Connecting to industry. Fittings for Steam Hose Remember Steam is……… minimum 212 F.

Slides:



Advertisements
Similar presentations
Special Mines Services An Employee Owned Company.
Advertisements

The idea evolved from two different contractor customers who shared with us a better way to perform hydrostatic testing of DWV piping system. Two different,
Fasteners Mr. Lombardi. Fasteners Mr. Lombardi.
Low Pressure Motor Valves. Single Acting Motor Valve Single soft seat Tight shut-off Full line size opening Removable valve seat Optional opening assist.
 Established in 1995  Located in Wilmington, NC with a 40,000 Sqft facility.  Specializes in the design and manufacturing of connection solutions. 
© 2012 Delmar, Cengage Learning Automotive Plumbing: Tubing and Pipe Chapter 24.
PVC Pipe Cutter Plumbing Tools And Supplies-Plumbing Tools and Supplies Image: PVC_Cutter.jpg Height: 250 Width: 250 This cutter makes smooth clean.
Aerospace Fastener Applications
Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.
SAFE PROPANE TORCH USAGE
1 UBC International Training Fund Presents. Tensioning.
3 rd Harmonic He Vessel Welding Helium Vessel-to-Cavity No June 2008.
Trouble Shooting How to Recognize Improper Installation May 2009 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages Tubing.
The Swagelok® SK series and AFS Multipurpose Ball Valves
PAPER ROCKET LAUCNHER Bob Galliher Hobart Middle School 705 e.4 th St. Hobart, In
Finally, a compressed air piping system so simple…it’s EZ!
© 2005 Swagelok Company, The Swagelok ® 40G Series One-Piece Instrumentation Ball Valves.
DISTILLATION Imelyn will show you how to set up for distillation. Scroll down.
1 Hose and Lines. 2 High side / low side System with an expansion valve High SideLow Side Condenser Evaporator Receiver/Drier Compressor Expansion valve.
External nut type series 43
New Mexico FFA Agricultural Mechanics Career Development Event Plumbing.
For the interconnection of pneumatic components and systems
Compressed Air Piping Systems by Asahi/America
Connecting to industry. Swivels Dixon Valve & Coupling Company manufactures Swivel Joints that are intended for piping applications. Be sure to contact.
Drilling Machine Accessories
WPP-Fasteners & Hardware
Please follow in manual AC CHAPTER 7
FASTENERS.
INSTALLATION & COMMISSIONING. 5WSS Installation Hanging the Unit Hanging the Unit Location Considerations Location Considerations Refrigerant Piping Refrigerant.
EMISSION PROBE PARTS TUBE: 3/8” OD x wall Stainless Steel Length determined by pipe diameter and placement of connecting end to allow easy connection.
5535K41Polypropylene Cam-and- Groove Hose Coupling Plug, 1-1/2 Coupling SizeIn stock at $2.53 Each.
825, 825Y, 825YD 21/2”-10”. Modification Overview  825- ( ) Cast iron body- Threaded in seats- Internal check parts are epoxy coated iron. Old.
994 2½ ”- 10”. Modification Overview  Production for the 994 began in 1999 and is current.
Sockets, Ratchets, and Impacts Speed Wrench - Available in 1/4”, 3/8”, 1/2” Drives.
Connecting to industry. Hose Coupling Safety It is important to fully inspect the overall hose assembly both prior to installation, and also after the.
Connecting to industry. Purpose of Presentation A Avoid, or at least reduce liability through education & communication. D Dealing with maximum working.
1 HVACR316 - Piping Copper Tubing and Fittings. 2 2 Safety Refrigerant cylinders should be stored and transported in the upright position to keep the.
LF866 2½”-10”. Product Overview  Production of the 2½” – 10” sizes began in  The LF866 utilizes a Type 2 bypass (Model LF619 single check).
Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -
Fabrication of Fishtank Reservoir ENGR 121 living with the lab.
Model 12 Intek Horizontal OHV
4D-200, 4D-700 2½”- 10”. Modification Overview  Production began in 2003 and was discontinued in  The 4D-700 (RPDA) uses a Type-II bypass (single.
Sealing the Engine Walla Walla Community College Automotive Technology.
Welcome! Drafting 2323: Pipe Drafting Andrew Amini Full Time Instructor, HCC.
Rapid Change Technology The following is a presentation to aid Technicians in the replacement of the Rapid Change Technology Block.
Mechanical Joint Restraints
Connecting to industry. Hose Coupling Safety The cover of a hose is intended to protect the reinforcement members. If the protective cover is compromised,
Pipe specials.
Automotive Heating And Air Conditioning
Overview Hose Assembly PRECISION MACHINING Fitting Manufacturing
310 Series Inline End Suction
Air Pak Drying Systems Presented By: Dry Air Systems, Inc. Innovator of Unique Regenerative Desiccant Air Dryers For Compressed Air & Fluid Power Controls,
Reverse Engineering Air Regulator By: Sean Paras and Lloyd Evans.
Fastener Facts Fastener Facts.
Swivels. Swivels Dixon Valve & Coupling Company manufactures Swivel Joints that are intended for piping applications . Be sure to contact Dixon prior.
Automotive Engines Theory and Servicing
LHC IRQ Tie Bar Redesign Using Sleeves – Preliminary
Fastener Facts Fastener Facts.
Industrial Skills Fasteners & Hardware.
Conductivity Sensor Fabrication
MACH 112: Cutting Tools & Measurement
THE SKINNER COMPANY Product Review
REFLUX Dan will show you how to set up a reaction under refluxing conditions. Scroll down.
Measure Hose as 14”, 12.5”, 12.25”, 9” & cut it.
SPARK-DUTY™ L – C L A M P S.
For the interconnection of pneumatic components and systems
Welcome! Drafting 2323: Pipe Drafting
GENERALPIPINGREQUIREMENTS:. Designing and erecting an efficient piping system requires certain aspects/ requirements which could be found in our PME handbook…
Automotive Engines Theory and Servicing
Presentation transcript:

Connecting to industry

Fittings for Steam Hose

Remember Steam is……… minimum 212 F

DPL Catalog Information in the back of the catalog Direct relationship between pressure and temperature of saturated steam.

The RMA (Rubber Manufacturers Association) Has designated Steam the most potentially dangerous of all materials that is handled through a hose assembly. As such, it carries a Safety Requirement Factor of 10 to 1.

Dixon …… in keeping with the RMA’s recommended Safety Factors, has approved for Steam Service, only a handful of products for use with Steam Hose.

WARNING ……. NEVER use any Dixon fitting, or accessory item for Steam Service unless Dixon Valve & Coupling Company has expressly approved it for such service !

The Boss System for steam service

The Boss System Available from ¼” through 6” Available from ¼” through 6” Good for up to 450 degrees F Good for up to 450 degrees F Available in Steel, Iron, Stainless Steel, and Brass. Available in Steel, Iron, Stainless Steel, and Brass.

Boss Male Stems 1” ID & smaller is machined bar stock steel with standard barbed stem. 1 ¼” ID & larger is cast iron with “Cor-O-Zig” impression shank.

Boss Male Stems Male NPT Thread Boss Clamping Collar Heavy Duty Hex Nut

Boss Washer Style Female Flat surface on spud Flat Washer Flat surface on hose stem Clamp collar

Boss Female Ground Joint Rounded seat in spud Rounded head on hose stem Boss clamping collar

LP Boss Male Stem Boss Hose Mender Double Spud Washer Male Spud Female Spud Wing Nut Cap Female Adapter Male Adapter Boss Accessories for steam service

Cold Flow … … is a phenomena related to rubber (elastomers). Rubber moves away from points of stress! Pressure and heat intensify the Cold Flow movement. Since steam presents both pressure as well as heat, it becomes very important in choosing the proper means of clamping the assembly.

Boss Clamps Nuts & Bolts to retighten the clamp as needed. Gripping fingers to engage Boss collar on hose stem Multi-section design for “even” take-up

Clamp fingers properly engage fitting Boss clamping collar. Clamp sections do not touch …. plenty of room for adjustment. Warning label installed.

Clamp fingers “bottomed out” on neck of fitting. Clamp sections touching each other. No warning label

Boss Clamps Torque values on the nuts & bolts of the Boss clamps will vary by size. Torque values in Foot Pounds can be found in the Boss Clamp section of the Dixon DPL Catalog.

DPL Catalog Boss Section Information can be found for both clamp sizing, and for torque ratings on nuts & bolts. Hose ID size Hose OD range Torque

STEAM Quick Disconnects WARNING: Do not disconnect under pressure

STEAM Quick Disconnects Rated to a maximum of 100 psi saturated steam (338 degrees F). Rated to a maximum of 100 psi saturated steam (338 degrees F). Spring loaded safety shut-off valve in both the plug and the coupler. Spring loaded safety shut-off valve in both the plug and the coupler. Large gripping collar on sleeve of the coupler for ease of handling with gloves on. Large gripping collar on sleeve of the coupler for ease of handling with gloves on. Available ¼” through 1 ½” sizes. Available ¼” through 1 ½” sizes.

STEAM Quick Disconnects are Female NPT threaded ….. In order to be properly used in Steam Service they must be threaded onto a “Boss” male that has been secured in the hose with a “Boss” clamp !

STEAM Quick Disconnects In order to properly drain a steam hose assembly that has valve type fittings, you have two options available: Allow media to completely cool. Completely remove the valved Quick Disconnects and drain the water. Allow media to completely cool. Completely remove the valved Quick Disconnects and drain the water. Allow media to completely cool. Insert a spare plug into the coupler end of the assembly, and roll the hose towards the open end to drain the water. Allow media to completely cool. Insert a spare plug into the coupler end of the assembly, and roll the hose towards the open end to drain the water.

Are there any questions?