16469- Low Energy Building Design Presentation 3- Demand/Supply Matching Marc Smeed Edmund Tsang Graham Dow.

Slides:



Advertisements
Similar presentations
Sustainable School Design Creating Healthy, High Performance School Facilities Presented by Stephen M. Koontz, Energy Services Leader, Tampa Bay Trane.
Advertisements

Formulas.
Institute of Energy and Sustainable Development HVAC S YSTEMS E NERGY D EMAND VS. B UILDING E NERGY D EMAND I VAN K OROLIJA I NSTITUTE OF E NERGY AND S.
Technical Committees – the Brains of ASHRAE Section 1.0 — Fundamentals and General.
Building Energy Rating
Lesson 3: Buying Electricity.  MUST understand how electric current transfers energy  SHOULD calculate the cost of energy used  COULD use appropriate.
Heating, Ventilating, and Air-Conditioning
Heat Recovery for Commercial Buildings
Innovative Air Distribution for Healthcare Facilities.
Chilled Beam Presentation
Timber Research Centre Michael Anderson– Mohamed Farid Pablo Prallong – Lewis Macleod Ross Turbet & Group A 26/04/20054 th Presentation.
Sustainable Hotel Design Presentation 2 Passive Design Group 5.
Sustainable Hotel Design Group 5 Presentation 4 Demand/Supply Matching.
Treatment of Mechanical Extract Ventilation and Balanced Whole House Mechanical Ventilation in DEAP Date October-2007.
1 ISAT Module III: Building Energy Efficiency Topic 6:Stead-State Building Loads z Fabric Loss z Ventilation Loss z Environmental Temperature z Steady-State.
BEM class 3 Climate & Human Comfort. Class (lecture) objectives Appreciation of the indoor and outdoor environments and how they relate to our energy.
MCS Accreditation 1 What is MCS? The MCS (Microgeneration Certification Scheme) certificates microgeneration technologies used to.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – December 2012eere.energy.gov Intermediate Math WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
RETScreen® Energy Efficiency Projects
Integrating a Saving Energy controller in Existing Air Condition units Case Study.
Energy use in buildings Dr. Atila Novoselac Associate Professor Department of Civil, Architectural and Environmental Engineering, ECJ
Passive Technologies and Other Demand-Side Measures.
 On average, home heating uses more energy than any other system in a home  About 45% of total energy use  More than half of homes use natural gas.
Ch Electricity IV. Measuring Electricity (p )  Electrical Power  Electrical Energy.
Earth’s Changing Environment Lecture 22 Energy Conservation in Heating and Cooling.
Low Energy Building Design Presentation 2- Supply Options Edmund Tsang Graham Dow Marc Smeed.
Heat Pumps triple dividend: low carbon, energy efficient & renewable Heat Pumps Low Carbon Solutions for Re-Energising the EU Thomas Nowak The European.
Implementing Demand Controlled Ventilation to Meet ASHRAE Standard By Klas C. Haglid, P.E., R.A., CEM 1.
Vermont Electric Energy Efficiency Potential Study – Draft Findings April 10, 2006.
PASSIVE HOUSING By Serena Mehta Passive housing or Passivhaus  “A Passivhaus is a building, for which thermal comfort can be achieved solely by.
Energy use in buildings Dr. Atila Novoselac Associate Professor Department of Civil, Architectural and Environmental Engineering, ECJ
IEA HPP Annex 28 Calculation of compact units Workshop IEA HPP Annex 28 8 th International Heat Pump Conference, Las Vegas, 30 May 2005 Thomas Afjei, Institute.
Low Energy Building Design Presentation 1- Regulations Marc Smeed Edmund Tsang Graham Dow.
COMP 4923 A2 Data Center Cooling Danny Silver JSOCS, Acadia University.
“Do Green” Two Options: Prescriptive Custom Prescriptive- -Must be running a MODULATING ROTARY SCREW AIR COMPRESSOR -Must be 75 Horsepower or Less Custom-
Energy Conservation Physics /24/03. Reducing energy consumption may help alleviate environmental problems: Conserve fossil fuel resources Reduce.
 On average, home heating uses more energy than any other system in a home  About 45% of total energy use  More than half of homes use natural gas.
Paying for Electricity How much does it cost to watch T.V. for 2 hours?
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
Lecture Objectives: Finish with example modeling problems –Phase change thermal storage materials –Energy and airflow Interpret energy simulation results.
Lindab | we simplify construction Smart energy saving solutions Design a sustainable future at no extra cost! eHybrid – Simplifies construction.
Calculate the missing quantities for the circuit below.
Site Location: Site Location: Gap Site at Bath Street and Pitt Street Plot: Plot: 50m x 50m Building Area: Building Area: 4000m 2 maximum Building Height:
September 26, 2015 Diego Villarreal SHP – Columbia University Introduction to Energy.
Energy By: Adrian, Andra & Marco 10U. Types of Energy There are a lot of types of energy, four of these energy are:  Kinetic Energy  Potential Energy.
A Closer Look at Energy Demands: Quantification and Characterisation.
PATTERNS OF USE IN THE UK THE EFFECTS OF GOVERNMENT POLICY.
The Sunshine Elementary School Redesign Proposal Pennsylvania State University AE Senior Thesis Nicholas Scheib Mechanical Option- IP.
Event jointly staged by Dan Bourke EnviroVent. The Importance of Efficient Ventilation Dan Bourke Regional Sales Manager South.
COMP 4923 A2 Data Center Cooling Danny Silver JSOCS, Acadia University.
U.S. Wind power since 1995 From EIA website Annual Energy Report: % annual growth DATA FIT.
Katayoun (Katie) Mokhtarzadeh TECHNICAL INTERN. About Me  B.S. Civil Engineering  M.S. Construction Engineering and Project Management – Ongoing  Interest.
Electrical Power & Efficiency.  I will be able to calculate cost to operate and percent efficiency of various devices.
Design What is the first step in designing a high-performance building? Would it be: Identify synergies Select the correct HVAC system Design around human.
Public Name: François Bruggemans Dept: New Business - Heating Carbon footprint of heating systems Lowering GHG emissions by the use of heat pumps.
Day 3 Part 3 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
1 Biogen | Confidential and Proprietary 15MAR16 Building 8 Retro-Commissioning & Optimization.
Power in Electrical Systems Power in Electrical Systems.
LoLo 2016: How many ways can you change a light bulb? Exploring methods in energy research Regional differences in thermal comfort in a stratified heated.
Heat transfer Steady state conditions not for dynamic systems in buildings through walls, roofs, floors, windows, doors building structures and U-values.
ENV-5022B/ENVK5023B Low Carbon Energy
Specifics of multi-apartment building deep complex retrofitting
Under floor Heating Graduation Project submitted By: Adli Mosleh
Environmental Thermal Engineering
Thermal Energy Storage
Date of download: 3/6/2018 Copyright © ASME. All rights reserved.
ENV-5022B/ENVK5023B Low Carbon Energy
IV. Measuring Electricity
Y11 INTERVENTION : Energy, efficiency and kWh
Cost of Electricity & Energy Usage Energy Use Recall: Measured in Watts (W) Electrical power is the rate at which electrical energy is produced.
Presentation transcript:

Low Energy Building Design Presentation 3- Demand/Supply Matching Marc Smeed Edmund Tsang Graham Dow

DEMAND REDUCTION START CIBSE ‘TYPICAL PRACTICE PRIMARY SCHOOL’ FOSSIL FUELS 164 kWh/m2 p.a ELECTRICITY 32 kWh/m2 p.a

AIR TIGHT CONSTRUCTION Assumptions Heating Period External Temp= 8.6 ° C 1 Design Internal Temp= 21°C MetricInfiltration Rate (m 3 /m 2 ACH 2005 CIBSE Part L Regs Tight Building Very Tight Building Calculated Heat Loss, per m 2 per hour = 4.04W/m 2 h Calculated Heat Loss, per m 2 per hour = 1.61W/m 2 h Saving = ( )/4.04 * 100% = 60% Energy Saving = 27.2 kWh/m 2 p.a. 1. ESP-r data output: (Average external temp for heating season)

DEMAND REDUCTION FOSSIL FUELS 164 kWh/m2 p.a AIRTIGHTNESS SAVING 27.2 kWh/m2 p.a SUB-TOTAL136.8 kWh/m2 p.a CIBSE ‘TYPICAL PRACTICE PRIMARY SCHOOL’

HEAT RECOVERY Heat Recovered = 17.7 kWh/m 2 p.a. Assumptions External Temp= 8.6 ° C 1 Design Internal Temp= 21°C Exchanger ε s = 65% 2 Occupied days per year= Occupied hours per day= 8 Ceiling Height= 3m Total Building Ventilation Rate = 1.5 ACH q s = ε s *m min *C p *(∆T) = 65%*( *1.284)*1.014*11 = kW/m 2 Heat flow rate through sensible heat exchanger 4 Occupied hours in the year = ESP-r data output: (Average external temp for occupied hours) 2. CIBSE Guide F: Table 4.6,p ASHRAE Handbook 2004: Chapter 44

DEMAND REDUCTION FOSSIL FUELS 164 kWh/m2 p.a AIRTIGHTNESS SAVING 27.2 kWh/m2 p.a HEAT RECOVERY 17.7 kWh/m2 p.a SUB-TOTAL119.1 kWh/m2 p.a CIBSE ‘TYPICAL PRACTICE PRIMARY SCHOOL’

DEMAND REDUCTION FOSSIL FUELS 164 kWh/m2 p.a AIRTIGHTNESS SAVING 27.2 kWh/m2 p.a HEAT RECOVERY 17.7 kWh/m2 p.a BEMS 2 nd Sem. kWh/m2 p.a SUB-TOTAL<119.1 kWh/m2 p.a CIBSE ‘TYPICAL PRACTICE PRIMARY SCHOOL’

79% FOSSIL FUELS LIGHTING CONTROL Assumptions 1. 21% ELECTRICITY

LIGHTING CONTROL Assumptions 1. LIGHTING = 10/21 % OF ELECTRICAL LOAD = 47% = 15.2kWh/m 2 p.a.

LIGHTING CONTROL Energy Saving= 5.33 kWh/m 2 p.a Occupancy sensors can reduce lighting load by 30-40% 1 This can rise to 75% if integrate with PSALI 1 Therefore we can assume that we could obtain at least 35% reduction. 35% X 15.2kWh/m 2 = 5.33kWh/m 2

DEMAND REDUCTION ELECTIRICITY 32 kWh/m2 p.a PSALI / PIR 5.3 kWh/m2 p.a EFFICIENT LIGHTING 2 nd Sem. kWh/m2 p.a BEMS 2 nd Sem. kWh/m2 p.a LIGHT SHELVING 2 nd Sem. kWh/m2 p.a SUB-TOTAL<26.7 kWh/m2 p.a CIBSE ‘TYPICAL PRACTICE PRIMARY SCHOOL’

ENERGY STORAGE

FLYWHEEL A rotor is accelerated, maintaining the energy in the system as inertial energy Maximum Power rating of 2000KW for a multi-cabinet type Maximum Power rating of 500KW for a single-cabinet type Stored energy discharges at a maximum time of 2 minutes

FLYWHEEL- FEASIBILTY ADVANTAGES –Flexible –Commercially available –High power outputs DISADVANTAGES –Safety concerns –Short discharge times –Expensive

HYDROGEN STORAGE The 3 key elements are Electrolysis Mechanism Hydrogen Storage Fuel Cell Hydrogen stored via Pressurised storage Ammonia Metal hydrides

FEASIBILITY High storage capacity- around 165 KWh /m 3 Only pressurised hydrogen storage is currently available for building use Other storage only commercially available for vehicles Expensive

THERMAL ENERGY STORAGE TWO TYPES Sensible –A Tank underground, used for heat storage (25kWh/m^3) Latent –Higher energy density (around 100kWh/m^3) –Phase change materials (PCM) used where it solidifies during night then melts during the day

Demand Shifting

Purpose of Demand Shifting Demand shifting makes use of storage so that peaks and troughs of demand are levelled off Requires intelligent forward thinking Can be remotely managed system and use predictions to help shift loads

What's to be gained Throttling a CHP system is not required Constant power generation can be attained, decrease maintenance problems Can help incorporate renewable systems

DEMAND SHIFTING FOR RENEWABLES Demand shifting can be used to create demand when it suits a renewable supply. For Example- Solar works when there are higher levels of solar intensity- i.e. in the summer/midday.

Energy Electrical Appliances (Fuel Cell/CHP) Lighting (Daylight Use) (Fuel Cell/CHP) Heating Space (None) Water (Solar Thermal) Energy Electrical Appliances (Fuel Cell/CHP) Lighting (Daylight Use) (Fuel Cell/CHP) Heating Space (Thermal storage/Solar Thermal Fuel cell/CHP) Water (Thermal storage/Solar Thermal Fuel cell/CHP) Energy Electrical Appliances (Fuel Cell/CHP) Lighting (Daylight Use) (Fuel Cell/CHP) Heating Space (Thermal storage/Solar Thermal Fuel cell/CHP) Water (Thermal storage/Solar Thermal Fuel cell/CHP)

SHOULD WE DECOUPLE ? FORAgainst Seen as a flagship project towards decentralised supply Why decouple when we could have the grid as a backup Encourage the use of renewable systems It’s a city centre location any excess electricity could be sold Know where our energy comes from Grid Supply could be used to meet demand peaks Attract more grant money and better staff Auxiliary backup system could over complicate design

VISION What is going to be different about our School ? –A ‘HYDROGEN’ school –A DECOUPLED school A NEW approach to school design

Any Questions ?