1 Fujitsu Training Documentation Hardware Installation
Hardware Installation ETERNUS DX Entry S4 ETERNUS DX60 S4, DX100 S4 and DX200 S4 Hardware Installation Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017 Copyright Fujitsu, Release June 2017

2 Fujitsu Training Documentation
Hardware Installation ETERNUS DX Entry S4 Content Rack Mounting Power Cabling Backend Cabling QSFP Power On Procedure Power Off Procedures Operator Panel - Function Button Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017 Copyright Fujitsu, Release June 2017

3 Fujitsu Training Documentation
Rack Mounting Hardware Installation ETERNUS DX Entry S4 Fit the Controller Enclosure and/or Drive Enclosure to the rack For more and detailed information use the Hardware Installation Guide for the ETERNUS DX Entry S4; inp-R14B EN1) For better stability installation of hardware in a rack has to start from the bottom Always have tilt prevention in place when installing HD-DE Make sure in advance that the maximum load capacity of the raised floor construction is not exceeded when installing High Density Drive Enclosures (that can be extremely heavy when fully populated) Controller Enclosure: maximum 54 kg Drive Enclosure: maximum 35 kg HD Drive Enclosure: maximum 95 kg 1) At the end of the file name 01 refers to first released version and EN refers to language variant English Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017 Copyright Fujitsu, Release June 2017

4 Fujitsu Training Documentation
Power Cabling Hardware Installation ETERNUS DX Entry S4 For FTS (CEMEA&I) only Connect the rack PDUs (Power Distribution Units) to independent AC power phases Make sure that the AC power switches on each Enclosure are turned off before connecting their power cables Connect each Power Supply of an Enclosure to different Power Distribution Units Left Rack PDU Right Rack PDU PSU#0 inlet PSU#1 inlet Always follow the local power cabling regulations! PSU#0 inlet PSU#1 inlet Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017 Copyright Fujitsu, Release June 2017

5 Backend Cabling QSFP (1)
Fujitsu Training Documentation Backend Cabling QSFP (1) Hardware Installation ETERNUS DX Entry S4 Reverse cabling Cabling runs in ascending order from CM#0 towards IOM#0 Connect SAS (OUT) port with SAS (IN) port Cabling runs in descending order from IOM#1 towards CM#01 IN OUT IN OUT Drive Enclosure# 02 IN OUT IN OUT Drive Enclosure #01 Controller Enclosure Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017 Copyright Fujitsu, Release June 2017

6 Backend Cabling QSFP (2)
Fujitsu Training Documentation Backend Cabling QSFP (2) Hardware Installation ETERNUS DX Entry S4 Follow the SAS port labels at the Enclosures This will point to the correct cabling This sign means "IN" and this sign means "OUT" Connect the cables according the labels showing the direction Cable end marked with plug into Enclosure connector marked with SAS ports of the Controller Enclosure always have the type "OUT" QSFP Cable Is a twin-cable with a Mini SAS connector at its end The cable has a blue release tab that must be applied when removing the cable from the connector Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017 Copyright Fujitsu, Release June 2017

7 Backend Cabling QSFP (3)
Fujitsu Training Documentation Backend Cabling QSFP (3) Hardware Installation ETERNUS DX Entry S4 Extra care need to be taken when connecting the SAS cables between CM and DE MiniSAS connectors have a very poor mechanism for preventing the connector to be connected wrong way around Therefor cable and Jack are colored labeled Cable tab side to match with the blue color of the receptacle Pink color coding for the other side of the cable and receptacle Incorrectly connected cable leads not only to malfunction but can potentially damage also The built-in MiniSAS electronics of the cable The SAS electronics within the CM or IOM Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017 Copyright Fujitsu, Release June 2017

8 Backend Cabling QSFP (5)
Fujitsu Training Documentation Backend Cabling QSFP (5) Hardware Installation ETERNUS DX Entry S4 DE expansion of an ETERNUS DX S4 system (1) Disconnect the SAS cable CM#1  IOM#1 (2) Connect the SAS cable CM#1(OUT) to IOM#1(IN) of the last, new DE (3) Connect the SAS cable IOM#1(OUT) of the last, new DE to the previous DE IOM#1(IN) During the expansion procedure ETERNUS DX S4 is fully functional accessing the HDDs of the existing DEs via the SAS backend cabling path CM#0 to IOM#0 CM DE#01 Rack#1 CM DE#01 DE#02 Rack#1 CM DE#01 DE#02 DE#03 Rack#1 Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017 Copyright Fujitsu, Release June 2017

9 DE Expansion between Racks
Fujitsu Training Documentation DE Expansion between Racks Hardware Installation ETERNUS DX Entry S4 Following QSFP cable lengths are available For direct connections and for reverse cabling between DEs as well as between two racks in 2.5 m, 3.5 m and 6 m With DX Entry S4 systems maximum 10 DEs can be added to the CE DE#07 Rack#1 Rack#2 DE#06 DE#05 DE#04 DE#03 DE#02 DE#0A DE#01 DE#09 CM DE#08 Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017 Copyright Fujitsu, Release June 2017

10 DE Expansion between Racks
Fujitsu Training Documentation DE Expansion between Racks Hardware Installation ETERNUS DX Entry S4 Flexible installation into customer's environment It is possible to locate enclosures/racks up to 30m away from each other For DX100 S3/S4 and DX200 S3/S4 Cable length with 15 m and 30 m is available Active Optical Cable (AOC) SAS-3 allows DE to be installed in different areas No need to secure extra space for future expansion Different floors 2nd floor Line 1 Line 2 Line 3 Possible to install up to two rows away from each other Possible to install into a faraway rack ~ 1st floor Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017 Copyright Fujitsu, Release June 2017

11 Advantage of Reverse QSFP Cabling
Fujitsu Training Documentation Advantage of Reverse QSFP Cabling Hardware Installation ETERNUS DX Entry S4 In the extremely rare case of a complete DE failure all HDDs remain accessible in all surviving DEs Rack#1 Rack#2 DE#07 DE#06 DE#05 No longer accessible DE#04 DE#03 DE#02 DE#0A DE#01 DE#09 CM DE#08 Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017 Copyright Fujitsu, Release June 2017

12 Single / Dual Controller Update
Fujitsu Training Documentation Single / Dual Controller Update Hardware Installation ETERNUS DX Entry S4 A single CM configuration is allowed to be upgraded to a dual CM configuration in the field Also the Drive Enclosure need to be upgraded Note the reverse QSFP cabling of the IOM#1 expansion Single CM Dual CM CE CE CM#0 CA CA CM#0 CA CA CM#1 CA CA DE#01 DE#01 IOM IOM IOM DE#02 DE#02 IOM IOM IOM CA: Channel Adapter IOM: IO module DE: Device Enclosure 1 CM to 2 CM upgrade parts Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017 Copyright Fujitsu, Release June 2017

13 DX Entry S4 HD-DE Expansion
Fujitsu Training Documentation DX Entry S4 HD-DE Expansion Hardware Installation ETERNUS DX Entry S4 Maximum number of HD-DEs DX100 S4 2 HD-DEs when the total number of HDDs does not exceed 144 DX200 S4 4 HD-DEs when the total number of HDDs does not exceed 264 Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017 Copyright Fujitsu, Release June 2017

14 Fujitsu Training Documentation
Power On Procedure (1) Hardware Installation ETERNUS DX Entry S4 The ETERNUS DX S4 systems can be Powered On directly from the Controller Enclosure Push the Power Switch The Power Switch of the CE lights green The power on sequence takes about 2 minutes If everything is OK, the green Ready sign in the CE and the green Power LED in the DE switch on ID Fault Power ID Power Ready Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017 Copyright Fujitsu, Release June 2017

15 Fujitsu Training Documentation
Power On Procedure (2) Hardware Installation ETERNUS DX Entry S4 Controller Enclosure LEDs POWER SWITCH with integrated LED Constant green when the power is turned on READY LED Constant green when device is available for use FAULT LED Constant amber when a failure is detected in the ETERNUS DX system Blinks in amber when a component which requires preventive maintenance is detected MAINT LED Constant green when the system has its status set to Maintenance IDENTITY LED Constant blue when locate functionality is enabled by the GUI or CLI CACHE LED Constant green when data exists in cache memory Blinks in green when cached data is saved to the flash memory Power switch Power indicator Fault Identify Maintenance Cache Ready Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017 Copyright Fujitsu, Release June 2017

16 Power On Procedure (3) Drive Enclosure LEDs
Identical for 2.5" and 3.5" DE Identify LED Constant blue when locate functionality is enabled by the GUI or CLI Power LED The Drive Enclosure is operating normally and was switched on by the CM ID (7-segment) Shows a 2-digit Drive Enclosure ID First digit is the SAS bus number The DX Entry S4 systems always show bus no. "0" Second digit is the DE number for example "01" = DE#1, "02" = DE#2… "0A" = DE#10 Is assigned automatically by the SAS backend cabling during the Add DE procedure DE ID Identify Fault Power Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017

17 Fujitsu Training Documentation
Power Off Procedure Hardware Installation ETERNUS DX Entry S4 Verify with the customer that all server I/O is stopped Also confirm that the "Cache" LED in the Operator Panel is off Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will shutdown all Enclosures gracefully In case of moving ETERNUS to a new location, you naturally have also to disconnect the AC power cords from the PDUs after the system is powered off Make sure the Cache LED of the Controller Enclosure is off Power switch Cache Ready Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017 Copyright Fujitsu, Release June 2017

18 Operator Panel - Function Button (1)
Fujitsu Training Documentation Operator Panel - Function Button (1) Hardware Installation ETERNUS DX Entry S4 Remove the plastic left hand side Flange Cover to get access to the Function Button Function Button is located next to the Maintenance (MNT) LED The Operator Panel for the 2.5" and 3.5" CE has the same appearance Use the pin tool to operate one of the following functions See next slide for further details Enable / disable Maintenance Mode Change CM Master association Initializing network settings back to factory default values for MNT and RMT port Initializing factory DX local user accounts Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017 Copyright Fujitsu, Release June 2017

19 Operator Panel - Function Button (2)
Fujitsu Training Documentation Operator Panel - Function Button (2) Hardware Installation ETERNUS DX Entry S4 The operation can be performed by carrying out the following steps1) To toggle the system status between "Maintenance" and "Normal" Keep the Function Button pushed for three seconds The MNT LED lights green when the system is in Maintenance mode The MNT LED is off when the system is in Normal mode Switch the functionality of Master CM to the other Controller Module (1) Switch on "Maintenance Mode" (2) Push down the Function Button twice within three seconds The Master LED lights green to indicate the Master CM (3) Switch off "Maintenance Mode" 1) With DX Entry S4 the RMT port is designated for maintenance purposes Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017 Copyright Fujitsu, Release June 2017

20 Operator Panel - Function Button (3)
Fujitsu Training Documentation Operator Panel - Function Button (3) Hardware Installation ETERNUS DX Entry S4 Initializing network settings back to factory default values for MNT and RMT port of the CM1) (1) Switch on "Maintenance Mode" (2) Push down the Function Button three times within three seconds The MNT LED blinks green for a few seconds (3) Switch off "Maintenance Mode" Attention In parallel the network settings of the MNT port are completely removed Master-IP-Address and Netmask Slave-IP-Address and Netmask Primary and Secondary DNS-IP-Addresses Wake-on-LAN disabled List of allowed IP-Addresses Make always a note about the above MNT network settings 1) With DX Entry S4 the RMT port is designated for maintenance purposes Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017 Copyright Fujitsu, Release June 2017

21 Operator Panel - Function Button (4)
Fujitsu Training Documentation Operator Panel - Function Button (4) Hardware Installation ETERNUS DX Entry S4 Initializing factory DX local user accounts The operation can be performed by carrying out the following steps Initialization to the factory user accounts ''root'' and ''f.ce'' with default settings (1) Switch on "Maintenance Mode" (2) All management LAN ports (FST and MNT) must be unplugged (3) Push down the Function Button ''Function'' five times within three seconds The Master LED lights green to indicate the Master CM (4) Switch off "Maintenance Mode" Attention Other created local user accounts are deleted, too Make always a note about the user accounts and its settings Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017 Copyright Fujitsu, Release June 2017

22 Fujitsu Training Documentation
Hardware Installation ETERNUS DX Entry S4 Copyright Fujitsu, Release June 2017