5.3 Installing the blade server in a BladeCenter unit.

Slides:



Advertisements
Similar presentations
Laptop Usage & Care Asad M. Nafees. Inserting a Battery Pack To insert a battery pack into the battery bay: 1. Turn the notebook upside down on a flat.
Advertisements

Data Projector Setting Up/Connecting Laptop & Data Projector.
Presenting A Power Point Program. Computer Checklist Computer Checklist Power Cord Mouse Computer.
C3 confidentiality classificationIntegrated M2M Terminals Introduction Vodafone MachineLink 3G v1.0 1 Vodafone MachineLink 3G LED status display and operation.
Networking By: Matt Motl… Programmer Brent Everson… Programming Mentor.
PowerEdge M-Series CMC Management
SGI Confidential Copan 400 Installation. SGI Confidential Installation Overview The approximate minimum time to complete this procedure is.
How to Perform Preventive Maintenance of the Personal Computer Properly Shut Down of the Computer Properly Shut Down of the Computer Unplug all Connection.
Tool removed during cycle Fault #2 Conditions for setting Tool cocked prox switch goes open during cycle AND force on load cell drops below limit in fault.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
United States Army Combined Arms Center Troubleshooting TBC Workstation.
How to Build A Computer By John A. Saiz. Materials Required Tools Screw driver Screw driver Tweezers Tweezers Flashlight FlashlightHardware PC Case PC.
SGI Confidential Platform Service Manager. SGI Confidential PSM Front Chassis View Two 2.0 USB Ports, one of which connects to the front chassis.
COMPREHENSIVE Windows Tutorial 10 Improving Your Computer’s Performance.
CCNA 2 v3.1 Module 2.
Module 8 Installation & Setup M1000e Chassis
AccuMax Multi-Point Injection Mechanics
Module 10 PS M4110 Components. Module Objectives: Describe the indicators on the front panel of the PS-4110 array Demonstrate how to replace a Disk Drive,
Hands-On Microsoft Windows Server 2008 Chapter 11 Server and Network Monitoring.
CH 13 Server and Network Monitoring. Hands-On Microsoft Windows Server Objectives Understand the importance of server monitoring Monitor server.
Windows Server 2008 Chapter 11 Last Update
®® Microsoft Windows 7 Windows Tutorial 10 Improving Your Computer’s Performance.
1 Semester 2 Module 2 Introduction to Routers Yuda college of business James Chen
Troubleshooting Computers in the FHC. Hardware Issues Computer will not turn on – Check power cable – Check power strip Computer is on, but screen is.
April WebEx Intel ® Active Management Technology (AMT) LANDesk Provisioning LANDesk Server Manager.
Trouble shooting and Managing system. Computer is running slow what steps needed? Reboot Free hard drive space Verify that there is at least MB.
Ch. 5 – Access Points. Overview Access Point Connection.
Ch 11 Managing System Reliability and Availability 1.
A+ Guide to Managing and Maintaining Your PC Fifth Edition Chapter 5 The Motherboard.
Administering Windows 7 Lesson 11. Objectives Troubleshoot Windows 7 Use remote access technologies Troubleshoot installation and startup issues Understand.
®® Microsoft Windows 7 for Power Users Tutorial 8 Troubleshooting Windows 7.
Hands-On Microsoft Windows Server 2008
Module 6 – Switch Configuration CCNA 3 Cabrillo College.
1 © 2003, Cisco Systems, Inc. All rights reserved. CCNA 3 v3.0 Module 6 Switch Configuration Cisco Networking Academy.
CH 6 Configuring Server Hardware and power options.
Microsoft ® Official Course Module 10 Optimizing and Maintaining Windows ® 8 Client Computers.
Operating Systems  A collection of programs that  Coordinates computer usage among users  Manages computer resources  Handle Common Tasks.
C ONFUSED, F RUSTRATED, C OME OVER AND SEE US AT THE HELP DESK. We can help you with this and much, much more.
Ch. 6 – Switch Configuration
GCS 300 System Operation Application – Level 1.
Balancer Operation Intelift Operation Installation Troubleshooting Preventive Maintenance Preventive Maintenance OVERVIEW.
Troubleshooting Windows Vista Lesson 11. Skills Matrix Technology SkillObjective DomainObjective # Troubleshooting Installation and Startup Issues Troubleshoot.
Ch.2 – Introduction to Routers
Basic MAC Troubleshooting. Kernal Panic Error A kernel panic during startup can have many possible causes, including: Hardware Devices Corrupted file.
5.3 HS22 Install Specifics. Removing the blade server cover If the blade server is installed in a BladeCenter unit, remove it (see Removing the blade.
PREVENTIVE COMPUTER MAINTENANCE. Preventive Maintenance regular and systematic inspection, cleaning, and replacement of worn parts, materials, and systems.
Ch.2 – Introduction to Routers CCNA 2 version 3.0 Rick Graziani Cabrillo College.
Introduction to Routers
Charging Cart Instruction & User Manual EnTrans Technology Co., Ltd.
Troubleshooting Windows Vista Lesson 11. Skills Matrix Technology SkillObjective DomainObjective # Troubleshooting Installation and Startup Issues Troubleshoot.
5.3 More troubleshooting. Exercise 1 A temperature increase within seconds after powering up the blade server. 2.
/Reimage-Repair-Tool/ /u/6/b/ /channel/UCo47kkB-idAA-IMJSp0p7tQ /alexwaston14/reimage-system-repair/
Unit Hardware Troubleshooting
Chapter Objectives In this chapter, you will learn:
How to power down your NAS safely
Fujitsu Training Documentation Hardware Installation
Fujitsu Training Documentation Hardware Installation
K TO 12 CHS MODULE FOR GRADE 9, PP
How to Create Mac OS X Recovery Partition?
Intro and T1 Troubleshooting
How to Resolve Blue Screen Error Display on your HP Computer?
Call to Fix Canon Pixma MX340 printer Error 5200
Press ESC for Startup Options © Microsoft Corporation.
PHASE IDENTIFICATION UNIT (PIU)
How to Perform Preventive Maintenance of the Personal Computer
The Troubleshooting theory
KX-NS Step by Step Guide Initial Setup
Presentation transcript:

5.3 Installing the blade server in a BladeCenter unit

Installing blade server 2

Select the blade bay for the blade server; at least one blade bay is required. When any blade server or device is in blade bay 7 through 14, power modules must be installed in all four power-module bays. If you are reinstalling a blade server that you removed, you must install it in the same blade bay from which you removed it. Some blade server configuration information and update options are established according to blade server bay number. Reinstalling a blade server into a different blade server bay number from the one which it was removed can have unintended consequences, and you might have to reconfigure the blade server. 3

Installing blade server To help ensure proper cooling, performance, and system reliability, make sure that each blade bay on the front of the BladeCenter unit contains a blade server, expansion unit, or blade filler. Do not operate a BladeCenter unit for more than 1 minute without a blade server, expansion unit, or blade filler in each blade bay. 4

Installing blade server Make sure that the release handles on the blade server are in the open position (perpendicular to the blade server). Slide the blade server into the blade bay until it stops. Push the release handles on the front of the blade server to the closed position. 5

Installing blade server After the blade server is installed, the service processor in the blade server initializes and synchronizes with the management module. This process takes approximately two minutes to complete. The power-on LED flashes rapidly, and the power-control button on the blade server does not respond until this process is complete. Turn on the blade server 6

Turn on the blade server (1) After you connect the blade server to power through the BladeCenter unit, the blade server can start in any of the following ways: –You can press the power-control button on the front of the blade server to start the blade server Let’s talk about the Blade server controls and LEDs 7

Blade server controls and LEDs The following illustration identifies the buttons and information LEDs on the blade-server control panel. 8

Blade server controls and LEDs Each blade server contains a front panel LEDs that helps determine if the server is operating properly as well as indicate any errors that occur: Blade-error or Fault LED: This LED is also known as the blade system-error LED. When this amber LED is lit, it indicates that a system error has occurred in the blade server. The blade error LED will turn off only after the error is corrected. 9

Blade server controls and LEDs Information LED: When this amber LED is lit, it indicates that information about a system error for the blade server has been placed in the management module event log. Location LED: When this blue LED is on, it has been turned on in response to a programmed condition, or remotely by the system administrator, to aid in blade identification for maintenance. The location LED on the BladeCenter chassis will be illuminated as well. Turn off the location LED after maintenance is complete. Blade-activity LED: When this green LED is lit, it indicates that there is activity on the hard disk drive or network. 10

Blade server controls and LEDs Power-on LED: While the BladeCenter chassis has AC power, this green LED turns on in blinking mode and stays on when you power on your blade server. When the blade is first inserted, the LED will blink at a high frequency because the blade is being “discovered” by the Management Module (MM) at this time. As soon as the MM has logged the blade’s presence, it will decrease the frequency of the blinking, allowing for the power switch to function. 11

Blade server controls and LEDs Wait until the power-on LED on the blade server flashes slowly before you press the power-control button. While the service processor in the blade server is initializing and synchronizing with the management module, the power-on LED flashes rapidly, and the power-control button on the blade server does not respond. This process can take approximately two minutes after the blade server has been installed. While the blade server is starting, the power-on LED on the front of the blade server is lit and does not flash. 12

Turn on the blade server (2) If a power failure occurs, the BladeCenter unit and the blade server can be configured to start automatically when power is restored through the Advanced Management Module 13

Turn on the blade server (3) You can turn on the blade server remotely by using the management module. 14

Turn on the blade server (4) If the blade server is connected to power (the power-on LED is flashing slowly), the blade server is communicating with the management module, the operating system supports the Wake on LAN feature, and the Wake on LAN feature has not been disabled through the management module, the Wake on LAN feature can turn on the blade server. 15

Installing blade server continued Write identifying information on one of the labels that come with the blade servers and place the label on the BladeCenter unit bezel Do not place the label on the blade server or in any way block the ventilation holes on the blade server. 16

Installing blade server continued If this is the initial installation of the blade server in the BladeCenter unit, you must configure the blade server through the Setup utility and install the blade server operating system If you have changed the configuration of the blade server or if you are installing a different blade server from the one that you removed, you must configure the blade server through the Setup utility, and you might have to install the blade server operating system. 17

Some issues that can happen with Installation hen you are diagnosing a problem in the BladeCenter unit, you must determine if the problem is in the BladeCenter unit, one of the BladeCenter modules, or in a blade server. If the BladeCenter unit contains more than one blade server and only one of the blade servers has the problem, troubleshoot the blade server that has the problem. If all of the blade servers have the same symptom, it is probably a BladeCenter unit or module problem. 18

Exercise 1 A blade server power-on LED flashes rapidly for an extended amount of time. –Identify the reasons 19

Exercise 2 You installed a new blade server in, a blower module is running at full speed. –Identify the reasons 20

Exercise 3 A blower module is not working. 21

Exercise 4 A fan pack is running at full speed. 22

Exercise 5 An I/O module will not turn on. 23

Exercise 6 Cannot communicate with the external ports on an I/O module. 24

Exercise 7 The keyboard, mouse, or pointing device is not working. 25

Exercise 8 The keyboard, mouse or pointing device does not work after switching ownership of the KVM to a different blade server. 26

27