Windows When assessing window area consider the whole dwelling (windows, glazed doors and roof lights), including any extensions (but not conservatories).

Slides:



Advertisements
Similar presentations
Loft Conversions - The building regulations Chris Wigley MD London Building Control Ltd
Advertisements

Grimsby Secondary School
Hot Water Systems.
Land Victoria Suggested changes to the Subdivision (Procedure) Regs 2000 Disclaimer The content of this Land Victoria presentation is provided for information.
East Bridgford Project Existing Projects The Green Box Project Adaptation Techniques used within this project:- Natural ventilation is increased by a passive.
eQuest Quick Energy Simulation Tool
Q5- U-Value 2010 HL 5. (a) Calculate the U-value of an uninsulated external solid concrete wall of a dwelling house built in the 1950s given the following.
Building Energy Rating
Domestic GDA Training – Annex A Methodology for Amendments…1Training Material © Stroma Certification 2012 | Version 1.0 ABBE Level 3 Diploma in Domestic.
Walls Ron Gatepain constructionsite.
© Stroma Development Ltd 2013 | Version 1.1 Stroma – insulation Insulation Wall insulation Cavity wall insulation / Solid wall insulation Roof insulation.
Chapter 14 Floor-Plan Symbols.
Property Elements In this section we will look at the different Property Elements and how to identify and assess them.
1 Thermography of Buildings Stacey Ward - BSRIA Instrument Solutions - - Sales Manager -
1 ISAT Module III: Building Energy Efficiency Topic 6:Stead-State Building Loads z Fabric Loss z Ventilation Loss z Environmental Temperature z Steady-State.
HEAT LOSS If the conservatory is not heated from the main heating system or it has an external quality door fitted i.e. double glazed patio or similar.
Building Australia’s Future Energy Efficiency Introductory Awareness Training AUSTRALIAN Greenhouse Office Supported by: Step by Step Application of BCA.
FOR SALE 45 Sharow Grove Blackpool FY1 5NE 290 Church Street Blackpool Lancs FY1 3QA Fax: (01253)
After the foundations have been completed the walls are set out and construction commences. wall structures.
Hard to Treat Homes Bev Coombe Membership and Communications Manager.
© PDST Home Economics Heating and Insulation. Methods of Heating Central heating: heat created by burning fuel (solid, oil, gas) in a boiler in a central.
Evidence on Tackling Hard to Treat Properties Prof. Sue Roaf, Heriot-Watt University Dr. Keith Baker, SISTech Ltd Andrew Peacock, Heriot-Watt University.
Introduction to Nest- Care & Repair Caseworkers’ Forum February 2012.
What do the letters show?. Homework Explain how solar panels can be used to heat buildings and water.
Inside Housing Solutions Ltd South Barn, Cowix Farm, Capel Road, Rusper, West Sussex RH12 4PY Tel: Energy.
Energy Conservation within walls. Energy conservation Energy cannot be created or destroyed but can simply be changed from one form to another. The more.
P1a 1.5 Heat transfer by design. Lesson Objectives To investigate factors that affect the rate of thermal energy transfer. To describe how thermal energy.
© Warwick University 2005 Session 6 Introduction to the worked examples.
Conserving Energy. Types of Insulation Loose-Fill: cellulose fibers, fiberglass fibers, rockwool fiber - sprayed into spaces Batt and Blanket: layers.
Windows and Doors. Typically once the roofing material has been installed/completed the windows and doors are installed. It’s important to install these.
Energy – domestic greenhouse gas emissions emissions from the domestic housing sector represent about 30% of the total Space heating 53% Water heating.
RdSAP principles.
EDT Elevations1 Weekend Cabin Retreat Project Elevations Sacramento City College EDT 300/ENGR 306.
RSAP+ from Stroma You should have installed RSAP+ on your laptops, and we will use this for the exercise. Other software is available, we do not recommend.
Critique 3 Adam Boney, Fraser Cassels, Marc Breslin and Nick Burns.
Minimizing Structural Energy Loss Andrew Layman Lisa Phillips.
Andrew Layman Lisa Phillips. What is the primary source of energy loss in a house and what are some solutions to minimize this loss?
Wales Building Regulations 2013 Part L Existing non-domestic buildings September 2012.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
1 ISAT Module III: Building Energy Efficiency Topic 7: Transient Heating and Air Conditioning Loads  Thermal Admittance  Intermittent Heating 
Domestic Demand Victoria Roberts February 24 th 2005.
Lecture 15 - Timber Wall Framing Example
AT – 201 Introduction to Architecture Dan Trent August 28,
CP Energy Ltd Working for a sustainable lining earth Applied Thermography.
10 Ways to Save Energy in the Home. 1. Shut the Curtains at Dusk Make sure that they don’t hang in front of the radiators or the outside wall will benefit.
Heat loss, U-values and all that stuff. First a bit of Science First Law of Thermodynamics You can’t get more heat out of a closed system than you put.
Unit 6: Building Technology in Construction Learning Outcome Understand the techniques used in the construction of superstructures for low-rise domestic.
When drawing your plan, try and add as much detail as you can, labelling different features, such as double glazed windows and cavity walls. Draw two.
Payback time! 1. Lesson objectives  understand methods to reduce energy loss from the home.  understand how these methods work (the keyfacts).  understand.
GCSE ENERGY; THERMAL ENERGY TRANSFER 2
INTERIOR DESIGN Ms. Cromartie Spring 2015 Mod
Learning Outcome Lesson Objective
Heat transfer Steady state conditions not for dynamic systems in buildings through walls, roofs, floors, windows, doors building structures and U-values.
BRE: urbaneer findings
Getting to Zero Carbon Heather Stamp Low Carbon R&D Manager
LEVEL 4 Air Pressure Testing
HOUSES AND THE CONCEPT OF HOME FOR THE BRITISH
Prepared by Frank Cooney B.Arch MRIA
Energy Efficiency for Ashton Hayes
Interior Design Designing Functional Interiors & Floor Plans
[16469] Low Energy Building Design
RdSAP Conventions version 10.0
Pritesh h prajapati Arvind g prajapati Arvind m prajapati Arvind khata.
Building standards Mr. Da Silva.
NZEB Dwellings and Major Renovations
Presentation transcript:

Windows When assessing window area consider the whole dwelling (windows, glazed doors and roof lights), including any extensions (but not conservatories). Typical applies if the surface area of the glazing in the dwelling is essentially as would be expected of a typical property of that age, type, size and character. Even if there is slightly more or less glazing than would be expected, up to 10% more or less. More than typical applies if there is significantly more surface area of glazing than would be expected (15%-30% more), perhaps because there is a large sun room or numerous patio doors have been added. Less than typical applies if there is significantly less glazing than would be expected. This is rare as homeowners tend not to take out windows, but a property may have an unusual design with few windows. Much more than typical and Much less than typical should be used for those dwellings with very unusual amounts of glazing; such as a glass walled penthouse flat or a Huff Haus. Due to this option allowing measurements of each window to be accounted for, it can also be used if a dwelling has a mixture of glazing types e.g. single, double and triple.

Window U-values and g-values U-values and g-values for windows can be overwritten only if documentary evidence is provided, which can be either a Window Energy Rating certificate (as defined by BFRC) or manufacturer’s data. The U-value is for whole window, not centre pane. Use Table S14

Appendix S - Doors In RdSAP the definition of what is a window and what is a door is defined by the area of glazing in relation to the area of the whole opening, i.e. door and frame. To be classed as a window a glazed door and frame must contain glazing amounting to 60% or more or its surface area. An external door is a door that forms part of the heat loss perimeter of the dwelling. A door to a heated access corridor is not included in the door count.

External Doors A door is counted as insulated only if documentary evidence is provided, which must include U-value or manufacturer reference enabling the assessor to ascertain the U-value from the manufacturer. If there is more than one insulated door and they have different U-values, enter the average U-value.

Draft proofing RDSAP 9.91 requires the DEA to assess and collect the number of windows and doors that are draught proofed to allow a more accurate recommendation for draught proofing. Look for draught strip around doors and windows. With multiple glazed windows open the windows and check the seals.

Draught proofing All external doors and at least 2 windows per building part should be examined. If a window is locked or inaccessible then endeavour to check another one. If the state of the draught proofing cannot be determined then take triple, double or secondary glazed as being draught proofed, and single glazed windows and doors as not draught stripped. Include glazing in a non-separated conservatory. The percentage draught proofed is [(number of draught proofed windows & doors) divided by (total number of windows & doors)] x 100

External Doors A door is counted as insulated only if documentary evidence is provided, which must include U-value or manufacturer reference enabling the assessor to ascertain the U-value from the manufacturer. If there is more than one insulated door and they have different U-values, enter the average U-value.

Standard Assessment Procedure 8 Livewide - Innovative Learning Standard Assessment Procedure Full SAP is used in Building Regulations, and has to be calculated for every new home built, for new extensions and conversions The RDSAP (Reduced Data SAP Rating) has been developed to provide a consistent method for existing houses Introduction of RDSAP Reduced Data set than Full SAP standardised methodology for energy rating existing properties (c) Lifewide February 2007 8

Assumptions Assumes standard occupancy standard heating pattern Livewide - Innovative Learning 9 Assumptions Assumes standard occupancy standard heating pattern lighting Locality Running costs calculated using a standard (average) heating pattern of 9hours heating a day during the week and 16 hours a day at the weekend Living area heated to 21°C and the rest of the house to 18°C Excludes (factors that do not affect RdSAP conventions) cost of cooking running other appliances Rating is not affected by living habits of the occupying households (c) Lifewide February 2007 9

RdSAP changes Appendix S – Main guidance of criteria for survey techniques Appendix T – Improvement Measures guidance Conventions – this is to standardise, provide consistency and ensure DEAs are compliant. They are developed by the stakeholder group and formally released by CLG (formerly DCLG) New changes highlighted in blue for 2012

Draught proofing is a cheap and efficient method of saving both energy and money Draughts are similar to ventilation in that they supply the home with fresh air. However, draughts are uncontrolled and can let in too much cold air as well as allowing heat to escape. Draught proofing blocks up any unwanted gaps that let cold air in Types of draught proofing can include: – Self adhesive sealant strips – Brushes – Spray foams (sprayed into gaps around windows)

Livewide - Innovative Learning 1212 Habitable rooms This is a simple count of the number of habitable rooms in the dwelling Habitable rooms include living room, sitting room, dining room, bedroom, study and similar; The count of habitable rooms excludes hall, stairs and landing, kitchen, utility room, bathroom, cloakroom, en-suite and similar Where there are ‘open plan’ rooms, count as 1 room. A lounge/dining room with the door permanently removed (hinge holes filled etc) is one habitable room In addition to the above, if half or more of the habitable rooms are not heated these rooms should be recorded on the survey form (for inadequate heating purposes). For a kitchen to be a kitchen/diner it must have space for a table and 4 chairs A lounge/dining room where the door was temporarily removed (ie architrave and hinges still there) is two habitable rooms An non-separated conservatory adds to the habitable room count if it has an internal quality door between it and the dwelling. (c) Lifewide February 2007 12

Some important definitions Livewide - Innovative Learning 1313 Some important definitions Heat Loss Wall – is one which separates the heated part of the dwelling from the unheated external environment or a part of the dwelling which is unheated i.e. a wall through which heat will be lost Party Wall – is a shared wall between two properties which may be semi-detached, terraced or flats Party walls are not considered heat loss walls as losses or gains through party walls to other dwellings (or premises that are normally expected to be heated) are assumed to be zero. (c) Lifewide February 2007 13

Measuring buildings A lot of the data required from inspection relates to measurement of floor areas. RICS Code of Measuring Practice Gross Internal Area (GIA) “Gross Internal Area is the area of a building measured to the internal face of the perimeter walls at each floor level.” Party walls in shared ownership are to be measured to their centre line Excludes perimeter wall thickness and external projections

So what do we actually have to measure? Livewide - Innovative Learning 1515 So what do we actually have to measure? Floor Dimensions – Measure between the inner surfaces of the external or party walls, disregarding the presence of any internal walls Alternatively, the external walls of the building can be measured and used instead; the software then converts these figures, making an allowance for the thickness of the walls When entering measurement data, you are required to indicate which measurements are being used – internal or external. Stairs - the floor area should be measured as if there were no stairs but a floor in their place at each level. Built-in Cupboards should be included in the calculation of the floor area where these are directly accessible from the occupied area of the dwelling. (c) Lifewide February 2007 15

A SET OF 6 FLATS SEPARATED BY A ‘HEATED’ ACCESS CORRIDOR. Livewide - Innovative Learning 1616 A SET OF 6 FLATS SEPARATED BY A ‘HEATED’ ACCESS CORRIDOR. Flat A is an Enclosed End-Terrace flat that has two heat loss walls, 5+4 = 9m. The access corridor is heated and the wall between the flat and corridor is deemed to be a party wall and as such no heat loss is calculated through it. (c) Lifewide February 2007 16

A SET OF 6 FLATS SEPARATED BY A ‘HEATED’ ACCESS CORRIDOR. Livewide - Innovative Learning 1717 A SET OF 6 FLATS SEPARATED BY A ‘HEATED’ ACCESS CORRIDOR. Flat B is an Enclosed Mid-Terrace flat, and has just one heat loss wall measuring 4m. (c) Lifewide February 2007 17

Livewide - Innovative Learning 1818 Example 5 This set of 6 flats is separated by an ‘unheated’ access corridor. Flat A is an Enclosed End-Terrace flat that has three heat loss walls, 4+5+4 = 13m. Flat B is an Enclosed Mid-Terrace flat, and has two heat loss walls, 4+4 = 8m. (c) Lifewide February 2007 18

Flats and position Floor type considerations Suspended Timber and suspended Concrete – look for air bricks at the lower levels of the property Solid – there is no air brick and the floor has not steps towards the entrance of the property You must also indicate what is on the other side of the floor such as Ground floor, Above heated space, same dwelling below etc Flats and position When we deal with a flat, we have to consider the position it occupies in the block of flats. We do this by starting from the ground floor, mid-floor and top floor

Bay windows calculations

How to measure wall thickness 1. Take a measurement at door or window reveals

A difference in wall thickness is not in itself a reason to in- clude an alternative wall, unless it is a stone wall and the dif-ference in thickness is greater than 100 mm. Disregard when less than 10% of total exposed wall area of the building part (including windows and doors) unless documentary or visual evidence exists of different retrofit- ted insulation either of the alternative wall or of the re- maining wall in the building part. When entering alternative wall area into the software ex- clude the area of any windows and doors contained in the alternative wall. Consolidate walls of same type.

Walls: Dry-lining Dry-lining is the addition of plaster board to an existing wall, either with dabs of plaster, on battens, or lath and plaster. Dry- lining is any wall lining with no insulation which creates an air space behind it. Although dry lining alone is not insulation, it can reduce the U-value significantly. It may be applied to ‘straighten’ an old uneven wall. The presence of dry-lining should only be assessed when insulation is as-built or unknown and for the following wall constructions: Granite or Whinstone Sandstone Solid brick

YOU CAN ASSESS DRY-LINING BY TAPPING THE WALL: Dabs of plaster adhesive will make a different sound to the rest of the plaster board Battens will sound solid, the air gaps in between will sound hollow Lath and plaster will normally be visible in cupboards and should produce a hollow sound when tapped If you are in doubt, do not select dry-lined.

Internal Wall Lining This is a new convention for the new RDSAP 9.91 data collection ‘dry-lining’ or ‘internal wall lining (creating an air space behind)’. This includes any type of internal lining that creates an airspace behind it, e.g. plasterboard on dabs, lath and plaster. Use tap test for plaster board on dabs or on battens. If tap test is inconclusive regard as not dry- lined. Note: This applies only to stone or solid brick walls.

Heat loss floor area for houses and bungalows The area of the lowest occupied floor of the main dwelling is a ground floor. If the lowest occupied floor of any extension is not a ground floor increase the level of each storey in that building part by 1 for the purposes of the SAP calculation. For each building part examine the floor areas on each storey. If the area of any upper floor is greater than that of the floor below, the difference in these areas is an exposed or semi- exposed floor. This can occur particularly when there is an integral garage. When external dimensions are being used, however, the method of dimensional conversion can result in a small, but spurious, exposed floor area. To avoid that situation., the area of exposed floor on any level cannot be greater than the difference between the area of the current floor and the floor below measured using external dimensions.

U-value and insulation are mutually exclusive U-value and insulation are mutually exclusive. If U-value is known, the U-value should be entered and ‘Insulation thickness’ is not relevant

Livewide - Innovative Learning 2929 Stores & utility rooms should be included if they are directly accessible from the occupied area of the dwelling, whether heated or not should not be included if they are unheated and accessible only via a separate external door. (c) Lifewide February 2007 29

Basements should be included only if consisting of heated and habitable rooms. Include when accessed via a permanent fixed staircase such that one is able to walk downwards facing forwards and either:- basement is heated via fixed heat emitters, or - basement is open to the rest of the dwelling. Does not necessarily contain habitable rooms.

Garages Attics Roof spaces Livewide - Innovative Learning 3131 Garages should be included if heating is provided within the garage from the main central heating system should not be included where the garage is thermally separated from the dwelling and is not heated by the central heating system. Attics should be included if they are habitable rooms, accessed by a fixed staircase and have natural light Roof spaces should not be included unless they are habitable rooms accessed by a fixed staircase and access to natural light (c) Lifewide February 2007 31

DETAILED MEASUREMENTS OF ROOF ROOMS Detailed measurements of roof rooms are required only if evidence exists that the slope, stud wall (or common wall) or gable wall (see Figure S3) have differing levels of insulation and each of their U values is known. See Figure S3. If all elements of the roof room (slope/stud/gable) have the same insulation and the U-value is available, the U-value can be overwritten whilst leaving the RdSAP assumed areas as is. Where detailed measurements are made and the floor area of the parts of the dormer windows protruding beyond the roof line is less than 20% of the floor area of the roof room, measure the elements of the roof room as if the dormers were not there. Otherwise total the vertical elements of all dormers in that building part and enter as stud wall and the flat ceiling elements as flat ceiling. A roof room is indicated as ‘connected’ if it is adjacent to (i.e. at the same level as) another building part of the same dwelling (which can be either a roof room or a normal storey).

For detailed measurements of roof rooms there can be up to two of each of: - flat ceiling - sloping ceiling - stud wall (or common wall) - gable wall A U-value must be provided for each non-zero area. Figure S3 : Different parts of roof rooms

Partially insulated roof rooms

When roof room details are collected, the following data can be entered: – Actual area – Actual U-value

Position of Flats in Block When assessing a flat an assessor is now required to record 2 elements for flats; 1. Which floor, 0,1,2,3, etc.? Where the ground/basement level is recorded as 0, 2. What floor type is the flats lowest occupied floor in the block, as one of the following options; Basement Ground-floor Mid-floor Top-floor This data is not used in the actual calculation, but it enables the assessor to control what is written for dwelling type on the EPC.

Heating systems What provides space heating? Primary heating system Heats the largest proportion of a dwelling Not normally based on individual room heaters ( for example gas fires in most rooms) although it can be Often provides hot water Includes: Central heating systems with radiators or underfloor heating Community heating Electric storage systems Electric underfloor heating Warm air systems Room heaters

Secondary heating system Based on a room heater Secondary heating system is to be specified if the main heating system is not sufficient to heat the dwelling to levels that SAP is based on These levels are 21°C in living areas and 18°C elsewhere Gas Mains gas LPG Bottled Electricity Tariffs 7-hour off-peak (Economy 7) – typically Dual electric meters 10-hour off-peak = time for space & water heating 24-hour = On-peak – typically for single electric meters and key meters

Definitions Boiler Gas or liquid fuelled appliance designed to provide hot water for space heating May or may not provide domestic hot water as well Condensing boiler Designed to make use of the latent heat released by the condensation of water vapour; boiler allows condensate to leave heat exchanger in form of condensate

Solar Water Heating