Research X-ray Safety Fundamentals Office of Research Safety 114 Long Hall.

Slides:



Advertisements
Similar presentations
ANALYTICAL X-RAY SAFETY User Training Centre for Environmental Health, Safety and Security Management.
Advertisements

Chapter 11 Prime Factors.
Laser Awareness (Non-User). 2 What is a laser? Laser is an acronym for Light Amplification by Stimulated Emission of Radiation.
Radiation Protection Of Health Care Workers Kyle Thornton RADL 70.
X-Ray Interaction with Matter & Human Biology
We wish to acknowledge and thank Mr. Adam Weaver, CHP, University of South Florida for the use of this X- Ray training module. It has been modified for.
Nuclear Instability.
University of Minnesota Duluth Radiation Safety Annual Refresher Training Radiation Protection Division Department of Environmental Health & Safety.
Unit 1 Physics Detailed Study 3.6 Chapter 15: Medical Physics.
1 USF Radiation Safety Research X-ray Safety Fundamentals Goals of this training presentation: 1.Explain what are X-rays. 2.Explain the hazards of X-ray.
X-Ray Production & Emission
Personal Radiation and Occupational Safety – CT Policy This policy is in both paper form in the lab’s compliance manual, and on a Power Point presentation.
Dental Assisting Radiology
Quality Control Rad T 110.
Stopping Power The linear stopping power S for charged particles in a given absorber is simply defined as the differential energy loss for that particle.
Office of Environmental Safety X-ray Safety Training.
ANALYTICAL X-RAY SAFETY User Training Centre for Environmental Health, Safety and Security Management.
BASIC PRINCIPLES IN OCCUPATIONAL HYGIENE Day IONIZING RADIATION.
IONIZING RADIATION ….. a discussion of the health hazards associated with handling and use of materials capable of producing ionization of matter.
Radiation. Ionising Radiation Alpha Radiation Beta Radiation Gamma Rays X-Rays Neutrons.
DMI 261 Radiation Biology AndProtection. Unit 2 RADIATION Electromagnetic Spectrum –The frequency range of electromagnetic radiation and the photon wavelength.
Chapter 3 Radiation Safety Vet Tech Institute. Radiation should be respected not Feared! Safety is Always important! Safety is Always important! Stray.
 Justification is the answer.  Dose limits are not applicable only recommened.
HABIS X-RAY PRODUCTION AND EXPOSURE FACTORS X-RAY PRODUCTION AND EXPOSURE FACTORS PREPARED BY PREPARED BY Dr fahad albadr radiology chairman radiology.
Interactions of Radiation With Matter
Radiography Testing 1 Radiography Testing (RT), or industrial radiography is a nondestructive testing (NDT) method of inspecting materials for hidden flaws.
BASIC CONCEPTS How much do you already know?. ????QUESTIONS??? n MATTER n Occupies_____________ n is a material substance n Has________and shape n Building.
/0409 Copyright ©2004 Business and Legal Reports, Inc. BLR’s Safety Training Presentations Ionizing Radiation 29 CFR
1 IONIZING RADIATION. 2 Non-Ionizing Radiation Does not have enough energy to remove electrons from surrounding atoms.
Introduction to Radioisotopes: Measurements and Biological Effects
NUCLEAR VS. CHEMICAL CHEMICAL reactions involve rearranging of atoms: e.g., H 2 +O 2  H 2 O No new atoms are created. Chemistry involves electrons only.
1. 2 Radiation Safety 3 What is Radiation? Radiation is a form of energy. It is emitted by either the nucleus of an atom or an orbital electron. It.
HEALTH PHYSICS TERMS l RAD (Gy) l mRad l R l mR l Rem l ALARA l NCRP.
RADIATION SAFETY Mrs. Brinston. Introduction As a healthcare worker, you know that radiation is an important tool for detecting and treating diseases.
Basic radiation protection & radiobiology
Photon Tissue Interactions
Ferris State University & Michigan Department of Career Development 1 Radiation Safety Answer Key.
Atomic Structure.
30.1X-rays and radioactivity X-rays are a kind of electromagnetic wave of high frequency (i.e. short wavelength). Nature of X-rays radio wave micro- wave.
Attenuation As x-rays pays through matter, the exit beam will contain less photons than the entrance beam. This reduction in the quantity of photons is.
Half Life. Half-life is the time it takes for half of the atoms of a sample to decay. For example: A student was testing a sample of 8 grams of radioactive.
Week 2 :Radiation Protection
X-Ray Diffraction Safety at UIC
Interaction of Radiation with Matter
Protection1 Radiation Protection. Protection2 BENEFITS VS. ADVERSE EFFECTS.
Welcome to Radiology Introduction and Chapter 1. What to Expect You are going to learn a lot in a short period of time. This is a very fast paced class,
Analytical X-Ray Systems: Radiation Safety for X-ray Machines
CSULB Radiation Safety Research X-ray Safety Fundamentals
Radiation Protection RTMR 284 CHAPTER 20 PART II.
RADIATION PROTECTION 04/12/2016.
Topic 6 : Atomic and Nuclear Physics.
University of Minnesota Duluth
X-RAY PRODUCTION AND EXPOSURE FACTORS
Stat Ch 8 & 9 RHB – Rad Prot Syllabus
X-Radiation.
Interactions of Radiation With Matter
IONIZING RADIATION ….. a discussion of the health hazards associated with handling and use of materials capable of producing ionization of matter.
Stacy Kopso, M.Ed., RT(R)(M)
Radiation Safety.
Radiation Safety Training Research & Analytical Machines Washington State University Radiation Safety Office.
Radiation Badge Training
RADIATION TERMS AND UNITS
Occupational Radiation Dose Management
Occupational Radiation Dose Management
Non-Radiation Worker Training
Occupational Radiation Dose Management
Phenotyping Facility X-ray Awareness Training
Radiation Badge Training
Presentation transcript:

Research X-ray Safety Fundamentals Office of Research Safety 114 Long Hall

Define x-rays Explain the hazards of x-ray devices used in research List the requirements and responsibilities for the safe use of x-ray devices Help you recognize and respond to unsafe conditions Goal of this Training: 2

Radiation is energy in the form of waves or particles. Radiation of a high enough energy is called : IONIZING RADIATION Ionizing radiation includes x-rays, gamma-rays, beta particles, alpha particles, and neutrons. Without the use of monitoring equipment, radiation is undetectable. Humans are not able to see, feel, taste, smell, or hear ionizing radiation. What is Radiation? 3

X-rays are a form of electromagnetic radiation produced when electrons are deflected from their original paths or change their orbital levels around the atomic nucleus. X-rays are capable of traveling long distances through air and most other materials. Like gamma rays, x-rays require more shielding to reduce their intensity than do beta or alpha particles. X and gamma rays differ primarily in their origin: x-rays originate in the electronic shell gamma rays originate in the nucleus What are X-rays? 4

X-rays were discovered in 1895 when Wilhelm Conrad Roentgen observed that a screen coated with a barium salt fluoresced when placed near a cathode ray tube. Roentgen concluded that a form of penetrating radiation was being emitted by the cathode ray tube and called the unknown radiation: X-rays 5

An x-ray tube requires a source of electrons, a means to accelerate the electrons, and a target to stop the high-speed electrons. X-ray Tube 6

In passing through matter, energy is transferred from the x-ray photon to electrons and nuclei in the target material. An electron can be ejected from the atom with the subsequent creation of an ion. The amount of energy lost to the electron is dependent on the energy of the incident photon and the type of material through which it travels. There are three basic methods in which x-rays interact with matter: photoelectric effect Compton scattering pair production X-ray Interactions 7

Two main uses: Diffraction [XRD] X-ray scattering from crystalline materials. “fingerprint” of crystalline atomic structure. Check known library vs. unknown sample. Fluorescence [XRF] Analytical method for determining the elemental composition of a substance. Analytical X-rays 8

The primary beam: The primary beam is most hazardous because of the extremely high exposure rates. Exposure rates of 4 x 10 5 R/min at the port have been reported for ordinary diffraction tubes. Leakage or scatter of the primary beam through cracks in ill fitting or defective equipment: The leakage or scatter of the primary beam through apertures in ill fitting or defective equipment can produce very high intensity beams of possibly small and irregular cross section. Penetration of the primary beam through the tube housing, shutters or diffraction apparatus: The hazard resulting from penetration of the useful beam through shutters or the x-ray tube housing is slight in well designed equipment. Adequate shielding is easily attained at the energies commonly used for diffraction and florescence analysis. Diffracted rays: Diffracted beams also tend to be small and irregular in shape. They may be directed at almost any angle with respect to the main beam, and occasionally involve exposure rates of the order of 80 R/h for short periods. Hazards of Analytical X-ray Equipment 9

10 Putting fingers in X-ray beam to change sample Aligning X-ray beam visually Modification of shielding Failure to realize X-rays are emitted from several ports Failure to read & follow manufacturers X-ray operating instructions Any of these actions could cause an unnecessary exposure!

Safety interlocks may consist of switches or other devices that prevent operation of the x-ray device with shielding removed. X-ray devices should NEVER be operated with the safety interlocks bypassed. A written procedure must be approved by the Radiation Safety Officer PRIOR to performing any work with safety interlocks defeated. Safety Interlocks 11

The most common effects from a large radiation exposure from an x-ray device is reddening of the skin (erythema). With a dose of a few hundred rem the superficial layers of the skin are damaged and the skin will redden in a fashion similar to a sunburn. The erythema effect will most often reverse itself within a few weeks. Contact the Radiation Safety Officer immediately if an overexposure is suspected! Symptoms of Local X-ray Overexposure 12

Two main types of diagnostic x-ray devices: Radiograph – a picture with film or image is sent direct to computer screen Fluoroscope – a real time “moving” inspection on inside functions Diagnostic radiology is the branch of medicine that has traditionally been known for taking and reading x-rays. Like every other field of medicine, technology has radically changed this specialty forever. Diagnostic radiology is the nucleus of almost every physician’s diagnosis. Being able to detect disease sooner and pinpoint its location more accurately is a huge factor in stopping disease in its tracks. Diagnostic X-rays 13

X-rays are used for non-destructive testing which has applications in a wide range of industries. Non-destructive testing (NDT) means the X-ray beam inspects the integrity of industrial products or processes without damaging the items under observation. The NDT field that uses radiation is called Industrial radiography. Industrial X-ray machines are used primarily to find defects in castings, structures, and welds. These units can also help to find foreign material in food products. X-ray machines are used for the inspection of luggage at airports and buildings. Industrial X-rays 14

The effects of x-ray exposure depends upon: Duration - How fast the dose is delivered. Energy - How much energy was in the x-ray Low Energy (<50 KeV) - damage only to skin or outer part of body High Energy - damage to internal organs Total Dose - The magnitude of the dose X-ray Effects 15

Examples of unsafe conditions: Access door interlocks do not work, shielding has been damaged, or viewing window is cracked. IF AN UNSAFE CONDITION ARISES WITH YOUR X-RAY DEVICE : Stop work! Turn power OFF to X-ray (An X-ray requires power to produce radiation) Notify your Principal Investigator and the Radiation Safety Unsafe Conditions 16

The dose of radiation a worker receives is directly proportional to the amount of time spent in a radiation field. Thus, reducing the time by one-half will reduce the radiation dose received by one-half. Operators should always work quickly and spend as little time as possible next to x-ray equipment while it is operating. Radiation Protection: 17 Time

Radiation exposure decreases rapidly as the distance between the worker and the X-ray device increases. The decrease in exposure from a point source, such as an X-ray tube, can be calculated by using the INVERSE SQUARE LAW: This law states that the amount of radiation at a given distance from a point source varies inversely with the square of the distance. For example, doubling the distance from an x-ray tube will reduce the dose to one- fourth of its original value. Maintaining a safe distance, therefore, represents one of the simplest and most effective methods for reducing radiation exposure to workers. Using the principle of distance is especially important when working around open beam analytical x-ray equipment. Radiation Protection: 18 Distance

Radiation exposure can also be reduced by placing an attenuating material between a worker and the x-ray tube. The energy of the incident x-ray photon is reduced by Compton and photoelectric interactions in the shielding material. Substances such as lead, that are very dense and have a high atomic number, are very practical shielding materials because of the abundance of atoms and electrons that can interact with the x-ray photon. Shielding is often incorporated into the equipment, such as the metal lining surrounding the x-ray tube. It may also consist of permanent barriers such as concrete and lead walls, leaded glass, and plastic movable screens in the case of analytical x-ray equipment. Radiation Protection: 19 Shielding

This an OLD open beam x-ray diffraction device. New diffraction x-ray devices for research must be contained in an fully shielded – interlocked cabinet. Open Beam Devices 20

The x-ray tube, detector and sample are contained in housing that provides shielding to the user and others in lab. The access doors are interlocked and will shut off x-rays when opened. The large viewing area is made possible by using leaded glass or Plexiglas. XRD Devices 21

A small compact “totally enclosed” research X-ray device. Diffraction cont. 22

Radiography Table 23 This is the mobile shield for the operator. It is designed to protect the operator from scattered x-rays (primarily from patient). This is the control panel. The operator can select x-ray ON (exposure) time in fraction of minutes, the energy of x-ray (in kVp) and current applied (higher current = more x-rays). This is an x-ray tube in a collimated lead housing. The beam is pointed down to the table. The table is where the patient is placed and contains a slot for the film.

When this “C-arm” x-ray device is used the operator and support staff MUST wear a lead apron and whole body dosimeter badge. Fluoroscopic C-arm 24

X-ray devices must be registered with the South Carolina Department of Health, Bureau of Radiation Control. Each x-ray system MUST meet state requirements. Each system must be reviewed by the Radiation Safety Officer (RSO). SC DHEC Regulations 25

If you acquire any x-ray devices you MUST notify the Radiation Safety Officer! Radiation Safety inspects x-ray devices annually. Each system must have a RSO approved radiation protection plan (RPP). X-ray users must be approved by device Principal Investigator. X-ray users need to complete Research X-ray Safety Training course prior to unsupervised use of an x-ray device. X-ray Requirements 26

Operate x-ray device only as specified in manufacturers operating instructions. Notify Radiation Safety Officer of any repairs, modifications, disposal, or relocation of x-ray device. Responsibilities of X-ray Owners & Users 27

All personnel who are likely to receive radiation exposure approaching 10% of the maximum occupational dose limit, and all users of industrial devices shall wear a personnel monitoring device. Whole-body personnel monitoring devices will be worn routinely in the area of the breast pocket, collar, or waist. Pregnant radiation workers shall wear a whole-body personnel monitoring device during the pregnancy. Users of open-beam analytical x-ray equipment are required to wear a whole body and a ring badge Finger ring TLD badges are required for maintenance activities of analytical x-ray equipment that requires presence of the primary beam when any local component in the system is adjusted, disassembled, or removed. Personnel and Area Monitoring Devices 28

Notify the Radiation Safety Officer as soon as her pregnancy is known (confidentiality will be maintained). Limit her exposure to less than 500 mrem during the pregnancy. Wear a whole-body personnel monitoring device during the pregnancy. Keep her exposure to the very lowest practical level by reducing the amount of time spent in a radiation area, increasing the distance from a radiation source, and using shielding. Pregnant Radiation Workers Pregnant radiation workers should: 29

Most analytical x-ray devices do not require users to be issued personnel monitoring devices. X-ray users should address any radiation safety concerns to the Radiation Safety Personnel Monitoring 30

All personnel involved in using a University X-ray device must review this program and will be held accountable for violations. Any PI that may have a research need to purchase, borrow, or build a radiation generating device (X-ray) shall notify the Radiation Safety Officer (RSO). Radiation Safety will inspect x-ray devices and facilities annually. Any changes to an x-ray device (new tube, design modifications, etc.) MUST be approved by the RSO. This x-ray machine will be used as it is currently configured and approved for operation by the RSO. This machine will be operated in accordance with the manufacturers operating and safety procedures. A restricted area will be designated as needed by the RSO to protect personnel against undue risks from exposure to radiation. X-ray device users will be persons authorized by the Principal Investigator and/or RSO. Minors (age less than 18) or members of the general public are not allowed to operate x-ray device without prior approval of the RSO. Members of the public will be considered to be all persons other than those involved in the authorized use, surveillance, or inspection of this machine. Declared pregnant workers may use x-ray after a dosimeter is obtained from the RSO. The dosimeter device shall be worn at all times while using x-ray device. Example of a Radiation Protection Plan (RPP) 31

This completes the training presentation. The link below will direct you to a short quiz to see how much knowledge you retained. If you fail to complete the quiz and registration page your training will not be recorded by Research Safety. If the link does not open please copy and paste the address into a web browser. 32