modelica Wangda Zuo 1, Michael Wetter 2 1 Department of Civil, Architectural and Environmental Engineering, University of Miami, Coral Gables, FL 2 Building Technology and Urban Systems Department, Lawrence Berkeley National Laboratory, Berkeley, CA Intelligent Building Operations Workshop 06/21/2013

2 Outline Introduction Case 1: Modeling a Direct Expansion Coil Case 2: Optimization of Chiller Plant Control for Data Center Conclusion and Outlook

3 Introduction Motivation Energy saving potential from better building control is about 30% Computer tools can be used for the design, evaluation and optimization of HVAC control Limitation of Current Tools Idealized control Time step too large Fixed time step Opportunity with Modelica Equation-based object-oriented modular modeling Fixed and variable time step solvers

4 Case 1: Modeling of a DX Coli 4 North Wing of Building 101, Philadelphia, PA DX Coil with 2 Condensing Units

5 Measured Data Measured Power for August 2012

6 Model Calibration Design Using measured data to calibrate the nominal COPs for performance curves of 6 stages so that calculated energy consumption is close to measured data.

7 Calibration Power [W] Energy [J] ModelMeasured Data T out [degC] 0.3% difference Variable Speed DX coil, 8/1-8/7/2012

8 Validation Power [W] Energy [J] ModelMeasured Data T out [degC] 4% difference Variable speed DX Coil, 8/15-8/21/2012

9 Discrete vs. Continuous Time Control Option 1: Variable Speed DX Coil Control input: Real from 0 to 1 Coil runs smoothly using performance curves for 6 speeds Option 2: 6 Stage DX Coil Control input: Integer from 0 to 6 A time delay t wai is used to prevent short cycling

10 Discrete vs. Continuous Time Control 6-Stage DX Coil, t wai =120s (Discrete) Variable Speed DX Coil (Continuous) ModelMeasured Data T out 6-Stage DX Coil, t wai =1s (Discrete) Simulation of 8/1-8/7/2012

11 Discrete vs. Continuous Time Control DX Coil ModelCPU TimeState Events Variable Speed10s1 6-Stage (t wai =120s) 46s3,912 6-Stage (t wai =1s) 1,850s64,330 Simulation of 8/1-8/7/2012 Comparison of Numerical Performance

12 Outline Introduction Case 1: Modeling of a Direct Expansion Coil Case 2: Optimization of Chiller Plant Control for Data Center Conclusion and Outlook

Case 2: Chiller Plant for Data Center Cooling Objective: W (Pump) W (Fan) W (Chiller) ↑↑↑↓↓ ↓↓↓↑↑ Challenges in Optimization: Background: 1.5 percent of the nation’s electricity. half of the electricity in data centers is used for cooling.

14 Configurations Cooling Load500 kW LocationSan Francisco Water Side Economizer (WSE)a. Without WSE; b. With WSE Supply Air Set Temperature (T air,set )From 18 C to 27 C Max Chiller Setpoint (T chi,max )From 6 C to 26 C WSE T air,set T chi,max Condenser Water Pump Chilled Water Pump Fan

15 Modelica Models of Chiller Plant with WSE

Setpoint Reset Control 16 Modelica Implementation Chilled Water Loop Difference Pressure and Chiller Setpoint Temperature Reset

Water Side Economizer Control 17 Modelica Implementation Schematic of State Graph

Results: With and Without WSE 18 How much does the 0.13 in PUE for a 500 kW data center mean? -438,000 kWh / year -$87,600 if $0.2 / kWh

Results: With and Without WSE 19 Without WSEWith WSE

System With WSE: Hours of Chiller Operation 20 T air,set 18C 27C T chi,max 6C 22C

System with WSE: Control Actions in a Hot Day 21 June 30

Discrete vs. Continuous Time Control 22 Discrete Time Control (Trim and Response Logic) Continuous Time Control (PI Control)

Discrete vs. Continuous Time Control 23 Comparison of Numerical Performance DiscreteContinuous CPU time for simulation of 1 week 7.58 s0.26 s Number of steps10, Number of (model) time events5,0400

24 Outline Introduction Case 1: Modeling of a Direct Expansion Coil Case 2: Optimization of Chiller Plant Control for Data Center Conclusion and Outlook

25 Conclusion and Challenges Conclusion The case studies demonstrate the potential of Modelica for the modeling and optimization of HVAC system control Model performance varies depending on how it is constructed Challenges How to ensure that the models can be stably and efficiently solved? How to handle the fast transient in control system and slow response in building thermal system at the same time?

Acknowledgements Collaborators: Purdue University: Donghum Kim, James Braun EEB Hub: Ke Xu, Richard Sweetser, Tim Wagner Funding Agencies: Department of Energy Energy Efficient Buildings Hub 26