Electron Beam Analysis (EPMA, SEM-EDS) Warren Straszheim, PhD EPMA, Ames Lab, 227 Wilhelm SEM-EDS, MARL, 23 Town Engineering 515-294-8187.

Slides:



Advertisements
Similar presentations
Instrumental Chemistry
Advertisements

X-ray Detection and Analysis
X-Ray Astronomy Lab X-rays Why look for X-rays? –High temperatures –Atomic lines –Non-thermal processes X-ray detectors X-ray telescopes The Lab.
Saeedeh Ghaffari Nanofabrication Fall 2011 April 15 1.
PROVIDED BY EMAD BEHDAD SPECIALIZED PROTECTION AND CORROSION OF MATERIALS LECTURERS H.MONAJATI,PHD JAFARI,PHD ISLAMIC AZAD UNIVERSITY OF NAJAFABAD BARANCH.
Diffraction of Light Waves
AMCF Materials Characterization School 2012 X-Ray Photoelectron Spectroscopy Tim Morgan.
CHAPTER 9 Beyond Hydrogen Atom
First of all, do you know any methods to check chemical composition? Or how you know what is what? First of all, do you know any methods to check chemical.
Spectrum Identification & Artifacts Peak Identification.
Catalysis and Catalysts - XPS X-Ray Electron Spectroscopy (XPS)  Applications: –catalyst composition –chemical nature of active phase –dispersion of active.
Chemical Analysis with the SEM Qualitative analysis Quantitative analysis Mapping of locations of elements.
Electron Beam MicroAnalysis- Theory and Application Electron Probe MicroAnalysis - (EPMA) X-ray Production: Ionization and Absorption UofO- Geology 619.
X Ray Flouresence Analysis (XRF). XRF X-Ray Fluorescence is used to identify and measure the concentration of elements in a sample X-Ray Fluorescence.
The Origins of X-Rays. The X-Ray Spectrum The X-Ray Spectrum (Changes in Voltage) The characteristic lines are a result of electrons ejecting orbital.
ED and WD X-ray Analysis
X-Ray Microanalysis – Precision and Sensitivity Recall… K-ratio Si = [I SiKα (unknown ) / I SiKα (std.) ] x CF CF relates concentration in std to pure.
Atomic physics PHY232 Remco Zegers Room W109 – cyclotron building
Qualitative, quantitative analysis and “standardless” analysis NON DESTRUCTIVE CHEMICAL ANALYSIS Notes by: Dr Ivan Gržetić, professor University of Belgrade.
NON DESTRUCTIVE CHEMICAL ANALYSIS
Photoelectron Spectroscopy Lecture 7 – instrumental details –Photon sources –Experimental resolution and sensitivity –Electron kinetic energy and resolution.
Thin Film Quantitation of Chemistry and Thickness Using EPMA John Donovan Micro Analytical Facility CAMCOR (Characterization of Advanced Materials in Oregon)
Corpuscular induced and X-ray or γ -ray induced fluorescence NON DESTRUCTIVE CHEMICAL ANALYSIS Notes by: Dr Ivan Gržetić, professor University of Belgrade.
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
Electron probe microanalysis - Scanning Electron Microscopy EPMA - SEM
Common types of spectroscopy
X - Rays & Crystals Characterizing Mineral Chemistry & Structure J.D. Price Characterizing Mineral Chemistry & Structure J.D. Price.
Materials Analysis and Research Laboratory (MARL) Rooms Town Engineering part of the Materials Science and Engineering Department of the College.
Lecture 11b Atomic Physics & Nuclear Reactions Copyright © 2009 Pearson Education, Inc.
Scanning Electron Microscope (SEM) – Shoots a high energy beam of electrons (waves of electrons) at a target. Electron gun Focusing coil Objective lens.
EDS Energy Dispersive Spectroscopy
Unknown at first, these photons from innershell transitions have played a vital role in materials analysis.
Quantitative Analysis Quantitative analysis using the electron microprobe involves measuring the intensities of X-ray lines generated from your unknown.
Electron Microscopes Used to count individual atoms What can electron microscopes tell us? Morphology – Size and shape Topography – Surface features (roughness,
1 Components of Optical Instruments Lecture Silicon Diode Transducers A semiconductor material like silicon can be doped by an element of group.
Scanning Electron Microscope (SEM)
The Quantum Mechanical Atom CHAPTER 8 Chemistry: The Molecular Nature of Matter, 6 th edition By Jesperson, Brady, & Hyslop.
1 My Chapter 28 Lecture. 2 Chapter 28: Quantum Physics Wave-Particle Duality Matter Waves The Electron Microscope The Heisenberg Uncertainty Principle.
Phys 102 – Lecture 26 The quantum numbers and spin.
Chemistry 11 Resource: Chang’s Chemistry, Chapter 7.
Energy-Dispersive X-ray Microanalysis in the TEM Anthony J. Garratt-Reed Neil Rowlands.
Chapter 7 The Quantum-Mechanical Model of the Atom
Atomic Models Scientist studying the atom quickly determined that protons and neutrons are found in the nucleus of an atom. The location and arrangement.
Quantum Mechanical Model of the Atom Quantum Numbers & Electron Configurations.
NANO 225 Micro/NanoFabrication Electron Microscopes 1.
Detection Limits N no longer >> N B at low concentration What value of N-N B can be measured with statistical significance? Liebhafsky limit: Element is.
Reminders for this week Homework #4 Due Wednesday (5/20) Lithography Lab Due Thursday (5/21) Quiz #3 on Thursday (5/21) – In Classroom –Covers Lithography,
SEM- Schematic Overview. Electron Detection Tungsten Filament Electron Source.
SEM Scanning Electron Microscope
Chapter 7 Lecture Lecture Presentation Chapter 7 The Quantum- Mechanical Model of the Atom Sherril Soman Grand Valley State University © 2014 Pearson Education,
X-Ray Microanalysis – Precision and Sensitivity Recall… wt.fraction I = I SiKα (unknown) / I SiKα (pure std.) K-ratio I = [I SiKα (unknown ) / I SiKα (std.)
Page 1 Phys Baski Diffraction Techniques Topic #7: Diffraction Techniques Introductory Material –Wave-like nature of electrons, diffraction/interference.
Electron probe microanalysis Low Voltage SEM Operation Modified 9/23/10.
Chapter 28:Atomic Physics
X-ray microanalysis in the electron microscope
Atomic Physics Quantum Physics 2002 Recommended Reading: Harris Chapter 7.
Comparison b/w light and electron microscopes LIGHT MICROSCOPE ELECTRON MICROSCOPE Magnification can be done upto 2000 times Resolving power is less.
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
X-ray photoelectron spectroscopy (XPS)
Presentation on SEM (Scanning of Electron Microscope) Represented by:-Ravi Kumar Roll:- (BT/ME/1601/006)
Electron probe microanalysis - Scanning Electron Microscopy EPMA - SEM
What is XPS? XPS (x-ray photoelectron spectroscopy) is also known as ESCA (electron spectroscopy for chemical analysis). XPS provides chemical information.
What value of wavelength is associated with the Lyman series for {image} {image} 1. {image}
Electron probe microanalysis EPMA
Electron probe microanalysis - Scanning Electron Microscopy EPMA - SEM
Electron probe microanalysis EPMA
Atomic Absorption Spectroscopy
Electron probe microanalysis - Scanning Electron Microscopy EPMA - SEM
Electron probe microanalysis
Presentation transcript:

Electron Beam Analysis (EPMA, SEM-EDS) Warren Straszheim, PhD EPMA, Ames Lab, 227 Wilhelm SEM-EDS, MARL, 23 Town Engineering With acknowledgements to John Donovan of the University of Oregon

Instrumental Techniques Excite measure characteristic response quantify by comparison to standards

Bulk or microanalysis Can excitation be focused? Can detector be focused?

Electron beam microanalysis Excitation: focused electron beam Sample interactions  secondary electrons  backscattered electrons  auger electrons  cathodoluminescence  absorbed current  X-rays

Precise x-ray intensities High spectral resolution Sub-micron spatial resolution Matrix/standard independent Accurate quantitative chemistry Electron-Sample Interactions

characteristic emissions Be and heavier elements background (bremsstrahlung) X-rays

X-ray Lines - K, L, M K  X-ray is produced due to removal of K shell electron, with L shell electron taking its place. K  occurs in the case where K shell electron is replaced by electron from the M shell. L  X-ray is produced due to removal of L shell electron, replaced by M shell electron. M  X-ray is produced due to removal of M shell electron, replaced by N shell electron.

Ranges and interaction volumes It is useful to have an understanding of the distance traveled by the beam electrons, or the depth of X-ray generation, i.e. specific ranges. For example: If you had a 1 um thick layer of compound AB atop substrate BC, is EPMA of AB possible?

Differences between SEM and EPMA Many shared components Resulting from intent - imaging vs. analysis Stability (higher for EPMA) Current capability (higher for EPMA) Spatial resolution (higher for SEM) via smaller spot and limited aberration correction attached analyzer (EDS vs. WDS)

EDS vs. WDS technology – solid state crystal vs. wavelength spectrometer Resolution~126 eV vs 20eV P/B ratio Detection limit count rate limitations 500 kcps in total vs. 70 kcps/element parallel vs. serial operation

Spectral Resolution WDS provides roughly an order of magnitude higher spectral resolution (sharper peaks) compared with EDS. Plotted here are resolutions of the 3 commonly used crystals, with the x- axis being the characteristic energy of detectable elements. Note that for elements that are detectable by two spectrometers (e.g., Y L  by TAP and PET, V K  by PET and LIF), one of the two crystals will have superior resolution (but lower count rate). Reed, 1995, Fig 13.11, in Williams, Goldstein and Newbury (Fiori volume)

Spectrometer Efficiency The intensity of a WDS spectrometer is a function of the solid angle subtended by the crystal, reflection efficiency, and detector efficiency. Reed (right) compared empirically the efficiency of various crystals vs EDS. However, the curves represent generation efficiency (recall overvoltage) and detection efficiency. Reed, 1996, Fig 4.19, p. 63 Reed suggests that the WDS spectrometer has ~10% the collection efficiency relative to the EDS detector. How to explain the curvature of each crystal’s intensity function? At high Z, the overvoltage is presumably minimized (assuming Reed is using 15 or 20 keV). Low Z equates larger wavelength, and thus higher sin , and thus the crystal is further away from the sample, with a smaller solid angle.

Effect of voltage Excitation volume goes as V 1.7 Available X-ray lines 25kV 5um 15kV 2.5um 10kV 1.3um 5kV 0.4um

Typical steel spectrum, 15 kV

Lines available at low kV Note overlap of V, Cr, Mn, and Fe. Also, O has its line at 0.53 keV.

Effect of current spatial resolution reduced with high currents greater sensitivity with high currents detectability precision/repeatability

Overlap considerations Smaller issue for WDS – effects background choices Deconvolution option for EDS if statistics permit Statistics become problematic if trace element on major element background

EDS Overlap: S, Mo, Hg HgS stdLine TypeWt%Wt% SigmaAtomic % SK series HgM series Total Stoichiometry is on- the-mark - in this case.

WDS “overlap”: HgS, PbS, Mo Note that signal drops to background in between most peaks. Mo tail interferes with S.

Rare earths by EDS and WDS Pr peak fits between Ce L  and L  peaks. Er Dy Tb

EDS Atomic fraction CompoundFeYCePrNdGdTbDyHoErLu D5 Y2Fe B4 Ce2Fe B5 Pr2Fe C1 Nd2Fe C2 Gd2Fe C5 Tb2Fe D1 Dy2Fe D2 Ho2Fe D3 Er2Fe E2 Lu2Fe /19 = 10.53%

Suitable samples solid/rigid stable under beam conductive (while under beam) nonconductive samples can be coated with C or metal (e.g., Au, Pt, Ir) (coating obscures features and elements but only a little)

Samples include Metals Geologic samples Ceramics Poly mers Experimental materials

Quantitative Considerations Homogeneous (within excitation volume) Thick (enclosing interaction volume); therefore, problems with layered samples Known geometry (preferably “flat” compared to excitation volume; thus, polished); therefore problems with rough samples Be smart with construction (e.g., glass vs. Si) Standards collected each time vs. Standardless and normalization

Matrix effects Z-A-F or Phi-Rho-Z corrections accounting for penetration depth, absorption, secondary fluorescence Accuracy depends on well known curvature. Alternatively, need standard in region for better results.

Range of Quantitation 100% down to 0.05% (500 ppm) EDS, 0.001% (10s of ppm) WDS Limited by statistics, differentiation from background More counts help!

Mapping and Line-scans Point analysis are most sensitive to concentration differences (30s/point) Line scans are next (500 ms/pixel) Mapping is least sensitive (12 ms/pixel) Graphics convey much information quickly (i.e., a picture is worth a thousand words)

Digital image showing regions of analysis and line-scan

Mg portion of overlapped peak

Ge portion of overlapped peak

Line-scan using typical windows Ge-Mg overlap causes problems

Line-scan using deconvolution Ge contribution is stripped from Mg profile

Mapping using deconvolution

EDS-WDS comparison

“Harper’s Index” of EPMA 1 nA of beam electrons = coulomb/sec 1 electron’s charge = 1.6x coulomb ergo, 1 nA = electrons/sec Probability that an electron will cause an ionization: 1 in 1000 to 1 in 10,000 ergo, 1 nA of electrons in one second will yield 10 6 ionizations/sec Probability that ionization will yield characteristic X-ray (not Auger electron): 1 in 10 to 4 in 10. ergo, our 1 nA of electrons in 1 second will yield 10 5 x-rays. Probability of detection: for EDS, solid angle < 0.03 (1 in 30). WDS, <0.001 ergo 3000 x-rays/sec detected by EDS, and 100 by WDS. These are for pure elements. For EDS, 10 wt% = 300 X-rays; 1 wt% = 30 x-rays; 0.1 wt % = 3 x-ray/sec. ergo, counting statistics are very important, and we need to get as high count rates as possible within good operating practices. From Lehigh Microscopy Summer School

Raw data needs correction This plot of Fe Ka X- ray intensity data demonstrates why we must correct for matrix effects. Here 3 Fe alloys show distinct variations. Consider the 3 alloys at 40% Fe. X-ray intensity of the Fe-Ni alloy is ~5% higher than for the Fe-Mn, and the Fe-Cr is ~5% lower than the Fe- Mn. Thus, we cannot use the raw X-ray intensity to determine the compositions of the Fe-Ni and Fe-Cr alloys. (Note the hyperbolic functionality of the upper and lower curves)

n = principal quantum number and indicates the electron shell or orbit (n=1=K, n=2=L, n=3=M, n=4=N) of the Bohr model. Number of electrons per shell = 2n 2 l = orbital quantum number of each shell, or orbital angular momentum, values from 0 to n –1 Electrons have spin denoted by the letter s, angular momentum axis spin, restricted to +/- ½ due to magnetic coupling between spin and orbital angular momentum, the total angular momentum is described by j = l + s In a magnetic field the angular momentum takes on specific directions denoted by the quantum number m <= ABS(j) or m = -l… -2, -1, 0, 1, 2 … +l Rules for Allowable Combinations of Quantum Numbers:  The three quantum numbers (n, l, and m) that describe an orbital must be integers.  "n" cannot be zero. "n" = 1, 2, 3, 4...  "l" can be any integer between zero and (n-1), e.g. If n = 4, l can be 0, 1, 2, or 3.  "m" can be any integer between -l and +l. e.g. If l = 2, m can be -2, -1, 0, 1, or 2.  "s" is arbitrarily assigned as +1/2 or –1/2, but for any one subshell (n, l, m combination), there can only be one of each. (1 photon = 1 unit of angular momentum and must be conserved, that is no ½ units, hence “forbidden transitions) No two electrons in an atom can have the same exact set of quantum numbers and therefore the same energy. (Of course if they did, we couldn’t observably differentiate them but that’s how the model works.) One slide Schrödinger Model of the Atom

Origin of X-ray Lines for K and L Transitions