Chemical Process Engineering Laboratory Department of Process and Environmental Engineering Mirjam Karhu, Tiina Leiviskä, & Juha Tanskanen DAF with cationic.

Slides:



Advertisements
Similar presentations
DAF Whitewater Systems
Advertisements

Basic Water Treatment Water Chemistry In order to understand how to best serve a customers needs, a system integrator needs to understand water chemistry.
UAB Ekotakas flocculants
Jar Testing of Chemical Dosages
Characterization of Bare and Surface-Modified Gold Nanoparticles
ANAEROBIC CO-DIGESTION OF ORGANIC FRACTION OF MUNICIPAL SOLID WASTE AND WASTE ACTIVATED SLUDGE AT DIFFERENT RATIOS A. FLOR, L. ARROJA, I. CAPELA Environment.
. Abridged Project Methodology 15 th October 2013 Graham Mann.
Membrane Processes For Waste Water Treatment By: Rohit Chaurasia 3 rd B. Tech. Civil Engineering 71/08.
Nutrient Removal Project: Chemical Phosphorus Removal Jill Crispell, Stephanie Wedekind, Sarah Rosenbaum.
ERIN PARTLAN, DAVID LADNER Clemson University Dissolved CO 2 – An Alternative for Cleaning Inorganic Scale from RO Membranes Acknowledgements Clemson University.
NITRATE REMOVAL BY MODIFIED LIGNOCELLULOSE M.Sc. (Tech.) Anni Keränen, Dr. Tiina Leiviskä, Prof. Osmo Hormi, Prof. Juha Tanskanen University of Oulu, FINLAND.
Surface and Interface Chemistry  Solid/liquid Interface Valentim M. B. Nunes Engineering Unit of IPT 2014.
Dr. Bajnóczy Gábor Tonkó Csilla HIGH OXYGEN DEMANDING TOXIC WASTEWATER BUDAPEST UNIVERSITY OF TECHNOLOGY AND ECONOMICS DEPARTMENT OF CHEMICAL AND ENVIRONMENTAL.
July 29, Bench Top Tests for Surfactant Selection Ayantayo Ajani The University of Tulsa.
Harvesting microalgae (Chlamydomonas reinhardtii) for biofuel production using wastewater treatment techniques By Michael Fuad Need a goals section to.
Industrial wastewater treatment – current research at the University of Oulu (Applied chemistry group) Anne Heponiemi 1, Ville Kuokkanen 1, Hanna Prokkola.
Coagulation in Industrial water Treatment
2.3 Separating the Substances in a Mixture
APPLICATION OF WATER PURIFICATION TECHNOLOGY IN INTENSIVE SHRIMP CULTURE Lai Qiuming 1 *, Yang Yi 2,3, and Qiu Yunhao 1 1.College of Ocean, Hainan University,
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering NRP 2.
Dissolved Air Flotation Introduction Dissolved air flotation Dissolved air flotation (DAF) is a process for the removal of particles/flocs by making the.
Flotation Flotation involves separation of solids from the water phase by attaching the solids to fine air bubbles to decrease the density of the particles.
Reverse Osmosis Lec. 9 Dr. Ola Abdelwahab.
B OILER Presented by: Muhammad Azffar Mohamad Hanif bin Yusof Nor Aminah bt. Mohd Khalil
OZONE DRINKING WATER SYSTEM. CONTENTS Properties of Ozone Production of Ozone Water Treatment Plant – 25 m 3 /hr Ozone Generation System.
PHOSPHORUS REMOVAL FOR LAGOON OPERATORS WHY THE CONCERN OVER P.
Bioseparation Technology
Copyright© by Houghton Mifflin Company. All rights reserved. Chapter 15 Solutions.
ENVE 420 Industrial Pollution Control
Kittima Ngamsai1 Amornchai Arpornwichanop1, 2
Nature of Water. Capillarity: The rising of a liquid in a narrow tube, sometimes called capillary action.
Abstract  Research funded by NSF CMMI  UNH Chemical Engineering Department  Faculty Advisor Professor Xiawei Teng and Dale Barkey  Graduate.
Polymer Nanofibers from Recycling of Waste Expanded Polystyrene Research at The University Of Akron C. Shin and G. G. Chase Polymer Nanofibers from Recycling.
G. Rincon, E. La Motta Civil & Environmental Engineering Kinetics of the Electrocoagulation of Oil and Grease Guillermo J. Rincon, Ph.D. Student Enrique.
PERFORMANCE OF A GRANULAR ACTIVATED CARBON BIOFILTER IN LOW STRENGTH WASTEWATER TREATMENT D. S. Chaudhary, H. H. Ngo and S. Vigneswaran Environmental Engineering.
Advanced Aeration, Inc. Presentation of Vacuum Bubble ® Technology.
Increase of the product recovery of Clostridium acetobutylicum fermentation product by pervaporation P. Izák 1, V. Jarmarová 1,
Cross-border network for knowledge transfer and innovative development in wastewater treatment WATERFRIEND HUSRB/1203/221/196 1st HUSRB Students Meeting.
© Oxford University Press 2011 IC Emulsions Emulsions.
UNIT 8, PART I - SOLUTIONS AND SOLUBILITY. KEY TERMS  Anion - A negatively charged ion  Aqueous Solution - A solution where water is mixed with something.
An efficient biosorption of direct dyes from industrial wastewaters using pretreated sugarcane bagasse.
MAJOR FINDINGS MAJOR FINDINGS  For the same reactor size, bubble size and volumetric flow rate, the bubble column had the lowest vessel dispersion number.
Emma Nikols. How does the efficiency of Bacillus subtilis and Pseudomonas fluorescens biofilters compare when used to prevent soil contamination? This.
Solutions and Mixtures
Hybrid bio-chemical approach for treatment of Industrial Wastewater
What’s new in Water Treatment? Coagulants and Filter Aids Sticky Particles vs. Sticky Media Coagulants and Filter Aids Sticky Particles vs. Sticky Media.
FLOTATION. INTRODUCTION Flotation is an operation that removes not only oil and grease but also suspended solids from wastewaters. Flotation is an operation.
Mechanical Operation Topic : Froth Flotation Techniques & its application in chemical industries Group NO:03 Mayank Chauhan Maunish Mehta.
Dr. Mohab Kamal. CE 445 Water Reclamation and Reuse (Dr. Mohab Kamal) 2.
Surface Tension Measurements of Organic, Inorganic and Mixed Aqueous Solutions Acknowledgments Thanks to the UNH Chemistry Department and Dr. Greenslade’s.
Integration of Accelerated Precipitation Softening - Microfiltration (APS-MF) Assembly to Maximize Water Recovery from the Treatment of Brackish Water.
Degassed Water As a Cleaning Agent ? No Soap Needed Jihee Park.
Water Treatment for Solar Panel Cleaning using Membrane Distillation
SCS Summer School 2017 Past Exam Question Russell Cox.
Advanced Aeration, Inc. Presentation of Vacuum Bubble® Technology
Drinking-water Treatment
Process Performance Improvement Study on DAF
INTRODUCTION  A membrane is a thin semi-permeable barrier which can be used for the following types of separation: 1. Particle-liquid separation 2. Particle-solute.
Polymer Nanofibers from Recycling of Waste Expanded Polystyrene
Dissolved Oxygen and Biochemical Oxygen Demand Analyses
FLOTATION.
Treatment of Simulated Petrochemical Wastewater by Continuous Electrocoagulation/Ultrafiltration Process Presenter: Mahmood Siddiqui.
Refinery: Separation units
Reactor Technology Research Group University of KwaZulu-Natal
Treatment of Produced Fluids:
Jar Testing of Chemical Dosages
ENG421 (8c) – DAF (Sedimentation)
Modification and Testing the Performance of Floor Surface Cleaning Gel
Table (5.1): Particle size found in water treatment
New solutions to treat dairy wastewater
Presentation transcript:

Chemical Process Engineering Laboratory Department of Process and Environmental Engineering Mirjam Karhu, Tiina Leiviskä, & Juha Tanskanen DAF with cationic microbubbles -Treatment of oily waters- References 1.Cheryan & Rajagopalan, Membrane processing of oily streams. Wastewater treatment and waste reduction, J. Membrane Sci. 151 (1998) Okada et al., Effect of surface charges of bubbles and fine particles on air flotation process, Can. J. Chem. Eng. 68 (1990) Henderson et al., Surfactants as bubble surface modifiers in the flotation of algae: dissolved air flotation that utilizes a chemically modified bubble surface, Environ. Sci. Technol. 42 (2008) Henderson et al., The potential for using bubble modification chemicals in dissolved air flotation for algae removal, Separ. Sci. Technol. 44 (2009) Henderson et al., Polymers as bubble surface modifiers in the flotation of algae, Environ. Technol. 31 (2010) Karhu et al., Enhanced DAF in breaking up oil-in-water emulsions, Sep. Purif. Technol., In press. Background Many types of oily wastewaters are produced by various industries. The oil and grease concentration of these wastewaters varies significantly, from 14 even to mg L -1 [1] possessing a huge challenge to their treatment. Dissolved air flotation (DAF) has been a widely used treatment method for oily wastewaters, because it has proved to be reliable and simple treatment method. The microbubbles are produced by dissolving air under pressure and releasing air supersaturated water to the vessel at normal air pressure. These unmodified microbubbles are known to be negatively charged [2]. The electrostatic repulsive force between the oil droplets (negatively charged) and microbubbles could be avoided by modifying the charge of microbubbles to cationic. The treatment of oily waters with modified bubbles, as far as we know, has not been previously published. Henderson et al. [3-5] studied the effect of different chemicals on air bubble charge, and treatment of algae containing water with these modified bubbles. They referred to the process where a positively charged chemical was added into the saturator for bubble modification as PosiDAF. Objectives 1.To study the efficiency of DAF for the treatment of 2 m-% oil-in-water (O/W) emulsions by adding a selected chemical directly into the saturator or by first performing coagulation-flocculation followed by DAF. For comparison PosiDAF with the most potential chemical was also performed on real oily wastewater samples. The performance of DAF was evaluated by measuring chemical oxygen demand (COD), total surface charge (TSC) and with flow cytometry (FCM). 2.The usability of FCM was studied for the determination of hydrophobic particles in O/W emulsions and real oily wastewaters. 3.Study the interaction between microbubbles and PolyDADMAC polymer. 2.Studied chemicals Cationic surfactant CTAB (cetyltrimethylammonium bromide, C 19 H 42 BrN) by Acros Organics. Polymer PolyDADMAC (polydiallyldimethyl- ammonium chloride, the concentration of 40%) by Kemira Oyj. Polymer Epi-DMA (epichlorohydrin-dimethylamine copolymer, the concentration of 50%) by Kemira Oyj. 3.Analyses COD, Hach Lange photometric cuvette test TSC, Mütek PCD 03 pH FCM (samples stained with Nile red), Partec CyFlow ML. 4.DAF set-up The apparatus for DAF studies is presented in Fig. 2. DI- water was first added to the saturator until 10% of the packings was under water. The chemicals were studied by adding them directly to the saturator before pressurizing (5 bar) the vessel or first performing conventional coagulation-flocculation. The DI-water with/without chemical was circulated with a Tapflo diaphragm pump for four hours. DAF flotation studies were then performed. The samples were taken from the bottom of the flotation column 10 minutes after the feed of dispersion water was stopped. Results and Conclusions The COD reductions of O/W emulsions using PosiDAF with PolyDADMAC were higher than for conventional coagulation-flocculation followed by DAF (see Fig. 3). Acknowledgements The authors would like to thank the Graduate School in Chemical Engineering (GSCE), Maa- ja vesitekniikan tuki ry, Finnish Cultural Foundation, KAUTE Foundation and Oulu University Scholarship Foundation for funding the research and Reetaleena Rissanen from CEMIS-Oulu (Finland) for assisting in the FCM measurements. Contact information: P.O. Box 4300, FIN University of Oulu, FINLAND, , Fig. 2. DAF set-up 5.DAF studies I.DAF studies without chemical for treatment of O/W emulsion. II. PosiDAF studies for treatment of O/W emulsions with CTAB, PolyDADMAC and Epi- DMA. Real oily wastewaters with PolyDADMAC. III.Coagulation-flocculation studies for O/W emulsions with CTAB, PolyDADMAC and Epi-DMA were performed by adding the chemical with different stock solution volumes into the column. Flash mixing at 400 rpm (60 s) and slow mixing at 40 rpm (15 min) were performed. Dispersion water was fed to the column after slow mixing. The samples were taken from the bottom of the column 10 minutes after the feed of dispersion water was stopped. IV.The interaction between microbubbles and polymer was studied by performing PosiDAF with PolyDADMAC for pure DI-water and the conventional coagulation-flocculation for PolyDADMAC-water solution. After stopping the dispersion water feed, samples were taken as a function of time from different heights from the column. PosiDAF with PolyDADMAC proved to be more efficient than with Epi-DMA for the treatment of O/W emulsions, probably due to its slightly higher MW. The performance of PosiDAF with PolyDADMAC in the treatment of real oily wastewater was very high; a COD reduction of 70% with an optimal dosage of 200 ppm PolyDADMAC. The performance of PosiDAF using the CTAB surfactant was poor, although better than for coagulation-flocculation with CTAB. The spreading of PolyDADMAC in function of time after feeding of dispersion water was stopped differed between PosiDAF and the conventional coagulation-flocculation.  An indication of cationic bubbles formed in PosiDAF with PolyDADMAC! FCM proved to be a potential analysis method for waters containing oils. PosiDAF proved to be effective treatment method for oily waters containing highly stable O/W emulsions. The article Karhu et al. [6] concerning all the results is in press. Fig. 3. A) COD reductions and B) development of TSC values for DAF studies with PolyDADMAC for O/W emulsions. Experimental 1.Samples 2 m-% synthetic O/W emulsions Real oily wastewaters from a commercial ultrafiltration (UF)-based treatment train (Fig. 1). Fig. 1. Real oily wastewater A) before and B) after UF treatment.