10/16/07EFCOG Electrical Safety Task Group 1 Battery Safety and Handling EFCOG Electrical Safety Task Group Module 9.

Slides:



Advertisements
Similar presentations
Acids, Bases, and Solutions
Advertisements

1 AUTOMOTIVE BATTERIES Battery function Battery parts Chemical actions Discharge cycle Charge cycle Battery ratings Battery Maintenance Charging Jumping.
$1 Million $500,000 $250,000 $125,000 $64,000 $32,000 $16,000 $8,000 $4,000 $2,000 $1,000 $500 $300 $200 $100 50:50.
$1 Million $500,000 $250,000 $125,000 $64,000 $32,000 $16,000 $8,000 $4,000 $2,000 $1,000 $500 $300 $200 $100 Welcome.
BATTERIES Heart of the electrical system. Functions Supply energy to electrical systems when the vehicle is not running Operating cranking system Store.
Oxidation-Reduction Reactions LEO SAYS GER. Oxidation and Reduction (Redox)  Electrons are transferred  Spontaneous redox rxns can transfer energy 
The Discovery of Chemical Change Through the Chemistry of Copper
Electrochemistry The study of chemical reactions that produce electrical current or are driven to occur by applying an electrical current. Chemical potential.
Household Hazardous Waste. Flammable / Ignitable O wastes can create fires under certain conditions, are spontaneously combustible, or have a flash point.
Automotive Batteries.
General Industrial Battery Safety Changing and Charging Storage Batteries (g)  Battery charging installations shall be located in areas designated.
Automotive Batteries Chapter 29.
Chemistry of Acid Rain How it relates to elements, compounds, and mixtures…
TCAP Review Lesson 17 Vocabulary Foldable (IX)
By: John Vang & Gee Yang. What is Hydrogen is the simplest atom and is even lighter then air. A highly combustible gas and also very flammable. Made of.
Chapter 8 Oxidation and Reduction: Burn and Unburn Chemistry for Changing Times 10 th edition Hill/Kolb Daniel Fraser University of Toledo, Toledo OH ©2003.
Electrochemistry. Electrochemical Cells  Electrons are transferred between the particles being oxidized and reduced  Two types –Spontaneous = Voltaic.
Content page Introduction of Electrolysis Properties of sea water Compositions of sea water Electrode Electrolysis of sea water Chlorine gas Hydrogen.
Explain the process of electrolysis and its uses
When bleach is treated with an acid, evolution of chlorine gas ensues Preparation of Chlorine Gas from Bleach.
Electrochemical Cell An electrochemical cell uses chemistry to produce electricity.
Guided by:- Guided by:- Hitesh Patel Hitesh Patel Vidhi Mody Submitted by:- Kotadiya Reshma 26 Maniya Saguna 30 Sojitra Rachna 54 Sidpara Pooja 52 BRANCH:-
CLASSES OF BATTERIES PRIMARY CELLS SECONDARY CELLS.
The hazardous communication standard uses two primary ways to communicate the chemical hazards to the employees: the label on the chemical container and.
October 3, What is an acid? Acids are compounds that accept electrons from other chemicals known as bases. Many acids contain hydrogen. Acids taste.
Acids and Bases. Acids Properties –a substance that produce hydrogen ions (H + ) in solution –conduct electricity well –can taste sour –corrosive (“eat.
Chemical Reactions Acids and Bases. Common Acids and Bases Safe and Dangerous Acids Lactic acid By product of cell metabolism when there is too little.
Introduction to Process Technology Unit 5 Applied Chemistry.
Battery Reactions and Chemistry In any battery, an electrochemical reaction occurs like the ones described on the previous page. This reaction moves electrons.
SECTION 2 TERMINOLOGY. HAZARDOUS MATERIALS PROPERTIES.
Chemical Bonds and Reactions. Two kinds of bonds Ionic Covalent Chemical Bonds and Reactions.
Chapter 21.  Two types: ◦ Voltaic cell: electrons flow spontaneously ◦ Electrolytic cell: electrons are forced to flow.
© 2013 Cengage Learning. All Rights Reserved. May not be scanned, copied or duplicated, or posted to a publicly accessible website, in whole or in part.
Properties of Matter Physical Properties: Can be observed without changing a substance into another substance. Boiling point, density, mass, volume, etc.
Chapter 6 Bonding, Mixtures, and pH. What do atoms make up? ELEMENT: a substance made up of the same atoms – i.e. oxygen (O), gold (Au), carbon (C), COMPOUND:
Chapter 2 Review. Define matter. Anything that has mass & takes up space.
CHEMICAL BONDS & pH SCIE 203 SPRING CHEMICAL BONDS Atom - smallest part of an element that can take part in reactions. Molecule - a stable arrangement.
Salt Power Chloe Shreve and Helen Row.  It uses an electrochemical cell. In the cell there are anodes, cathodes and electrolytes that concert chemical.
Chapter 1&2 Review. Anything that has mass and takes up space is ___________. Anything that has mass and takes up space is ___________. matter matter.
Welcome to... ROUND Scoreboard X O Click Here if X Wins Click Here if O Wins.
Biochemistry. Basic Elements 99% of all living things are: Sulfur (S) Carbon (C) Hydrogen (H) Nitrogen (N) Oxygen (O) Phosphorus (P)
Chapter 18: Introduction to Electrochemistry CHE 321: Quantitative Chemical Analysis Dr. Jerome Williams, Ph.D. Saint Leo University.
18.8 Electrolysis 2 Types of electrochemistry 1.Battery or Voltaic Cell – Purpose? 2.Electrolysis - forces a current through a cell to produce a chemical.
Chemistry: Composition of Matter. Matter Anything that occupies space and mass Mass: amount of matter in an object Mass ≠ Weight Chemical changes are.
KS3 Chemistry H2 – Energy from chemical reactions 8th January 2007.
Electrolysis Jarod Coulter. An electrolytic cell uses electrical energy to produce a change Electrolysis is forcing a current through a cell to produce.
SAFTEY PRESENTATION: BATTERY SAFTEY!!
Battery Computer Assignment
Physical vs. Chemical Properties
Electrolytic Cells Section 9.2. Vocabulary Electrolysis: electrical energy used to bring about a non-spontaneous redox reaction Electrolyte: any substance.
Let’s get started... The ATOM Elements & H 2 O MixturespH Holy Macro- molecules Dip in the MIX $ 200 $ 200$200 $ 200 $ 200 $400 $ 400$400 $ 400$400.
Presented to: By: Date: Federal Aviation Administration Fuel Cell Fire Test Plan Systems Working Group Meeting Harry Webster, FAA Fire Safety Team April.
THIN FILM GAS SENSORS Chemical sensors are important to all aspects of modern life. They Provide information about chemical substances needed by instruments.
ACIDS & BASES  What is an acid?  What is a base?  What is a pH scale and how do we use one?  What is acid rain and the affects of acid rain?
Classic Chem It’s the acid test 9-12 Science Std: Chem 5a.
Acids, Bases, and pH.
CHEMISTRY CHAPTER 19 LEO SAYS GER
Choose the Best Car Batteries for Your Car in UAE
Electrochemistry and The Chemical Cells.
Oxidation-Reduction Reactions
Effective Way to Test the Battery of your Car
Chemistry of Living Things
Redox Reactions.
Knowledge Organiser – Chemical Changes
Topic 5: Portable Power Electrochemical Cells
Oxidation-Reduction Reactions
ALIGNMENT OF CHEMISTRY SYLLABUS WITH KHAN ACADEMY RESOURCES
Atomic Bonding and pH.
Chemistry of Living Things
Batteries How Batteries Work.
Presentation transcript:

10/16/07EFCOG Electrical Safety Task Group 1 Battery Safety and Handling EFCOG Electrical Safety Task Group Module 9

10/16/07EFCOG Electrical Safety Task Group 2 Lead Acid Batteries Typically Lead- Antimony. Made up of lead plates, lead oxide with 35% sulfuric acid and 65% water solution. The solution is called electrolyte, which causes a chemical reaction that produces electrons.

10/16/07EFCOG Electrical Safety Task Group 3 Cell Element

10/16/07EFCOG Electrical Safety Task Group 4 Hazards Associated With Industrial Batteries  Hydrogen Gas explosion  Sulfuric Acid  Shock  Weight of the Battery

10/16/07EFCOG Electrical Safety Task Group 5 Hydrogen Gas  A by-product of the battery’s charging process.  Lighter than air.  Flammable in nature.  Explosive mixture at 4 – 74% by volume of air.  Can not taste or see the gas vapors.

10/16/07EFCOG Electrical Safety Task Group 6 Acid Hazards  pH <2 (Typically Sulfuric Acid)  Corrosive  Burns to skin  Burns to eyes  Never open the battery caps directly over the battery without proper PPE (faceshield, safety glasses, etc).

10/16/07EFCOG Electrical Safety Task Group 7 Electrical Hazard Exposed terminals, even on disconnected batteries, present an electrical hazard. Some battery systems are capable of discharging at extremely high rates of current. Accidental shorting of terminals or cables can result in severe electrical arcing, causing burns and electric shock to nearby personnel. Shrapnel from explosion

10/16/07EFCOG Electrical Safety Task Group 8 Electrical Safety Precautions  Never touch both battery terminals with your bare hands at the same time!  Remove rings, watches and dangling jewelry when working with or near batteries. The metal in the jewelry can cause a shock or burn if they contact the battery terminals.  Only use insulated/non-conducting tools to remove cell caps. Never lay tools or other metal parts on top of a battery.

10/16/07EFCOG Electrical Safety Task Group 9 Electrical Safety Precautions  Consider protecting battery terminals and connectors with an insulating blanket prior to working above batteries  Ensure charger is turned off before connecting or disconnecting a battery to prevent arcing

10/16/07EFCOG Electrical Safety Task Group 10 Electrical Hazard Worker lost control of a jumper wire while working above battery bank Ends of jumper were not insulated and blanket was not installed over battery terminals Event resulted in severe arcing and potential for injury to worker

10/16/07EFCOG Electrical Safety Task Group 11 Fire and Explosion Precautions  Do not smoke in battery charging areas.  Prevent open flames, sparks or electric arcs in battery charging areas.  Do not strike a battery with any spark producing item.  Keep tools and other metallic objects away from uncovered batteries.  Have an ABC dry chemical fire extinguisher in charging areas or readily available.

10/16/07EFCOG Electrical Safety Task Group 12 Fire and Explosion Precautions  Neutralize static buildup just before working on battery by contacting nearest grounded surface  Ensure battery area ventilation is operating  Only charge in well ventilated area

10/16/07EFCOG Electrical Safety Task Group 13 Battery Explosions This starting battery exploded during a load test for a diesel generator Explosion can expel debris and battery acid resulting in burns and injury to nearby personnel

10/16/07EFCOG Electrical Safety Task Group 14 Handling Battery Acid Use extreme caution when handling electrolyte and keep an acid neutralizing solution—such as baking soda readily available Always wear apron and proper eye, face and hand protection. Use non-metallic containers to handle liquid If the electrolyte is splashed into an eye, immediately force the eye open and flood it with clean, cool water for at least 15 minutes. Get medical attention.

10/16/07EFCOG Electrical Safety Task Group 15 Handling Battery Acid If electrolyte is taken internally, drink large quantities of water or milk. DO NOT induce vomiting. Call a physician immediately. Neutralize with baking soda any electrolyte that spills on a vehicle work area. After neutralizing, rinse contaminated area with water. To prepare electrolyte of a desired specific gravity, always pour the concentrated acid slowly into the water; DO NOT pour water into the acid. Always stir the water while adding small amounts of acid. If noticeable heat develops, allow the solution to cool before adding acid.

10/16/07EFCOG Electrical Safety Task Group 16 Changing Batteries  Industrial batteries used to power mobile equipment can weigh upwards of 1,500 lbs.  Ensure the battery is securely locked in place prior to pulling away from the battery changing area.  Do not attempt to stop a battery if it slides out of equipment.

10/16/07EFCOG Electrical Safety Task Group 17 Changing Batteries  Work on Batteries requires Non-Sparking and Insulated tools.  Insulation must be listed for the voltage present  Taped wrenches are not listed  Batteries should never be lifted by the post.

10/16/07EFCOG Electrical Safety Task Group 18 Safe Handling of Batteries  Use appropriate equipment to load/unload batteries from mobile equipment.  Ensure you are trained and qualified in using the loading equipment.  Keep tools and other metallic objects away from batteries.  Use Baking Soda or cleaning agent specified in AHA to neutralize spilled acid.

10/16/07EFCOG Electrical Safety Task Group 19 Jumping a Discharged Vehicle Battery When jump starting a vehicle, always wear proper eye protection and never lean over battery. Inspect both batteries before connecting booster cables. Be sure vent caps are tight and level. Make certain that the vehicles are not touching and both ignition switches are turned to the OFF position. Refer to the vehicle owners' manual for other specific information.

10/16/07EFCOG Electrical Safety Task Group 20 Jumping a Battery

10/16/07EFCOG Electrical Safety Task Group 21 Battery Jumping Sequence Connect positive (+) booster cable to positive (+) terminal of discharged battery. Connect other end of positive (+) cable to positive (+) terminal of assisting battery. Connect negative (-) cable to negative (-) terminal of assisting battery. MAKE FINAL CONNECTION OF NEGATIVE (-) CABLE TO ENGINE BLOCK OF STALLED VEHICLE, AWAY FROM BATTERY. Start vehicle and remove cables in REVERSE order of connections.

10/16/07EFCOG Electrical Safety Task Group 22 PROTECTIVE CLOTHING General Requirements for Handling For general handling of batteries with terminal post taped PPE Requirements: As specified in local AHA or procedure

10/16/07EFCOG Electrical Safety Task Group 23 PROTECTIVE CLOTHING Requirements for Electrolyte Handling PPE Requirements: Safety Glasses/goggles Rubber Gloves Face Shield Chemical Apron Boots

10/16/07EFCOG Electrical Safety Task Group 24 Safety Eye Wash & Shower Requirements An eyewash facility should be capable of flushing both eyes simultaneously for fifteen minutes and a water hose or safety shower that, if portable, is capable of drenching the body. Eyewash and drenching facilities are to be located as close to the point of exposure as possible of battery handling areas (not to exceed 25 ft.) (OSHA) If Acid comes in contact with eyes, flush for 15 minutes and report to medical immediately. If acid comes in contact with skin or clothing, rinse off for several minutes and try not to spread the electrolyte. Report to medical after rinsing. Note: Eyewash and drenching facilities are not required for non-vented batteries.

10/16/07EFCOG Electrical Safety Task Group 25 Battery Safety Know the Hazards Use the required PPE No Open Flame