Measurement of CV variables. In vitro Total control of confounding variables –Vasomotion, temperature changes, autoregulation, mean BP Most accurate because.

Slides:



Advertisements
Similar presentations
Blood Pressure.
Advertisements

Measuring: -Temperature -Pulse -Blood Pressure -Body mass index
Pulse palpation Pulse pressure  The pressure felt as the blood in the artery surges through the point that has pressure applied.
Monitoring The Emergency Patient ABDULRAHMAN SINDI ( Emergency Medicine Resident)
MEASURING & RECORDING VITAL SIGNS Clinical Rotations.
Arterial Catheters Systemic arterial blood pressure is most accurately measured by placing a catheter directly into a peripheral artery. Peripheral arterial.
NUR 111: SKILL 5-5: ASSESSING ARTERIAL BLOOD PRESSURE ASSESSING A BLOOD PRESSURE : I FEEL THIS IS ONE OF THE MOST IMPORTANT SKILLS, AS A NURSE, THAT YOU.
Chapter 5 Part Two Blood Pressure and flow by Ibrhim AlMohimeed BMTS /3/2013.
Pulse and Blood Pressure
Vital Signs Review. What is Blood Pressure? Blood pressure measures the force of blood pulsing outwards on your arterial walls. NORMAL ADULT BP is systolic.
Presentation Package for Concepts of Fitness and Wellness 6e Section III: Concept 08 Cardiovascular Fitness All rights reserved.
Blood pressure measurement PHCL 326 (1+1) Clinical skills for pharmacists.
Copyright 2002, Delmar, A division of Thomson Learning Chapter 9 General Survey and Vital Signs.
Measuring & Recording Vital Signs
DEPARTMENT OF ENGINEERING SCIENCE INSTITUTE OF BIOMEDICAL ENGINEERING Marco F Pimentel, Graduate Student, Centre for Doctoral Training in Healthcare Innovation,
Pulse and Blood Pressure
Blood Pressure By Dr. Ola Mawlana.
Blood pressure.
Blood Pressure— The driving force Stephen Hales 1733 Blood pressure (hydrostatic pressure) is the force exerted by the blood against any unit area of vessel.
 Temperature (T)  Pulse (P)  Respiration (R)  Blood pressure (BP)  Pain (often called the fifth vital sign)  Oxygen Saturation.
Blood Pressure Assessment
Chapter 13 Blood Pressure Monitoring. Originates from the heart Value depends on 3 factors: cardiac output diameter of arteries the quantity of blood.
Blood pressure monitoring Monica Morosan. AAGBI standards of monitoring A - Induction and Maintenance of Anaesthesia 1. Pulse oximeter 2. Non invasive.
In vitro Total control of confounding variables –Vasomotion, temperature changes, autoregulation, mean BP Most accurate because vessel examined directly.
Measuring and Recording Blood Pressure
Understanding Blood Pressure. Your heart sends blood to the whole body Oxygen Nutrients Carries away waste Heart Parts: Arteries Capillaries Veins.
Arterial blood pressure is a measure of the pressure exerted by the blood as it flows through the arteries. The systolic pressure is the pressure of the.
Arterial Blood Pressure Taking a person’s Blood Pressure with a sphygmomanometer.
Measuring and Recording a Blood Pressure. Blood Pressure (BP) is one of the four vital signs you will be required to take. It is important that your recording.
Healthcare Science Vital Signs
VITAL SIGNS BLOOD PRESSURE (BP).
Copyright 2002, Delmar, A division of Thomson Learning Chapter 9 General Survey and Vital Signs.
Managing Blood Pressure: It Takes a Team
Blood Pressure PN 1 Nursing Skill Labs. Blood Pressure Force (or pressure) of blood in arterial walls in response to a ventricle contraction & ejection.
 Blood pressure means the pressure exerted by blood on the wall of the arteries.  Unit of Measurement-----mmHg  Normal BP  Systolic (100—14ommHg)
© 2009 The McGraw-Hill Companies, Inc. All rights reserved Vital Signs: Blood Pressure.
RET 1024L Introduction to Respiratory Therapy Lab Module 4.1 Bedside Assessment of the Patient —Vital Signs: Pulse, Respiratory Rate, Blood Pressure, Pulse.
VITAL SIGNS BLOOD PRESSURE PULSE TEMPERATURE RESPIRATIONS.
© 2012 Pearson Education, Inc. Pulse Pressure wave of blood Monitored at “pressure points” in arteries where pulse is easily palpated Pulse averages 70.
Electromyography (EMG)
Chapter 1 Vital Signs Copyright © The McGraw-Hill Companies, Inc.
Sphygmomanometer Gauges
Cardiac Cycle aortic pressure ventricular pressure atrial pressure
HOW TO MEASURE BP P Position pt arm with palm up at heart level, exposing upper arm – measure directly on skin NOT over clothing!! 2.Feel for brachial.
Temperature- Pulse- Respiration and Blood pressure.
Blood Pressure Review Medical Therapeutics.
Authors: Noor Mohammed Dr. M.Z. Hossain Dr. Sumon Saha
BLOOD PRESSURE MEASUREMENT OF THE PRESSURE THAT THE BLOOD EXERTS ON THE WALLS OF THE ARTERIES DURING THE VARIOUS STAGES OF HEART ACTIVITY. –AS THE HEART.
Forces acting on blood during circulation
BLOOD PRESSURE MEASUREMENT Sharon Jones Chapter 17.
Blood pressure measurement Presented by -Deepika Jain -Divya Jain
Please get your assigned computer. Do not turn on until instructed.
Key Points Definition of Blood Pressure A.The measurement of the force of blood against artery walls. 1. Force comes from the pumping of the heart 2. If.
Measuring Blood Pressure. Diagnostic Criteria for HTN Two or more separate occasions – BP > 140/90 –Average of Seated Standing for > 2 min Seated with.
FloTrac Sensor & Vigileo Monitor
PRESENTED BY : HATIM DINI.  INTRODUCTION  INDIRECT METHOD  GENERAL FACTS  PULPATORY METHOD  AUSCULATORY METHOD  ULTRASOUND METHOD  OSCILLOMETRIC.
Blood Pressure. Blood pressure is the pressure exerted by circulating blood upon the walls of blood vessels, and is one of the principal vital signs.
Noninvasive Blood Pressure Measurement © D. J. McMahon 2014 rev
 Pulse.  Respiratory rate.  Blood pressure.  Temperature.  Pulse oximetry.
Carditech, California, USA University Of West Bohemia, Czech Republic
The Arterial Blood Pressure
How to take a blood pressure
Blood Pressure.
Vital Signs: Blood Pressure
Blood Pressure August 2015 Blood Pressure.
Blood pressure measurement
Blood flow and blood pressure
How to take a blood pressure
Portable Digital Blood Pressure Monitor
Blood Pressure (BP) -practical
Presentation transcript:

Measurement of CV variables

In vitro Total control of confounding variables –Vasomotion, temperature changes, autoregulation, mean BP Most accurate because vessel examined directly Best for detailed information about mechanical properties of vessel material In vivo (invasive) Realistic clinical information Limited by technical problems –Measurement errors, transitory changes in diam. BP etc In vivo (non-invasive) Further technical problems –Especially pressure

Measurement of blood pressure Invasive –Pressure catheter and transducer Non invasive –Sphygmomanometry Auscultation (by ear or automatically by microphone) Oscillometry –Volume clamp –Tonometry

Invasive –Accurate reproduction of central pressure waveforms –Risk of thrombosis and arrhythmias Non-invasive –Quick, cheap, widely used –Lack of central pressure measurement –Requires skilled and experienced operators Advantages/ drawbacks

Sphygmomanometry Pulse detector (stethoscope or microphone) Manometer (mercury or capsule type) Manometer (mercury or capsule type) d d + 20%

Sphygmomanometry 1896 Blood pressure cuff (Riva Rocci) 1905 First report of audible detection of heart sounds used with cuff (Korotkov) 1968 Microphone used for automatic pressure measurement (Stegall)

Sphygmomanometry Capsule manometer Replacing mercury spymomanometer Mercury sphygmomanometer

Korotkov Sounds caused by vibrational collapse of the arterial wall?? Cuff pressure Systolic Diastolic –Korotkoff V is the commonly recommended measuring point except in pregnant patients because: It is associated with less inter- observer variations It is easier to detect by most observers

Errors Korotkoff sounds compared to invasive blood pressure measurement –Korotkoff IV is on average 8mm Hg above the invasively measured diastolic blood pressure –Korotkoff V is on average 2mm Hg above the invasively measured diastolic blood pressure

Oscillometry Cuff round the arm Pressurise cuff (> systolic) Allow pressure to drop slowly to zero Measure pressure in the cuff during deflation

Oscillometry: set up Pressure transducer Air pump Bleed valve Micro- processor Micro- processor Display

Principle of oscillometry Variation of cuff pressure as cuff is deflated Filtered signal Of cuff pressure

Limitations Inaccurate / unreliable in shock patients Inaccurate / unreliable in patients with arrhythmias –The algorithm of measurement assumes a regular pulse, so the reading is unreliable in patients with irregular pulse Advantages No skill required No subjective errors

Volume clamp Air Infra red emitter Detector Artery Finger Pressure Detected signal Change cuff pressure Measure cuff pressure To pump Diameter

Applanation tonometry Detects pressure of arterial pulsations through the skin

Problem: AorticRadial Aortic and peripheral pressures are different. The heart doesn’t care what the pressure is in the radial artery. It only “sees” aortic pressure. Aortic pressure is difficult (impossible?) to measure non- invasively Can we reconstruct the aortic waveform from the radial? Systolic Diastolic Mean

Yes we can. At least in principle Record radial waveform with tonometry Apply inverse transfer function “Reconstruct” aortic waveform –What is an inverse transfer function? –How do we reconstruct the waveform?

Fourier analysis H1 + H2 H H1 + H2 + H3 H4 Mean H1 H2 Measured H1+H2+H3+H4

Pa(t) = pa 0 + pa 1 Cos(  t -  a 1 ) + pa 2 Cos(  t -  a 2 ) + pa 3 Cos(  t -  a 3 ) +... Pb(t) = pr 0 + pr 1 Cos(  t -  r 1 ) + pr 2 Cos(  t -  r 2 ) + pr 3 Cos(  t -  r 3 ) +... For each harmonic (n) Transfer function phase =  a n -  r n Transfer function amplitude = pa n / pr n aortic pressureradial artery pressure

Amplification of the pulse AA - CA CA - RA AA - RA

How to derive the central pressure from peripheral measurements Compare Fourier series of “typical” aortic pressure waves with Fourier series of the radial pressure computed from tonometric measurements. Calculate the amplitude ratio and phase difference for each harmonic Apply this ratio and phase difference to each harmonic of the measured radial wave and reconstruct aortic wave that would when transmitted down the arm, producing the measured radial wave

Question How well does the typical transfer function apply to people of different ages and disease states Answer Surprisingly well considering the changes that occur in the arterial system with age and vascular disease However, most believe that more work is needed to validate the method

Pressure transducers (for invasive measurement) Fluid filled chamber Stiff diaphragm Measure its movement electronically To pressure to be measured, (via an intra arterial cannula) Diaphragm manometer Advantages Cheap, disposable easy to use Accurate mean pressure Disadvantages Clotting in cannula, air bubbles Therefore errors in pulse pressure

Pressure transducers (for invasive measurement - 2) Cannula tip manometer Semi conducting strain gauge Diameter may be as small as 0.67 mm Advantages High accuracy Especially in very small vessels Disadvantages No calibration possible when in position Expensive Fragile

Pressure: comparison of methods