On-line Glucose Measurement in Disposable Bioreactors Michael Hartlep and Wolfgang Künnecke INTRODUCTION The use of disposables in biopharmaceutical processes.

Slides:



Advertisements
Similar presentations
OFFLINE COMPOSITION MEASURING SENSORS
Advertisements

Diffusion Through a Membrane State Lab
EEE 529 Microsystems Amperometric Biosensors
ProMinent Product Overview
IC Controls 855 & 802 ppm Dissolved Oxygen System pH / ORP Conductivity Dissolved Oxygen Chlorine Standards R1.0 © 2004 IC CONTROLS.
King Saud University Riyadh Saudi Arabia Dr. Gihan Gawish Assistant Professor 1.
3-D reconstructions based on electron micrographs of isolated mitochondria taken with a large depth of field, at different tilt angles have indicated.
Chapter 10 Control Loop Troubleshooting. Overall Course Objectives Develop the skills necessary to function as an industrial process control engineer.
Microfluidic Glucose Sensor Senior Design Group 4 Kristen Jevsevar Jason McGill Sean Mercado Rebecca Tarrant Advisor: Dr. John Wikswo, Dr. David Cliffel.
Fabrication of a Microelectrode Array Biosensor Based on a Modified Enzyme-Chitosan Biocomposite Lorenzo D’Amico October 1, 2008.
Dr. Marc Madou, UCI, Winter 2012 Class V Potentiometric and Amperometric Sensors (I) Electrochemistry MAE-295.
E. Gorbova, A. Volkov, A. Chuikin, A. Efremov OBJECTIVES: 1.To study the characteristics of amperometric sensors, for measuring hydrogen content in humid.
Amperometric Biosensors. Introduction Enzyme Catalyzed redox reactions The function of the enzyme is to generate or consume an electroactive species in.
DO NOW How can muscle cells maintain (or keep) a high concentration of potassium inside the cell? If a cell increases or decreases in volume, what type.
© Copyright 2002 ABB. All rights reserved. - Microelectromechanical Systems for Process Analytics IFPAC 2003 Dr. Berthold Andres ABB Automation Products.
David M. Struve, SFWMD, Meifang Zhou, SFWMD, Tom Baber, Litkenhaus Associates ABSTRACT A remote P analyzer has been designed and optimized using UV/thermal.
IC Controls 865 ppb Dissolved Oxygen System pH / ORP Conductivity Dissolved Oxygen Chlorine Standards ppb Galvanic Dissolved Oxygen.
WORKING PRINCIPLE OF DO AND pH PROBE Prepared by: Tan See Yean Yuganesh a/l Murugiah Jelita Bungin Nazzira Md Zin.
Oxygen transfer in bioreactors
Sensor Systems for CPI Sensor Transmitter temperature sensors
Growth curves of micro-organisms. Learning Objectives  Discuss the growth curves of micro organisms  Outline the differences between batch and continuous.
Fermentation Kinetics of Yeast Growth and Production
Measurement of KLa It is extremely difficult to measure both ’KL‘ and 'a' in a fermentation and, therefore, the two terms are generally combined in the.
BY ROBERT ELDER MENTOR: DR. ADAM HIGGINS Development of a Device to Measure Cell Membrane Water Permeability.
The VANASYL Bags Vanasyl LLC.. Areas for Bag Technology Applications  Bioreactor sampling  Bioreactor additions (antifoam etc.)  Media/buffer prep.
R. Shanthini 26 Feb 2010 Source: Microbial Fuel Cells.
Reaction Engineering.
Pretreatment Application of Ligninolytic Enzymes Faculty Sponsor: Dr. Christine Kelly School of CBEE Group Members: Uranbileg Daalkhaijav, Faraz Ebrahimi,
Microfluidics Technology Fair, October 3, 2006 Parallel Integrated Bioreactor Arrays for Bioprocess Development Harry Lee, Paolo Boccazzi, Rajeev Ram,
PPT 206 Instrumentation, Measurement and Control SEM 2 (2012/2013) Dr. Hayder Kh. Q. Ali 1.
1 BVT Presentation 2012 RNDr. Jan KREJČÍ, PhD., Chief of executive board.
Sensor Technology Soil Moisture Sensor -By Amrit Gautam (TI13S1) A soil water sensor is an instrument which, when placed in a soil for period of time,
D ESCRIBE THE BIOREACTOR PARAMETERS AND HOW TO CONTROL THE TEMPERATURE.
1. Blood or Fluid Analysis Using carried out in central labs with problems of time delay costs and potential misslabeling Drive toward more bedside or.
Minibioreactors -> Volumes below 100 ml Characterized by: -> area of application -> mass transfer -> mixing characteristics.
Chapter 17 Corrosion and Degradation of Materials.
Electrochemical Science and Technology: Fundamentals and Applications, Keith B. Oldham, Jan C. Myland and Alan M. Bond. © 2011 John Wiley & Sons, Ltd.
PTT 202 ORGANIC CHEMISTRY FOR BIOTECHNOLOGY Lecture 4: Electroanalytical Methods Zulkarnain Mohamed Idris Semester /2014.
Topic 02: Microbial Oxygen Uptake Kinetics
Oxygen Permeation Measurements Across Films using OxySense® luminescence Technology Devinder Saini OxySense Inc S. Eastern Ave Suite 14G Las Vegas,
Water toxicity detection through perfusion and monitoring of living cells on a microfluidic chip Fang Li, Ph.D. Department of Mechanical Engineering New.
BIOFABRICATION OF MEA GLUCOSE SENSORS Dry in air Ready for in vitro glucose detection (B) Chitosan biopolymer is electrodeposited on target electrode sites;
Free Residual Chlorine Measurement
Biochemical instrumental analysis-14
Dedicated Analytical Solutions Near-Infrared Spectroscopy as a Process Analytical Technology in the Biotech Industry Presented to the Advisory Committee.
© SSER Ltd..
Process Control of Esterification in a NeSSI-Based Micro-Reactor by Raman Spectroscopy Stuart Farquharson, Chetan Shende, Frank Inscore, and Wayne Smith.
Microfluidic Glucose Sensor Senior Design Group 4
1 Tom Edgar’s Contribution to Model Reduction as an introduction to Global Sensitivity Analysis Procedure Accounting for Effect of Available Experimental.
Microbial growth in:- Closed Cultivation Systems Open Cultivation Systems Semi-Open Cultivation Systems.
Development of Microfluidic Glucose Sensors BME 273: Kristen Jevsevar, Jason McGill, Sean Mercado, Rebecca Tarrant Advisors: Jennifer Merritt, Dr. John.
Commercial Use of Enzymes
Microfluidic Glucose Sensor Senior Design Group 4 Kristen Jevsevar Jason McGill Sean Mercado Rebecca Tarrant.
A WIRELESS PASSIVE SENSOR FOR TEMPERATURE COMPENSATED REMOTE PH MONITORING IEEE SENSORS JOURNAL VOLUME 13, NO.6, JUNE 2013 WEN-TSAI SUNG, YAO-CHI HSU Ching-Hong.
KAU-Faculty of Science- Biochemistry department Analytical biochemistry lab (Bioc 343) 2012 T.A Nouf Alshareef
Date of download: 7/7/2016 Copyright © ASME. All rights reserved. From: Liquid Metal Ink Enabled Rapid Prototyping of Electrochemical Sensor for Wireless.
Introduction Lei, Yang; Luo, Ning. A highly sensitive electrochemical biosensor based on zinc oxide nanotetrapods for L-lactic acid detection. Nanoscale,
Measuring device to test completely installed insulated rail joints safely and contactless with direct resistance indication.
Bioreactor Basics Mini-BIOMAN, July 2017.
Scale of Fermentation process:- Large Scale, Small Scale & Pilot Scale Fermentation Presented by: Neha Agrawal m.sc. 3rd sem.
Electrochemistry MAE-212
Cell-based biosensors
Proposed Oxygen Concentration Monitoring System of Food Packaging
BIOELECTRONICS 1 Lec4: Calorimetric Biosensor
Instrumentation and Process Control
Bioreactors Engineering
Kinetic Studies on Enzyme-Catalyzed Reactions: Oxidation of Glucose, Decomposition of Hydrogen Peroxide and Their Combination  Zhimin Tao, Ryan A. Raffel,
4. Basis Operations in Food Fermentations (Biotechnology)
Topic 02: Microbial Oxygen Uptake Kinetics
Growth curves of micro-organisms
Presentation transcript:

On-line Glucose Measurement in Disposable Bioreactors Michael Hartlep and Wolfgang Künnecke INTRODUCTION The use of disposables in biopharmaceutical processes has increased significantly during the last few years, both for improved performance and for the economic advantages they offer. However, there is a need for additional sensors that will enable the disposable process to be integrated in compliance with the latest Process Analytical Technologies. TRACE on-line analyzers are well established for continuous process monitoring in conventional bioreactors connected via rugged sterile filtration and dialysis probes, respectively. For disposable bioreactors a new dialysis probe was designed and characterized in connection with a novel single-use bioreactor system. Disposable Sampling Based upon the patented dialysis sampling technique a special single-use plug for disposable bioreactors was constructed as continuous sampling device. A cellulose- acetate-membrane is fixed inside the plug (picture below). The membrane acts as a sterile barrier and is used for the separation of the analytes of interest. The dialysis plug is installed at the bottom side and sterilized together with the disposable bag. Analytical performance The linearity of the measurements was proven by changing the concentrations of glucose and lactate inside the bag. The results of linearity are shown in figures below. TRACE C2 on-line analyzer TRACE C2 is a dual-channel on-line analyzer. The substances glucose and lactate can be detected continuously. The analyzer was specially developed for cell culture fermentations and disposable technologies. The range of glucose concentration is 0.01 – 10 g/L and the frequency is 30 measurements per hour. The internal temperature correction coefficient makes a temperature range from 15°C to 30°C possible. Platzhalter für Zeilenabstand The detection is performed using a combination of an enzymatic reaction with an amperometric detection. Glucose is converted via glucose oxidase to gluconolactone and hydrogen peroxide. This is measured at a platinum electrode. The biosensors have life time of 5000 measurements or 21 days. Online-Glucose measurement in batch fermentation of E.coli in a bag fermenter The disposable bioreactor is placed inside the CELLtainer system from CELLution. Sterile medium and glucose solution (30 g/L) are filled into the bag under sterile conditions. The tubing of the dialysis plug is connected to the TRACE analyzer. The bag is shaken with the CELLtainer system (see picture below). The TRACE analyzer was calibrated and the continuous on-line measurement of glucose started. The disposable bioreactor was inoculated with E.coli cells. After a lag-period of several hours the cells start to consume glucose (blue line in figure below). At the same time the dissolved oxygen level inside the medium decreased (red line in figure below). After eleven hours of cultivation glucose was completely consumed and the dissolved oxygen increased again. Acknowledgements The authors would like to thank the European Union and the BMBF for supporting this project (Eurotransbio, proposal no. ETB , reference no ). TRACE Analytics GmbH Richard-Wagner-Straße Braunschweig (Germany) CONCLUSION Disposable on-line sensing of glucose and lactate using a single-use sampling probe can be provided with similar performance compared to conventional PAT systems. This probe can be custom made for different bioreactor designs and special applications. During an E.coli fermentation it was demonstrated that the dynamics of glucose consumption can be reliably monitored with the TRACE C2 analyzer under real conditions.  Safe and economic operations  Low installation size and less maintenance effort  Simultaneous assay of glucose and lactate  Especially suitable for cell cultures  Sterile consumables (tubing set, sensor and transport solution)  Disposable biosensors with long-term stability and low drift  External sensor unit to be placed directly at the process  No sample volume required  Connection to different fermenter and single-use reactors Nico Oosterhuis CELLution Biotech BV Dr. A.F. Philipsweg 15A 9403 AC Assen (The Netherlands)