Uninterruptible Power Supplies 1Phase UPS Monitoring System LCD SPT 600 – Series SAMPOONG POWER TECH CO.,LTD. TEL : 02-868-8427 FAX : 02-853-4884.

Slides:



Advertisements
Similar presentations
Zhongxing Telecom Pakistan (Pvt.) Ltd
Advertisements

DAGR Receiver Default Settings
Introducing The IP550 IP Telephone. Things you should know about an IP Telephone system The IPitomy system has many of the same features of traditional.
Smart.IC II project Forklift truck connection Forklift truck connection, outside of the connector Automatic data download through GPRS and anlaysis of.
When the Easy Fridge/Freezer Alarm is plugged into the wall it will ‘boot up’ and display the System Setup Menu Parameter menu will appear where you will.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
Troubleshooting Training Course.  Visual and General Test  Perform System Test (Mode  Perform System Test)  Identify The Error  If you need Technical.
New Horizons Cybersoft Limited. CONTENTS Concept Behind Spot Billing Benefits of SBM(GPRS) GPRS enabled SBM advantages. SBM(GPRS) Billing Process Data.
 Copyright I/O International, 2013 Visit us at: A Feature Within from Sales Rep User Friendly Maintenance – with Zip Code.
University of Maryland Center for Environmental Science Chesapeake Biological Laboratory IP Phone Training.
Data Collection Device (DCD) Job Aid – Burn-in In DOIS Log onto DOIS. Click Options on the DOIS menu bar. Click on Utilities. Click DCD Software Burn-In.
EVOLUTION® Hands-On Demo This guide is meant to help lead a hands-on demo or presentation. The items listed are a suggestion for things to review, please.
Crown DSi Series Control Click the Crown Logo at the top of any the screen to return to this Menu Interactive Main Menu Interactive Front Panel Display.
Quick Operation Guide System Controller WV-CU650 Main Functions (1) WV-CU650 Start Up Login 1. Turn on the power and wait for the Login standby display.
Calibration Procedure.  A winch calibration is completed via a linear interpolation between 2 points.  Requires 2 references  Known lower weight 
PART-2. Access the functions as described. Accessing functions. To change the accessing password, follow the steps below. Use the NEXT key to select:
Proposal 13 HUMAN CENTRIC COMPUTING (COMP106) ASSIGNMENT 2.
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
Confidential Document 1 EverAccess Product Overview By Julian Garcia.
Monitoring systems COMET types MS55 & MS6 MS55/MS6 Configuration.
DC POWER SUPPLY. Maeil Power Co.,Ltd is a one of leading supplier of switching power supply. The company design and manufacture quality products that.
DEMONSTRATION FOR SIGMA DATA ACQUISITION MODULES Tempatron Ltd Data Measurements Division Darwin Close Reading RG2 0TB UK T : +44 (0) F :
1. 2 LXU800 User’s Manual 1.Installation – Windows XP UI Features Introduction Data Connection & Disconnection.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
1 Starting & Stopping Motors Pico Pico LAB#4. 2 Program a series of three basic ladder logic rungs. These basic rungs are the most common rungs found.
Networking All talk - Selective listen Network up to 15 active nodes + 17 passive nodes Nexus/Discovery panels, network repeaters, R3 19” racks, Alarm.
Computer System Examples? Input Output Devices System Unit Devices
Cypress-Fairbanks I.S.D. 04/04/05 PC6 Word Processor Training Assistive Technology
© 2006, ZTE Corporation. All rights reserved.   E300 Series Mini-type Integrated Universal Inverter.
Chapter 5 Basic Input/Output System (BIOS)
Basic Input Output System
DS200 IDEA GENERAL STRUCTURE. PURPOSEPURPOSE The purpose of this presentation is to explain the setup and the use of DS200 IDEA application.
MarsⅡ On-Line UPS Series
SFT 2841 IN CONNECTED MODE Prepare setting files.
• INDEX • CHAPTER 1. Installation • CHAPTER 2. Function introduction
Industrial Process Control System Simon Hui Engineer Control and Informatics, Industrial Centre.
An Introduction to the R3 19 inch Rack The R3 control system comprises a number of different plug in modules, each of which is dedicated to a particular.
RSG (Remote Service Gateway). 1. Overview  Overview The LDK-RSG (LDK-Remote Services Gateway) is a remote gateway that provides a fully transparent connection.
Model 1621M Trainer’s Guide. General Overview Model 1621M is a Geiger Meuller based Personal Radiation Detector (PRD) Complies with ANSI Used for.
RPTCS Automatic Transfer Control System Low and Medium Voltage Power Transfer Control.
Business Enabled Communications Hotel Feature. Contents Room Swapping Maid Status Register Hotel Name Set Call Forward Guest Name/Info Display Dial One.
Page 1 March 2007 CheckSource 2.3 Portable Power Phantom Load.
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
Introducing The IP550 IP Telephone. What to expect from your new IPitomy IP telephone system The IPitomy system has many of the same features of traditional.
CA Operator Console Communication Assistant Version4.
© 2007 Ideal Industries 1 of 32 Intro To Ideal 800 Power Analyzer Basics of IDEAL Industries 800 Series Power Analyzer.
TECHNICAL TRAINING SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB.
1 April 29, 1999 ZENO DATALOGGER Texas Natural Resource Conservation Commission.
ResponseCard XR User Data. Press the MENU button ResponseCard XR.
ResponseCard XR User Data Version 1.0 ®. Press the MENU button. ResponseCard XR.
Chapter 14 - Configuring Shutdown and Power Management Options.
Asttraining.com Scan Procedures for Ford EEC-V OBD II Systems.
Basic Input/Output System (BIOS). 5.1Introduction to BIOS Basic Input / Output System (BIOS) boot the computer by providing a basic set of instructions.
1 High Level Design Phase Refining Use Cases User Interface Information.
SmartMQn Motor Horner APG, LLC September 9, 2008.
Office of Housing Choice Voucher Program Voucher Management System – VMS Version Released October 2011.
Service Section Technical Training December 2005.
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
Confidential Document 1 EverAccess Product Overview By Rodney Guinto.
How to Use the Mitel Your Phone SoftKeys: Keys that allow you to choose between different options on the screen HardKeys: Keys that need to be pushed.
How to Use the Mitel Your Phone SoftKeys: Keys that allow you to choose between different options on the screen HardKeys: Keys that need to be pushed.
Puissant Panel User Training Esc.. 09:11:35 ACTIVE # * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
1 Top Level of CSC DCS UI 2nd PRIORITY ERRORS 3rd PRIORITY ERRORS LV Primary - MaratonsHV Primary 1 st PRIORITY ERRORS CSC_COOLING CSC_GAS CSC – Any Single.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
KM SERIES VENDING MACHINES OPERATION MANUAL. ARM Main board & Driver Board DRIVING BOARD MAIN BOARD.
CMV-NET Chigo VRF Network Centralized Control System
Guest Sessions LRS UK Offices –
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Presentation transcript:

Uninterruptible Power Supplies 1Phase UPS Monitoring System LCD SPT 600 – Series SAMPOONG POWER TECH CO.,LTD. TEL : FAX :

Table of Contents 1. Display Screens 2. Display Configuration 3. Display Screen 3-1 Initializing Screen 3-2 Top Screen 3-3 Measurement 3-4 Power History 3-5 Event History 3-6 Meter Setup 3-7 Time & Date Setup 3-8 Sys Information 3-9 Comm. Setup 3-10 Pager Number Setup 3-11 Comm. Monitoring 4. Events

1.Introduction It describes the use and the operation of 1Ph. UPS Monitoring System. That is, the system is designed to obtain its necessary information from analyzing the data on LCD monitor. And, the system explains the method how to set the information and operate the directional keys. 2.Display Configuration Initializing Screen TOP Screen MeasurementPower HistoryEvent HistoryMeter Setup Time&Date Setup Comm.Setup System information Pager Number Setup Comm. Monitoring # Display Configuration indicates all functional configurations of UPS Monitoring System. # It shows the correlation between each function: the measurement status of UPS, system status, alarm and system status histories, data, all settings, and etc. # Initialized screen a displaying screen a beginning of system's activation w/ input power. # Main menu screen shows main menu. # When select a menu thru the directional keys and press the 'Enter’ key, you will see the desirous screen and the operation of the functions in the screen.

3.Display Screen It describes the output mode from the screen showing all the functions of 1Ph. Monitoring System and the method of the key-pad in those cases. The order of the screen is from the initializing screen to the main menu and to the showing of it. The setting and operation is to be complete if you press the 'Enter' key after selecting a menu on each function. And if you press the 'Cancel' or 'ESC' key, you can cancel the setting or return to the previous steps and the initializing screen. 3-1Initializing Screen 2001/12/01 15:00:00 > System Normal Load Percent=00.0 Reset a CPU board while pressing an 'Alarm Stop' and a 'Buzzer Stop' key in the case of installing a board on a system for the first time or there is a change. And, you had better re-set everything after resetting the CPU board once again while pressing the 'Execute'/'Enter' key on the initializing screen. Date & Time is displayed even with second. If the time is not displayed or can not be controlled, it indicates that the operation of UPS Controller would be abnormal. Therefore, you should check and fix it. If it is displayed incorrectly, refer to the section of 3-7, Time & Date Setting. UPS mode indicates one out of 'System Normal', 'System Bypass', and 'System Battery' modes according to the system status. Load Percent ’ indicates a current load-efficiency down to one decimal place.

3-2.TOP Screen (ON)UP (OFF)DOWN RFLF 경보 내역 ESCENTER 경보 정지 ENABLE 계측 [Main Menu] 1.Measurement 2.Power History 3.Event History 4.Meter Setup 5.Time & Date Setup 6.Sys Information 7.Comm. Setup 8.Pager Number Setup 9.Comm. Monitoring It is displaying a main menu. If you press any key on an initializing screen, the monitor is showing the top screen. The menu displays three lines on a screen from the second line to the fourth line. And, 9 menus in three lines except a title are displayed with the 'Scroll Lock' key, 〈 UP 〉 / 〈 DOWN 〉. "←" is displayed at the last part of the currently selected line. Therefore, it indicates the position of a current cursor and performs a selected function when the 'Enter' key is pressed. For the more detailed information about the functions, refer to the describing screen of each function.

3-3 Measurement Screen [Measurement] INP 220V 110A 60HZ OUT 220V 100A 60HZ BAT 216V TEMP 23 ℃ If you press the measurement of operating panel, you can easily go into a current menu. Each measured value is the value which applies "a Calculated Changing Average" to each one and calculates it after reading the value of adapter. Hence, they do not immediately point the rapid change of it out and just follow the effortful method for the reliability of it according to noise levels. There would be the case which needs about 10s to direct a new valid value because of the change of it. Displaying Monitor is: Input: Voltage/ Current/ Frequency Output: Voltage/ Current/ Frequency Battery:Voltage and UPS Temperature

3-4 Power History Screen [Measurement] INP 220V 110A 60HZ OUT 220V 100A 60HZ BAT 216V TEMP 23 ℃ [Power History] / 12 / 01 11:30:30 INP 220V 110A 60HZ OUT 220V 100A 60HZ It is the screen which resumes the periodically stored data of the measured value from a UPS Monitoring System. You can refer to the change of the measured value because it periodically records Input Voltage/ Current/ Frequency and Output Voltage/ Current/ Frequency. And, it can help you analyze a cause by resuming the 'Event History' and the 'Power History' of the time when events happen. It can record max. 100 histories and they are orderly overwrote from the old ones. 3-5 Event History Screen [Event History] 100 CODE=[17] ADR= / 12 / 01 11:30:30 SYSTEM BYPASS It records histories to an appropriate 'Event History' when a particular alarm is monitored in UPS Monitoring Controller. The recorded histories are used as information for after-service and etc. It can be recorded max. 100 histories and orderly overwrote from the old ones. If you press the 'Alarm History' key, you can return to a current menu so easily.

3-6 Meter Setup Screen [Meter Setup] INP 220V 110A 60HZ OUT 220V 100A 60HZ BAT 216V TEMP 23 ℃ It is a function used only by manufactures. (Consumers must not use it.) It is a functional screen setting the standard of measured value. 3-7 Time & Date Setup Screen It is a functional screen resetting time and date when they are inputted incorrectly. [Time & Date Setup] 2001 / 12 / 01 11:30: / 12 / 17 15:20:40 CURRENT TIME & DATE COMPLETE TIME FOR SETTING When the 'Enter' key is pressed after setting time & date thru the left/right key of operating panel, a new time & date can be reset.

3-8 System Information Screen [System Information] Model No : Max Load : KVA It is a function used only by manufactures (Consumers must not use it.). It is a screen setting the model ID and capacity of system. 3-9 Communication Setup Screen [Communication Setup] PROTOCOL:SMART-MON CONNECT:DIRECT ONLY SPEED : bps There are three kinds in protocol as a communicating method. They are: SMART-MON, MEGA-TEC, POWER-WISE. 'SPEED', baud speed, is one out of 38400bps, 19200bps, and 2400bps and it is determined by protocol. You must press the 'Enter' key to complete a setting after determining a communicating method.

3-10 Pager Number Setup Screen [Pager Number Setup] Phone No : 018xxxxxxx////yyyy y///2//#s It is a screen setting receiver's telephone no. or pager no. when some particular events (alarms) are monitored. 'Number 0' indicates the telephone no. of the PC which is connected to modem and activates a monitoring program. 'Number 1' and 'Number 2' indicates pager/PCS phone no. Setting for Number 0: Computer-use Only ex.1) : when setting the telephone no. like ex.2) 9, : when setting the telephone no. like using a switchboard connected to outside with a no. 9. Setting for Number 1 and Number 2: Pager or PCS phone-use Only 1. Pager: Input the phone # orderly while hanging it on. Just input appropriate no. of '/' between #s as much as a waiting time. ex.) ///2# → when the response of pager's co. says "Press 2 for paging" after setting the no. like (in the case of no.1 for recording and no. 2 for paging). 2. PCS phone: This case is more complicated a little bit. At first, the paging function has to be provided by the PCS supplier. That is, there has to be a message-managing center and user must know the no. (As a reference, input 0018 instead of 018 as a telephone office no.). ex.) //// //2/# : Input the no. of message center like 0088→018 on each telephone office no. ////: A waiting time for phonetic information at the step //2: The paging code for phonetic information, “Standby for a while “, ”no. 2 for paging” #: Means ‘Complete’

3-11 Comm. Monitor Screen [Comm. Monitor] It is a screen monitoring the status of interface in system. This function is used only by the engineers who check the interface in system.