Fire Investigation Case Studies Canadian Fire Alarm Association (CFAA) D. GOODYEAR FIRE CONSULTING.

Slides:



Advertisements
Similar presentations
Safety in Hospitals A Computer – Based Learning Program for Students.
Advertisements

Facilities Management and Design Chapter 4 Safety and Security systems.
Security, Fire Safety and Health and Safety at Central European University.
Fire Safety & Evacuation Planning. 2 Topics Fire in the United StatesFire in the United States Where Fires OccurWhere Fires Occur Causes of Fires and.
Fire Safety Fires occur in more than 350,000 homes and kills more than 3000 people each year in the United States. Four leading causes of house fires:
Fire Safety UNIVERSITY of N ORTHERN C OLORADO How to Move Forward/Backward when viewing this slide show To move forward press enter or the down arrow.
Fire Safety. The Basics Smoke Alarms Escape Plans Practice Preparation Knowledge.
Emergency Evacuation Zayed University, Dubai Campus.
Always present at 21% in air Almost always present Electrical arcs, sparks, appliances, open flames When all three come together we have a fire.
Fire Precautionary Arrangements Presented by Mick Leadbetter Fire Safety Adviser.
Occupational Health & Safety training and consultancy Demo version e-training for emergency procedures Start your e-training.
Ted “Smitty” Smith  I have included in the following slides some key sections from each of the codes you will primarily encounter on the test. I recommend.
Leaders in Life. Safety. Technology. Interactive Firefighter’s Display.
Fire Marshal & Medical Emergency Training Please Sign In
Fire Safety in Burnside Hall
FLOOR WARDEN TRAINING Presented by State Risk Management 2011.
Fire Prevention and Safety Health Science Class. Rationale: Fires may occur at any time, as a result of overloading wiring, smoking, improper chemical.
FIRE PREVENTION AND SAFETY PRACTICES Health Science.
Prevent False Alarms Eugene A. Cable, P.E., M.S.F.P.E. Life Safety Consultants NEHES Honorary Member 412 Horse Heaven Road Averill Park, New York
1 FIRE PREVENTION AND SAFETY IN THE HOME Name. 2 COMMON SENSE !!
Home Fire Evacuation Plan
Retirement Home Regulated under the Retirement Home Act, 2010.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
Environmental Health & Safety presents FY 2011 Michael E. Davis, MS, CSP, ARM Safety Manager, Fire & Life Safety Program Environmental Health & Safety.
WELCOME DBI & SFFD Meet the Pros October 11, 2007.
Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code, The National.
Copyright  Progressive Business Publications. Fire Prevention and Emergency Safety.
EGRESS AND FIRE PROTECTION
Church Administrators & Emergency Planning
© 2012 Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code and the.
Fire Safety 7th Grade.
Home Safety and Security
© 2008 Delmar, Cengage Learning Property Security, Emergency Response, and Fire Protection Systems Chapter 13.
Improving smoke control and protecting lives Air Sealing Industrial, Commercial, Institutional and Multi-Family Buildings to Improve Smoke Control.
Fire Safety is Everyone’s Job Jennifer Mieth Public Education Manager Department of Fire Services P.O. Box 1025 Stow, MA (978) fax: (978)
Fire Safety By Alicia Civile and Alexandra Fernandez.
Fire Marshal & Medical Emergency Training Please Sign In June 14 & 15, 2011.
Chapter 5-Fire Safety Developing Effect Ways to Prevent and Deal With Fires in Your Home.
Add name of trust / organisation in box 1 and name of trainer in box 2. Delete THIS box.
Fire No institution is immune from fire. Flood damage can be dried out and restored, stolen property has a chance of being recovered; damage from fire.
Floor Wardens Safety Monitors & Guests. Overview.
8.02 Home Safety and Security. Fire Safety Smoke Detectors Sends a loud warning signal if a fire starts Easy to install Should be placed on each floor.
Southeast Financial Center
Fire Safety By Alicia Civile and Alexandra Fernandez ASSIGNMENT 4.
FIRE SAFETY Fire Warden Training. Objectives Review NAIT fire emergency response plan To be prepared confident and equipped.
KEK, 04/28/061 Safety Plan Assumptions Break out of fire in the Beam Tunnel is negligible Cables in the Service Tunnel is main fire load They are combustible.
 There are 70,000 fires each year in Canada  Preventing fires will lessen the chance of injury or death  Knowing what to do in case of fire can save.
AREA SAFETY LIAISON TRAINING  Jennifer Laine, MPH  Safety Manager – Occupational Safety and Fire Prevention  Environmental Health & Safety.
Building Monitor Information Dominican University of California March 2016.
Fire Safety. FIRE SAFETY Know location of fire alarm pull stations. Know at least two evacuation routes. Familiarize yourself with location of fire extinguishers.
Southeast Financial Center
Civil Courthouse 201 Caroline
Family Law Center 1115 Congress
Department of University Safety & Assurances
Fire Safety & Evacuation Planning.
Environmental Health & Safety
Environmental Health & Safety
What Library Staff Should Know About Fire Safety
UCOP Emergency Building Evacuation 415 – 20th Street
ARCHITECTURAL SAFETY FEATURES –Exit Separations –Continuation of Exit Stairs from lower to upper floors –Discharge from Exits FIRE PROTECTION FEATURES.
Fire Safety for MSO, Residents, Medical Students and Nursing Students
Juvenile Justice Center 1200 Congress
ICR Discoveries 290 Munro Street Thunder Bay
Fire Safety for MSO, Residents, Medical Students and Nursing Students
Fire Prevention Safety Department
Fire Prevention and Safety
Fire Safety 7th Grade.
FIRE SAFETY At Work and Home
Criminal Justice Center 1201 Franklin
Fire Evacuation Procedures
Presentation transcript:

Fire Investigation Case Studies Canadian Fire Alarm Association (CFAA) D. GOODYEAR FIRE CONSULTING

D. GOODYEAR FIRE CONSULTING THE BUILDING Rooming and boarding house Combustible construction Three stories above ground and basement Basement- Electrical room & storage Ground floor - Variety store 2nd & 3rd floors - Rooms rented Limited exit paths Rupert Hotel

D. GOODYEAR FIRE CONSULTING Rupert Hotel THE FIRE Christmas Eve Some occupants socializing Deliberate ignition Quickly compromised escape route THE FIRE SYSTEM DID NOT WORK

D. GOODYEAR FIRE CONSULTING THE RESULT 10 FATALITIES Fire department hampered by overhead wires Criminal trial Inquest Rupert Hotel

D. GOODYEAR FIRE CONSULTING FIRE INVESTIGATION REVEALED Fire alarm AC power was turned OFF Fire alarm battery fuse was removed No records of fire alarm testing or repairs No restricted access to the fire alarm panel Rupert Hotel

D. GOODYEAR FIRE CONSULTING LESSONS LEARNED The causes and location of fires are unpredictable Fire alarm systems MUST be operable at all times Fire alarm systems MUST be thoroughly tested A logbook of fire alarm system testing and repairs must be kept Restricted access to the fire alarm panel is important Rupert Hotel

D. GOODYEAR FIRE CONSULTING THE BUILDING High rise apartment building Non-combustible construction 30 stories above ground and basement parking garage Part of a large complex 2 Forest Laneway

D. GOODYEAR FIRE CONSULTING THE FIRE Originated in apartment 509 Area of origin: the living room sofa Tenant attempted extinguishment Tenant did not close the apartment door The fire progressed rapidly to the corridor 2 Forest Laneway

D. GOODYEAR FIRE CONSULTING THE RESULT 6 FATALITIES Fire damage in the corridor on the fire floor Smoke contamination of the stairs Fire department hampered by scissor stairs The FIRE SYSTEM FAILED during the fire 2 Forest Laneway

D. GOODYEAR FIRE CONSULTING FIRE INVESTIGATION REVEALED Many fire safety issues: –Smoke spread, door closers, smoke hatches in stairwells Fire safety system failures: –Emergency lighting, exit lighting, stairwell lighting Improper fire alarm testing and repairs Failure of the fire alarm system 2 Forest Laneway

D. GOODYEAR FIRE CONSULTING FIRE INVESTIGATION REVEALED Failure of the fire alarm system: Annunciation failure Signalling failure (Bells) Emergency voice communication failure Fire fighter telephone system failure ALL FIRE ALARM FAILURES –OCCUR WITHIN THE FIRST FEW MINUTES 2 Forest Laneway

D. GOODYEAR FIRE CONSULTING LESSONS LEARNED Fire alarm system testing and repairs –must be done correctly Fire alarm systems MUST be operable at all times including during a fire Fire alarm systems SURVIVABILITY is important –must perform under real fire conditions 2 Forest Laneway

D. GOODYEAR FIRE CONSULTING THE BUILDING High rise apartment building Non-combustible construction Well maintained Occupants - senior citizens Supervised voice communication in each suite Seniors Apartment

D. GOODYEAR FIRE CONSULTING THE FIRE Suite where the occupants had just left Area of origin: at the closet outside the bedroom No fatalities or injuries Suite was destroyed Fire was contained to the suite and was detected The FIRE SIGNALS DID NOT WORK on the fire floor Seniors Apartment

D. GOODYEAR FIRE CONSULTING FIRE INVESTIGATION REVEALED The fire alarm signalling in the suite was destroyed before the fire was detected The failure of fire alarm signalling wiring in the suite prevented signalling on the entire fire floor Seniors Apartment

D. GOODYEAR FIRE CONSULTING LESSONS LEARNED Fire separations can perform well Fire in a compartment may cause wiring to be destroyed before fire is detected Issues such as fire alarm system isolators or separate circuits are important Seniors Apartment

D. GOODYEAR FIRE CONSULTING THE BUILDING High rise apartment building Non-combustible construction 22 stories above ground and basement parking garage Near rectangular in shape –Elevators near centre and separate stairs at ends of building Annunciator & CACF There had been a number of false alarms 250 Davenport

D. GOODYEAR FIRE CONSULTING THE FIRE Originated in apartment on the 9th floor Area of origin: the living room sofa Occupants left without activating the fire alarm Occupants left without closing the suite door The fire progressed rapidly to the corridor 250 Davenport

D. GOODYEAR FIRE CONSULTING THE FIRE The superintendent proceeded to the annunciator Used the elevator to investigate a possible false alarm Was nearly overcome by hot gasses and smoke Four occupants entered another elevator 250 Davenport

D. GOODYEAR FIRE CONSULTING THE RESULT 4 FATALITIES Occupants died when the elevator stopped at the fire floor 250 Davenport

D. GOODYEAR FIRE CONSULTING FIRE INVESTIGATION REVEALED The fire alarm system was activated 7:11 Initial alarm on 9th floor 7:13 Fire alarm system detected smoke in the north stairs 7:18 Alarm annunciation from all floors 9 to 25 7:20 Smoke detectors operate in south stairs Failure of the elevator door closing override Superintendent may have gone to the elevator between 7:11 and 7: Davenport

D. GOODYEAR FIRE CONSULTING FIRE INVESTIGATION REVEALED NO FAILURE of the fire alarm system False alarms resulted in deviation from the Fire Safety Plan Occupants ignored the fire alarm system 250 Davenport

D. GOODYEAR FIRE CONSULTING LESSONS LEARNED Critical events can occur within the first few minutes Fire alarm system automatic functions are effective The Fire Safety Plan is important Fire safety testing –must be done correctly 250 Davenport

D. GOODYEAR FIRE CONSULTING THE BUILDING High rise apartment building Non-combustible construction 22 stories above ground and basement parking garage “Y” shape structure –Elevators near centre and separate stairs at end of corridors Upscale building with full-time security Video security in corridors and in elevators Manual elevator recall 3333 Bloor Street West

D. GOODYEAR FIRE CONSULTING THE FIRE Originated in apartment Area of origin: the bedroom Cause: ignition of the bed by flame Occupant activated the fire alarm Occupant left and propped open the suite door Fire progressed rapidly to the corridor 3333 Bloor Street West

D. GOODYEAR FIRE CONSULTING THE FIRE Female occupant on upper floor was disabled Husband was visiting niece in same building on a lower floor when the fire alarm sounded Husband used the elevator to return to wife Security used keys to place elevators on recall Elevator stopped at fire floor Husband died in elevator 3333 Bloor Street West

D. GOODYEAR FIRE CONSULTING THE RESULT ONE FATALITY Tests of elevator controls revealed the controls would activate from by-products of fire 3333 Bloor Street West

D. GOODYEAR FIRE CONSULTING FIRE INVESTIGATION REVEALED The fire alarm system was activated The security guard was not slow in recalling elevators The occupant in the elevator did not push the button for the fire floor Tests of elevator controls revealed the controls would activate from by-products of fire 3333 Bloor Street West

D. GOODYEAR FIRE CONSULTING LESSONS LEARNED Fire can progress to life endangering size within minutes Fire alarm systems are useful in the automatic operation of life safety functions Ancillary functions must be properly installed and tested 3333 Bloor Street West

D. GOODYEAR FIRE CONSULTING THE BUILDING Low rise commercial building Non-combustible construction 3 stories Rectangular in shape Many different tenant spaces Sprinklered with a fire alarm system Contained a FIRE SIGNAL RECEIVING CENTRE Video security in corridor near the station 2660 Southvale

D. GOODYEAR FIRE CONSULTING THE FIRE Occurred at approximately 11 PM Located on third floor Building was mostly unoccupied Three people on duty in the monitoring station 2660 Southvale

D. GOODYEAR FIRE CONSULTING THE RESULT THE FIRE RECEIVING CENTRE Monitors thousands of accounts Had to evacuate almost immediately Reacted quickly and had a contingency plan Alternate stations were able to handle the communications After fire - station personnel unable to access station even though not damaged 2660 Southvale

D. GOODYEAR FIRE CONSULTING FIRE INVESTIGATION REVEALED Originated in small unit (7 feet 2 inches by 9 feet) Fire progressed rapidly to the corridor Delayed detection due to sprinkler system problem Monitoring station quickly abandoned 2660 Southvale

D. GOODYEAR FIRE CONSULTING LESSONS LEARNED Fire can progress to life endangering size within minutes Delayed activation of fire alarm systems are problematic Critical functions or operations may be at risk due to other tenants Contingency plan necessary for critical functions or operations 2660 Southvale

D. GOODYEAR FIRE CONSULTING SUMMARY: LESSONS LEARNED The incredible speed of fire The destructive power of fire The unpredictable nature of occupants The vulnerability of elevators The survivability of fire alarm systems The value of a Fire Safety Plan The value of contingency plans The value of thorough testing Ethics in the Fire Safety Business