Use of the Inhalant Anesthetic Machines

Slides:



Advertisements
Similar presentations
Engineer Training XL1200 Pneumatics. Engineer Training XL1200 Pneumatics Confidential 2 Working Concept Overview: The Pneumatic System is comprised of:
Advertisements

CO₂ Euthanasia Procedure October AVMA Guidelines for the Euthanasia of Animals: 2013 Edition Small Laboratory rodents: mouse, rat, hamster, gerbil,
ANESTHETIC MACHINES.
Operating Nitrox Systems 11 Presented by Nuvair. Operating Nitrox Systems2 Membrane systems produce nitrox efficiently Compressed air flows through the.
Anesthesia Machine Presented by Gil Soto C.R.N.A.
1 FUEL SYSTEM SERVICE ENGINE CLEAN FUEL TOOL MODEL RX 777.
Anesthesia Apparatus Checkout Recommendations
Penny For your Thoughts
1 DIESEL FUEL TOOL ON VEHICLE DIESEL FUEL SYSTEM SERVICE MODEL Rx HD 888 INSIDE FILTER.
3.7.4 Student Book © 2004 Propane Education & Research CouncilPage Identifying Testing Procedures for Anhydrous Ammonia (NH3) Contamination Because.
Oxy-fuel Welding and Cutting By: John Templeton
Andrew Brock. Terms  The burning qualities of gases are used in Ag Mechanics to heat, weld and cut metals  Weld- to join by fusion  Fusion- melting.
Terms and Definitions Base Metal: Metal to be welded Fusion Welding: process that joins metals by heating them to a melting point and allowing them to.
Scavenging System  To reduce exposure to waste anesthetic gases  Can be active or passive scavenging system Active Scavenging System  Connected to a.
Nitric Oxide Set-up for Patients on Ventilator
Quick Reference Guide to Proper Isoflurane Handling and Use EXPOSURE LIMITS: NIOSH recommends an exposure level of 2 parts per million (ppm) that should.
AccuMax Single Point Injection Operation (See Installation and Operation Manual for detailed instructions)
Dennis Sabre Fire Appliances
 The annular space. The clearance between the head of the float and the flow tube is known as the annular space.
Case Study: Controlling exposure to isoflurane used in animal surgical procedures in Research & Development Michel Vangeel, Janssen Campus Belgium IOHA.
By Dr. Ahmed Mostafa Assist. Prof. of anesthesia and I.C.U.
PART 3: Breathing Circuit
2001, 2002 & 3012 Series Operation 2001, 2002 & 3012 Series Operation (See Installation and Operation Manual for detailed instructions)
Parts of the Anesthetic Machine
Emergency Oxygen Assembly and Administration By Alexa Keenan Assembling and Administering Emergency Oxygen.
AccuMax Multi-Point Injection Mechanics
Sand media filtration is one of the oldest filter processes in the world. Water Tool Modular Filters have made extensive improvements to what is presently.
Scavenging System A&A Pg 356  To reduce exposure to waste anesthetic gases  Can be active or passive scavenging system Active Scavenging System  Connected.
Series Operational Training. 2 Water Tank Water Pump Multiple Discharges 2000 Series Line Strainer Foam Tank Electronic Direct Injection Proportioner.
+ Surgical Procedures 7.01 Implement techniques to prepare and monitor patients for surgery.
Aseptic Technique University of North Texas Health Science Center
Oxy Fuel Welding Basic Setup & Use
Settings & Adjustments. Settings & Adjustments.
Without reference, identify principles about Anesthesia Units with at least 70 percent accuracy.
SHOP SPEED DATE Get to know your work place. #1: MSDS A Material Safety Data Sheet (MSDS) is a document that contains information on the potential hazards.
Anesthetic Record Positioning Your Patient Recovering Your Patient.
PART 3: Breathing Circuit
Faxing 101: Using the Fax Machine (and yes, we have a fax machine!) How to use a calling card for a long-distance number:
Engineer Training Pneumatic System Overview. Engineer Training Confidential 2 Working Concept Overview: The Pneumatic System is comprised of:  Y Pistons.
VNTE Prep Anesthetic Review.
IBEX 2011 Boat Fuel Systems: Boat Fuel Systems: Complying with the New Regulations and Standards Common Pitfalls of Integrating the Evaporate Emission.
Oxyacetylene Cutting O.A.C. Pattern Cutter Cutting Torch.
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
Response to Anesthetic Problems and Emergencies We are going to talk about your response to:  Depth of anesthesia issues  Cardiac arrest  Recovery period.
Reptile Anesthesia.  Injectable and inhalant anesthetics are commonly employed both for surgery and sedation for diagnostic or treatment procedures.
XAS 375 CD6 Compressors Committed to sustainable productivity
Parts of the Anesthetic Machine A&A Pages
PART 3: Breathing Circuit
Oxy-Fuel Welding. What is Oxy-Fuel Welding? Process the fuses metal together Does not require electricity Uses a torch and filler rod Similar equipment.
How to Fill Vapor Liquid in Electronic CigarettesVapor Liquid Electronic cigarette liquid Electronic cigarette liquid is what fills up electronic cigarette.
Anesthesia. Preparation Removal of food and water is recommended for 12 hours prior to surgery Supplemental heat is also used to maintain the patient.
SAFE WORK PRACTICES IN AGRICULTURAL MECHANICS AG MECH II.
STEP 1 Locate the transmission cooler line connection on the vehicle. Identify the correct adapters to be used by referring to the vehicle application.
Fire Fighter Safety SCBA CHANGE/REFILL
HOME EMERGENCY GUIDE TAUFIQ ABDULLAH,MD EMERGENCY MEDICINE FACULTY OF MEDICINE, UNIVERSITY OF BRAWIJAYA EMERGENCY DEPARTMENT OF SAIFUL ANWAR HOSPITAL TAUFIQ.
BREATHING SYSTEMS.
Compressed Air Foam System
Director, Product and Strategic Development VetEquip, Inc.
Basics of Medical Equipment Lecture 5
Veterinary Anesthesia
PART 3: Breathing System Parts
MACHINE OPERATION.
MACS CPAP System Self Guided Tour.
Non-Rebreathing System
Respiratory Protection Training
Reptile Anesthesia.
Parts of the Anesthetic Machine Parts 1 & 2: A&A pages
SB Packing Automatic Downpuller Power Unit
Non-Rebreathing System
Concorp, Inc. - Respiratory Protection Training. Revision – B
Presentation transcript:

Use of the Inhalant Anesthetic Machines

STEP 1 Hook Up Fair canister/scavenger to Anesthesia machine and Induction chamber

STEP 2 Check level of isoflurane in the vaporizer and fill to full mark if needed. This is done by removing cap of fill valve and adding isoflurane to the full line. Fill out LASC order Forms for Isoflurane.

Vaporizer is used to mix the inhalant anesthetic and the oxygen.

STEP 3 Turn on Oxygen Tank to supply O2 to mix with inhalant anesthetic.

A way to measure oxygen flow from the tank of Oxygen to the Vaporizer Turn on the oxygen to the system by turning the knob at the bottom of the oxygen gauge (the metal ball will move) to the desired liters of oxygen flow per minute; 1.0-2.0 liters is an appropriate flow range.

For Induction Should be performed in the Hood for your Safety Turn the dial of the vaporizer to 4-5% Place animal in the chamber which has had paper-towels placed in it. Close cover of the chamber Watch the respiration of the animal.

For Induction: Turn vaporizor to 4 or 5% Watch animal respiration!!

For Maintenance Place a paper-towel where the animal will be laying _ Adjust the vaporizer concentration to about 2.5% Place a paper-towel where the animal will be laying Move animal to this surface and place into nosecone Monitor respiration, either increasing or decreasing the percentage of isoflurane as needed. If necessary, use the “flush” button to give 100 % oxygen. Use toe pinch, tail pinch and/or eye reflex to test for depth of anesthesia.

Rat with Nose Cone If animal has irregular breathing patterns or mucous membranes turns blue (cyanosis), Turn off Isoflurane and administer only Oxygen.

At End of Procedure Turn off the isoflurane Turn off the O2 Tank Press the O2 flush button to give the animal a flush of oxygen to speed recovery and to release pressure within the system. Place animal back in its cage During recovery set cage on a circulating heating pad, or comparable system. Monitor until it has regained sternal recumbancy