pae consulting engineers, inc. Nick Collins, P.E., LEED™ AP

Slides:



Advertisements
Similar presentations
Sustainable School Design Creating Healthy, High Performance School Facilities Presented by Stephen M. Koontz, Energy Services Leader, Tampa Bay Trane.
Advertisements

Chapter 3. HVAC Delivery Systems
BUILDING AIR CONDITIONING
Heating, Ventilating, and Air-Conditioning
Heating, Ventilating, and Air-Conditioning
Environmental Controls I/IG Lecture 14 Mechanical System Space Requirements Mechanical System Exchange Loops HVAC Systems Lecture 14 Mechanical System.
Heating, Ventilation and Conditioning (HVAC) for Hospitals 1 Presentation for: Presented by Leach Wallace Associates September 8, 2011.
Commercial Mechanical Requirements
TYPES OF MECHANICAL SYSTEMS
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
Heating, Ventilating, and Air-Conditioning (HVAC)
Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®
Foundations of Real Estate Management TM BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building.
Geothermal Retrofit of HVAC Systems
Technology in Architecture Lecture 10 Mechanical Systems Lecture 10 Mechanical Systems.
Components of HVAC System
HVAC: heating, ventilating, and air conditioning this is a thermostat: it sends signals to the heating/cooling system.
HVAC Heating, Ventilation and Air Conditioning -something that you never think about until it doesn’t work properly.
Mechanical Engineering Department  Temperature Control  Cooling  Heating  Humidity Control  Humidification  Dehumidification  Air Quality Control.
Chilled Beam Presentation
HVAC Systems Overview HVAC Overview - # 1 Tom Lawrence
Announcement Course Exam October 6 th (Thursday) In class: 90 minutes long Examples are posted on the course website.
Lecture Objectives: Model processes in AHU –Use eQUEST predefined models –Use detail modeling Define your topics for your final project.
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
Lecture Objectives: Model processes in AHU –Use eQUEST predefined models –Use detail modeling Define your topics for your final project.
Equation solvers Matlab Free versions / open source codes: –Scilab MathCad: Mathematica:
Important variables Water: Air: Conversion:
Announcements Midterm Project Prepare groups of 3 to 4 students You can submit the list at the end of next class Midterm Exam 03/09/10 - In class Exam:
Lecture Objectives: Finish with HVAC Systems Discuss Final Project.
Heating Systems.
Lecture Objectives: Specify Exam Time Finish with HVAC systems –HW3 Introduce Projects 1 & 2 –eQUEST –other options.
Design of HVAC systems for bld 3862 – LHCb control room and for bld 2885 – LHCb new workshop.
N O R T H A M E R I C A C O M M E R C I A L TDP
Lecture Objectives: Clarify issues related to eQUEST –for midterm project Learn more about various HVAC - economizer - heat recovery Discuss about the.
Facilities Management and Design Chapter 7 HVAC Systems.
Introduction to Energy Management. Week/Lesson 7 HVAC System Types.
Greenbriar East Elementary School Fairfax, Virginia Michelle L. Siano Mechanical Option Spring 2005 Senior Thesis.
Announcement Course Exam November 3rd In class: 90 minutes long Examples will be posted on the course website.
Introduction to Energy Management. Week/Lesson 13 Control Strategies for Occupant Comfort.
Hamot Women’s Hospital Erie, PA Michael Galleher Mechanical Option l AE-Senior Thesis l April 12, 2011 l Advisor Dr. Jelena Srebric.
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
Lecture Objectives: Discuss the exam problems Answer question about HW 3 and Final Project Assignments Building-System-Plant connection –HVAC Systems.
The New Student Housing Building at The Mount St. Mary’s University Emmitsburg, Maryland Erik Shearer Mechanical Option Advisor: Dr. Srebric Spring 2007.
Using Heat Part 2. Science Journal Entry 32 Explain the advantages and disadvantages of thermal expansion.
EXAMINATION 3 REVIEW FORMAT & AREAS COVERED DISTRIBUTION SYSTEMS DELIVERY DEVICES UNITARY SYSTEMS HEAT PUMPS SPACE REQUIREMENTS & DESIGN CONSIDERATIONS.
HVAC Energy Efficiency using Mass Flow and Building Pressurization Jay Richardson Professional Supply, Inc.
Chapter 14 Heating, Ventilation & Air conditioning (hvac)
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Lecture Objectives: Discuss Final Project
Technology in Architecture
Heating, Ventilating, and Air Conditioning
Heating Ventilating and Air Conditioning
Grunenwald Science and Technology Building
HVAC Basics Arkan Arzesh HVAC – Heating, Ventilation, Air-conditioning.
Heating, Ventilation and Conditioning (HVAC) for Hospitals
Types of HVAC Technology Used in Business Establishments
Lecture Objectives: Answer questions related to HW 4
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Lecture Objectives: Answer questions related to HW 4
Heating, Ventilating, and Air-Conditioning
Chapter 11: DESCRIPTION OF HVAC SYSTEMS
Lecture Objectives: Discuss HW4 parts
INNOVATION lab MEP MECHANICAL/ELECTRICAL/PLUMBING :
FBE03: Building Construction & Science
Technology in Architecture
Objective Revie the Cooling Cycle Learn about air distribution systems
Refrigeration & Air conditioning
Chapter 11: DESCRIPTION OF HVAC SYSTEMS
Presentation transcript:

pae consulting engineers, inc. Nick Collins, P.E., LEED™ AP Mechanical Systems pae consulting engineers, inc. Nick Collins, P.E., LEED™ AP nickc@pae-engineers.com inspire interpret integrate

? Mechanical Systems What kind of mechanical system?

Mechanical Systems Install the smallest, most efficient system possible: Reduce perimeter loads through careful skin design. Reduce internal loads: laptops, energy star equipment. Multnomah County Hillsdale Library Architect: Thomas Hacker and Associates

What Factors Determine the Mechanical System Selected? Building Type Office Housing Education, Higher Ed or Secondary Industrial Maintenance Comfort Mark O. Hatfield US Courthouse Architect: BOORA Architects Sokol Blosser Wine Barrel Storage Facility Architect: SERA Architects

ASHRAE summer and winter comfort zones.

Mechanical Systems Passive vs. Active PAE Offices

Active Systems Cooling Heating Air Distribution COOLING Direct Expansion Packaged Rooftop Chilled Water Air Cooled Water Cooled Central Ground Water Direct and Indirect Evaporative Cooling Distributed Heat Pumps Active Systems Cooling Heating Air Distribution HEATING Hydronic Conventional Hot Water Boilers High Efficiency Hot Water Boilers (Gas) Electric Heat Gas Fired Ground Coupled Heat Pump   AIR HANDLING Central Rooftop Penthouse or Inside Distributed Air Handling Fan Coils Unit Ventilators Heat Pumps

Active Cooling Systems Direct expansion Chilled water - Air cooled - Water cooled - Ground Water Direct and indirect evaporative cooling Distributed heat pumps

Cooling Systems Chilled Water Package Rooftop First Cost: Lowest potential first cost. Energy Cost: Higher energy cost. Maintenance: High maintenance costs - expected life of 15 years. Comfort: Reasonable – potential acoustical issues. University of Oregon School of Music & Dance Architect: BOORA Architects

Cooling Systems Chilled Water Air Cooled First Cost: In conjunction with air handlers. Energy Cost: Better than rooftop option. Maintenance: Lowest maintenance cost option - average life of 17 years. Comfort: High level of comfort.

Cooling Systems Water Cooled First Cost: Greatest first cost. Energy Cost: Lowest Energy cost. Maintenance: Equipment is highly reliable - chiller life is 27 years. Comfort: Provides the best in comfort - quiet operation.

Ground Source Heat Pumps GS heat pumps extract geothermal energy to condition buildings. Very low energy consumption. Winter – moves heat from the earth to the building Summer – moves heat from the building to the earth Automatic controls are used to reverse the direction of the heat transfer

Ground Water PSU Northwest Center for Engineering, Science and Technology. Ground water well system with extraction and insertion wells. No Boiler or Cooling Tower Ground water is used for heating and cooling.

Heating Systems Active Systems – Heating Hydronic - Hot water boiler - High efficiency boiler - condensing Electric heat Gas fired

Heating Systems Hydronic Heating Systems Energy Cost: Mid range, between electric heat and high efficiency hot water. Maintenance: Requires little maintenance. Comfort: Excellent comfort.

Radiant Floor Heating Consistent heating Low energy usage Slow response time

Heating Systems Electric Heat First Cost: Low first cost. Energy Cost: Very high. This will represent a 100% to 150% increase in energy cost due to rate differences between gas and electric. Maintenance: Low maintenance. Comfort:Step control on electric heaters. Acceptable comfort.

Active Systems – Air Handling Central Distributed - Fan Coils - Unit Vents - Heat Pumps

Air Handling Package Air Handler Variable Air Volume Air Handler Distribution: Conventional overhead Underfloor Lower energy savings - longer economizer cycle Smaller cooling zone

Air Handling Systems Heat Recovery Energy cost: Low energy cost. Maintenance: Same as air handler. Comfort: Less than air handler, if provided without coils.

Natural Ventilation Passive Cooling PAE Offices

Advantages of Natural Ventilation Simple Lower first cost (15% less) Lower operating cost (40% less) User satisfaction through greater control Elimination of mechanical refrigeration Less environment impact No mechanical noise

Advantages of Natural Ventilation Option A Simple Lower first cost (15% less) Lower operating cost (40% less) User satisfaction thru greater control Elimination of mechanical refrigeration Less environment impact No mechanical noise inspire interpret integrate

Disadvantages of Natural Ventilation Temperature & humidity cannot be tightly controlled No filtration Reduced security First cost higher if back-up A/C system is also required Exterior noise can be a problem Less flexible air intake locations – air quality issues Large openings required with mass inspire interpret integrate

Disadvantages Temperature and humidity cannot be tightly controlled No filtration Reduced security First cost higher if back-up A/C system is also required Exterior noise can be a problem Less flexible air intake locations – air quality issues Rain

Strategies Single-sided opening ventilation Cross ventilation Stack-induced flows through double opening

Washington School for the Deaf Classroom Natural Ventilation Daylighting Thermal Mass Night Flush No Filtration

Thermal Mass / Night Ventilation Need approximately 2 to 3 times the floor area Can reduce maximum daytime temperature

Sustainable Design Mechanical Systems What system? That depends . . . Reduce loads to lowest possible amount Know your client, maintenance, comfort, operating schedule, etc. Select most efficient system possible System Types - Active - Passive - Mixed Mode

Shattuck Hall – Case Study Existing Mechanical Systems Two dedicated outside air units with steam heat, evaporative air cleaners Multiple air zones with mix dampers Gravity relief from each zone (open relief duct on roof) Other smaller mechanical systems. pae consulting engineers, inc. inspire interpret integrate

Existing Classroom inspire interpret integrate

Old Zone Dampers - Mixing inspire interpret integrate

Mechanical Systems Options HVAC Option C – Conventional VAV Hot water heating Variable volume AHU’s Medium pressure supply ductwork VAV air terminal units in each space Low pressure return ductwork Return air plenums   HVAC Option D – Dedicated OA/Radiant Hot water heating radiant panels Fan-induced ventilation Operable windows – manual New AHU’s/Existing ductwork - for minimum outside air Radiant Cooling – radiant cooling panels or chilled beams HVAC Option A – “Natural” Ventilation Hot water heating radiators Operable windows – automatic, with trickle vents Building Mass/Night Flush Cooling   HVAC Option B – “Natural” Ventilation/Mixed Mode Fan-induced ventilation Operable windows automatic New AHU’s/Existing Ductwork Cooling coils in new AHU’s deliver cold air through existing ductwork on extremely hot days   pae consulting engineers, inc. inspire interpret integrate

Shattuck Hall New Mechanical Systems Two dedicated outside air units with hot water heating, campus chilled water and filters Temperature zones with VAV terminal units Radiant heating and cooling panels Gravity relief from each zone (open relief duct on roof) Other smaller mechanical systems. pae consulting engineers, inc. inspire interpret integrate

Estimated Energy Usage Energy Use in Shattuck Hall Estimated Energy Usage No envelope upgrades inspire interpret integrate

Radiant Panel Concerns Guinea Pig or Innovative Comfort Noise Condensate Valve locations Hot water leaks Flexibility inspire interpret integrate

Radiant Panels and Valves inspire interpret integrate

Heat inspire interpret integrate

Radiant Ceiling Heating / Cooling Dedicated outside air for dehumidification Low mass means faster response time Uniform heating and cooling Low energy usage inspire interpret integrate